• Title/Summary/Keyword: 저영향개발(LID)

Search Result 143, Processing Time 0.026 seconds

Performance evaluation of Surface Temperature Reduction by using Green infrastructure Surface Temperature Measurement for Urban Heat Island Mitigation (도시열섬완화를 위한 그린인프라시설의 표면온도 저감 성능평가)

  • Ko, Jong Hwan;Bae, Woo Bin;Park, Dae Geun;Jung, Won Kyong;Park, Yun mi;Kim, Yong Gil;Kim, Sang Rae
    • Ecology and Resilient Infrastructure
    • /
    • v.5 no.4
    • /
    • pp.257-263
    • /
    • 2018
  • This study is to develop a GSTM (Green infrastructure Surface Temperature Measurment) equipment for reducing the surface temperature of GI by using LID Method. The tests were conducted including GI products such as Greening block, Pervious Block, Soil Block and so on. The GSTM equipment developed by considering the literature surveys are characterized as follows. The non-contact infrared temperature sensor was used to measure the surface temperature, and it was improved to measure the overall average temperature including the center and the corner temperature of the specimen. The developed GSTM equipment was used to compare performance of asphalt and GI products. As a result, the Greening Block show a high difference of $18.4^{\circ}C$ and it contributes to the decrease of surface temperature.

Development of tree box filter LID system for treating road runoff (LID 시설로서 도로에 적용 가능한 수목여과시설 개발)

  • Choi, Jiyeon;Son, Younggyu;Lee, Soyoung;Lee, Yuhwa;Kim, Lee Hyung
    • Journal of Wetlands Research
    • /
    • v.15 no.3
    • /
    • pp.407-412
    • /
    • 2013
  • The aim of this study was to develop a tree box filter system, an example of Low Impact Development technology, for treating stormwater runoff from road. Monitoring of storm events was performed between June 2011 and November 2012 to evaluate the system performance during wet day. Based on the results, all runoff volume generated by rainfall less than 2 mm was stored in the system. The minimum volume reduction of 20% was observed in the system for rainfall greater than 20 mm. The greatest removal efficiency was exhibited by the system for total heavy metals ranging from 70 to 73% while satisfactory removal efficiency was exhibited by the system for particulate matters, organic matters and nutrients ranging from 60 to 68%. The system showed greater pollutant removal efficiency of 67 to 83% for rainfall less than 10 mm compared to rainfall greater than 10 mm which has 39 to 75% pollutant removal efficiency. The system exhibited less pollutant reduction for rainfall greater than 10 mm due to the decreased retention capacity of the system for increased rainfall. Overall, the system has proved to be an option for stormwater management that can be recommended for on-site application. Similar system may be designed based on several factors such as rainfall depth, facility size and pollutant removal efficiency.

Performance Evaluation of Paving Blocks Based Ambient Temperature Reduction Using a Climatic Environment Chamber (기후환경챔버를 활용한 블록의 공기온도 저감 성능평가)

  • Ko, Jong Hwan;Park, Dae Geun;Kim, Yong Gil;Kim, Sang Rae
    • Ecology and Resilient Infrastructure
    • /
    • v.4 no.4
    • /
    • pp.187-192
    • /
    • 2017
  • This study evaluated the reduction performance of ambient temperature and the amount of evaporation that takes place depends on the temperature difference of paving blocks which are used in the sidewalk, roadway, parking lot, park, plaza, and etc. The water-retentive block of the LID (Low Impact Development) practice was compared with the conventional concrete block. For the quantitative performance evaluation, experiments were performed in a climatic environment chamber capable of controlling the climatic environment (solar radiation, temperature, humidity, rainfall, and snowfall). The method for performance evaluation was proposed using temperature, humidity, and ambient air of paving blocks which changes according to the solar radiation and the wind speed after the rainfall. As a result, the evaporation amount of the water-retentive block was 2.6 times higher than that of the concrete block, the surface temperature of water-retentive block was $10^{\circ}C$ lower than the concrete block, and the air temperature of water-retentive block was $4.6^{\circ}C$ lower than the concrete block. Therefore, it is analyzed that the water-retentive block with a large amount of evaporation is more effective in reducing the urban heat island phenomenon as compared with the concrete block.

