• Title/Summary/Keyword: 적외선검사

Search Result 129, Processing Time 0.025 seconds

Evaluation of Moisture and Feed Values for Winter Annual Forage Crops Using Near Infrared Reflectance Spectroscopy (근적외선분광법을 이용한 동계사료작물 풀 사료의 수분함량 및 사료가치 평가)

  • Kim, Ji Hea;Lee, Ki Won;Oh, Mirae;Choi, Ki Choon;Yang, Seung Hak;Kim, Won Ho;Park, Hyung Soo
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.39 no.2
    • /
    • pp.114-120
    • /
    • 2019
  • This study was carried out to explore the accuracy of near infrared spectroscopy(NIRS) for the prediction of moisture content and chemical parameters on winter annual forage crops. A population of 2454 winter annual forages representing a wide range in chemical parameters was used in this study. Samples of forage were scanned at 1nm intervals over the wavelength range 680-2500nm and the optical data was recorded as log 1/Reflectance(log 1/R), which scanned in intact fresh condition. The spectral data were regressed against a range of chemical parameters using partial least squares(PLS) multivariate analysis in conjunction with spectral math treatments to reduced the effect of extraneous noise. The optimum calibrations were selected based on the highest coefficients of determination in cross validation($R^2$) and the lowest standard error of cross-validation(SECV). The results of this study showed that NIRS calibration model to predict the moisture contents and chemical parameters had very high degree of accuracy except for barely. The $R^2$ and SECV for integrated winter annual forages calibration were 0.99(SECV 1.59%) for moisture, 0.89(SECV 1.15%) for acid detergent fiber, 0.86(SECV 1.43%) for neutral detergent fiber, 0.93(SECV 0.61%) for crude protein, 0.90(SECV 0.45%) for crude ash, and 0.82(SECV 3.76%) for relative feed value on a dry matter(%), respectively. Results of this experiment showed the possibility of NIRS method to predict the moisture and chemical composition of winter annual forage for routine analysis method to evaluate the feed value.

Quantitative Analysis of Acid Value, Iodine Value and Fatty Acids Content in Sesame Oils by NIRS (근적외선분광광도법을 이용한 참기름의 산가, 요오드가, 지방산정량법에 관한 연구)

  • Kim, Jae-Kwan;Lee, Myung-Jin;Kim, Myung-Gill;Kim, Kyung-A;Park, Eun-Mi;Kim, Young-Sug;Ko, Hoan-Uck;Son, Jin-Seok
    • Journal of Food Hygiene and Safety
    • /
    • v.21 no.4
    • /
    • pp.204-212
    • /
    • 2006
  • This study was conducted to investigate the possibility of rapid and non-des tructive evalution of AV (Acid Value), IV (Iodine Value) and fatty acids in sesame oils. The samples were scanned over the range $400\sim2500nm$ using transmittance spectrum of NIRS(Near-infrared spectroscopy). A calibration equation calculated by MPLS regression technique was developed and correlation coefficient of determination for AV, IV, palmitic acid, stearic acid, linoleic acid and linolenic acid content were 0.9907, 0.9677, 0.9527, 0.9210, 0.9829, 0.9736 and 0.9709 respectively. The validation model for measuring the AV content had R of 0.989, SEP of 0.058 and IV content had R of 0.944, SEP of 0.562 and palmitic acid content had R of 0.924, SEP of 0.194 and stearic acid content had R of 0.717, SEP of 0.168 and oleic acid content had R of 0.989, SEP of 0.221 and linoleic acid content had R of 0.967, SEP of 0.297 and linolenic acid content had R of 0.853, SEP of 0.480 by MPLS. The obtained results indicate that the NIRS procedure can potentially be used as a non-destructive analysis method for the purpose of rapid and simple measurement of AV, IV and fatty acids in sesame oils.

