• Title/Summary/Keyword: 재포기 계수

Search Result 3, Processing Time 0.017 seconds

Reproducibility of Reaeration in Sewer using Batch Reactor Test (실험반응조를 이용한 하수관에서의 재포기현상 재현 가능성에 관한 연구)

  • Hwang, Hwankook;Min, Sangyun;Cho, Jinkyu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.8
    • /
    • pp.45-50
    • /
    • 2014
  • The microorganism decomposition experiment of sewage in the underground sewer has the limit of experiment condition and time. The way to reproduce the microorganism decomposition in the underground sewer was studied using batch reactor setting up the DO as a limiting condition. The DO concentration in the sewer is controlled by reaeration. It is possible to obtain correlation between flow condition and reaeration coefficient through the reproduction of reaeration phenomenon by controlling the flow condition in the sewer using this phenomenon. And it is possible to set the flow condition and agitation intensity (velocity gradient) that has the same reaeration coefficient using the correlation between the reaeration coefficient with the flow condition and reaeration coefficient with the agitation intensity. The circumstances in the sewer system was reproduced using batch reactor setting up the DO as a limiting condition from these results.

Estimation of Dissolved Oxygen in Streams using Reaeration, 1st Production and Respiration Rates (재포기 계수, 1차 생산율 및 호흡률을 이용한 하천의 용존산소 추정)

  • Kim, Kyung-Sub;Hwang, Sung-Gyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.6
    • /
    • pp.428-433
    • /
    • 2009
  • Dissolved oxygen is considered as one of the important water-quality constituents in streams from one century ago and fishes perish in low dissolved oxygen concentration. Environmental scientists and engineers have introduced the deterministic model to estimate dissolved oxygen concentration of streams and recommended the use of the Delta Method (DM), Approximate Delta Method (ADM), Extreme Value Method (EVM) and Optimization Method (OPT) which can be applied in no spatial variation of dissolved oxygen. The diurnal or annual variation of dissolved oxygen is mainly determined from the parameters such as reaeration rate, 1st production rate and respiration rate which are related to dissolved oxygen. Each method was briefly introduced and applied to two sampling sites of Anseong Stream watershed in this paper. The limitation, advantages and disadvantages of each method were reviewed and analyzed after running the each method. From these analyses, the benefit-cost approach to estimate dissolved oxygen effectively in streams was recommended.

Optimum Sample Size for Development of Reaeration Coefficient Equation in Stream Water Quality Modeling (강물의 수질오염 modeling에 사용되는 재포기계수공식 개발을 위한 적정규모의 표본의 크기)

  • ;Charles S. Melching
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.38 no.4
    • /
    • pp.155-167
    • /
    • 1996
  • 동일한 하천의 용전산소량(DO)을 예측하는 경우에도 사용하는 재포기계수$(K^2)$는 계산하는 공식에 따라 커다란 차이를 나타매며, 부적합한 공식의 사용에 의한 $(K^2)$의 계산은 하천의 수질관리 정책결정에 지장을 초래하므로 현장사정에 적합한 공식의 개발이 필요하다. 이러한 공식의 개발은 많은 현장측정 자료를 사용하도록 신뢰성이 높으나 현장측정은 소요되는 비용에 제약을 받기 때문에 신뢰성과 경제성을 동시에 고려한 표본의 크기의 적정규모를 산정하는 것이 필요하다. 본 연구에서는 Monte Carlo 방법에 의해 통계적으로 수출된 $(K^2)$를 사용해서, 주어진 자료에 의해 개발된 공식을 사용할 때 야기되는 오차가 $(K^2)$개수의 증가에 따라 얼마나 감소하는지를 널리 사용되는 공식 중에 Owen공식과 Churchill공식을 New Jersey에 있는 Passaic River에 적용시켜 검토하였다. 표본의 크기가 10에서 20으로 증가할 때 오차가 크게 감소하였으며 20을 넘어 증가시켰을 때에는 오차의 감소폭이 미미하였다. 초차의 감호형태와 단위측정당 소요되는 비용을 고려할 때 약 20정도의 표본의 크기가 적정수준의 규모에 판단된다. 이러한 적용사례의 결과는 회귀모델의 이론적 계산결과에 의한 오차 감소와 흡사하여 본 연구결과는 여러 가지(K2)공식과 광범위한 하천의 조건에 적용이 가능할 것이며, 본 연구에서 사용한 적정표본의 크기 산정방법은 회귀분석에 의해 실험식을 개발하는 다른 분야에도 적용이 가능하다.

  • PDF