A study on the number of days without precipitation in the rainfall simulation test for estimating the CN of the permeable pavement (투수포장체 CN 산정을 위한 강우모사 시험의 선행 무강우일수 방안 연구)

  • Park Byeong-Woo;Kang Du-Kee;Park Jae-Rock
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.353-353
    • /
    • 2023
  • 기후변화에 대응하는 도시유출 저감과 열섬효과를 방지하기 위해 투수블럭 시공이 증가 추세 있으나, 투수블럭과 하부 도로포장체에 대한 강우모사 시험시 토양함수율 설정기준을 정립할 필요가 있다. 유역 혹은 시험체의 유출량 예측에는 토지 이용에 따라 미국자연자원보호청(Natural Resources Conservation Service, NRCS)의 SCS 유효우량 산정 방법을 통해 CN을 활용할 수 있으며, 이때 유역 혹은 시험체의 선행강우일수에 따라 유출량 결과가 큰 차이가 발생한다. 연구를 위해 시험실이 위치하고 있는 부산시와 양산시 무강우 일수(10년, 2012~2021)를 홍수기, 비홍수기 각각 분석한 결과에 따라, 투수블록 포장체의 CN 산정을 위해 자연강우 이후 시험시 AMC조건을 따르며, 무강우일수 5일 이내에는 비성수기 12.7~27.94mm, 성수기 35.56~53.34mm의 평균강우 20.32mm, 44.45mm에 해당하는 체적의 실험수를 사전에 살수한 후 강우모의시험을 진행한다. 사전살수를 통해 하부기층 토양을 AMC-II 기준에 맞추고, 강우모의 시험을 통해 CN(II) 산정한다. 동일기준에서 진행된 시험 결과, 일정한 유출을 확인하였으며, 적용에 일관성을 유지할 수 있었다. 따라서 토양종류와 토양함수조건에 의거 투수블록 포장 시험체의 CN을 산정을 통해, 도시홍수 유출모형에 적용할 수 있다. 53.34mm 이상의 자연강우시 모니터링을 통한 CN(III)을 산정하여CN(II)로 환산하여 경제적이고 합리적인 유출량을 산정한다.

  • PDF

A Case Study on the Application of Green Stormwater Infrastructure (GSI) in Public building-types (공공청사형 그린빗물인프라(GSI) 시범 적용 사례 연구)

  • Hyo Jung Lee;Hyun Suk Shin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.364-364
    • /
    • 2023
  • 최근 환경부에서 발표한 「제3차(2021~2025) 강우유출 비점오염관리 종합대책(2020)」에 의하면, 우리나라는 지난 50년간 급격한 도시화, 산업화 과정을 거치면서 불투수면적이 전 국토의 약 22.4%에 달한다고 보고되고 있다. 특히 전체 소권역의 6%에 해당하는 51개 소권역의 경우 불투수 면적률 25%를 넘어서고 있는 것으로 조사되었다. 이러한 불투수면의 증가는 기후변화에 의한 영향으로 토양 침투량과 기저유출량을 감소, 갈수기 하천건천화 심화, 우기 표면유출수 증가를 가중시키며 이로인한 비점오염물질 유입 증가, 수질 악화의 원인으로 작용 될 수 있다. 이에 정부에서는 저영향개발(Low Impact Development, LID) 사업 및 친환경그린인프라(Green Infrastructure, GI) 기술요소를 적용하여 도시지역 기후위기 대응 수단의 일원으로 우수유출 저감, 물순환 구조 개선, 비점오염원을 관리하고자 '그린빗물인프라(Green Stormwater Infrastructure, GSI) 조성 사업'을 추진하여 공공청사를 중심으로 학교, 도서관, 체육시설, 공원 등 적용 범위를 확대하고 있다. 이에 본 연구에서는 기후변화에 가장 취약한 해안도시지역인 경상남도에 위치하고 있으며, 불투수면적이 높고 노후화된 소규모 청사 2곳을 시범 구역으로 선정하였다. 각 시범 구역별 GSI 시설 적용이 가능한 주차장, 화단, 옥상 등의 개선방안을 제시하였으며, 적용 규모를 달리하여 물순환·물 환경 개선 효과를 검증하였다. 검증에는 국내에서 개발된 K-LIDM 모형을 활용한 우수유출저감 및 직접유출체적 산정결과를 통해 물순환 효과를, 국립환경과학원에서 제시되고 있는 '토지계 지목별 발생부하원단위', 수질환경개선 보고서에서 제시된 침투형, 식생형 비점오염저감시설의 저감효율을 활용하여 물순환 저감효과를 분석하여 비교하였다.

