• Title/Summary/Keyword: 저에너지 광자

Search Result 31, Processing Time 0.021 seconds

A Study on the Comparison of HPGe Detector Response Data for Low Energy Photons Using MCNP, EGS, and ITS Codes (MCNP, EGS, ITS코드를 이용한 고순도 게르마늄 검출기의 저에너지 광자에 대한 반응 비교연구)

  • Kim, Soon-Young;Kim, Jong-Kyung;Kim, Jong-Oh;Kim, Bong-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.2
    • /
    • pp.125-129
    • /
    • 1996
  • The energy response of HPGe detector for low energy Photons was determined by using three Monte Carlo codes. MCNP4A. EGS4, and CYLTRAN in ITS3. In this study. bare HPGe detector$(100 mm^2{\times}10mm)$ was used and a pencil beam was incident perpendicularly on the center of the detector surface. The photopeak efficiency, $K_{\alpha}$ and $K_{\beta}$ escape fractions were calculated as a function of incident X-ray energies ranging from 12 to 60 keV in 2-keV increments. Since the Compton. elastic. ana penetration fraction were negligible in this energy range. they were ignored in the calculation. Although MCNP. EGS, and CYLTRAN codes calculated slightly different energy response of HPGe detector for low energy Photons, it appears that the three Monte Carlo codes can Predict the low energy Photon scattering Processes accurately. The MCNP results, which are generally known as to be less accurate at low energy ranges than the EGS and ITS results. are comparable to the results of EGS and ITS and are applicable to the calculation of the low energy response data of a detector.

  • PDF

The Study on Interpretation of the Scatter Degradation Factor using an additional Filter in a Medical Imaging System (의료 영상 시스템에서 부가 필터를 이용한 산란 열화 인자의 해석에 관한 연구)

  • Kang, Sang Sik;Kim, Kyo Tae;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.589-596
    • /
    • 2019
  • X-rays used for diagnosis have a continuous energy distribution. However, photons with low energy not only reduce image contrast, but also contribute to the patient's radiation exposure. Therefore, clinics currently use filters made of aluminum. Such filters are advantageous because they can reduce the exposure of the patient to radiation. However, they may have negative effects on imaging quality, as they lead to increases in the scattered dose. In this study, we investigated the effects of the scattered dose generated by an aluminum filter on medical image quality. We used the relative standard deviation and the scatter degradation factor as evaluation indices, as they can be used to quantitatively express the decrease in the degree of contrast in imaging. We verified that the scattered dose generated by the increase in the thickness of the aluminum filter causes degradation of the quality of medical images.

Dosimetric Properties of LiF:Mg,Cu,Na,Si TL pellets (LiF:Mg,Cu,Na,Si TL 소자의 선량계적 특성)

  • Nam, Young-Mi;Kim, Jang-Lyul;Chang, Si-Young
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.1
    • /
    • pp.7-12
    • /
    • 2001
  • Sintered LiF:Mg,Cu,Na,Si thermoluminescence (TL) pellets were developed for application in radiation dosimetry. In the present study, the TL dosimetric properties of LiF:Mg,Cu,Na,Si TL pellets have been investigated for emission spectrum, dose response, energy response, and fading characteristics. LiF:Mg,Cu,Na,Si TL pellets were made by using a sintering process, that is, pressing and heat treatment from TL powders. Photon irradiations for the experiments were carried out using X-ray beams and a $^{137}Cs$ gamma source at the Korea Atomic Energy Research Institute (KAERI). The average energies and the dose were in the range of 20-662 keV and $10^{-6}-10^{-2}\;Gy$, respectively. The glow curves were measured with a manual type TLD reader(System 310, Teledyne) at a constant nitrogen flux and a linear heating rate. For a constant heating rate of $5^{\circ}C\;s^{-1}$, the main dosimetric peak of glow curve appeared at $234^{\circ}C$, the activation energy was 2.34 eV and frequency factor was $1.00{\times}10^{23}$. TL emission spectrum is appeared at the blue region centered at 410 nm. A linearity of photon dose response was maintained up to 100 Gy. The photon energy responses relative to $^{137}Cs$ response were within ${\pm}20%$ at overall photon energy region. The fading of TL sensitivity of the pellets stored at the room temperature was not found for one year.

