• 제목/요약/키워드: 저감율

Search Result 1,044, Processing Time 0.03 seconds

The Relationship between Particular Matter Reduction and Space Shielding Rate in Urban Neighborhood Park (도시근린공원 미세먼지(PM)저감과 공간차폐율과의 관계 - 대구광역시 수성구 근린공원을 중심으로 -)

  • Koo, Min-Ah
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.47 no.6
    • /
    • pp.67-77
    • /
    • 2019
  • The purpose of this study is to analyze how much particulate matter at the center of the urban park is reduced compared to the entrance of the park, where the particulate matter problem is serious. It also endeavored to analyze the relationship between the space closure rate and particulate matter reduction rate in the center of the park through the collection and analysis of experimental data. Seven flat land type urban neighborhood parks in Suseong-gu, Daegu were measured at the same place for three days. The research results are as follows. First, the center of the urban neighborhood park had an average temperature 1.05℃ lower than at the entrance and an average humidity of 2.57% higher. Second, the rate of fine dust reduction was PM1- 17.09%, PM2.5- 17.65%, PM10- 14.99%. As for the reduction rate of particulate matter, the smaller the size of the park, the greater the reduction rate. In addition, the reduction rate at the center of the park was lower on days when particulate matter concentration based on the weather reports was low. The higher the concentration at the park entrance, the higher the reduction rate was. Third, a higher the rate of space closures at the center of the park resulted in a higher effect of particulate matter reduction. Noting this, the relationship between particulate matter reduction and the space closure rate in urban neighborhood parks was clearly shown. We hope to be the basis for more extensive experimental data collection.

A Study on Characteristics of Drag Reduction Additive under High Temperature Range (고온영역에서 계면활성제의 마찰저감 성능 특성에 관한 연구)

  • Cho, Sung-Hwan;Ryu, Jae-Sung;Jung, Sang-Hoon
    • Journal of Energy Engineering
    • /
    • v.19 no.2
    • /
    • pp.116-120
    • /
    • 2010
  • Overall total length of hydraulic pipe to transport the hot water in the domestic district heating network is above 3,000 Km approximately. This long pipe network requires a lots of the transport pumping power by surface friction of fluid. In this study, the drag reduction(DR) of Amin Oxide $C_{18}$ as non-ionic surfactant according to the fluid velocity, temperature and surfactant concentration under the condition of above $80^{\circ}C$ fluid temperature were investigated experimentally. Results showed that new amin oxide $C_{18}$ surfactant had DR of maximum 30% in fluid temperature of $80^{\circ}C$ and had 15% DR in fluid temperature over $100^{\circ}$ under short time test condition. And amine oxide had 155 hours duration time to keep the DR characteristic in the fluid temperature of $80^{\circ}$ and 1000 ppm concentration. But duration time of DR was decreased when fluid temperature increased.

A Study of Fault Current Distribution Ratio with a Reduction Equipment of Sheath Circulating Current (시스전류 저감장치 적용시 고장전류분류율 검토 및 대책)

  • Hong, D.S.;Jang, T.I.;Kang, J.W.;Kim, J.S.;Yoon, H.H.;Lim, H.E.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.503-505
    • /
    • 2003
  • 본 논문에서는 방전갭을 이용한 시스 순환 전류 저감장치 보호유닛을 제안하여 SVL형식의 저감장치 보호유닛과 뇌써지시 과도특성을 비교하였으며, 또한 시스 순환전류 저감장치 보호유닛 적용시의 고장전류분류율을 검토한 결과 모든 경우에 대하여 각 접지선의 고장전류분류율이 현행의 기준을 만족함으로써 시스 순환전류 저감장치 보호유닛을 적용한 저감장치의 현장적용 가능성을 제시하였다.

  • PDF

Spatial Influences of Flood Controls in Dam Operations (댐의 홍수조절에 대한 공간적 영향 분석)

  • Jung, Yong;Kim, Nam Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.3
    • /
    • pp.407-415
    • /
    • 2018
  • This study analyzed the role of dams for the flood control by the observed and simulated hourly flood discharge data. The study area was the Nakdong river basin with Andong and Imha dams. For the analysis 31 flood events from 1997 to 2010 were selected. In the analysis of the flood reduction rate (FRR) of dam itself, the FRR was not decreased with higher size of floods which is not as we expected. In order to see the trend of flood reduction rate depending on the flood size, flood discharge volume presents it better than peak flood discharge. In the comparison of the flood reduction effects of the two dams, Andong dam has 7% larger flood reduction influence at the Sungju gauging station (SGS) located farthest from the selected watershed. Comparing the ratio of the watershed area based on the covered size of the SGS, the FRR of dam is smaller than the area rate. The impact of FRR of dam showed that the FRR fell below 10% when reaching the size of watershed area corresponding to 8.5 times of the size of watershed area of the dam which is larger than Namhan river basin (7 times).