  • PDF

A study on the rainfall management target considering inter-event time definition (IETD) (무강우 지속시간(IETD)을 고려한 빗물관리 목표량 설정 방안 연구)

  • Baek, Jongseok;Kim, Jaemoon;Park, Jaerock;Lim, Kyoungmo;Shin, Hyunsuk
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.8
    • /
    • pp.603-611
    • /
    • 2022
  • In urban areas, the impermeable area continues to increase due to urbanization, which interferes with the surface penetrating and infiltrating of rainwater, causing most rainwater runoff to the surface, deepening the distortion of water circulation. Distortion of water circulation affects not only flood disasters caused by rainfall and runoff, but also various aspects such as dry stream phenomenon, deterioration of water quality, and destruction of ecosystem balance, and the Ministry of Environment strongly recommends the use of Low Impact development (LID) techniques. In order to apply the LID technique, it is necessary to set a rainwater management target to handle the increase in outflow after the development of the target site, and the current standard sets the rainwater management target using the 10-year daily rainfall. In this study, the difference from the current standards was analyzed through statistical analysis and classification of independent rainfall ideas using inter-event time definition (IETD) in setting the target amount of rainwater management to improve water circulation. Using 30-year rainfall data from 1991 to 2020, methods such as autocorrelation coefficient (AC) analysis, variation coefficient (VC) analysis, and annual average number of rainfall event (NRE) analysis were applied, and IETD was selected according to the target rainfall period. The more samples the population had, the more IETD tended to increase. In addition, by analyzing the duration and time distribution of independent rainfall according to the IETD, a plan was proposed to calculate the standard design rainfall according to the rainwater management target amount. Therefore, it is expected that it will be possible to set an improved rainwater management target amount if sufficient samples of independent rainfall ideas are used through the selection of IETD as in this study.

Comparison of Flooding Tolerance for the Selection of Plants in Vegetation-Based Low Impact Development Facilities (식생기반형 LID 시설의 식재식물 선정을 위한 내침수성 비교)

  • Lee, Eun-Yeob;Hyun, Kyoung-Hak;Hou, Jin-Sung;Park, Mi-Ok;Koo, Bon-Hak
    • Journal of Environmental Impact Assessment
    • /
    • v.23 no.6
    • /
    • pp.466-476
    • /
    • 2014
  • In this study, 10 species of plants with high adaptability to aquatic environments were compared for selecting plant species suitable for vegetation-based low impact development (LID) facilities. The flooding tolerances of the plants were tested by analyzing their growth status under half-immersion and full-immersion conditions, with varying durations of immersion. In decreasing order of flooding tolerance, the comparative analysis of plant height and leaf width is as follows: Hemerocallis fulva, Juncus effusus var. decipiens, Iris pseudoacorus, Phragmites communis TRIN, Typha orientalis C.Presl, Aster koraiensis Nakai, Iris sanguinea, Equisetum hyemale, Acorus calamus. Specifically, Hemerocallis fulva, Juncus effusus var. decipiens. Iris pseudoacorus showed excellent growth status under both immersion conditions. Iris sanguinea and Equisetum hyemale. withered to death by around day 27 of the experiment, but their flooding tolerance was confirmed to be relatively high. Iris pseudoacoru showed flooding tolerance under the half-immersion condition unlike under the full-immersion condition, when compared on day 21 of the experiment. Aster koraiensis Nakai also thrived better under the half-immersion condition, proving to be a highly immersion-resistant species. On the basis of the results of this experiment, Hemerocallis fulva, Juncus effusus var. decipiens and Iris pseudoacorus, Typha orientalis C.Presl were selected as species suitable for vegetation-based LID facilities.