  • PDF

Structure and Photoluminescence of ZnS-ZnSe Superlattices grown by Hot Wall Epitaxy (Hot Wall Epitaxy에 의하여 성장된 ZnS-ZnSe 초격자의 구조 및 Photoluminescence)

  • ;S. Sakakibara;K. Ishino;A. Ishida;H. Fujiyasu
    • Journal of the Korean Vacuum Society
    • /
    • v.3 no.2
    • /
    • pp.212-219
    • /
    • 1994
  • Hot wall epitaxy법에 의하여 GaAs(100)aus 위에 ZnS-ZnSe 초격자를 성장하였다. ZnS-ZnSe 초격자의 주기는 x-선 회절 패턴에 의하여 확인되었고 이것은 변형을 고려하고 계산된 이론적인 패턴과 비교되었다. 경계면에 평행한 ZnS와 ZnSe의 변형의 비는 ZnSe에 대하여 ZnS의 두께기 증가할수록 감 소되었다. ZnS-ZnSe 초격자의 photoluminescence(PL)는 고에너지 영역의 예리한 스펙트럼과 저에너지 영역의 폭이 넓은 스펙트럼으로 구성되어있다. PL의 광자에너지는 Kronig-Penney 모델을 사용하여 계 산된 이론적인 에너지 값과 비교한 결과 type I의 초격자임을 알았다.

  • PDF

A Study on the Dose Assessment Methodology Using the Probabilistic Characteristics of TL Element Response (확률분포 특성을 이용한 열형광선량계의 선량평가방법에 관한 연구)

  • Cho, Dae-Hyung;Oh, Jang-Jin;Han, Seung-Jae;Na, Seong-Ho;Hwang, Won-Guk;Lee, Won-Keun
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.3
    • /
    • pp.123-138
    • /
    • 1998
  • Characteristics of element responses of Panasonic UD802 personnel dosimeters in the X, ${\beta}$, ${\gamma}$, ${\gamma}/X$, ${\gamma}/{\beta}$ and ${\gamma}$/neutron mixed fields were assessed. A dose-response algorithm has been developed to decide the high probability of a radiation type and energy by using the distribution in all six ratios of the multi-element TLD. To calculate the 4-element response factors and ratios between the elements of the Panasonic TLDs in the X, $\beta$, and $\gamma$ radiation fields, Panasonic’s UD802 TLDs were irradiated with KINS’s reference irradiation facility. In the photon radiation field, this study confirms that element-3 (E3) and element-4 (E4) of the Panasonic TLDs show energy dependent both in low- and intermediate-energy range, while element-1 (E1) and element-2 (E2) show little energy dependency in the entire whole range. The algorithm, which was developed in this study, was applied to the Panasonic personnel dosimetry system with UD716AGL reader and UD802 TLDs. Performance tests of the algorithm developed was conducted according to the standards and criteria recommended in the ANSI N13.11. The sum of biases and standard deviations was less than 0.232. The values of biases and standard deviations are distributed within a triangle of a lateral value of 0.3 in the ordinate and abscissa, With the above algorithm, Panasonic TLDs satisfactorily perform optimum dose assessment even under an abnormal response of the TLD elements to the energy imparted. This algorithm can be applied to a more rigorous dose assessment by distinguishing an unexpected dose from the planned dose for the most practical purposes, and is useful in conducting an effective personnel dose control program.

