• Title/Summary/Keyword: 저장실험장치

Search Result 495, Processing Time 0.029 seconds

A study on the bonding strength of co-cured T800/epoxy composite-aluminum single lap joint according to the forming and additional pressures (동시 경화법으로 제조된 T800/에폭시 복합재료-알루미늄 단면겹치기조인트의 성형압력 및 부가압력에 따른 접착강도에 관한 연구)

  • Son, Dae-Sung;Bae, Ji-Hun;Chang, Seung-Hwan
    • Composites Research
    • /
    • v.24 no.5
    • /
    • pp.23-28
    • /
    • 2011
  • In this paper, the bonding strengths of co-cured T800 carbon/epoxy composite-aluminum single lap joints with and without additional pressures were investigated using the pressure information induced by the fiber tension during a filament winding process. The specimens of all the tests were fabricated by an autoclave vacuum bag de-gassing molding being controlled forming pressures (absolute pressures of 0.1MPa, 0.3MPa and 0.7MPa including vacuum). A special device which can act uniform additional pressures on the joining part of the single lap joint specimen was designed to measure the bonding strengths of composite-aluminum liners of type III hydrogen pressure vessel fabricated by a filament winding process. After the three different additional pressures (absolute pressures of 0.1MPa, 0.3MPa and 0.7MPa) were applied to the specimens the effect of the additional pressures on the bonding strengths of the co-cured single-lap joints were evaluated.

Virtual Machine Code Optimization using Profiling Data (프로파일링 데이터를 이용한 가상기계 코드 최적화)

  • Shin, Yang-Hoon;Yi, Chang-Hwan;Oh, Se-Man
    • The KIPS Transactions:PartA
    • /
    • v.14A no.3 s.107
    • /
    • pp.167-172
    • /
    • 2007
  • VM(Virtual Machine) can be considered as a software processor which interprets the machine code. Also, it is considered as a conceptional computer that consists of logical system configuration. But, the execution speed of VM system is much slower than that of a real processor system. So, it is very important to optimize the code for virtual machine to enhance the execution time. Especially the optimizer for a virtual machine code on embedded devices requires the highly efficient performance to the ordinary optimizer in the respect to the optimized ratio about cost. Fundamentally, functions and basic blocks which influence the execution time of virtual machine is found, and then an optimization for them nay get the high efficiency. In this paper, we designed and implemented the optimizer for the virtual(or abstract) machine code(VMC) using profiling. Firstly, we defined the profiling information which is necessary to the optimization of VMC. The information can be obtained from dynamically executing the machine code. And we implemented VMC optimizer using the profiling information. In our implementation, the VMC is SIL(Standard Intermediate Language) that is an intermediate code of EVM(Embedded Virtual Machine). Also, we tried a benchmark test for the VMC optimizer and obtained reasonable results.

A study on the underwater energy harvesting characteristics of a funnel type macro fiber composite energy harvester (수중에서 퍼넬형 macro fiber composite 에너지 하베스터의 에너지 수확 특성)

  • Jongkil Lee;Jinhyo An
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.1
    • /
    • pp.57-66
    • /
    • 2023
  • In this paper, it was investigated how the amount of energy harvesting will be varied from the FTEH which has inlet area is wider than outer area and attaching cantilever type MFC (Macro Fiber Composite) using by theoretical and experimental approaches. When MFC length increased 50 % vibration displacement also increased 3.5 times. When thickness decreased vibration displacement increased 30.9 times. In underwater tank experiments FTEH with spiral screw, flexible support, vertical direction fabrication cases showed maximum energy harvesting more 5 times than the case of MFC installed horizontally without spiral screws and on rigid supports. When the flow speed of 0.24 m/s FTEH's optimal resistance applied 4,10 kΩ, energy storage in the capacitor was measured 4 ㎼·s during 350 seconds. It was confirmed that the charging energy can be increased by lengthening the capacitor charging time of the large-area MFC installed vertically on the flexible support at high flow speed.