Effects of Beraprost Sodium Evaluated by Digital Infrared Thermal Imaging in Diabetic Patients with Peripheral Arterial Disease (당뇨병성 말초혈관병증 환자에게 Beraprost Sodium이 미치는 영향에 대한 적외선 체열검사를 통한 연구)

  • Park, Hyun Woo;Soh, Jae Wan;Park, Seong Hyeon;Jeong, Jae Jung
    • Journal of Korean Foot and Ankle Society
    • /
    • v.22 no.3
    • /
    • pp.105-110
    • /
    • 2018
  • Purpose: This study examined the effects of beraprost sodium on digital infrared thermal images in patients with peripheral arterial disease caused by type 2 diabetes mellitus. Materials and Methods: Twenty-five diabetic patients with peripheral arterial disease were treated with beraprost sodium in a prospective, multicenter, cohort study from February 2013 to December 2014. Beraprost sodium ($40{\mu}g$) was administered orally 3 times daily ($120{\mu}g/day$) for 6 months. The visual analogue scale (VAS) and digital infrared thermal imaging (DITI) were performed to compare the blood flow improvement between before and after dosing. Results: Among the 25 patients included in the evaluation, 22 patients completed the study. A significant increase in body temperature was observed in the front and left side, particularly in the plantar side in DITI compared to that before and after administration. An increase in body temperature was observed at the frontal part from $28.1^{\circ}C{\pm}2.3^{\circ}C$ to $29.1^{\circ}C{\pm}2.1^{\circ}C$ (p=0.021), at the left side from $27.8^{\circ}C{\pm}2.4^{\circ}C$ to $28.6^{\circ}C{\pm}1.9^{\circ}C$ (p=0.028), at the plantar part at $24.0^{\circ}C{\pm}1.5^{\circ}C$, and at the plantar part at $27.1^{\circ}C{\pm}2.4^{\circ}C$ (p<0.01). The VAS decreased significantly from $5.4{\pm}1.3$ to $2.7{\pm}2.0$ after 6 months of treatment (p<0.01). Conclusion: Beraprost sodium is a safe and easy-to use oral medication for diabetes peripheral arterial disease. It can be expected to increase the blood flow and decrease the lower extremity pain statistically after being taken for 6 months.

Interpretation of Making Techniques through Surface Characteristic Analysis and Non-destructive Diagnosis for the Gilt-bronze Seated Buddha in Dangjin Sinamsa Temple, Korea (당진 신암사 금동여래좌상의 표면특성 분석과 비파괴 정밀진단을 통한 제작기술 해석)

  • CHOI Ilkyu ;YANG Hyeri ;HAN Duru;LEE Chan Hee
    • Korean Journal of Heritage: History & Science
    • /
    • v.56 no.1
    • /
    • pp.100-116
    • /
    • 2023
  • The Sinamsa Temple was built in the late Goryeo Dynasty and a gilt-bronze seated Buddha is enshrined in Geungnakjeon hall in the precinct. Various damages occurred in the gilt layer of the Buddha, such as peeling of the gilt layer and deteriorating gloss. In the study, the conservation conditions of the inside and outside on the statue were accurately investigated, and the making technique was interpreted through the material characteristics and non-destructive diagnosis of the statue. As a result, it is estimated that gold-gilding layer is pure gold, coloration pigment of black is carbon, green is malachite, atacamite and verdigris, red is red lead and cinnabar, respectively. In the deterioration evaluation, peeling, cracking, break out and exfoliation of the gilt layer are confirmed as damages, but the conservation condition is relatively wholesome. However, the gloss of the gilt layer is calculated to be wider in the poorer part than the maintenance part. The ultrasonic velocity of the statue was calculated to be 1,230 to 3,987 (mean 2,608) m/s and showed a relatively wide range. In infrared thermography, peeling was not confirmed, and no special bonding marks were found. In endoscope, some biological damage and corrosion were observed on the surface of the internal metal, and sealed artifacts were identified. Manufacturing technique based on the study, it is considered that the gilt-bronze seated Buddha was cast at once, and the mold was inverted to inject molten metal.

