• Title/Summary/Keyword: 저층 구조물

Search Result 132, Processing Time 0.029 seconds

Structural Design And Analysis of Haeundae Doosan We've The Zenith (해운대 두산 위브 더 제니스 구조설계)

  • Park, Ki-Hong;Park, Suk-Jin
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.93-98
    • /
    • 2008
  • Haeundae Doosan We've The Zenith project is adjacent to Suyoung-bay, now it is in the process of excavation and foundation work. The main use of the tower is residence which height is 300m and 80 floor, the highest residential reinforced concrete building through the Orient. It is comprised of 3 high- rised buildings and 1 low-rised building, the basement is 230m wide and 200m length sized mass structure. The lateral resistance system is acted effectively against the lateral load and satisfactorily against the wind vibration by the 4 direction extension of the center core wall($700{\sim}800mm$ thickness) and reinforced concrete column set around the slab. Flat-plate slab system(250mm thickness) is adjusted for the slab system and it enables effective work process and shortening the working term by minimizing the ceiling height and not needing to install perimeter beam and drop panel. The strength and serviceability of the structure is able to be monitored and estimated constantly through the health monitoring system during the construction and after the construction.

  • PDF

Vibration Characteristics of a Three-Story Reinforced Concrete Building Before and After Damage (3층 철근콘크리트조 건물의 손상전후의 진동특성)

  • Yoon, Sung-Won;Park, Yong;Ji, Jung-Hwan;Lim, Jae-Hwi;Jang, Dong-Wo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.9 no.3
    • /
    • pp.59-66
    • /
    • 2009
  • Dynamic characteristics such as frequency and damping ratio in the ambient state of building has been progressed in domestic and foreign. However, there has not been any deep research of dynamic characteristics of full-scale structure using vibration measurement of the building damaged up to failure. Dynamic characteristics of three-story reinforced concrete building was evaluated before and after it was damaged by using a actuator. Dynamic characteristics is reviewed and compared with previous study. Ambient vibration and human excitation test were applied. After 120mm horizontal displacement by actuator, frequency of long and short direction is reduced to 34.3%, 33.7% and damping ratio is reduced to 36.5%, 19.5% respectively.

  • PDF

Seismic Isolation Effects According to Set up the Isolation Period in the Medium and Low-rise Framed Building (중.저층골조에서 면진주기 설정에 따른 면진효과)

  • Chun, Young-Soo;Hur, Moo-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.6
    • /
    • pp.93-99
    • /
    • 2010
  • Seismic isolation offers an attractive approach for reducing seismic loads in the building and its components. This paper deals with the seismic isolation effects due to variation in period ratio between superstructure and isolation layer of the building. Seismic isolation effects of the moment-resisting frames with the various period ratio were studied by nonlinear time history analysis, and the guidelines on the stiffness ratio of the superstructure and isolation layer of the building for the effective seismic isolation follow from the results of this study. It is recommended that the isolation period should be greater than 2.5 times of that of the superstructure for the effective seismic isolation.

Development of Frictional Wall Damper and Its Analytical Applications in R/C frame Structures (벽식마찰감쇄기의 개발 및 R/C 골조구조물에의 해석적 적용)

  • 조창근;박문호;권민호;강구수;서상길
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.718-725
    • /
    • 2002
  • A wall type friction damper is newly Proposed in this paper to improve the performance of R/C framed structures under earthquake loads. Although traditional dampers are usually placed as bracing members, the application ot bracing-type dampers into R/C structures is not as simple as those of steel structures due to the connection between R/C members and dampers and the stress concentration in connection region. Proposed damper is consisted of Teflon-sheet slider and R/C shear wall. The damper can also avoid stress concentration and reduce P-Δ effect. To evaluate the performance of proposed damper, nonlinear dynamic analyses are carried on 10 story and 3 bay R/C structures with numerical model for the damper. It is shown that the damper reduces the inter-story drifts and the time-historic responses; especially the damper prevents from forming plastic hinges on the lower columns.

Hydroacoustic Investigation on the Distribution and Migration Behavior of Fish (어군탐지기에 의한 어군의 분포와 생태계측에 관한 연구)

  • 이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.28 no.4
    • /
    • pp.337-346
    • /
    • 1992
  • Hydroacoustic surveys were conducted in the East China Sea, in the summers of 1990-1991 to investigate the distribution and migration behavior of fish, such as the diel changes in the distributions of fish, the thermoselection behavior of fish, and the fish reactions to a surveying vessel. The hydroacoustic observations were taken with a scientific echo sounder operating at 50kHz and a microcomputer-based echo processor. Fish samples were collected by bottom trawling and temperature was measured with a DBT system. The patterns of fish distributions were compared with the vertical profiles of water temperature. The results obtained can be summarized as follows: 1. The time series of hydroacoustic observations on the downward migration at dawn in the central region of East China Sea showed that the migration rate was 0.24 m/min. In this region, most of the fish collected by bottom trawling during the surveys were squid (Photologio edulis f. budo) and horse mackeral (Trachurus japonicus). 2. The hydroacoustic observations, which together associated with temperature data, indicated that squid and horse mackeral concentrated nocturally in a narrow vertical band of thermocline, particularly in summer when the survey region was strongly stratified. This result suggest that the nocturnal vertical distribution of these species evidently is controlled by temperature. 3. When the survey vessel, that is running at a speed of 11 knots, has suddenly stopped, the fish which concentrated beneath the transducer showed a strong avoidance reaction in the form of rapid downward migration. After a few minutes, the descending reaction disappeared and the fish slowly began the upward migration toward their original swimming positions. Trawl data suggest that the fish, which showed the avoidance reaction, was Liparis tessellatus.