  • PDF

The Effect of Partially Used High Energy Photon on Intensity-modulated Radiation Therapy Plan for Head and Neck Cancer (두경부암 세기변조방사선치료 계획 시 부분적 고에너지 광자선 사용에 따른 치료계획 평가)

  • Chang, Nam Joon;Seok, Jin Yong;Won, Hui Su;Hong, Joo Wan;Choi, Ji Hun;Park, Jin Hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • Purpose: A selection of proper energy in treatment planning is very important because of having different dose distribution in body as photon energy. In generally, the low energy photon has been used in intensity-modulated radiation therapy (IMRT) for head and neck (H&N) cancer. The aim of this study was to evaluate the effect of partially used high energy photon at posterior oblique fields on IMRT plan for H&N cancer. Materials and Methods: The study was carried out on 10 patients (nasopharyngeal cancer 5, tonsilar cancer 5) treated with IMRT in Seoul National University Bundang Hospital. CT images were acquired 3 mm of thickness in the same condition and the treatment plan was performed by Eclipse (Ver.7.1, Varian, Palo Alto, USA). Two plans were generated under same planing objectives, dose volume constraints, and eight fields setting: (1) The low energy plan (LEP) created using 6 MV beam alone, (2) the partially used high energy plan (PHEP) created partially using 15 MV beam at two posterior oblique fields with deeper penetration depths, while 6 MV beam was used at the rest of fields. The plans for LEP and PHEP were compared in terms of coverage, conformity index (CI) and homogeneity index (HI) for planning target volume (PTV). For organs at risk (OARs), $D_{mean}$ and $D_{50%}$ were analyzed on both parotid glands and $D_{max}$, $D_{1%}$ for spinal cord were analyzed. Integral dose (ID) and total monitor unit (MU) were compared as addition parameters. For the comparing dose to normal tissue of posterior neck, the posterior-normal tissue volume (P-NTV) was set on the patients respectively. The $D_{mean}$, $V_{20Gy}$ and $V_{25Gy}$ for P-NTV were evaluated by using dose volume histogram (DVH). Results: The dose distributions were similar with regard to coverage, CI and HI for PTV between the LEP and PHEP. No evident difference was observed in the spinal cord. However, the $D_{mean}$, $D_{50%}$ for both parotid gland were slightly reduced by 0.6%, 0.7% in PHEP. The ID was reduced by 1.1% in PHEP, and total MU for PHEP was 1.8% lower than that for LEP. In the P-NTV, the $D_{mean}$, $V_{20Gy}$ and $V_{25Gy}$ of the PHEP were 1.6%, 1.8% and 2.9% lower than those of LEP. Conclusion: Dose to some OARs and a normal tissue, total monitor unit were reduced in IMRT plan with partially used high energy photon. Although these reduction are unclear how have a clinical benefit to patient, application of the partially used high energy photon could improve the overall plan quality of IMRT for head and neck cancer.

  • PDF

Preparation of an Inorganic Scintillator Loaded Film for the Measurement of Surface Contamination and its Performance Test (표면오염 측정용 무기섬광 함침 필름의 제조 및 성능 평가)

  • 서범경;이근우;임난주;박진호;한명진
    • Journal of Energy Engineering
    • /
    • v.13 no.2
    • /
    • pp.93-100
    • /
    • 2004
  • The smear media possible to sampling and radiation detection was prepared and evaluated for the surface contamination using indirect method. The films were made by impregnating Cerium Activated Yttrium Silicate (CAYS) in a polysulfone membrane. The membranes used solution as a dimethylformamide (DMF) and methylene chloride (MC), polysulfone as a polymer matrix and CAYS as a inorganic scintillator. The proximity membranes were prepared with single- and double-layered structure. The solidified methods were immersion to the nonsolvent bath such at water and ethanol and solvent evaporation. The measurement of the photon produced by interaction with radiation and inorganic scintillator used a photomultiflier tube (PMT), amplifier, and counter. In the comparison with the low background alpha/beta counter, the counter rate using inorganic scintillator proximity membrane for the $\^$14/C surface contamination was about 50%. Also. the $^3$H counting results revealed that the prepared membranes were efficient to monitor the surface contaminated with the low energy be-ray emitter nuclides.

Measuring Absorbed Dose from Medical X-ray Equipment Using Optically Stimulated Luminescence Dots (광자극선량계의 저에너지 엑스선 특성비교)

  • Jung, Sook Jin;Jin, Gye Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.79-83
    • /
    • 2018
  • In this paper, we measured and analyzed the dose correction factor, absorbed dose linearity, peak voltage X-ray response, angular dependence. Exposure dose correction factor, absorbed dose linearity, and peak voltage linearity using the medical X-ray generator were all in accordance with IEC-62387-1 (2007). The reference to the dosimetry direction at 0, 30, and 60 degrees relative to baseline radiation exposure was -29% (${\pm}30^{\circ}$) and + 67% (${\pm}60^{\circ}$). The values measured at $30^{\circ}$ were -8% lower than the standard and -18% lower than the standard at $60^{\circ}$. Therefore, the effect of direction should be corrected when using OSL dot dosimeter.