A Study of Optimal Model for the Circuit Configuration of Korean Pulsatile Extracorporeal Life Support System (T-PLS) (한국형 박동식 생명구조장치(T-PLS) 순환회로를 위한 최적화 모델 연구)

  • Lim Choon Hak;Son Ho Sung;Lee Jung Joo;Hwang Znuke;Lee Hye Won;Kim Kwang Taik;Sun Kyung
    • Journal of Chest Surgery
    • /
    • v.38 no.10 s.255
    • /
    • pp.661-668
    • /
    • 2005
  • Background: We have hypothesized that, if a low resistant gravity-flow membrane oxygenator is used, then the twin blood sacs of TPLS can be located at downstream of the membrane oxyenator, which may double the pulse rate at a given pump rate and increase the pump output. The purpose of this study was to determine the optimal configuration for the ECLS circuits by using the concept of pulse energy and pump output. Material and Method: Animals were randomly assigned to 2 groups in a total cardiopulmonary bypass model. In the serial group, a conventional membrane oxygenator was located between the twin blood sacs. In the parallel group, the twin blood sacs were placed downstream of the gravity-flow membrane oxygenator. Energy equivalent pressure (EEP) and pump output were collected at pump-setting rates of 30, 40, and 50 BPM. Result: At the given pump-setting rate, the pulse rate was doubled in the parallel group. Percent changes of mean arterial pressure to EEP were $13.0\pm1.7,\; 12.0\pm1.9\;and\;7.6\pm0.9\%$ in the parallel group, and $22.5\pm2.4,\; 23.2\pm1.9,\;and\;21.8\pm1.4\%$ in the serial group at 30, 40, and 50 BPM of pump-setting rates. Pump output was higher in the parallel circuit at 40 and 50 BPM of pump-setting rates $(3.1\pm0.2,\;3.7\pm0.2L/min\;vs.\;2.2\pm0.1\;and\;2.5\pm0.1L/min,\;respectively,\;p=0.01)$. Conclusion: Either parallel or serial circuit configuration of the ECLS generates effective pulsatility. As for the pump out, the parallel circuit configuration provides higher flow than the serial circuit configuration.

Design and Implementation of a File System that Considers the Space Efficiency of NVRAM (비휘발성 메모리의 공간적 효율성을 고려한 파일 시스템의 설계 및 구현)

  • Hyun Choul-Seung;Baek Seung-Jae;Choi Jong-Moo;Lee Dong-Hee;Noh Sam-H.
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.33 no.9
    • /
    • pp.615-625
    • /
    • 2006
  • Nonvolatile memory technology is evolving continuously and commercial products such as FeRAM and PRAM are now challenging their markets. As NVRAM has properties of both memory and storage, it can store persistent data objects while allowing fast and random access. To utilize NVRAM for general purpose storing of frequently updated data across power disruptions, some essential features of the file system including naming, recovery, and space management are required while exploiting memory-like properties of NVRAM. Conventional file systems, including even recently developed NVRAM file systems, show very low space efficiency wasting more than 50% of the total space in some cases. To efficiently utilize the relatively expensive NVRAM, we design and implement a new extent-based space-thrifty file system, which we call NEBFS (NVRAM Extent-Based File System). We analyze and compare the space utilization of conventional file systems with NEBFS and validate the results with experimental results observed from running the file system implementations on a system with actual NVRAM installed as well as on systems emulating NVRAM. We show that NEBFS has high space efficiency compared to conventional file systems.

