• Title/Summary/Keyword: 장기운전

Search Result 224, Processing Time 0.026 seconds

Heat-up Calculation for the Auxiliary Feed Water Pump Room at Ulchin Units 3 and 4 for Loss of HVAC Accidents (HVAC 상실사고시 울진원전 3/4 호기의 보조급수펌프 격실 온동상승 평가)

  • Yoon, Churl;Park, Jin-Hee;Hwang, Mee-Jeong;Han, Sang-Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.5
    • /
    • pp.553-562
    • /
    • 2012
  • Computational Fluid Dynamics (CFD) analysis has been performed to estimate the air temperature inside an Auxiliary Feed Water (AFW) Motor-Driven (MD) pump room for the case where there is loss of Heating, Ventilation, and Air-Conditioning (HVAC). A transient calculation for the closed pump room without cooling by any HVAC system shows that the volume-averaged air temperature reaches around $60^{\circ}C$ for a transient period of 8.0 h. From previous studies, the external air and surface boundary temperatures are assumed to increase slowly starting from an initial temperature of $35^{\circ}C$. For the cases where the door is opened at 2, 4, and 6 h after the initiation of HVAC failure, the average air temperature promptly drops by about $4^{\circ}C$ when the door is opened and then slowly increases. The current calculations based on the CFD technique predict the rate of increase of air temperature to be lower than that determined by previous conservative calculations on the basis of a lumped model.

A study on efficient management of the drainages of underground tunnels for environmentally friendly urban railway systems (도시철도 친환경 지하터널 배수형식의 효율적인 유지관리 방안 검토)

  • Baek, Jong-Myeong;Hong, Jong-Hun;Kim, Han-Bae
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1982-1990
    • /
    • 2010
  • Excepting tunnel of dorimstream - ccachimountain station section, the subway line No.2th section was build using ASSM and NATM methods because of soil pressure and land condition. The way of dealing underground water was selected without sufficient preconsideration of geographical features, ground condition, influence of lowing underground water, and long-term cost of running maintenance so that the form of undrained tunnel was build having decreased construction characteristics and technically improper elements. The form of partial drainage is very difficult to manage structures of tunnel, because water leakage, water pressure causing cracks of lining concretes and scaling are constantly happened. so partial drainage suggest that setting reinforced Anchor Bolt to prevent buoyancy and should increase center drainage way up to height of railroad. Partial drainage suggest that holey pipe(${\phi}$350mm) manhole, drainage checking pipe manhole are should be regularly dredged, when changing roadbed(gravel${\rightarrow}$concrete) drainage checking pipe manhole should be build and setting a limitation of entering underground water's quantities. Beside drainage degree in changed section of structures causing instability of structures is continuous degree. so if efficient drainage way and the patterns of flaws, problems are considered in survey, it will be expected to have a advantage condition in maintenance part.

  • PDF

Experimental Study on Compression/Absorption High-Temperature Hybrid Heat Pump with Natural Refrigerant Mixture (천연혼합냉매를 이용한 압축/흡수식 고온히트펌프의 실험적 연구)

  • Kim, Ji-Young;Park, Seong-Ryong;Baik, Young-Jin;Chang, Ki-Chang;Ra, Ho-Sang;Kim, Min-Sung;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1367-1373
    • /
    • 2011
  • This research concerns the development of a compression/absorption high-temperature hybrid heat pump that uses a natural refrigerant mixture. Heat pumps based on the compression/absorption cycle offer various advantages over conventional heat pumps based on the vapor compression cycle, such as large temperature glide, temperature lift, flexible operating range, and capacity control. In this study, a lab-scale prototype hybrid heat pump was constructed with a two-stage compressor, absorber, desorber, desuperheater, solution heat exchanger, solution pump, liquid/vapor separator, and rectifier as the main components. The hybrid heat pump system operated at 10-kW-class heating capacity producing hot water whose temperature was more than $90^{\circ}C$ when the heat source and sink temperatures were $50^{\circ}C$. Experiments with various $NH_3/H_2O$ mass fractions and compressor/pump circulation ratios were performed on the system. From the study, the system performance was optimized at a specific $NH_3$ concentration.