Evaluation of the Applicability of Stormwater Improvement Model for the Estimation of Wash-off Pollutant in Parking Lot (주차장 지역에서의 유출 및 수질모의를 위한 강우유출수 개선모형 적용성 평가)

  • Jung, Min-Jae;Pak, Gi-Jung;Kim, Hwan-Suk;Kim, Deok-Woo;Yoon, Jae-Young
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05a
    • /
    • pp.440-443
    • /
    • 2012
  • 도시지역의 도로, 교량 및 주차장과 같은 포장지역은 작은 면적이지만 강우 시 다른 토지이용에 비해 강우 유출량이 높고, 상수원인 하천의 종 및 횡방향으로 존재하기 때문에 직접적인 오염 원인으로 작용하고 있다. 이에 대한 대책으로 최적관리기법(Best Management Practices, BMP) 또는 저영향개발(Low Impact Development, LID)과 같은 관리 방안을 적용하여 강우에 의해 발생되는 강우유출수와 비점오염물질을 동시에 저감하는 방안이 연구되고 있으나, 모델링을 통한 비점오염물질 배출량의 정량화와 저감시설의 성능평가에 대한 연구는 부족한 실정이다. 본 연구에서는 주차장 지역에서 발생하는 비점오염물질의 배출량 모의 가능성을 평가하기 위해 국내 외에서 강우유출수의 모의와 저감시설의 성능평가에 많이 사용되고 있는 MUSIC(Model for Urban Stormwater Improvement Conceptualization) 모형과 SWMM(Storm Water Management Model) 모형을 이용하여 강우유출수 수문 수질 모의를 실시하여 각 모형의 적용성을 평가한 결과, 두 모형 모두 총 유출체적 오차가 ${\pm}6%$ 이내로 수문모의에 대한 적용성이 우수하게 나타났지만, 수질의 경우 SWMM 모형이 MUSIC 모형에 비하여 오염물질의 배출량을 실측치와 가깝게 모의함으로서, 결과적으로 대상지역에 대해 SWMM 모형이 MUSIC 모형에 비해 주차장의 초기우수현상을 더 잘 재현하는 것으로 나타났다.

  • PDF

Analysis on the Current Status of Impervious Ratio in Land-use Zone Using Pervious/Impervious Map based on GIS - Focused on Bupyeong-gu Incheon - (GIS기반의 투수/불투수도를 이용한 용도지역별 불투수율 현황분석 - 인천시 부평구를 대상으로 -)

