• Title/Summary/Keyword: 저산소혈증

Search Result 18, Processing Time 0.032 seconds

The Continuous Monitoring of Oxygen Saturation During Fiberoptic Bronchoscopy (기관지내시경 검사시 지속적인 동맥혈 산소포화도 감시의 필요성)

  • Kang, Hyun Jae;Kim, Yeon Jae;Chyun, Jae Hyun;Do, Yun Kyung;Lee, Byung Ki;Kim, Won Ho;Park, Jae Yong;Jung, Tae Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.4
    • /
    • pp.385-394
    • /
    • 2002
  • Background : Flexible fiberoptic bronchoscopy(FFB) has become a widely performed technique for diagnosing and managing pulmonary disease because of its low complication and mortality rate. Since the use of FFB can in patients with severely depressed cardiorespiratory function is increasing and hypoxemia during the FFB can induce significant cardiac arrhythmias, the early detection and adequate management of hypoxemia during FFB is clinically important. Method : To evaluate the necessity of the continuous monitoring of the oxygen saturation($SaO_2$) during the FFB, the $SaO_2$ was continuously monitored from the finger tip using pulse oximetry before, during and after the FFB in 379 patient. The patients were then divided into two groups, those with and without hypoxemia($SaO_2$<90%). The baseline pulmonary function data and the clinical characteristics of the two groups were compared. Results : The mean baseline $SaO_2$ was $96.9{\pm}2.85%$. An $SaO_2$ <90% was recorded at some point in 62(16.4%) out of 379 patients, with 12 out of 62 experiencing this prior to the FFB, in 37 out of 62 during the FFB, and in 13 out of 62 after the FFB. No differences were observed in the smoking and sex distribution between those with and without hypoxemia. The mean age was older in those with hypoxemia than in those without. Significant differences were observed in the mean baseline $SaO_2$ and the mean time for the procedure between the two groups. The $FEV_1$ was significantly lower in those with hypoxemia, and both the FVC and $FEV_1/FVC$ also tended to decrease in this group. Managing hypoxemia included deep breathing in 20 patients, a supplemental oxygen supply in 39 patients, and the abortion of the procedure in 3 patients. Conclusion : These results suggest that the continuous monitoring of the oxygen saturation is necessary during fiberoptic bronchoscopy, and it should be performed in patients with a depressed pulmonay function in order for the early detection and adequate management of hypoxemia.

Effects of Open or Closed Suctioning on Lung Dynamics and Hypoxemia in Mechanically Ventilated Patients (기관 내 흡인 유형이 인공호흡기 대상자의 폐기능과 저산소혈증에 미치는 효과)

  • Lee, Eun Young;Kim, Su Hyun
    • Journal of Korean Academy of Nursing
    • /
    • v.44 no.2
    • /
    • pp.149-158
    • /
    • 2014
  • Purpose: This study was conducted to compare effects of open and closed suctioning methods on lung dynamics (dynamic compliance, tidal volume, and airway resistance) and hypoxemia (oxygen saturation and heart rate) in mechanically ventilated patients. Methods: This study was a cross-over repeated design. Participants were 21 adult patients being treated with endotracheal intubation using a pressure-controlled ventilator below Fraction of Inspired Oxygen ($FiO_2$) 60% and PEEP $8cmH_2O$. Data were collected at baseline and 1, 2, 3, 4, 5, and 10 minutes after suctioning. Data were analyzed using two-factor ANOVA with repeated measures on time and suctioning type. Results: Effects of the interaction between suction type and time were significant for oxygen saturation and heart rate but not significant for dynamic compliance, tidal volume, or airway resistance. Prior to performance of suctioning, tidal volume and oxygen saturation were significantly lower, but airway pressure and heart rate were significantly higher using the closed suctioning method as compared with the open suctioning method. Conclusion: For patients on ventilator therapy below $FiO_2$ 60% and PEEP $8cmH_2O$, open suctioning performed after delivery of 100% $FiO_2$ using a mechanical ventilator may not have as much negative impact on lung dynamics and hypoxemia as closed suctioning.