Comparison of efficiency the grounding resistance enhancement materials used organic.inorganic composite (유.무기 복합재료를 이용한 접지저감제의 성능 비교)

  • Cho, D.H.;Lee, K.S.;Kim, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.66-72
    • /
    • 2004
  • 본 연구는 접지저감제의 성분으로 수용성 고분자의 유기물과 층상형 점토의 무기재료를 주재료하여 새롭게 개발한 새로운 형태의 접지저감제의 성능비교에 관한 것이다. 신개발의 접지저감제는 수분을 흡습하여 수분에 용해된 수용성고분자가 수분과 함께 층상형점토의 층으로 삽입되어 접지저감 성능을 발휘하게 된다. 본 연구의 유 무기 복합재료형 접지저감제는 함수율과 팽창률이 매우 우수할 뿐 아니라 300wt%의 수분을 공급 후 측정한 전기전도도도 매우 뛰어나다. 또한 환경친화적인 천연재료들이므로 인체나 환경에 매우 안전하며, 접지전극의 부식과 전식을 방지하는 기능이 매우 뛰어나 염해나 화학적으로 부식성이 높은 토양에서 큰 장점을 갖는다. 본 논문에서는 신개발의 접지저감제와 기존의 여러 접지저감의 성능을 비교 분석하였다. 이를 위해 현장의 대지저항율을 측정 분석하여 각각의 접지저감제의 접지설계에 적용하여 시뮬레이션하였으며, 시뮬레이션 결과와 현장에서 실제 시공한 측정 결과와 비교 분석하였다.

  • PDF

Performance Evaluation of Eco-friendly Permeable Block Using Basalt Waste Rock (현무암 폐석을 이용한 친환경 투수블록의 성능평가)

  • Sang-Soo Lee;Hyeong-Soon Kwon;Jae-Hwan Kim
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.4
    • /
    • pp.299-306
    • /
    • 2023
  • Environmental pollution problems are occurring due to the negative treatment of basalt waste in Jeju Island. This study identifies the characteristics of permeable block with basalt with physical and chemical adsorption mechanisms and examines their applicability and functionality as building materials. This experiment is basic data for evaluating the functionality of the permeable block by analyzing flexural strength, compressive strength, permeability coefficient, carbon dioxide, and fine dust adsorption rate by producing a permeable block using a basalt waste rock. As the basalt waste stone replacement rate increased, the flexural strength and compressive strength tended to decrease, and as the replacement rate increased, the water permeability coefficient, absorption rate, carbon dioxide, and fine dust adsorption rate tended to increase. Therefore, it is judged that the permeable block using the basalt waste rock is superior to the existing permeable block.

A Study on Cogging Torque Reduction by Teeth Notching and Permanent Magnet offset in Surface-mounted Permanent Magnet Synchronous Motor (표면부착형 영구자석 동기전동기의 노치 및 영구자석 offset에 의한 코깅토크 저감 연구)

  • Kim, Tae-Woo;Chang, Jung-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.969-970
    • /
    • 2011
  • 본 논문은 표면부착형 영구자석 동기전동기(Surfacemounted Permanent Magnet Synchronous Motor)의 영구자석 offset의 변화와 노치(notch)의 적용에 따른 코깅토크 저감 특성을 분석하고, 중심합성계획법(Central Composite Design)을 이용한 최적 모델 설계에 대한 연구이다. 영구자석 offset만 적용한 모델의 경우 코깅토크의 피크-피크값은 95%로 크게 저감되었지만 정격전류 인가시 평균토크의 감소율이 12.3%로 출력 손실이 크기 때문에 최적 설계를 통해 추가적으로 노치를 적용하고 영구자석 Offset을 조절함으로써 코깅토크 저감율을 96.5%로 개선시킬 수 있었고, 평균토크의 감소율은 7.7%로 영구자석 offset만 적용한 모델보다 평균토크의 감소량이 작아진 것을 확인할 수 있었다.