Synthesis of C9-Alcohol through C9-Aldehyde Hydrogenation over Copper Catalysts (구리 촉매 상에서 C9-알데히드의 수소화 반응에 의한 C9-알코올 합성)

  • Park, Young-Kwon;Noh, Sang Gyun;Cho, Kyu Sang;Jeon, Jong-Ki
    • Korean Chemical Engineering Research
    • /
    • v.44 no.4
    • /
    • pp.363-368
    • /
    • 2006
  • This study selected the optimal catalyst for the process of producing $C_9$-alcohol by hydrogenating $C_9$-aldehyde, and carried out an experiment in order to establish the operating condition for maximizing the yield of $C_9$-alcohol. The BET surface area and the specific area of copper were most excellent in $CuO/ZnO/Al_2O_3$ (60:30:10 wt%) catalyst produced using acetate as a precursor of copper and $Na_2CO_3$ as a precipitant, and the catalyst also showed the highest performance in $C_9$-aldehyde hydrogenation. Using a trickle bed reactor loaded with optimized catalyst, we attained 94.1 wt% yield of $C_9$-alcohol under the condition of $175^{\circ}C$, 800 psi and $WHSV=3hr^{-1}$. According to the result of comparing with other catalysts used in the hydrogenation of aldehyde, the catalyst showed similar performance to that of Ni/kieselghur and higher than that of $Cu-Ni-Cr-Na/Al_2O_3$ and $Ni-Mo/Al_2O_3$. According to the result of examining the stability of the catalyst through a long-term catalysis test, the yield of $C_9$-alcohol decreased slowly after around 72 hours due to the increasing production of high boiling-point byproducts.

Performance of High Temperature Filter System for Radioactive Waste Vitrification Plant (방사성폐기물 유리화 플랜트 고온여과시스템의 성능 특성)

  • Seung-Chul, Park;Tae-Won, Hwang;Sang-Woon, Shin;Jong-Hyun, Ha;Hey-Suk, Kim;So-Jin, Park
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.3
    • /
    • pp.201-209
    • /
    • 2004
  • Important operation parameters and performance of a high temperature ceramic candle filter system were evaluated through a series of demonstration tests at a pilot-scale vitrification plant. At the initial period of each test, due to the growth of dust cake on the surface of ceramic candles, the pressure drop across the filter media increased sharply. After that it became stable to a certain range and varied continuously proportion to the face velocity of off-gas. On the contrary, at the initial period of each test, the permeability of filter element decreased rapidly and then it became stable. Back flushing of the filter system was effective under the back flushing air pressure range of 3∼5 bar. Based on the dust concentrations measured by iso-kinetic dust sampling at the inlet and outlet point of HTF, the dust collection efficiency of HTF evaluated. The result met the designed performance value of 99.9%. During the demonstration tests including a hundred hour long test, no specific failure or problem affecting the performance of HTF system were observed.

  • PDF

An Analysis of the Application Technology of Heat Recovery System from Dyeing Wastewater (염색폐수 열회시스템 적용기술 분석)

  • 장기창;박성룡;이상남;라호상;박준택;함성원;박영태
    • Journal of Energy Engineering
    • /
    • v.10 no.3
    • /
    • pp.195-205
    • /
    • 2001
  • A great deal of energy is necessary with emission of lots of wastewater in dyeing and finishing process, but heat recovery from wastewater is not introduced since is technology is not developed yet. In order to obtain the method utilizing hot water produced by heat source, that is, dyeing wastewater it was investigated the characteristics of dyeing and finishing process and energy basic unit. Energy basic unit of polyester/cotton (T/C), polyester/rayon (T/R) and polyester dyeing process are higher than that of the other process. The average quantity of wastewater for each dyeing company is 20,470 ton/month, the average temperature of wastewater is about 41$^{\circ}C$. Because the SS solution of wastewater in polyester dyeing process is lower than that of the other process, the effect of corrosion in heat recovery system is low. Since the energy price for 1000 kcal produced by vapor compression heat pump is presumed to be 22.50 won, it is found to be very economic heat recovery system, and its payback is 2.09 years for the factory with LNG boiler.

  • PDF

Effect of the Sulfur Removal in Manufacturing Pt/C Electrocatalysts on the Performance of Phosphoric Acid Fuel Cell (인산형 연료전지용 백금촉매제조에서 황의 제거에 따른 전극 성능)

  • Shim, Jae-Cheol;Lee, Kyung-Jik;Lee, Ju-Seong
    • Applied Chemistry for Engineering
    • /
    • v.9 no.4
    • /
    • pp.486-490
    • /
    • 1998
  • Pt/C powder which was used as electrocatalyst in a Phosphoric Acid Fuel Cell(PAFC) was fabricated by colloid method. It was reported that the sulfur from reductant, $Na_2S_2O_4$, worked as a poison against catalyst during long term operation. To remove these sulfurs, we try to treat Pt/C powder by three different methods. First, we tried to remove the sulfur according to temperature and time in $H_2$ atmosphere. As the heat treatment temperature is raised up, the effect of the removal is increased but the electrode performance is decreased because of the growth of Pt particle size. The optimal heat treatment temperature is $400^{\circ}C$, the size of Pt particle is approximately $35{\sim}40{\AA}$ and the electrode performance is $360mA/cm^2$ at 0.7 V. At $400^{\circ}C$, even though the time of heat treatment is extended, size of Pt, amounts of remaining sulfur and electrode performance is almost constant. Secondly, when we removed in a crucible at $900^{\circ}C$ the removal of the sulfur was not better, but the size of Pt particle, approximately $80{\AA}$, was smaller than that of heat treatment in $H_2$ atmosphere at $900^{\circ}C$. Lastly we treated with solvents such as acetone, benzene, and carbon disulfide. It was observed that sulfur components were removed partly by extraction with solvents, the electrode performances were similar each other.