Prediction of Intubation after Bronchoscopy with Non-invasive Positive Pressure Ventilation Support in Patients with Acute Hypoxemic Respiratory Failure (급성 저산소혈증 환자에서 비침습적 양압환기 적용 하 기관지경 검사 후 기관 삽관의 예측 인자)

  • Song, Jae-Uk;Kim, Su-A;Choi, E Ryoung;Kim, Soo Min;Choi, Hee Jung;Lim, So Yeon;Park, So Young;Suh, Gee Young;Jeon, Kyeongman
    • Tuberculosis and Respiratory Diseases
    • /
    • v.67 no.1
    • /
    • pp.21-26
    • /
    • 2009
  • Background: Non-invasive positive pressure ventilation (NPPV) ensures adequate gas exchange during bronchoscopy in spontaneously breathing, hypoxemic patients, thus avoiding endotracheal intubation. However, in some patients, endotracheal intubation is eventually required after bronchoscopy. This study investigated the incidence of intubation and predictors of a need for emergency intubation prior to NPPV bronchoscopy initiation. Methods: On a retrospective basis, we reviewed the medical records of 36 patients (median age, 55 years; interquartile range [IQR], 43~65 years) with acute hypoxemic respiratory failure who required NPPV during bronchoscopy between January 2005 and October 2007. Results: All patients were hypoxemic (median $PaO_2/FiO_2$ ratio 155; IQR 90~190), but tolerated bronchoscopy with NPPV support. SOFA score and SAPS II score immediately before NPPV initiation were 4 (3~7) and 36 (30~42), respectively. Seventeen (47%) patients needed endotracheal intubation at a median time of 22 (2~50) hours after bronchoscopy. Patients who needed intubation after bronchoscopy had a higher in-hospital mortality (11 [65%] vs. 4 [21%], p=0.017). Upon multiple logistic regression analysis, the need for intubation after bronchoscopy was independently associated with a $P_aO_2/FiO_2$ ratio (OR, 0.961; 95% CI, 0.924~0.999; p=0.047) immediately before NPPV initiation for bronchoscopy. Conclusion: The severity of the hypoxemia immediately prior to NPPV initiation for bronchoscopy was associated with the need for intubation after bronchoscopy in patients with hypoxemic respiratory failure.

Continuous Positive Airway Pressure during Bronchoalveolar Lavage in Patients with Severe Hypoxemia (심한 저산소혈증 환자에서 기관지폐포세척술 시 안면마스크를 이용한 지속성 기도양압의 유용성)

  • An, Chang Hyeok;Lim, Sung Yong;Suh, Gee Young;Park, Gye Young;Park, Jung Woong;Jeong, Seong Hwan;Lim, Si Young;Oui, Misook;Koh, Won-Jung;Chung, Man Pyo;Kim, Hojoong;Kwon, O Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.54 no.1
    • /
    • pp.71-79
    • /
    • 2003
  • Background : A bronchoalveolar lavage(BAL) is useful in diagnosing the etiology of bilateral pulmonary infiltrations, but may worsen the oxygenation and clinical status in severely hypoxemic patients. This study assessed the safety and efficacy of the continuous positive airway pressure(CPAP) using a conventional mechanical ventilator via a face mask as a tool for maintaining the oxygenation level during BAL. Methods : Seven consecutive patients with the bilateral pulmonary infiltrates and severe hypoxemia ($PaO_2/FIO_2$ ratio ${\leq}200$ on oxygen 10 L/min via mask with reservoir bag) were enrolled. The CPAP 5-6 $cmH_2O(F_IO_2\;1.0)$ was delivered through an inflatable face mask using a conventional mechanical ventilator. The CPAP began 10 min before starting the BAL and continued for 30 min after the procedure was completed. A bronchoscope was passed through a T-adapter and advanced through the mouth. BAL was performed using the conventional method. The vital signs, pulse oxymetry values, and arterial blood gases were monitored during the study. Results : (1) Median age was 56 years(male:female=4:3). (2) The baseline $PaO_2$ was $78{\pm}16mmHg$, which increased significantly to $269{\pm}116mmHg$(p=0.018) with CPAP. After the BAL, the $PaO_2$ did not decrease significantly but returned to the baseline level after the CPAP was discontinued. The $SpO_2$ showed a similar trend with the $PaO_2$ and did not decrease to below 90 % during the duration of the study. (3) The $PaCO_2$ increased and the pH decreased significantly after the BAL but returned to the baseline level within 30 min after the BAL. (5) No complications directly related to the BAL procedure were encountered. However, intubation was necessary in 3 patients(43 %) due to the progression of the underlying diseases. Conclusion : In severe hypoxemic patients, CPAP using a face mask and conventional mechanical ventilator during a BAL might allow minimal alterations in oxygenation and prevent subsequent respiratory failure.