Application Feasibility Study of Non-local Means Algorithm in a Miniaturized Vein Near-infrared Imaging System (정맥 관찰용 소형 근적외선 영상 시스템에서의 비지역적평균 알고리즘 적용 가능성 연구)

  • Hyun-Woo Jeong;Youngjin Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.679-684
    • /
    • 2023
  • Venous puncture is widely used to obtain blood samples for pathological examination. Because the invasive venipuncture method using a needle is repeatedly performed, the pain suffered by the patient increases, so our research team pre-developed a miniaturized near-infrared (NIR) imaging system in advance. To improve the image quality of the acquired NIR images, this study aims to model the non-local means (NLM) algorithm, which is well known to be efficient in noise reduction, and analyze its applicability in the system. The developed NIR imaging system is based on the principle that infrared rays pass through dichroic and long-pass filters and are detected by a CMOS sensor module. The proposed NLM algorithm is modeled based on the principle of replacing the pixel from which noise is to be removed with a value that reflects the distances between surrounding pixels. After acquiring an NIR image with a central wavelength of 850 nm, the NLM algorithm was applied to segment the final vein area through histogram equalization. As a result, the coefficient of variation of the NIR image of the vein using the NLM algorithm was 0.247 on average, which was an excellent result compared to conventional filtering methods. In addition, the dice similarity coefficient value of the NLM algorithm was improved by 62.91 and 9.40%, respectively, compared to the median filter and total variation methods. In conclusion, we demonstrated that the NLM algorithm can acquire accurate segmentation of veins acquired with a NIR imaging system.

Evaluation of Difference between Skin Motion and Tumor Motion for Respiration Gated Radiotherapy (호흡조절방사선치료를 위한 피부움직임과 종양움직임 차이 평가)

  • Kwon, Kyung-Tae;Lim, Sang-Wook;Park, Sung-Ho;Kwon, Soo-Il;Shin, Sung-Soo;Lee, Sang-Wook;Ahn, Seung-Do;Kim, Jong-Hoon;Choi, Eun-Kyung
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.14-20
    • /
    • 2008
  • Accounting for tumor motion in treatment planning and delivery is one of the most recent and significant challenges facing radiotherapy. The purpose of this study was to investigate the correlation and clarified the relationship between the motion of an external marker using the Real-Time Position Management (RPM) System and an internal organ motion signal obtained fluoroscope. We enrolled 10 patients with locally advanced lung cancer and liver cancer, retrospectively. The external marker was a plastic box, which is part of the RPM used to track the patient's respiration. We investigated the quantitatively correlation between the motions of an external marker with RPM and internal motion with fluoroscope. The internal fiducial motion is predominant in the caraniocaudal direction, with a range of $1.3{\sim}3.5cm$ with fluoroscopic unit. The external fiducial motion is predominant in the caraniocaudal direction, with a range of $0.43{\sim}2.19cm$ with RPM gating. The two measurements ratio is from 1.31 to 5.56. When the regularization guided standard deviation is from 0.08 to 0.87, mean 0.204 cm, except only for patients #3 separated by a mean 0.13 cm, maximum of 0.23 cm. This result is a good correlation between internal tumor motion imaged by fluoroscopic unit and external marker motion with RPM during expiration within 0.23 cm. We have demonstrated that gating may be best performed but special attention should be paid to gating for patients whose fiducials do not move in synchrony, because targeting on the correct phase difference alone would not guarantee that the entire tumor volume is within the treatment field.

