• Title/Summary/Keyword: 재순환량

Search Result 341, Processing Time 0.031 seconds

A Study on the Combustion Flow Characteristic and NOx Reduction of the Exhaust Gas Recurculation Burner using Coanda Nozzles (코안다 노즐을 이용한 배기가스 재순환 버너의 연소 유동 특성 및 NOx 저감에 관한 연구)

  • Ha, Ji Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.3
    • /
    • pp.53-60
    • /
    • 2017
  • Various researches have been conducted for the reduction of NOx at the combustion furnace and exhaust gas recirculation method is commonly used technology for NOx reduction. The present research adopted coanda nozzles at the outside pipes of furnace to entrain the exhaust gas for the exhaust gas recirculation and the mixed gas was ejected to the tangential direction to cause the swirl flow in the furnace. The combustion flow characteristics in the exhaust gas recirculation burner with coanda nozzle has been elucidated by analyzing the swirl flow streamlines, temepraure and reaction rate distribution in the furnace. The exhaust gas entrained flow rate has been investigated by changing the excess air factor and coanda nozzle gap and the exhaust gas entrained flow rate increased with the increase of excess air factor and it decreased with the increase of coanda nozzle gap. The mean temperature at the exit plane of exhaust gas decreased with the excess air factor and it was little affected by the increase of coanda nozzle gap. The NOx mass fraction at the exhaust gas exit plane remarkably decreased with the excess air factor and it was also little affected by the increase of coanda nozzle gap.

Estimation of Uranium Requirements Based on Future Reactor Strategies

  • Hahn, Do-Hee;Chung, Chang-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.22-35
    • /
    • 1981
  • The U$_3$O$_{8}$ requirements are estimated for the high, intermediate, and low growth projections of nuclear power in Korea. To each projection, four illustrative reactor-mix strategies and four fuel cycle options are applied for estimating the requirements. The reactor types considered are PWR, PHWR. and FBR. The fuel cycles considered are once-through cycle, U/Pu recycle, and improved once-through cycle. Also the amount of Pu-fissile recovered from U recycle is estimated. The maximum cumulative (to the year 2000) requirements of U$_3$O$_{8}$ occupy about 4 to 5 percent of the WOCA requirements and are about 23 times larger than the U$_3$O$_{8}$ resources in Korea. For the high nuclear power growth projection, the cumulative amount of Pu-fissile recovered from U recycle is sufficient for the startup of 2 units of 1200 MWe fast reactors by the year 2000. 2000.

  • PDF

Promotion plan of water circulation improvement project in the basin unit for improving the integrated water resources management (통합물관리 실현을 위한 유역단위의 물 안심공간 사업 추진방안)

  • Min Woo Lee;Sang Whoing Lee;Jin Won Park
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.253-253
    • /
    • 2023
  • 유역의 수량, 수질, 수생태, 지하수, 하천환경, 기후변화, 오염원, 하천 친수공간, 농업경작지 등 수자원 관점의 물순환의 범위를 넘어서 환경, 기후변화 적응, 경제성, 사회문화 등 다양한 분야를 포함한 통합적인 유역의 물관리 이슈와 문제점을 해결할 필요가 있다. 물순환 관리의 개념은 국토개발과 도시화에 따라 파생된 물순환 왜곡 및 그에 따른 제반 물문제(홍수량 증가에 따른 침수피해, 직접 유출량 증가에 따른 가용 수자원의 감소 등)의 해결을 위한 물관리 행위 전체로 볼 수 있다. 물순환 관리의 범위는 홍수량 감소를 위한 홍수관리, 가용 수자원의 증대를 위한 물 확보 등 물관리 전반을 포함해야 한다. 기존의 물순환 사업은 비점오염 관리에 중점을 두고 LID를 활용한 빗물 침투율 증대와 빗물 재이용 등의 관련 정책을 추진하였으나 이는 물순환 체계 전반을 다루고 있지 못하고 수질 개선에그 효과가 집중되었다. 따라서, 수량·수질·수생태·재이용 등을 종합적으로 고려한 물순환 관리에 대한 연구가 필요하며, 이를 통하여 개별적이고 시설물 중심인 기존 대책의 한계를 극복하고 통합물관리 관점의 물순환 건전성을 기반으로 유역의 안심공간 조성방안을 수립할 필요가 있다. 본 연구에서는 물순환 전반을 연계한 통합적인 물관리를 통하여 물 안심공간을 조성하기 위한 토대를 제시하는 것을 목표로 하며, 통합물관리 관점의 물순환 관련 데이터 수집, 유역별 물순환 수준의 진단 및 평가를 통하여 시범사업 모델을 마련하고, 사업에 따른 효과분석을 기반으로 중장기 추진계획 수립을 통한 실행력을 확보하는 것을 목적으로 한다.