A Case of Rapidly Developed Obesity Hypoventilation Syndrome in a Patient with Kyphoscoliosis (척추후측만증 환자에서 급속히 진행된 비만성 저환기 증후군 1례)

  • Kim, Min Young;Jeong, Jee Sun;Jang, Yu Na;Go, Se-eun;Lee, Sang Haak;Moon, Hwa Sik;Kang, Hyeon Hui
    • Sleep Medicine and Psychophysiology
    • /
    • v.22 no.1
    • /
    • pp.30-34
    • /
    • 2015
  • Obesity hypoventilation syndrome (OHS) is characterized by severe obesity, excessive daytime sleepiness, hypoxemia and hypercapnea. Because OHS mimics pulmonary hypertension or cor pulmonale, clinicians should recognize and treat this syndrome appropriately. A 58-year-old female visited the emergency room because of dyspnea. She was obese and had kyphoscoliosis. The patient also experienced snoring, recurrent choking during sleep and daytime hypersomnolence which worsened after gaining weight in the recent year. The arterial blood gas analysis showed she experienced hypoxemia and hypercapnea not only during nighttime but also daytime. We suspected OHS and the patient underwent polysomnography to confirm whether obstructive sleep apnea was present. During the polysomnography test, sleep obstructive apnea was observed and apnea-hypopnea index was 9.2/hr. The patient was treated with bilevel positive airway pressure therapy (BiPAP). After BiPAP for 4 days, hypoxemia and hypercapnia were resolved and she is currently well without BiPAP. We report a case successfully treated with clinical improvement by presuming OHS early in a patient who had typical OHS symptoms, even while having other conditions which could cause hypoventilation.

Changes of Blood Gases, Plasma Catecholamine Concentrations and Hemodynamic Data in Anesthetized Dogs during Graded Hypoxia Induced by Nitrous Oxide (아산화질소에 의한 점진적 저산소가스 흡입이 혈중 가스치와 Catecholamine치 및 혈역학에 미치는 영향)

  • Kim, Sae-Yeon;Song, Sun-Ok;Bae, Jung-In;Cheun, Jae-Kyu;Bae, Jae-Hoon
    • Journal of Yeungnam Medical Science
    • /
    • v.15 no.1
    • /
    • pp.97-113
    • /
    • 1998
  • The sympathoadrenal system plays an important role in homeostasis in widely varing external environments. Conflicting findings, however, have been reported on its response to hypoxia. We investigated the effect of hypoxia on the sympathoadrenal system in dogs under halothane anesthesia by measuring levels of circulating catecholamines in response to graded hypoxia. Ten healthy mongreal dogs were mechanically ventilated with different hypoxic gas mixtures. Graded hypoxia and reoxygenation were induced by progressively decreasing the oxygen fraction in the inhalation gas mixture from 21%(control) to 15%, 10% and 5% at every 5 minutes, and then reoxygenated with 60% oxygen. Mean arterial pressure, central venous pressure and mean pulmonary arterial pressure were measured directly using pressure transducers. Cardiac output was measured by the thermodilutional method. For analysis of blood gas, saturation and content, arterial and mixed venous blood were sampled via the femoral and pulmonary artery at the end of each hypoxic condition. The concentration of plasma catecholamines was determined by radioenzymatic assay. According to the exposure of graded hypoxia, not only did arterial and mixed venous oxygen tension decreased markedly at 10% and 5% oxygen, but also arterial and mixed venous oxygen saturation decreased significantly. An increased trend of the oxygen extraction ratio was seen during graded hypoxia. Cardiac output, mean arterial pressure and systemic vascular resistance were unchanged or increased slightly. Pulmonary arterial pressure(PAP) and pulmonary vascular resistance(PVR) were increased by 55%, 76% in 10% oxygen and by 82%, 95% in 5% oxygen, respectively(p<0.01). The concentrations of plasma norepinephrine, epinephrine and dopamine increased by 75%, 29%, 24% in 15% oxygen and by 382%, 350%, 49% in 5% oxygen. These data suggest that the sympathetic nervous system was activated to maintain homeostasis by modifying blood flow distribution to improve oxygen delivery to tissues by hypoxia, but hemodynamic changes might be blunted by high concentration of nitrous oxide except PAP and PVR. It would be suggested that hemodynamic changes might not be sensitive index during hypoxia induced by high concentration of nitrous oxide exposure.