Assessment of the usefulness of the Machine Performance Check system that is an evaluation tools for the determination of daily beam output (일간 빔 출력 확인을 위한 평가도구인 Machine Performance Check의 유용성 평가)

  • Lee, Sang Hyeon;Ahn, Woo Sang;Lee, Woo Seok;Choi, Jin Hyeok;Kim, Seon Yeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.65-73
    • /
    • 2017
  • Purpose: Machine Performance Check (MPC) is a self-checking software based on the Electronic Portal Imaging Device (EPID) to measure daily beam outputs without external installation. The purpose of this study is to verify the usefulness of MPC by comparing and correlating daily beam output of QA Beamchecker PLUS. Materials and Methods: Linear accelerator (Truebeam 2.5) was used to measure 10 energies which are composed of photon beams(6, 10, 15 MV and 6, 10 MV-FFF) and electron beams(6, 9, 12, 16 and 20 MeV). A total of 80 cycles of data was obtained by measuring beam output measurement before treatment over five months period. The Pearson correlation coefficient was used to evaluate the consistency of the beam output between the MPC and the QA Beamchecker PLUS. In this study, if the Pearson correlation coefficient is; (1) 0.8 or higher, the correlation is very strong (2) between 0.6 and 0.79, the correlation is strong (3) between 0.4 and 0.59, the correlation is moderate (4) between 0.2 and 0.39, the correlation is weak (5) lower than 0.2, the correlation is very weak. Results: Output variations observed between MPC and QA Beamchecker PLUS were within 2 % for photons and electrons. The beam outputs variations of MPC were $0.29{\pm}0.26%$ and $0.30{\pm}0.26%$ for photon and electron beams, respectively. QA Beamchecker PLUS beam outputs were $0.31{\pm}0.24%$ and $0.33{\pm}0.24%$ for photon and electron beams, respectively. The Pearson correlation coefficient between MPC and QA Beamchecker PLUS indicated that photon beams were very strong at 15 MV, and strong at 6 MV, 10 MV, 6 MV-FFF and 10 MV-FFF. For electron beams, the Pearson correlation coefficient were strong at 16 MeV and 20 MeV, moderate at 9 MeV and 12 MeV, and very weak at 6 MeV. Conclusion: MPC showed significantly strong correlation with QA Beamchecker PLUS when testing with photon beams and high-energy electron beams in the evaluation of daily beam output, but the correlation when testing with low-energy electron beams (6 MeV) appeared to be low. However, MPC and QA Beamchecker PLUS are considered to be suitable for checking daily beam output, as they performed within 2 % of beam output consistency during the observation. MPC which can perform faster than the conventional daily beam output measurement tool, is considered to be an effective method for users.

  • PDF

Sensitivity Variations with pre-irradiation dose to P-type Semi conductor for radiation dosimetry

  • 최태진;김옥배
    • Progress in Medical Physics
    • /
    • v.6 no.1
    • /
    • pp.49-57
    • /
    • 1995
  • The semiconductor detector has a high sensitive to radiation and a small volume. It has been frequently used in high energy photon and electron beamdosimetry. However, Semiconductor detector are subject to radiation damage in high energy radiation beam which reduces the sensitivity and creat a large discrepancy. In this experiments, P-type semiconductor was irradiated to 18 MeV electron beam with pre-irradiation for reducing the sensitivity for high reproducibility and investigated the dose characteristics against the dose rate variations. The sensitivity per unit dose in small dose rate showed a 35% large different to a large dose rate with pre-irradiation dose for 0.5 KGy and 20% for 3 KGyin this study. The silicon detector has showed a large dependency of beam direction with 13% discrepancy and a linear sensitive as increased temperature.

  • PDF