  • PDF

A Study on the Cold Flow Characteristics of a Flue Gas Recirculation Burner with Both Outlets Opening (양쪽 출구가 트인 배기가스 재순환 버너의 냉간 유동 특성에 관한 연구)

  • Ha, Ji Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.3
    • /
    • pp.7-12
    • /
    • 2018
  • Thermal NOx is generated in a high temperature environment in a combustion facilities. Exhaust gas recirculation method is widely used among various methods for reducing nitrogen oxides in combustion devices. In the present study, the computational fluid dynamic analysis was accomplished to elucidate the cold flow characteristics in the flue gas recirculation burner with both outlets opening. Because the reciculation pipes is installed toward the tangential direction, the swirling flow is formulated in the burner and the phenomenon of the reverse flow creation is detected at the center area of circular burner. We are confirmed that this is the similar trend with the burner with one side outlet closed. From the present study, it was seen that the recirculated inflow from both recirculated burner outlets increased by about 5% compared to the burner with one side outlet opening. At the outlet located at the exhaust gas recirculation pipe inlet(gas exit 1), the inlet flow was formed in the entire region. At the opposite outlet(gas exit 2), the total flow was discharged, but the center part of the burner was observed to have a reverse flow. The flow rate at the gas exit 2 was 3 ~ 5 times larger than the flow rate at the gas exit 1.

Evaluation of Impurity Content Criteria of Recycled Aggregate for Lean Concrete Base (빈배합 콘크리트 기층용 순환골재의 이물질 품질기준 적정성 연구)

  • Kim, Nam-Ho;Yang, Seung-Cheol
    • International Journal of Highway Engineering
    • /
    • v.14 no.3
    • /
    • pp.69-76
    • /
    • 2012
  • A recent shortage in Korean aggregate market leads a social demand to utilize recycled aggregate to more advanced level, such as the use in concrete structures or paving materials for surface and base layers. Government announced a recycled aggregate guideline in 2009 to provide an institutional framework for recycled aggregate in such an up-scaled use. The use of recycled aggregate in such use; however, is very minimal. This paper evaluates the validity of the impurity content criteria of recycled aggregate for lean concrete base through a series of material tests. The analysis results shows that reclaimed asphalt pavement (RAP) in recycled aggregate not only influence a strength lean concrete adversely, but also influence negatively on an absorption and abrasion characteristics of aggregate system significantly that made those two indices lower. Since absorption and abrasion characteristics are very important indices for recycled aggregate quality, RAP in recycled aggregate could significantly mislead the recycled aggregate qualification. This paper provides a suggestion to resolve these problems.

A Study on Flame Stabilization in the Axisymmetric Curved Wall Jet (축대칭 곡면벽 제트 유동장에서 화염 안정화에 관한 연구)

  • Gil, Yong-Seok;Cha, Min-Seok;Song, Yeong-Hun;Han, Jae-Won;Jeong, Seok-Ho
    • 한국연소학회:학술대회논문집
    • /
    • 1997.06a
    • /
    • pp.51-60
    • /
    • 1997
  • 축대칭 곡면벽 제트 버너를 제작하여 화염의 안정화 특성을 실험적으로 연구하였다. 축대칭 곡면벽 제트 유동은 난류 강도의 증가와 더불어 버너 선단 부근에 재순환 영역을 형성하여 화염의 안정화를 촉진시킴으로서 기존의 튜브 버너에 비하여 화염의 안정화 특성이 향상되었다. 시간적으로 화염의 위치가 변동하는 난류 화염에서 화염의 안정화 특성과 밀접한 관계가 있는 OH 라디칼과 온도를 PLIF와 CARS를 각각 적용하여 측정하였다. 고유속으로 연소시키는 경우에 버너 선단에 형성된 재순환 영역에 OH 라디칼이 상당량 분포하고 있었으며 통계적으로 고온을 유지하였다. 이는 버너 선단에 형성되는 재순환 영역에 고온의 기연 가스가 점화원 역할을 하여 화학 반응이 활발하게 일어나고 있음을 의미한다. 이러한 결과로부터 고속의 출구유속에서 화염 안정화 특성은 재순환 영역에 의하여 영향을 받고 있음을 확인하였다.