  • Oh, Seong Kwang;Kim, Kye Hyun;Lee, Chol Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.191-191
    • /
    • 2015
  • 무분별한 도시화 및 산업화로 인해 불투수면이 증가하고 있다. 불투수면은 빗물이 투과하지 못하는 지면을 의미한다. 이러한 불투수면은 강우 시 지면에 있는 유해물질이 그대로 인근 수계로 유입되게 함으로써 심각한 수질 오염을 야기한다. 이와 관련하여 환경부에서는 불투수율 관리를 위하여 2013년에 전국토를 대상으로 불투수율을 산정한바 있으나, 소축척 수준의 시 또는 유역 단위 통계만을 산출하였고 대축척 수준의 소규모 개인 필지 내 조경지역 등을 반영한 불투수율 통계는 현재까지 부재하다. 따라서 본 연구에서는 인천시 부평구를 대상으로 소규모 필지까지 적용 가능한 고해상도 투수/불투수도를 제작 및 활용하여 용도지역별 불투수율 현황을 분석하였다. 불투수면의 공간적 분포 확인을 위해 토지피복지도, 수치지형도, 항공사진(25cm급) 등을 활용하여 고해상도 투수/불투수도를 제작하였다. 투수/불투수도는 세분류 토지피복지도 제작 지침인 선형 요소의 경우 폭 3m, 면형 요소의 경우 면적 $10m{\times}10m(100m^2)$를 참조하여 제작되어 개별 필지단위의 불투수면까지 확인 가능하다. 이후 용도지역도를 수집하여 GIS 환경에서 투수/불투수도와 중첩하여 용도지역별 불투수율을 산출하였다. 불투수율을 산정한 결과 부평구 전체 불투수율은 64%로 확인되었다. 또한 용도지역도 중분류상 주거지역의 경우 불투수율이 82.1%, 상업지역의 경우 91.7%, 공업지역의 경우 94.1%, 녹지지역의 경우 30%로 확인되었다. 상업지역 및 공업지역의 경우 불투수율이 90%이상으로 불투수면 관리가 시급하다고 판단되었다. 본 연구 결과는 기존 환경부에서 제작한 투수/불투수도 보다 정확한 불투수면의 공간적 분포 확인 및 불투수 면적 산출이 가능하여 불투수면 우선관리지역 선정을 위한 기초자료로 활용 가능할 것으로 판단된다. 향후 연구에서는 본 연구 결과를 바탕으로 불투수율이 높은 지역을 우선 선별하여 저영향개발(LID, Low Impact Development) 및 그린빗물인프라(GSI, Green Stormwater Infrastructure)의 활용 방안에 관한 연구가 이루어져야한다. 특히, 불투수율이 높은 상업지역 및 공업지역에 대해서는 연구 결과의 적극적인 활용을 통한 개선이 요구된다.

  • PDF

Assessment of the Non-point Source Pollution Control Strategies for Water Quality Improvement in the Haeban Stream of West Nakdong River Watershed (서낙동강 유역 해반천의 수질 개선을 위한 비점오염관리대책 효과 분석)

  • Yejin Kim
    • Journal of Wetlands Research
    • /
    • v.26 no.1
    • /
    • pp.1-9
    • /
    • 2024
  • In this study, a HSPF model was developed to simulate runoff and water quality in the Haebancheon watershed, which has a high land area ratio and population density among the West Nakdong River watersheds. Various non-point source pollution control strategies were applied, and the reduction in pollutant loads and the exceedance rate of water quality standards were analyzed. The scenarios included basic road cleaning for reducing pollutant loads, runoff reduction measures considering extensive low-impact development techniques, and inflow reduction measures to mitigate non-point source pollution entering the river. In the first step, practical conditions such as the number of vehicles for road cleaning in Kimhae City were considered, while for the second and third steps, it was assumed that 50% of the applicable land use area was used to be applicable for the LID techniques. As a result of applying all three measures, it was analyzed that the BOD pollutant load could be reduced by 58.28%, T-N by 58.49%, and T-P by 51.56%. Furthermore, the 60th percentile of water quality measurements accumulated over 5 years was set as the target water quality, and a flow-duration curve was constructed. The exceedance rate of the flow-duration curve before and after applying non-point source pollution reduction measures was analyzed. As a result, for BOD, the exceedance rate decreased from 41.57% before applying the measures to 16.32% after, showing a 25.25% reduction in the exceedance rate. For T-N, the exceedance rate decreased significantly from 40.31% before the measures to 22.84% after, and for T-P, it decreased significantly from 62.43% to 27.22%.