A Study on the Heat Storage Utilizing Phase Change of Salt Hydrates in Vertical Piped-Storage System (수직관형(垂直管形) 축열조(蓄熱槽)에서의 수화염류(水化塩類)의 상변화(相変化)를 이용(利用)한 열저장(熱貯藏)에 관(関) 연구(硏究))

  • Yon, Kwang Seok;Cha, Gyun Do
    • Journal of Biosystems Engineering
    • /
    • v.9 no.2
    • /
    • pp.74-80
    • /
    • 1984
  • Storage materials for a minimized storage system should be able to store much energy in small quantities, and to solve such a problem, salt hydrates such as CALCIUM CHLORIDE, SODIUM SULFATE, SODIUM PHOSPHATE etc. were considered as most suitable storage media in which phase change phenomena take place at low temperature. Therefore those salt hydrates were used as storage media in this study, and piped-storage tanks were manufactured vertically for the experiment. The characteristics of thermal storage media were investigated and the results are summarized as follows: 1. From the experiment of radial temperature distribution of vertical piped-storage system, the latent heat phenomenon did not occur in all storage media during heating process because of generations of heat due to the reduction in the number of water molecules. However, among those storage media CALCIUM CHLORIDE had most remarkable latent heat phenomenon during cooling process. Therefore CALCIUM CHLORIDE was considered as most suitable storage media. 2. Heat quantity transferred to the storage media was the largest in case of CALCIUM CHOLORIDE under the same conditions during heating and cooling process.

  • PDF

Application of MicroPACS Using the Open Source (Open Source를 이용한 MicroPACS의 구성과 활용)

  • You, Yeon-Wook;Kim, Yong-Keun;Kim, Yeong-Seok;Won, Woo-Jae;Kim, Tae-Sung;Kim, Seok-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.51-56
    • /
    • 2009
  • Purpose: Recently, most hospitals are introducing the PACS system and use of the system continues to expand. But small-scaled PACS called MicroPACS has already been in use through open source programs. The aim of this study is to prove utility of operating a MicroPACS, as a substitute back-up device for conventional storage media like CDs and DVDs, in addition to the full-PACS already in use. This study contains the way of setting up a MicroPACS with open source programs and assessment of its storage capability, stability, compatibility and performance of operations such as "retrieve", "query". Materials and Methods: 1. To start with, we searched open source software to correspond with the following standards to establish MicroPACS, (1) It must be available in Windows Operating System. (2) It must be free ware. (3) It must be compatible with PET/CT scanner. (4) It must be easy to use. (5) It must not be limited of storage capacity. (6) It must have DICOM supporting. 2. (1) To evaluate availability of data storage, we compared the time spent to back up data in the open source software with the optical discs (CDs and DVD-RAMs), and we also compared the time needed to retrieve data with the system and with optical discs respectively. (2) To estimate work efficiency, we measured the time spent to find data in CDs, DVD-RAMs and MicroPACS. 7 technologists participated in this study. 3. In order to evaluate stability of the software, we examined whether there is a data loss during the system is maintained for a year. Comparison object; How many errors occurred in randomly selected data of 500 CDs. Result: 1. We chose the Conquest DICOM Server among 11 open source software used MySQL as a database management system. 2. (1) Comparison of back up and retrieval time (min) showed the result of the following: DVD-RAM (5.13,2.26)/Conquest DICOM Server (1.49,1.19) by GE DSTE (p<0.001), CD (6.12,3.61)/Conquest (0.82,2.23) by GE DLS (p<0.001), CD (5.88,3.25)/Conquest (1.05,2.06) by SIEMENS. (2) The wasted time (sec) to find some data is as follows: CD ($156{\pm}46$), DVD-RAM ($115{\pm}21$) and Conquest DICOM Server ($13{\pm}6$). 3. There was no data loss (0%) for a year and it was stored 12741 PET/CT studies in 1.81 TB memory. In case of CDs, On the other hand, 14 errors among 500 CDs (2.8%) is generated. Conclusions: We found that MicroPACS could be set up with the open source software and its performance was excellent. The system built with open source proved more efficient and more robust than back-up process using CDs or DVD-RAMs. We believe that the operation of the MicroPACS would be effective data storage device as long as its operators develop and systematize it.