  • PDF

Study on flow characteristics downstream of submerged weir (수중보 하류 흐름 특성 연구)

  • Choi, Sung-Uk;Ban, Chaewoong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.94-94
    • /
    • 2019
  • 보의 주요한 기능은 수위 및 유량을 조절이며, 수심을 확보하거나 하상 경사를 조절하기 위하여 설치된다. 보의 설치는 평균 흐름뿐만 아니라 강한 난류 흐름을 생성한다. 보의 실용적인 측면에도 불구하고, 이러한 흐름의 교란은 보의 상류뿐만 아니라 하류에 하상 변화를 초래한다. 이는 종종 하천의 안정뿐만 아니라 보 자체의 안전에도 영향을 미친다. 보 하류의 국부 세굴은 보를 지나는 3차원 흐름 특성을 가지는 복잡한 조직구조에서 기인한다. 특히, 이러한 흐름은 보에서 발생하는 큰 박리 흐름과 이어서 나타나는 재순환 영역 및 강한 하강류로 특징지을 수 있다. 보 하류 흐름에 관한 많은 실험 및 수치모의 연구가 수행되어왔다. 그러나 실험은 보 또는 하상과 같은 벽 경계면과 수면 근처의 세밀한 흐름 특성을 파악하기 어렵다. 또한, 기존의 RANS (Reynolds averaged navier-stokes) 모형은 조직구조와 같은 3차원 흐름 특성을 파악하기에 적합하지 않다. 본 연구에서는 큰 와 수치모의 (large eddy simulation)을 이용하여 세굴공이 발달한 경우와 그렇지 않은 경우의 보 하류의 흐름 특성을 분석하였다. 보에 의해 발생한 재순환 흐름은 세굴공이 발달하면서 그 영역이 확장되며, 재순환 흐름의 하강류의 세기는 약해지는 것을 확인할 수 있었다. 또한, 세굴공이 발달하면서 최대 세굴심의 위치는 재순환 흐름의 하단 끝 부분과 일치하는 것으로 나타났다.

  • PDF

The Effect of Mass Transfer on the Cure Properties of the Urea Resin Moulding Compounds Under the Drying Process (건조 공정 중 요소 수지 성형재료의 경화 특성에 대한 물질전달 효과)

  • Kim, Sang Yeul;Choi, Il Gon;Kim, Byoung Chul
    • Korean Chemical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.681-686
    • /
    • 2002
  • In the industrial field, the theory of drying process is different from the practical application, and it is effective to reduce energy by recirculation of the heat of exhausting gas. But the study of this field may not be performed still. The cure properties of the urea resin moulding compounds was investigated according to drying temperature, drying time, recycle rate of exhausting gas and moulding temperature in the process of drying and moulding. We obtained the following results; water content of material decreases with increasing drying time and drying temperature, and the rate of drying also decreases with increasing recycle rate of exhausting gas. Specially, The cure fluidity of the urea resin moulding compounds decreases, with increasing drying temperature, recycle rate of exhausting gas and moulding temperature. And the correlation equations on water content and cure fluidity of the urea resin moulding material were obtained through a regression analysis of experimental data.

The Experimental Study on the Plaster mortar using Recycled fine aggregate (순환잔골재를 사용한 미장용 모르타르에 관한 실험적 연구)

  • Lee, Dae-Geun;Han, Sang-Il;Choi, Duck-Jin;Kang, Cheol;Kim, Jun-Seok;Kim, Jin-Man
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.473-476
    • /
    • 2008
  • The use of the recycled fine aggregate to the material of structural concrete is not easy currently because there are some problems, such as the difficulty of quality control and the badness of chemical and physical property other than river sand, crushed fine aggregate. To use of recycled fine aggregate, many researches on the recycling of recycled fine aggregate have been studying until today. However, the result of the research is little except for some results. Therefore, the purpose of this study is to confirm the possibility of use of recycled fine aggregate for raw material of plaster mortar. In this study, various tests were performed such as flow, air content, unit weight, bond strength, and compressive strength test to evaluate the effect according to the substitution of recycled concrete aggregate. The results of strength test showed that the concrete strength improved with the increase of replacement ratio of recycled fine aggregate. In the other side, flow and air content are decreased according to replacement ratio of recycled fine aggregate. The result of this study could be used as the basic data for the recycling of recycled fine aggregate.

  • PDF

A Fundamental Study of Hybrid Combustion System Applying Exhaust Gas Recirculation (배기가스 재순환을 적용한 하이브리드 연소시스템에 대한 기초 연구)

  • Oh, Wheesung;Yu, Byeonghun;Park, Taejoon;Lee, Chang-Eon
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.100-107
    • /
    • 2016
  • In this study confirmed the reduction effect of pollutant by applying Fi-EGR and FPI-EGR to hybrid combustion system realizing premixed flame and non-premxied flame at once. The results showed that NOx emission index decreased significantly in case of adopting EGR. Additionally, the hybrid combustion system with EGR resulted in a better performance compared to usual non-premixed combustion system such that it can reduce $NO_x$ emission at equivalent EGR ratios. Especially, in the case of 25% of FI-EGR ratio at hybrid combustion system that the ratio of non-premixed and premixed is 50 : 50, NOx emission index reduction rate was about 59% compared to $NO_x$ emission of non-premixed combustion system without EGR and in the case of 15% of FPI-EGR ratio at hybrid combustion system that the ratio of non-premixed and premixed is 70 : 30, $NO_x$ emission index reduction rate was about 48% compared to $NO_x$ emission of hybrid combustion system without EGR.