Shell and Tube Heat Exchanger Performance Estimation by Changing Shell-side Fluid Characteristics (쉘-튜브 열교환기에서의 쉘쪽 유체의 특성에 따른 열교환기 성능 변화 예측 사례)

  • Baek, Seungwhan;Jung, Youngsuk;Cho, Kiejoo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.2
    • /
    • pp.27-37
    • /
    • 2019
  • The shell and tube heat exchangers installed in the propulsion system test complex (PSTC) at the Naro Space Center heats cryogenic helium to 500 K with a heat transfer oil. As the experimental helium outlet temperature was lower than expected (less than 100 K), the boundary layer effect of the heat transfer oil is predicted to be the cause of the performance deterioration. A computational fluid dynamics (CFD) analysis was performed to verify where the boundary layer effect exists; however, the boundary layer effect has no significant impact on the performance of the heat exchanger. An alternative method to improve the performance of the heat exchanger by changing the heat transfer oil has been discussed in this paper. The low viscosity and high thermal conductivity at high temperature (~500 K) of heat transfer oil at the shell-side are required to improve the thermal performance of the heat exchanger. The experimental performance of the heat exchanger, used to exchange heat between the cryogenic helium and hot heat transfer oil at the PSTC are summarized in this paper.

Effect of Optimal Humidification for Extremely Low Birth Weight Infants During Nasal Continuous Positive Airway Pressure (인공호흡기 가습기 적용방법이 초극소 저출생 체중아의 경비지속 기도 양압 환기법 유지기간에 미치는 영향)

  • Kim, Jung-Sook;Lee, Eun-Jung
    • Child Health Nursing Research
    • /
    • v.17 no.2
    • /
    • pp.145-152
    • /
    • 2011
  • Purpose: To evaluate the efficacy of Optimal humidification during Nasal Continuous Positive Airway Pressure (nCPAP) for Extremely Low Birth Weight Infant (ELBWI). Methods: The study design was a pre-test-post-test nonequivalent nonsynchronized quasi-experimental design. The participants were 218 ELBWI on nCPAP (experimental group: 102 and control group: 116). Data collection was conducted from January 2005 to April 2010. In order to measure and analyze the nCPAP duration, reintubation and nasal condition, Chi-square test and t-test were used. Results: Hypothesis 1, that the duration with nCPAP in the experimental group is longer than that of the control group and hypothesis 2-3, that the rate of reintubation and nasal problems in the experimental group are lower than the control group, were all supported as there were statistically significant differences between two groups. Conclusion: The findings suggest that the Optimal humidification in this study is an efficient intervention because it helps increase the last time of nCPAP with ELBWI and minimize complications. It is expected that Optimal humidification is beneficial and helpful in preventing and caring for respiratory problems in these infants.

Congenital central hypoventilation syndrome combined with Hirschsprung disease diagnosed in the neonatal period (신생아에서 진단된 Hirschsprung 병을 동반한 congenital central hypoventilation syndrome 1례)

  • Choi, Jin Hyun;Oh, Jin Hee;Kim, Jong-Hyun;Koh, Dae Kyun;Hong, Seung-Chul
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.4
    • /
    • pp.446-450
    • /
    • 2006
  • Congenital central hypoventilation syndrome (CCHS) or Ondine's curse is a very rare sleep disorder that is the result of a congenital failure of the autonomic control of ventilation caused by insensitivity of the chemoreceptor to hypercapnea during sleep. Gastrointestinal motility disorders, particularly a congenital megacolon (Hirschsprung disease) is often combined with CCHS. This combination can be explained by a defect in the migration of neuronal cells from the neural crest (neurocristopathy) during the intrauterine period. A diagnosis of CCHS is made by confirming the failure of adequate ventilation in response to hypercapnea and hypoxia during sleep and the exclusion of other diseases. Young infants frequently show atypical clinical courses, and their conditions are frequently complicated with the long-term sequela of hypoxemic episodes. Therefore, a high index of suspicion and active treatment with mechanical ventilation are important for reducing recurrent hypoxemic episodes in the neonatal period. This paper reports the follow up of a case of CCHS in a neonate who showed frequent intractable apnea and cyanosis and was given artificial mechanical ventilation during sleep.