  • PDF

Clincal Manifestations of Patients Dying of Severe Community Acquired Pneumonia (중증 원외폐렴으로 사망한 환자의 임상적 분석)

  • Choi, Won-Il;Sohn, Jeong-Ho;Kwun, Oh-Yong;Heo, Jeong-Sook;Whang, Jae-Seok;Han, Seong-Beom;Jeon, Young-June
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.5
    • /
    • pp.537-545
    • /
    • 1994
  • Background: In 1987, the British Thoracic Society (BTS) subjected an extensive list of patient variables to statistical analysis in a prospective study of prognosis in 453 adults with community-acquired pneumonia and, subsequently published guidelines for management of severe community acquired pneumonia. It was hoped that those at risk of dying from community acquired pneumonia could be easily identified and treated appropriately, thereby reducing mortality. To date, severe community acquired pneumonia has not been well studied in Korea. Therefore, we studied retrospectively 10 patients dying of severe community acquired pneumonia in Dongsan Hospital to see clinical manifestations of dying of severe community-acquired pneumonia. Methods: Between July 1987 and july 1993, 498 patients were admitted to Keimyung University Dongsan Hospital with community acquired pneumonia, and 77 of them received intensive care. Of the 77 patients, 10 patients died. We reviewed medical records of these patients. Results: 1) The mean age of the patients was 56.2 years(range, 25 to 75 years). There were 7 men and 3 women. Seven patients(70%) were older than 60years of age. 2) The clinical features on admission were as follows: tachypnca, hypoxemia, mental change, cyanosis, leukopenia, leukocytosis, azotemia, hypotension, hypoalbuminemia in order of frequency. Three patients had one abnormal physical finding, 3 patients had 2, 2 patients had 3, and 2 patients had none of these abnormal physical findings. All patients had at least one of the abnormal laboratory findings. 3) A potential bacterial pathogen was isolated in sputum culture from 2 patients. One was E.coli, the other Enterobacter species. Sputum stain were positive in eight cases (G(+)cocci in six, G(+) cocci and G(-)bacilli in two). 4) Features of respiratory failure were the main reasons for ICU transfer, but two patients were transferred only following a cardiac or respiratory arrest in the general ward. 5) The mean of 2.7 different antibiotics were given to the patients. The aminoglycoside and first generation cephalosporin were the most frequently prescribed antibiotics, followed by the third generation cephalosporin and vancomycin. The most frequently prescribed antibiotics combination was a 1st generation cephalosporin plus an aminoglycoside. 6) Seven patients death(70%) occured after admission within the first five days, and a mean duration of hospitaliztion was 11.2 days. Conclusion: As the results show most death occured within the first five days after admission and aged patients; consequently, an aggressive intensive treatment should be provided early to the patients with severe community acquired pneumonia, and we should pay more attention to the aged patients.

  • PDF

The Relationship between Psychopathology and Hypoxemia in Hospitalized Pneumoconiosis Patients (진폐증 입원환자에서 저산소혈증과 정신병리의 연관성)