  • PDF

Development of forest carbon optimization program using simulated annealing heuristic algorithm (Simulated Annealing 휴리스틱 기법을 이용한 임분탄소 최적화 프로그램의 개발)

  • Jeon, Eo-Jin;Kim, Young-Hwan
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2013.07a
    • /
    • pp.423-426
    • /
    • 2013
  • 본 연구에서는 임분 단위에서 산림의 이산화탄소 흡수 및 저장 기능을 최적화 할 수 있는 최적의 산림시업체계를 도출하고자하였고, 이를 위해 임분 생장모델과 Simulated Annealing 휴리스틱 기법을 적용하여 임분탄소 최적화 프로그램을 개발하였다. 휴리스틱 알고리즘에서 최적해를 찾기 위해 반복 실행 되는 과정에서 더 이상 최적해을 찾지 못하고 목표 값이 어떤 일정한 값(Local Optimum)에 계속 머무는 현상을 해결하기 위해 임계치를 적용하며, SA 휴리스틱 기법에서는 열균형테스트를 이용하고 있다. 개발된 프로그램을 이용하여 3가지 산림 시업 시나리오에 대한 비교 분석을 실시하기 위해 프로그램을 실행한 결과, 목재수확량의 경우 목재수확량을 최대를 목표로 한 대안이 3개 시나리오 가운데 목재수확량이 가장 높은 것으로 나타났으며, 또한 탄소저장량에서도 탄소저장량을 최적화한 대안이가 탄소저장량이 가장 높은 것으로 나타나 프로그램이 목적에 맞게 개발된 것으로 판단됐다. 또한 열균형 테스트의 온도저감율을 조정하여 프로그램을 반복실행하여 온도저감율이 프로그램 실행 시에 미치는 영향을 분석한 결과 온도저감율에 따라 출력되는 목적함수의 최적값과 프로그램 반복횟수가 영향을 받는 것으로 나타나 프로그램 실행을 최적으로 하기위해 온도 저감율의 파라미터 값을 0.1로 설정하였다.

  • PDF

A Study on Runoff Reducing Efficiency of Infiltration Collector Well Installation for Heavy Rainfall Event (호우사상에 대한 침투통의 우수유출저감효과에 관한 연구)

  • Im, Jang-Hyuk;Yeoun, Ji-Woong;Shim, Jae-Hyun;Song, Jai-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1300-1304
    • /
    • 2006
  • 최근 침투형 우수유출저감시설은 물 순환 및 초기우수관리 문제, 치수 목적으로 사용이 증대되고 있으며, 시설 확대를 위한 관련 법규나 기준이 강화되고 있는 실정이다. 본 연구에서는 호우사상에 대한 침투통의 저감효과를 분석하여 우수유출저감시설로써 적용성과 치수효과를 검증하는데 그 목적이 있으며, 연구방법으로는 실제 호우사상에 대해 침투통의 현장계측을 이용하여 유출 저감율을 측정하고, 수문해석에 의해 저감효과를 분석하였다. 현장계측을 실시한 전주지역의 2005년 8월 2일 호우사상은 290.5mm를 나타냈으며, 이 강우량은 $\ulcorner$한국확률강우량도(한국건설기술연구원, 2000)$\lrcorner$에 의한 전주관측소 50년 빈도 24시간 확률강우량 287.7mm를 초과하는 값으로 분석되었다. 이 때, 총유출저감율은 약 56%로 측정되었으며, 유역특성이 비슷한 지역에서는 해당 강우량에 대해 유사한 저감효과를 나타낼 것으로 판단된다. HEC-HMS와 단위침투설계법을 이용하여 수문해석을 실시하였으며, 동일한 호우사상 자료를 적용한 결과, 총유출저감량은 20.64%, 최대 첨두유량은 6%의 저감율을 나타냈다. 향후 지속적인 모니터링과 첨두유량에 대한 연구가 보완되고 호우사상에 대한 계측자료가 추가로 확보된다면 호우사상에 대한 침투통의 치수효과를 정량화할 수 있을 것으로 판단된다.

  • PDF

Development of the New Hormonic Eliminating Device Using Zig-Zag Connection and Open-Delta Mode (Zig-Zag 결선 및 Open-Delta 방식을 이용한 새로운 고조파 저감장치의 개발)

  • Lee, Sung-Ho;Kim, Gi-Sung;Yoo, Sang-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.169-174
    • /
    • 2005
  • The conventional harmonic filters to reduce zero harmonic current from neutral reactors and Zig-Zag connection, have several disadvantages of the decreased reduction rate of harmonics under a light load, because they have the load factor-dependent reduction rate of harmonics, and the risk of potential breaking in the neutral line by heated neutral reactor. Based Zig-Zag connection and Open-Delta mode, this new harmonic eliminating device (HANOS) adopts the combination of Zig-Zag connection and Open-Delta mode-the latter is additionally applied to the transformer's core block for connection to the neutral line. The results of this study demonstrated that the new device could eliminate safely zero harmonic current running in the neutral line without heating.