A Study on the Effective Adjustment of Building Insulation Performance and the Application of the Night Purge Ventilation System for Low Energy Building Design (저에너지건축물 설계를 위한 건축물 단열성능의 효과적 조정과 야간외기 도입에 따른 에너지 시뮬레이션 연구)

  • Yun, Hyun-Su;Lee, Tae-Kyu;Kim, Jeong-Uk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.625-632
    • /
    • 2018
  • This study was done to reduce total energy demand based on resource shortage problems and to provide improvement points for more efficient adjustment of the high insulation standards for saving energy in Korea. The demand sensitivity was fully considered by varying the slope of each building. The energy performance of the building was maximized by the introduction of outdoor air at night. A final low-energy building model was developed with the two measures combined, and the short-term operation of the night-fuzzy ventilation system was simulated. The result showed a reduction of about 6 to 7 percent compared to the base model. The results could have many implications in terms of the need to conduct demand sensitivity analyses in architectural design.

Air-side Heat Transfer and Friction Characteristics of Fined-tube Heat Exchangers under Heating Condition (핀-관 열교환기의 난방운전 시 공기측 열전달 및 마찰특성)

  • Kwon, Young Chul;Chang, Keun Sun;Ko, Kuk Won;Kim, Young Jae;Park, Byung Kwon
    • Applied Chemistry for Engineering
    • /
    • v.17 no.5
    • /
    • pp.476-482
    • /
    • 2006
  • An experimental study has been performed to investigate the characteristics of air-side heat transfer and friction of a fined tube heat exchanger under heating conditions. Air enthalpy calorimeter was used to obtain the performance evaluation and analysis of the fined tube heat exchanger. Eight finned tube heat exchangers with slit fin, louver fin, and plain fin were used. The air-side heat transfer coefficient was calculated by the log-mean-temperature-difference. Air-side heat transfer and friction were presented in terms of j factor and friction factor on Reynolds number. From the experimental result, it was found that the variations of air-side heat transfer and friction of fined tube heat exchanger with the change of the fin configuration, row number, fin pitch, and tube circuit were obtained. j factor and friction factor decreased with Reynolds number increased. The tube circuit affected the air-side heat transfer and friction. In the case of slit and louver fin, j factor of 1st row was higher than that of 2nd row. But, with increasing Re, j factor was reversed. The characteristics of j factor and friction factor of 2nd row heat exchanger were different according to the kind of fins.

Prediction of Intubation after Bronchoscopy with Non-invasive Positive Pressure Ventilation Support in Patients with Acute Hypoxemic Respiratory Failure (급성 저산소혈증 환자에서 비침습적 양압환기 적용 하 기관지경 검사 후 기관 삽관의 예측 인자)

  • Song, Jae-Uk;Kim, Su-A;Choi, E Ryoung;Kim, Soo Min;Choi, Hee Jung;Lim, So Yeon;Park, So Young;Suh, Gee Young;Jeon, Kyeongman
    • Tuberculosis and Respiratory Diseases
    • /
    • v.67 no.1
    • /
    • pp.21-26
    • /
    • 2009
  • Background: Non-invasive positive pressure ventilation (NPPV) ensures adequate gas exchange during bronchoscopy in spontaneously breathing, hypoxemic patients, thus avoiding endotracheal intubation. However, in some patients, endotracheal intubation is eventually required after bronchoscopy. This study investigated the incidence of intubation and predictors of a need for emergency intubation prior to NPPV bronchoscopy initiation. Methods: On a retrospective basis, we reviewed the medical records of 36 patients (median age, 55 years; interquartile range [IQR], 43~65 years) with acute hypoxemic respiratory failure who required NPPV during bronchoscopy between January 2005 and October 2007. Results: All patients were hypoxemic (median $PaO_2/FiO_2$ ratio 155; IQR 90~190), but tolerated bronchoscopy with NPPV support. SOFA score and SAPS II score immediately before NPPV initiation were 4 (3~7) and 36 (30~42), respectively. Seventeen (47%) patients needed endotracheal intubation at a median time of 22 (2~50) hours after bronchoscopy. Patients who needed intubation after bronchoscopy had a higher in-hospital mortality (11 [65%] vs. 4 [21%], p=0.017). Upon multiple logistic regression analysis, the need for intubation after bronchoscopy was independently associated with a $P_aO_2/FiO_2$ ratio (OR, 0.961; 95% CI, 0.924~0.999; p=0.047) immediately before NPPV initiation for bronchoscopy. Conclusion: The severity of the hypoxemia immediately prior to NPPV initiation for bronchoscopy was associated with the need for intubation after bronchoscopy in patients with hypoxemic respiratory failure.