  • Park, Sae-Han;Ahn, Joung-Sook;Choi, Young-Hoon;Jin, Sae-Young;Park, Ki-Chang
    • Anxiety and mood
    • /
    • v.2 no.2
    • /
    • pp.122-127
    • /
    • 2006
  • Objective : We examined the putative association between the psychological symptoms and hypoxemia in hospitalized pneumoconiosis patients. Methods : One hundred and nine hospitalized pneumoconiosis patients were divided into two groups according to their level of hypoxemia (PaO2); hypoxemic group consisted of 47 patients with PaO2 lower than 80 mmHg, and comparative group consisted of 62 patients with higher than 80 mmHg. All of them were interviewed with the Hamilton Depression Rating Scale (HAM-D), and completed the Symptom Checklist-90items-Revised (SCL-90-R) and the State-Trait Anxiety Inventory (STAI). The medical data (PaO2, PaCO2, Hb, and Hct), number of hospital days and socio-demographic data as well as scores of the three psychological measurements were compared between the two groups. Results : Hypoxemic patients with lower PaO2 showed higher scores in the HAM-D (p=0.01) and stateanxiety subscale of the STAI (p<0.05). Values of hemoglobin and hematocrit were negatively correlated with levels of trait-anxiety (p<0.05). Thirty patients (27.5%) of total subjects suffered from depression (higher than 18 in the HAM-D), and 46.8% of hypoxemic patients were depressed, whereas 12.9% of comparative group patients were depressed (p=0.01). Conclusion : These results suggest that depression and anxiety might be associated with the hypoxemic mechanism in pneumoconiosis patients.

  • PDF

Experimental Study of the Influence of the Upper Airway Obstruction on the Blood Gas Analysis (인위적인 기도협착이 동맥혈액가스에 미치는 영향)

  • 정해영;김중환;조영상
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1979.05a
    • /
    • pp.8.2-8
    • /
    • 1979
  • Acute obstruction of the upper airway from trachea, a foreign body or Iaryngospasm may lead to death in a few minutes. The immediate restoration of an adequate airway in these patients may be lifesaving. Spontaneous respiration by means of a needle inserted into the trachea was studied in 21 rabbits using 16, 18, and 20 gauge extrcatheters. The results are as follows; 1) Airway resistance was markedly increased in all experimental animals. consequently tidal volume was also significantly decreased, but this seems to be compensatory by increased of respiratory frequency in l6G group. 2) Blood gas analysis revealed adequate pulmonary ventilation through the constricted airway (about 1/3 of normal sized trachea) during 60 minutes. In the other hand, hypercarbia, hypoxemia, and metabolic acidosis were developed in the group with severe constriction of the upper airway (about 1/4-1/6 of normal sized trachea). 3) The further study is postulated to confirm the the possibility of application of needle trcheostomy in man, but the rabbits were tolerable to the constricted airway with a small sized needle (l6G) into the trachea for 60 minutes.

  • PDF

Effect of Inhaled Nitric Oxide on Hemodynamics, Gas Exchange and Pulmonary Inflammation in Newborn Piglets with Escherichia coli Induced Septic Lungs (패혈성 폐가 유도된 신생자돈에서 외인성 Nitric Oxide 흡입의 혈역학, 가스교환 및 폐 염증에 대한 효과)

  • Chang, Yun Sil;Ko, Sun Young;Park, Won Soon
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.8
    • /
    • pp.777-783
    • /
    • 2003
  • Purpose : The aim of this study was to evaluate the effect of inhaled nitric oxide(iNO) on gas exchange, hemodynamics and pulmonary inflammation in newborn piglets with E. coli induced septic lung. Methods : Twenty three instrumented and ventilated piglets were randomized into three groups : CON(n=6), PCON(n=9), and PNO(n=8). In the piglets of the PCON and PNO groups, E. coli septic lung was induced by endotracheal instillation of E. coli. Ten ppm iNO was given continuously in the PNO group after endotracheal instillation of E. coli. All animals were mechanically ventilated for six hour with a peak inspiratory pressure of 30 $cmH_2O$, frequency of 25 breaths/min, $FiO_2$ 1.0 and a positive end-expiratory pressure of 4 $cmH_2O$. All measurements were made at one hour intervals during the experiment. At the end of the experiment, lung tissue was harvested for the analysis of myeloperoxidase activity, indicative of lung inflammation. Results : All piglets with pulmonary instillation of E. coli developed E. coli sepsis. Piglets in the PCON group developed progresseve pulmonry hypertension, hypoxemia and hypercarbia compared to the CON group due to increased pulmonary vascular resistance, intrapulmonary shunt fraction and physiologic dead space fraction. iNO did not reverse pulmonary hypertension in the PNO group. However iNO significantly improved oxygenation, which was attributed to marked improvement of venous admixture and partial attenuation of increase in dead space fraction. Increased myeloperoxidase activity in PCON compared to CON was significantly attenuated in PNO. Conclusion : iNO improves oxygenation and lung inflammation in newborn piglets with E. coli induced septic lung.