  • PDF

Characteristics of $TiH_2$ under High Pressure (고압하에서 $TiH_2$의 특성화 연구)

  • Kim, Young-Ho
    • Journal of the Mineralogical Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.72-78
    • /
    • 1992
  • The Earth outer core accomodates moderately considerable amount of lighter elements than pure iron itself. Hydrogen is one of the possible candidates of minor constituents in the outer core. It would be worth while to extend for the pressure effect on the solubility of hydrogen in the metal-hydrides including iron hydride. In view of hydrogen being one of the potential substitutes for petroleum, searching a more efficient way for storing hydrogen in the form of hydrides is of considerable value. For two purposes, $TiH_2$was selected among lot of hydrides for its characteristics under pressure and temperature. There have been two kinds of experiment carried out on $TiH_2$ under different experimental conditions. As one of these attempts, polycrystalline $TiH_2$ was loaded up to 15 GPa stepwise at the constant temperature 500${\circ}$ using a piston-cylinder diamond anvil cell equipped with a miniature furnace of an electric power supply. The X-ra diffraction technique was employed on the quenched samples after the simultaneous high pressure and temperature treatments. During these high pressure-temperature runs, and irreversible phase of $TiH_2$ has been observed at the pressures higher than 11.3 GPa, which would be assigned to the orthorhombic crystal system as one of the new phase(s) of $TiH_2$. Molar volume change on this phase transition is ∼10%.

  • PDF

Effectiveness and Characteristics Analysis of Inertia Driving on Fuel-Cut Zones in Urban Highway (도시부도로 연료차단구역의 관성주행 특성 및 효과분석)

  • Choi, Eun Jin;Kim, Eungcheol;Kim, Yong Jin;Yang, Joo Young
    • Journal of Korean Society of Transportation
    • /
    • v.33 no.1
    • /
    • pp.40-49
    • /
    • 2015
  • In this study, the effects of inertial driving on a fuel-cut zone were analyzed by measuring the instantaneous variations of fuel consumption and speed. Thirteen sites with 2-8% downhill slopes were selected for the vehicle experiments. The vehicles were driven on the sites in two different driving modes, and the various vehicle states were measured using OBD under driving. For the analysis of the effects of inertial driving, the characteristics of fuel consumption, speed, and rpm were compared between normal and inertial driving. As a result, the fuel consumption was reduced from 24% to 78% according to the downhill grade. The amount of fuel consumption reduction was about 30cc for driving 500m downhill. Fuel cost savings amounting to 35 billion won can be achieved if inertial driving will be done in the case of Munemi-ro3. It is also believed that the reduced fuel consumption and vehicle speed through inertial driving will have considerable environmental and safety benefits.

Measurement of Mutual Solubility of High-pressure Gaseous Fire Extinguishing Agents(HFCs) and Nitrogen (고압가스계 소화약제(HFCs계열)와 질소의 상호용해도 측정)

  • 임종성;박지영;이병권;김재덕;이윤용
    • Fire Science and Engineering
    • /
    • v.16 no.3
    • /
    • pp.26-31
    • /
    • 2002
  • Bromotrifluoromethane(halon-1301) and bromochlorodifluoromethane(halon-1211) have been widely used as a clean fire extinguishing agents due to their outstanding properties. However, production and use of halon are currently being phased out under an international agreements Montreal Protocol because of global environmental concerns and HFCs have been considered as promising alter-natives for the replacement of halon since their ozone depletion potentials are low. The vapor-liquid equilibrium data are required as important basic information in evaluating the solubility of clean fire extinguishing agents and determining their optimal compositions. In this work, we chose HFCs such as HFC-22 HFC-125, and HFC-l34a for gaseous fire extinguishing agents and nitrogen as a pressurization gas for a proper jet velocity of these agents. Phase equilibria for binary mixtures of nitrogen/HFC-22, nitrogen/HFC-125, and nitrogen/HFC-l34a were measured in the temperature range from 283.15K to 303.15K. For equilibrium measurement, we used a circulation type apparatus in which both vapor and liquid phases were continuously recirculated. The experimental data were relatively well correlated with the Peng-Robinson equation of state with Wong-Sandier mixing rules.