  • PDF

Analysis of an Immobilized β-Galactosidase Reactor with Competitive Product Inhibition Kinetics (경쟁적 저해를 갖는 고정화 β-galactosidase 반응기의 해석)

  • Kang, Byung Chul
    • Journal of Life Science
    • /
    • v.23 no.12
    • /
    • pp.1471-1476
    • /
    • 2013
  • The present study deals with the immobilization of Kluyveromyces lactis ${\beta}$-galactosidase on a weak ionic exchange resin (Duolite A568) as polymer support. ${\beta}$-Galactosidase was immobilized using the adsorption method. A kinetic study of the immobilized enzyme was performed in a packed-bed reactor. The adsorption of the enzyme followed a typical Freundlich adsorption isotherm. The adsorption parameters of k and n were 14.6 and 1.74, respectively. The initial rates method was used to characterize the kinetic parameters of the free and immobilized enzymes. The Michaelis-Menten constant ($K_m$) for the immobilized enzyme (120 mM) was higher than it was for the free enzyme (79 mM). The effect of competitive inhibition kinetics was studied by changing the concentration of galactose in a recycling packed-bed reactor. The kinetic model with competitive inhibition by galactose was best fitted to the experimental results with $V_m$, $K_m$, and $K_I$ values of 46.3 $mmolmin^{-1}mg^{-1}$, 120 mM, and 24.4 mM, respectively. In a continuous packed-bed reactor, increasing the flow rate of the lactose solution decreased the conversion efficiency of lactose at different input lactose concentrations. Continuous operation of 11 days was conducted to investigate the stability of a long-term operation. The retained activity of the immobilized enzymes was 63% and the half-life of the immobilized enzyme was found to be 15 days.

A study on vulnerability analysis and incident response methodology based on the penetration test of the power plant's main control systems (발전소 주제어시스템 모의해킹을 통한 취약점 분석 및 침해사고 대응기법 연구)

  • Ko, Ho-Jun;Kim, Huy-Kang
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.24 no.2
    • /
    • pp.295-310
    • /
    • 2014
  • DCS (Distributed Control System), the main control system of power plants, is an automated system for enhancing operational efficiency by monitoring, tuning and real-time operation. DCS is becoming more intelligent and open systems as Information technology are evolving. In addition, there are a large amount of investment to enable proactive facility management, maintenance and risk management through the predictive diagnostics. However, new upcoming weaponized malware, such as Stuxnet designed for disrupting industrial control system(ICS), become new threat to the main control system of the power plant. Even though these systems are not connected with any other outside network. The main control systems used in the power plant usually have been used for more than 10 years. Also, this system requires the extremely high availability (rapid recovery and low failure frequency). Therefore, installing updates including security patches is not easy. Even more, in some cases, installing security updates can break the warranty by the vendor's policy. If DCS is exposed a potential vulnerability, serious concerns are to be expected. In this paper, we conduct the penetration test by using NESSUS, a general-purpose vulnerability scanner under the simulated environment configured with the Ovation version 1.5. From this result, we suggest a log analysis method to detect the security infringement and react the incident effectively.

Configuration of Fuel Cell Power Generation System through Power Conversion Device Design (전력변환장치 설계를 통한 연료전지 발전시스템 구성)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.6
    • /
    • pp.129-134
    • /
    • 2021
  • Recently, the demand for electricity is gradually increasing due to the rapid industrial development and the improvement of living standards. In the case of Korea, which is highly dependent on fossil fuels due to such a surge in electricity demand, reduction and freezing of greenhouse gas emissions due to international environmental regulations will immediately lead to a contraction in industrial activities. Accordingly, there are many difficulties in competition with advanced countries that want to link the environment with the country's industrial production activities, and the development of alternative energy as a countermeasure is of great interest around the world. Among these new power generation methods, small-scale power generation facilities with relatively small capacity include photovoltaic generation, wind power generation, and fuel cell generation. Among them, the fuel cell attracts the most attention in consideration of continuous operation, high power generation efficiency, and long-term durability, which are important factors for practical use. Therefore, in this paper, the fuel cell power generation system was researched and constructed by designing the power conversion circuit necessary to finally obtain the AC power used in our daily life by using the DC power generated from the fuel cell as an input.