• Title/Summary/Keyword: 저온시험

Search Result 628, Processing Time 0.031 seconds

Performance Test of the Stirling Cryocooler for Cooling of the Infrared Detectors (적외선 센서 냉각용 스터링 냉동기의 성능시험)

  • 고득용;박성제;김효봉;염한길;김홍국;김남환
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 1999.02a
    • /
    • pp.202-206
    • /
    • 1999
  • This paper presents operating process of the Stirling cryocooler and results obtained with the performance test for Signal Usfa UP 7075 Stirling cryocooler. An experimental study was carried out to develop the more reliable Stirling cryocooler. The cooldown characteristics and load characteristics are described. The lowest temperature measured in the Stirling cryocooler wa 62.5K and the cooling capacity at the optimum operating condition was 0.4W at 77K. At that time, carnot COP was 0.024.

  • PDF

Development of Reduced Temperature Solid Oxide Fuel Cells and Test of a Short Stack (저온형 고체산화물 연료전지의 개발과 이를 이용한 소형 스택의 성능 시험)

  • 유영성;박진우;임희천;이규창;조남웅
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2003.05a
    • /
    • pp.649-653
    • /
    • 2003
  • 일반적으로 연료전지에는 알카리형(AFC)과 인산형(PAFC), 고분자형 연료전지(PEMFC) 등과 같이 비교적 저온에서 동작되는 연료전지와 고온형으로 $650^{\circ}C$에서 정온 동작되는 용융탄산염형 연료전지(MCFC)와 운전온도가 약 500~100$0^{\circ}C$로 폭넓게 적용될 수 있는 고체산화물 연료전지(혹은 고체전해질 연료전지, Solid Oxide Fuel Cell, SOFC)가 있다.(중략)

  • PDF

Speed-Torque Characteristics of the HTS Squirrel Gage Induction Motor (고온초전도 농형유도전동기의 속도-토크 특성시험)

  • 심정욱;박명진;이광연;차귀수;이지광
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.236-238
    • /
    • 2003
  • The speed-torque characteristics of the squirrel cage induction motor is determined by the rotor resistance. This paper presents the fabrication and test results of an HTS induction motor. Conventional end rings and short bars were replaced with HTS tapes in the rotor. Test result shows that the speeds of the HTS induction motor were the same with synchronous speed up to 10Nm.

  • PDF

Cooling Test of The HTS Power Cable (초전도케이블 냉각시험)

  • 염한길;고득용;홍용주;김익생;김춘동;김도형
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.295-297
    • /
    • 2003
  • Cryogenic systems is requirement for the operation of HTS power cables. In general, HTS power cables require temperature below 77K, a temperature that can be achieved from the liquid nitrogen or sub-cooled LN2. HTS power cable is needed for sufficient refrigeration to overcome its low temperature heat loading. This loading typically comes in two forms : (1) heat leaks from the surroundings and (2) internal heat generation. This paper is a explanation for the cooling test of 10m HTS power cable.

  • PDF

Transportation Current Test for 1 MVA HTS Transformer (1MVA 초전도 변압기 전류 통전 시험)

  • 박정호;송희석;김우석;김성훈;이동근;최경달
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.41-44
    • /
    • 2003
  • We manufactured double pancake type windings with BSCCO wire for 1MVA HTS transformer. To verify cracks of HTS wire and performance of manufactured windings, the transportation current was measured. In this paper, we present result of the transportation current test as a DC current and compare a drop of current performance of HTS wire due to tension and rounding during the manufacturing with technical data. We obtained good results and this will be useful for another manufacturing of HTS winding

  • PDF

Ground High/Low Temperature Test for FA-50 Aircraft (FA-50 경공격기 전기체 지상 고/저온시험)

  • Ahn, Jong Hoon;Kim, Tae Ho;Woo, Seung Cheol;Cho, Young Kyun;Kim, Do Wan
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.6 no.1
    • /
    • pp.41-46
    • /
    • 2010
  • The ground high/low temperature test objective is to check the normal ground operation of FA-50 aircraft in the extreme ground ambient conditions. The aircraft was exposed in climatic conditions of the basic climatic category according to the MIL-HDBK-310. For verified normal operation in the extreme high temperature, the high temperature test was performed in the hot regional type conditions and accentuated solar radiation heat. This test was performed at the test chamber in ADD where is in Haemi. This paper was described about the test procedure of FA-50 high/low temperature including preparation, testing and results.