  • PDF

A Study on Fractionation and Characterization of Water-Soluble Natural Fe-Chelates From Garbage Compost and Activated Sewage Sludge (활성오니(活性汚泥) 및 진개퇴비중(塵芥堆肥中) 수용성(水溶性) 철(鐵) 킬레이트의 분리(分離)와 특성(特性)에 관(關)한 연구(硏究))

  • Park, Nae-Joung;Lindsay, W.L.
    • Applied Biological Chemistry
    • /
    • v.18 no.4
    • /
    • pp.194-202
    • /
    • 1975
  • This study was conducted to study the properties of the water-soluble natural chelating agents from garbage compost and activated sewage sludge responsible for Fe chelation, which is closely associated with the effectiveness in correcting iron chlorosis in plant. The water-soluble fraction of these materials was fractionated by menas of Sephadex gel filtration and the fractions of Fe chehates were traced by radioactive $^{59}Fe$. The fractions were examined by ultraviolet and infrared. spectroscopy and stability constants for Fe. The water-soluble fraction from garbage compost was separated by Sephadex G-25 into approximately four fractions. Most of the added $^{59}Fe$ was associated with fraction I, which appeared at the void volume. Further fractionation by Sephadex G-50 indicated that the molecular weight of water-soluble chelating agents is in the approximate range of 5000 to 10,000. The water-soluble fraction from activated sewage sludge gave six fractions by Sephadex G-25. Most of the added $^{59}Fe$ was found in the fraction I,II, and III, The molecular weights of most chelating agents associated with $^{59}Fe$ appeared to be less than 5,000 and those of fraction I that appeared at the void volume was in the range of 5,000 to 1,000. Discrepancy between radio activity count and UV absorption indicated the heterogeneity of the fractions obtained by Sephadex gel filtration. Ultraviolet absorption spectra of all fractions separated by Sephadex G-25 and containing chelating agents showed no differences. Fraction IV and V of sewage extract showed absorption maxima and shifting similar to nucleic acid components suggesting the presence of decomposition products of nucleic acid. Similarity fraction VI contained phenolic type amino acid groups. Fraction I of compost extract contained most of the added $^{59}Fe$ and showed weak but extra definite absorption in the 1230, and $1270cm^{-1}$ region, suggesting that extra oxygen groups in polyphenolic structure were probably involved in Fe chelation. In sewage extract, fraction I,II, and III in which most of the $^{59}Fe$ was found, showed strong definite polypeptide absorption in the region of $1540cm^{-1}$ due to NH deformation and C-N stretching of amide groups in the peptidebond. These extra functional groups in fraction I, II, and III appeared to be associated with Fe chelation. The other fractions, not associated with $^{59}Fe$, still have carboxyl and hydroxyl groups, suggesting that these functional groups in these water extracts may not independently form the Fe chelates. Precipitation of ferric hydroxide precluded measuring the stability constants for Fe-chelates. However, the formation constants for Zn chelates as log K values for compost extract and sewage extract at pH 4.0 from which the strength of chelation with Fe could be presumed, were 8.23, and 9.75, respectively, indicating strong complexation with metals. The chelating capacity of compost extract containing 6.5 g organic matter per liter was 0.82 mM, and that of sewage extract containing 5.3 g per liter was 0. 64 mM.

  • PDF

Infrared Thermography in the Assessment of Temporomandibular Joint Dysorder (측두하악장애에서의 적외선 체열 촬영 검사의 유용성)