  • PDF

Dynamic Analysis for Base Isolated Structure with Shear Keys (쉬어키를 가진 면진건축물의 동적해석)

  • Han, Duck-Jeon;Kim, Tae-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.1 s.23
    • /
    • pp.45-53
    • /
    • 2007
  • Recently, high-rise base isolated building structures with shear keys are often constructed in Japan which frequently occurs earthquakes. High-rise buildings are less damaged because those buildings have longer natural period than md or low rise buildings. The shear key is device that prevents the base isolators operating by the wind loads not by the earthquake loads. In case of big base shear force acts on the shear keys by earthquake, this device is broken and base isolator is operated. Therefore, seismic intensities play a role in acting on the shear keys. If wind loads are hither than the earthquake loads, the shear keys designed by wind loads are not operated in earthquakes. So, the requirements of shear keys in high-rise base isolated building structures must be examined in Korea with moderate seismic legions. In this study shear keys are applied with 5 and 15 stories base isolated building structures and investigated their dynamic responses to original and 1/2 scale downed El Centre NS(1940) ground motions. The results show that the yield shear forces of the shear keys affect significantly the dynamic behavior of base isolated building structures

  • PDF

Response Modification Factors of Inverted V-type Special Concentrically Braced Frames (역V형 특수가새골조의 반응수정계수)

  • 김진구;남광희
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.29-37
    • /
    • 2004
  • The overstrength factor and the ductility factor are the two important factors that determine response modification factors used in current seismic codes, In this paper the overstrength and ductility factors of special concentric braced frames are determined by performing pushover analysis of model structures with various stories and span lengths. and by using those factors the response modification factors are obtained. According to the analysis results. the overstrength and the ductility factors are larger than the values proposed by the codes in low-rise structures. and the opposite is true in medium to high-rise structures, It is also found that the factors increase as the height of structures decreases and the span length increases.

Seismic Responses of Wall-Slab Apartment Building Structures Built on the Soft Soil Layer Considering the Stiffnesses of a Foundation-Soil System (연약지반의 기초지반강성을 고려한 벽식구조 아파트의 지진응답)

  • 김지원;김용석
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.3
    • /
    • pp.19-27
    • /
    • 2001
  • In this seismic analyses of structures, it is well recognized that the effects of soil-structure interaction can not be ignored and seismic responses of a structure taking into account the stiffnesses of a foundation-soil system show the significant difference from those with a rigid base. However, current seismic analyses of apartment building structures were carried out with the rigid base ignoring the characteristics of the foundation and the properties of the underlying soil. In this study, seismic analyses of wall-slob type apartment buildings which have a particular structural type were carried out taking into account the soft soil layer comparing seismic response spectra of a flexible base with those of a rigid base and UBC-97. Low-rise or middle height wall-slab type apartment buildings built on the deep soft soil layer showed a rigid body motion with the reduced seismic responses due to the base isolation effect, indicating that it is considerably safe but uneconomical to utilize the design spectra of UB-97 for the seismic design of wall-slab type apartment buildings due to conservative design.

  • PDF

Use of a Genetic Algorithm to Predict the Stiffness Reductions and Retrofitting Effects on Structures Subjected to Seismic Loads (지진하중을 받은 구조물의 유전알고리즘 기반 강성저하 및 보강 효과 추정)

  • Lee, Jae-Hun;Ahn, Kwang-Sik;Lee, Sang-Youl
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.3
    • /
    • pp.193-199
    • /
    • 2020
  • This study examines a method for identifying stiffness reductions in structures subjected to seismic loads and retrofitting effects using a combination of the finite element method and an advanced genetic algorithm. The novelty of this study is the application of seismic loading and its response to anomalies in the tested structure. The technique described in this study may enable not only detection of damaged elements but also the identification of their locations and the extent of damage due to seismic loading. To demonstrate the feasibility of the method, the advanced genetic algorithm is applied to frame and truss bridge structures subjected to El Centro and Pohang seismic loads. The results reveal the excellent computational efficiency of the method and its ability to prevent severe damage from earthquakes.

Seismic Retrofit of Reinforced Concrete Structures Using Steel Braces and Moment Frames (가새와 강골조를 이용한 저층 RC 구조물의 내진보강)

  • Huynh, Chanh Trung;Park, Kyoung-Hoon;Kim, Jin-Koo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.5
    • /
    • pp.509-516
    • /
    • 2010
  • In this study a seismic retrofit scheme for the reinforced concrete moment framed structures was investigated using steel bracing and moment frames. The analysis model structure is a 3-story 3-bay moment frame structure designed only for gravity load. The stress/strain concentration in brace-RC frame connection was investigated using finite element analysis. To prevent premature joint failure, steel moment frames were placed inside of middle bay of the RC frame. Two types of braces, steel braces and buckling restrained braces(BRBs), were used for retrofit, and the ductility and the strength of the structure before and after the retrofit were compared using nonlinear static and dynamic analyses. According to the analysis results, the strength and ductility of the structure retrofitted by the moment frames and braces increased significantly. The added steel frame did not contribute significantly to the increase of lateral strength mainly because the size is relatively small.