  • PDF

수소 배기용 저온 흡착(Cryo-Sorption) 펌프의 열설계

  • 조용섭;최병호
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.45-45
    • /
    • 1999
  • 한국원자력연구소에서 개발중인 KSTAR 중성입자입사 (NBI) 가열장치의 이온원을 시험하기 위한 진공 챔버 (높이 1.2m, 폭 1.2m, 길이 2.4m)의 수소 배기는 저온 흡착 펌프를 제작하여 이용할 계획이다. 흡착제는 활성탄으로 하고, 흡착제의 냉각은 20K 12W Cold Head를 이용한다. 이 흡착제가 부착된 무산소동판을 액체 질소로 냉각된 Chevron Baffle로 열차폐한다. 이 흡착제가 수소를 배기하기 위해서는 15K 이하로 냉각이 되어야 하므로, 이에 대한 열설계가 중요하다. 흡착판에 가해지는 열부하를 평가하고, 이 열부하에서 흡착판 온도가 15K 이하가 되도록 열설계를 수행하였다. 열부하 중 가장 큰 것은 Ghevron을 통해 들어오는 복사열로, Chevron의 복사율 및 난반사도에 따라 MOnte Calro 법 전산코드를 작성하여 복사열을 계산하였다. 크기 500mm x 400mm인 흡착판에 대한 시험 결과를 바탕으로 열설계에 대한 타당성 검증 및 크기 800mm x 1400mm인 흡착판에 대해 열설계 내용에 대해 발표한다.

  • PDF

수소 배기용 저온 흡착 (Cryo-Sorption) 펌프의 열설계

  • 조용섭;최병호
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.127-127
    • /
    • 1999
  • 한국원자력연구소에서 개발중인 KSTAR 중성입자입사(NBI) 가열장치의 이온원을 시험하기 위한 진공챔버(높이 1.2m, 폭 1.2m, 길이 2.4m)의 수소 배기는 저온 흡착펌프를 제작하여 이용할 계획이다. 흡착제는 활성탄으로 하고, 흡착제의 냉각은 20K 12W Cold Head를 이용한다. 이 흡착제가 부착된 무산소동판을 액체 질소로 냉각된 Chevron Baffle로 열차폐한다. 이 흡착제가 수소를 배기하기 위해서는 15K 이하로 냉각이 되어야 하므로, 이에 대한 열설계가 중요하다. 흡착판에 가해지는 열부하를 평가하고, 이 열부하에서 흡착판 온도가 15K 이하가 되도록 열설계를 수행하였다. 열부하 중 가장 큰 것은 Chevron을 통해 들어오는 복사열로 Chevron의 복사율 및 난반사도에 따라 Monter Carlo법 전산 코드를 작성하여 복사열을 계산하였다. 크기 500mmx400mm인 흡착판에 대한 시험 결과를 바탕으로 열설계에 대한 타당성 검증 및 크기 800mmx1400mm인 흡착판에 대해 열설계 내용에 대해 발표한다.

  • PDF

원자로 압력용기 감시시험용 충격시험시스템 구축

  • 주용선;박대규;안상복;홍권표;이기순
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.118-123
    • /
    • 1998
  • 원자로 압력용기 재료로 사용되고 있는 ASTM SA508 및 SA533 계열의 재료는 결정구조가 체심입방격자(bcc)로서 시험온도별 최대흡수에너지(USE)에 대한 선도를 그리면 고온에서는 연성이 크고, 저온에서는 취성이 큰 전형적인 “S”자 형태의 Cv-천이온도곡선으로 나타난다. 그리고 조사전과 조사후의 연성-취성천이온도곡선을 흡수에너지값이 30ft-lb 또는 50ft-lb인 지점에석 비교해보면 재료의 조사취화(radiation embrittlement)현상으로 온도가 높은 쪽으로 이동됨을 알 수 있으며, 이러한 온도의 이동값은 원자로의 운전수명과 밀접한 관련이 있다. 따라서 조사전후의 흡수에 너지값에 따른 온도변화량를 정확하게 산출하기 위해서는 시편의 온도를 조절하는 장치 및 시편을 아주 짧은 시간내에 충격시험기의 앤빌까지 장전하는 장치 둥의 충격시험시스템 구축은 매우 중요하다. 이에 조사계시험시설(IMEF)에서는 원자로 압력용기 감시시험에 대한 충격시험시스템을 구축하였고, 이의 내용은 감시시험 수행에 기준이 되는 ASTM El85-82 및 과학기술처 고시 제 92-20호의 세부내용을 충분하게 만족시키는 것으로 확인되었으며, 이렇게 확인된 내용들은 현재 국내에서 수행되고 있는 감시시험에 적극적으로 활용되고 있다.

  • PDF

Influence of a Flexibilizer on Physical Properties of Crumb Rubber Modified Asphalt Sealants (폐타이어 고무분말 개질 아스팔트 실란트의 물리적 특성에서 유연제의 영향)

  • Kim, Jong-Seok
    • International Journal of Highway Engineering
    • /
    • v.11 no.3
    • /
    • pp.33-40
    • /
    • 2009
  • The use of the crumb rubber as an asphalt binder modifier may contribute to road maintenance and repair. The adhesion properties of the crumb rubber modified asphalt (CRMA) sealant have attracted interest due to brittle and adhesion failure of asphalt binders at low temperatures. In this study, the influence of a flexibilizer as a modifier for CRMA at low temperatures was investigated. Their properties were measured using the penetration, the softening point, the tensile and tensile adhesion tests at low temperature. The tensile adhesion strength and the strain of CRMAs were increased with increasing ductile deformation of the CR and the asphalt binder in the flexiblizer modified CRMAs. It was found that the flexibilizer concentration was an important factor for tensile and adhesion properties of CRMAs at low temperatures.

  • PDF