중부전력 북풍전변전소납입 275KV 450MVA 부하시 TAP 절환변압기

  • 등본광소;고추륭사;정천도부
    • 전기의세계
    • /
    • v.28 no.2
    • /
    • pp.14-22
    • /
    • 1979
  • 전력계통의 증대에 따라 변전소용 변압기도 대용량화되어 가고 있다. 변전소용 대용량 변압기의 경우 최대문제가 되는 것은 철도운송의 경우 운송한계에 있다. 일본의 철도는 협궤이기 때문에 운송능력이 작고 275KV 변압기의 경우 조립운송할 수 있는 한계용량은 종래 300MVA라고 되어 왔지만, 최근 기술의 진보와 신뢰성 향상 시책에 따라 450MVA까지도 철도운송을 하는 것이 가능케 되었다. 이와같은 사정때문에 당사는 이번에 중부 전력.북풍전변전소에 3상 60Hz, 275/15 4/31.5KV, 450/450/135MVA 변압기를 납품하였다. 본기는 초고압 변전소용으로는 일본에서 최대급의 것으로 여러가지의 특징을 가지고 있다. 그 주요점을 들면, (1) 철도에 의한 조립운송을 가능케 했다. 더우기 부하시 TAP 절환기를 본체 TANK에 조립해서 운통한다. (2) 일차 초고압 권선에는 선로단을 중앙에 배치한 HISERCAP 권선을 채용한다. (3) 당초 65Phon, 장래 55Phon의 저소음사양을 만족시키기 위해서 고효율의 송유풍냉식 저소음방열관을 사용했다. (4) 기기의 신뢰성을 높이기 위해 설계, 제조, 시험 검사 각면에 만전을 기했다. 그러나 그외에도 여러가지 연구가 추진되고 있으며 다음에 개요를 설명하고져 한다.

  • PDF

Chronic Obstructive Pulmonary Disease and Sleep Disorder (만성폐쇄성폐질환과 수면장애)

  • Kim, Sei Won;Kang, Hyeon Hui
    • Sleep Medicine and Psychophysiology
    • /
    • v.27 no.1
    • /
    • pp.8-15
    • /
    • 2020
  • Sleep disorder in chronic obstructive pulmonary disease (COPD) is common and typically is associated with oxygen desaturation. The mechanisms of desaturation include hypoventilation and ventilation to perfusion mismatch. Despite the importance of sleep in patients with COPD, this topic is under-assessed in clinical practice. Impaired sleep quality is associated with more severe COPD and may contribute to worse clinical outcomes. Recent data have indicated that specific respiratory management of patients with COPD and sleep disordered breathing improves clinical outcomes. Clinicians managing patients with COPD should pay attention to and actively manage symptoms of comorbid sleep disorders. Management of sleep-related problems in COPD should particularly focus on minimizing sleep disturbance.

A Study on Optimal Voltage Algorithm for Distribution System Interconnected with Photovoltaic System (태양광전원이 연계된 배전계통의 최적전압운용 알고리즘 개발)

  • Son, Joon-Ho;Rho, Dae-Seok
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05a
    • /
    • pp.67-70
    • /
    • 2010
  • 국가차원의 신 재생에너지 활성화 방안에 따라 태양광, 풍력발전 등의 대규모 분산전원 단지의 도입이 이루어지고 있으며, 현재 배전계통의 전압조정 방법은 배전용 변전소의 부하시 탭 절환기(Under Load Tap Changer, 이하 ULTC)와 배전선로의 선로전압조정장치(Step Voltage Regulator, 이하 SVR)로 수용가에 규정전압(220${\pm}$6%)을 만족시키는 전압을 공급한다. 하지만 대규모의 태양광, 풍력 등의 분산 전원이 배전계통에 도입되는 경우, 전력품질[과전압/저전압]의 문제가 발생된다. 본 논문에서는 부하율에 따라 변화된 LDC 정정치를 적용 및 시뮬레이션을 통한 수용가 직하 및 말단의 규정전압(220${\pm}$6%) 즉 207V이하의 저전압, 233V이상의 과전압 여부를 검증함으로써 전력품질을 유지 할 수 있는 태양광전원이 연계된 배전계통의 최적전압운용 알고리즘을 개발하였다.