  • Nahm, Sahngun Francis;Koo, Mi Suk;Kim, Yang Hyun;Suh, Jeong Hun;Shin, Hwa Yong;Choi, Yong Min;Kim, Yong Chul;Lee, Sang Chul;Lee, Pyung Bok
    • The Korean Journal of Pain
    • /
    • v.20 no.2
    • /
    • pp.163-168
    • /
    • 2007
  • Background: Temporomandibular joint disorder (TMD) is a group of musculoskeletal conditions characterized by pain in the pre-auricular area, limitation of jaw movement and palpable muscle tenderness. Thermography is a nonionizing, noninvasive diagnostic alternative for the evaluation of TMD. This study was conducted to evaluate the usefulness of thermography in the assessment of TMD. Methods: Thermography was conducted on the 61 patients who had been diagnosed with TMD, and on the 34 normal symptom-free volunteers. The temperature differences between opposite sides of the temporomandibular joint (${\Delta}T_{TMJ}$) and the masseter muscle (${\Delta}T_{MST}$) were calculated. The sensitivity and specificity of thermography was calculated at the cut off values of 0.2, 0.3, and $0.4^{\circ}C$. Results: In the patient group, the ${\Delta}T_{TMJ}$ was $0.42{\pm}0.38^{\circ}C$ and the ${\Delta}T_{MST}$ was $0.38{\pm}0.33^{\circ}C$, whereas in the control group the ${\Delta}T_{TMJ}$ was $0.10{\pm}0.07^{\circ}C$ and the ${\Delta}T_{MST}\;0.15{\pm}0.10^{\circ}C$. In addition, the patient group demonstrated a significantly lower level of thermal symmetry than the control group (P < 0.001) in both the temporomandibular joints and the masseter muscles. The sensitivity of thermography at the cut off values of 0.2, 0.3 and $0.4^{\circ}C$ was 67.2, 49.2, and 42.6% in the temporomandibular joint (TMJ) and 60.7, 49.2 and 37.7% in the masseter muscle, respectively. The specificity of thermography at the cut off values of 0.2, 0.3 and $0.4^{\circ}C$ was 88.2, 100, and 100% in the TMJ and 61.8, 91.2 and 100% in the masseter muscles, respectively. The accuracy of thermography at the cut off values of 0.2, 0.3 and $0.4^{\circ}C$ was 74.7, 67.4, and 63.2% in TMJ and 61.1, 64.2 and 60.0% in the masseter muscles, respectively. Conclusions: Temperature differences exist between the opposite sides of the TMD and masseter muscles in patients with TMD. Although the sensitivity of thermography in the diagnosis of TMD is low, it has high specificity in the evaluation of TMD, and is therefore applicable to patients with TMD.

Mathematical Transformation Influencing Accuracy of Near Infrared Spectroscopy (NIRS) Calibrations for the Prediction of Chemical Composition and Fermentation Parameters in Corn Silage (수 처리 방법이 근적외선분광법을 이용한 옥수수 사일리지의 화학적 조성분 및 발효품질의 예측 정확성에 미치는 영향)

  • Park, Hyung-Soo;Kim, Ji-Hye;Choi, Ki-Choon;Kim, Hyeon-Seop
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.36 no.1
    • /
    • pp.50-57
    • /
    • 2016
  • This study was conducted to determine the effect of mathematical transformation on near infrared spectroscopy (NIRS) calibrations for the prediction of chemical composition and fermentation parameters in corn silage. Corn silage samples (n=407) were collected from cattle farms and feed companies in Korea between 2014 and 2015. Samples of silage were scanned at 1 nm intervals over the wavelength range of 680~2,500 nm. The optical data were recorded as log 1/Reflectance (log 1/R) and scanned in intact fresh condition. The spectral data were regressed against a range of chemical parameters using partial least squares (PLS) multivariate analysis in conjunction with several spectral math treatments to reduce the effect of extraneous noise. The optimum calibrations were selected based on the highest coefficients of determination in cross validation ($R^2{_{cv}}$) and the lowest standard error of cross validation (SECV). Results of this study revealed that the NIRS method could be used to predict chemical constituents accurately (correlation coefficient of cross validation, $R^2{_{cv}}$, ranging from 0.77 to 0.91). The best mathematical treatment for moisture and crude protein (CP) was first-order derivatives (1, 16, 16, and 1, 4, 4), whereas the best mathematical treatment for neutral detergent fiber (NDF) and acid detergent fiber (ADF) was 2, 16, 16. The calibration models for fermentation parameters had lower predictive accuracy than chemical constituents. However, pH and lactic acids were predicted with considerable accuracy ($R^2{_{cv}}$ 0.74 to 0.77). The best mathematical treatment for them was 1, 8, 8 and 2, 16, 16, respectively. Results of this experiment demonstrate that it is possible to use NIRS method to predict the chemical composition and fermentation quality of fresh corn silages as a routine analysis method for feeding value evaluation to give advice to farmers.