• Title/Summary/Keyword: 장기양수시험

Search Result 24, Processing Time 0.026 seconds

A Study on the Seawater Filtration Characteristics of Single and Dual-filter Layer Well by Field Test (현장실증시험에 의한 단일 및 이중필터층 우물의 해수 여과 특성 연구)

  • Song, Jae-Yong;Lee, Sang-Moo;Kang, Byeong-Cheon;Lee, Geun-Chun;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.29 no.1
    • /
    • pp.51-68
    • /
    • 2019
  • This study performs to evaluate adaptability of seashore filtering type seawater-intake which adapts dua1 filter well alternative for direct seawater-intake. This study varies filter condition of seashore free surface aquifer which is composed of sand layer then installs real size dual filter well and single filter well to evaluate water permeability and proper pumping amount according to filter condition. According to result of step aquifer test, it is analysed that 110.3% synergy effect of water permeability coefficient is happened compare to single filter since dual filter well has better improvement. dual filter has higher water permeability coefficient compare to same pumping amount, this means dual filter has more improved water permeability than single filter. According to analysis result of continuous aquifer test, it is evaluated that dual filter well (SD1200) has higher water permeability than single filter well (SS800) by analysis of water permeability coefficient using monitoring well and gauging well, it is also analysed dual filter has 110.7% synergy effect of water permeability coefficient. As a evaluation result of pumping amount according to analysis of water level dropping rate, it is analysed that dual filter well increased 122.8% pumping amount compare to single filter well when water level dropping is 2.0 m. As a result of calculating proper pumping amount using water level dropping rate, it is analysed that dual filter well shows 136.0% higher pumping amount compare to single filter well. It is evaluated that proper pumping amount has 122.8~160% improvement compare to single filter, pumping amount improvement rate is 139.6% compare to averaged single filter. In other words, about 40% water intake efficiency can be improved by just installation of dual filter compare to normal well. Proper pumping amount of dual filter well using inflection point is 2843.3 L/min and it is evaluated that daily seawater intake amount is about $4,100m^3/day$ (${\fallingdotseq}4094.3m^3/day$) in one hole of dual filter well. Since it is possible to intake plenty of water in one hole, higher adaptability is anticipated. In case of intaking seawater using dual filter well, no worries regarding damages on facilities caused by natural disaster such as severe weather or typhoon, improvement of pollution is anticipated due to seashore sand layer acts like filter. Therefore, It can be alternative of environmental issue for existing seawater intake technique, can save maintenance expenses related to installation fee or damages and has excellent adaptability in economic aspect. The result of this study will be utilized as a basic data of site demonstration test for adaptation of riverside filtered water of upcoming dual filter well and this study is also anticipated to present standard of well design and construction related to riverside filter and seashore filter technique.

Detection of Groundwater Table Changes in Alluvium Using Electrical Resistivity Monitoring Method (전기비저항 모니터링 방법을 이용한 충적층 지하수위 변동 감지)

  • 김형수
    • The Journal of Engineering Geology
    • /
    • v.7 no.2
    • /
    • pp.139-149
    • /
    • 1997
  • Electrical resistivity monitoring methods were adopted to detect groundwater table change in alluvium. Numerical modelling test using finite element method(FEM) and field resisfivity monitoring were conducted in the study. The field monitoring data were acquired in the alluvium deposit site in Jeong-Dong Ri, Geum River where pumping test had been conducted continuously for 20 days to make artificial changes of groundwater table. The unit distance of the electrode array was 4m and 21 fixed electrodes were applied in numerical calculation and field data acquisition. "Modified Wenner" and dipole-dipole array configurations were used in the study. The models used in two-dimensional numerical test were designed on the basis of the simplifving geological model of the alluvium in Jeong Dong Ri, Geum River. Numerical test results show that the apparent resistivity pseudosections were changed in the vicinity of the pootion where groundwater table was changed. Furthermore, there are some apparent resistivity changes in the boundary between aquifer and crystalline basement rock which overlays the aquifer. The field monitoring data also give similar results which were observed in numerical tests. From the numerical test using FEM and field resistivity monitoring observations in alluvium site of Geum River, the electrical monitoring method is proved to be a useful tool for detecting groundwater behavior including groundwater table change. There are some limitations, however, in the application of the resistivity method only because the change of groundwater table does not give enough variations in the apparent resistivity pseudosections to estimate the amount of groundwater table change. For the improved detection of groundwater table changes, it is desirable to combine the resistivity method with other geophysical methods that reveal the underground image such as high-resolution seismic and/or ground penetrating radar surveys.

  • PDF

The Study of Water Availability Increments by Estuary Lake in YoungSan River (영산강하구둑에 의한 수리권 가용수량 증가에 관한 고찰 고찰)

  • Park, Hee-Seong;Choi, Hyun-Gun;Kim, Chang-Shik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.2079-2083
    • /
    • 2007
  • 하구둑은 해수의 역류에 의한 염수침입을 방지하고 유역에 필요한 담수를 확보하기위하여 건설되며, 하구둑에 의하여 하천의 하구에 담수호가 생성된다. 하구담수호에 의해 기존에 염해로 취수할 수 없었던 하천구간에서의 취수가 가능하게 되며, 하구담수호를 일정한 수위로 관리함으로써 상당량의 농업용수를 확보할 수 있다. 이와 관련하여 하구담수호에 의하여 확보되는 수자원량에 대해 설계 당시의 분석 자료들이 있기는 하지만, 대부분 연 총량의 형태로 나타나 있으며, 수리권과 관련하여 하구둑에 의하여 추가적으로 확보되는 수리권 가용수량이 얼마인지에 대한 분석은 거의 없다. 그것은 하구둑의 방류량이 댐의 방류량과는 달라서 조석의 영향을 매우 크게 받기 때문에 단순한 물수지 분석으로 이를 모의하기 힘들기 때문이다. 게다가 1일 2회의 조석이 발생하므로 1일단위의 물수지 분석은 어려운 현실이다. 그럼에도 불구하고 하구둑에서 많은 양의 농업용수 취수가 이루어지고 있다. 과연 얼마정도의 양이 수리권으로서의 역할을 할 수 있는지 모르고 임의적인 허가가 계속 부여될 경우, 갈수 시 용수공급의 안정성을 확보할 수 없게 될 것이다. 따라서 안정적인 용수의 공급을 위한 적절한 수리권 가용수량에 대한 추정 필요하다. 이에 본 연구에서는 영산강하구둑의 실시간 운영을 위하여 고 등(2004)이 개발한 "영산강하구 둑 물관리 프로그램"의 기본적인 조위의 예측과 배수갑문의 방류량 산정기법 등과 수자원장기종 합계획(2006) 수립 시에 사용된 장기간의 일자연유량을 이용하여 하구둑의 수리권 가용수량 추정 모형을 개발하고, 이를 영산강 하구둑에 의해 생성된 영산호에 적용함으로써 영산호에 의해 증가되는 수리권 가용수량에 대해 고찰하여 보았다., 그리고 T-P $77.7{\sim}96.6%$(평균 94.3%)로 산정되었다. 이러한 결과는 대청호로 유입하는 유기물과 영양염류 연간 부하량의 80% 이상이 강우-유출과 함께 유입하는 것을 의미하며, 저수지 수질관리를 위해서는 유역차원의 비점오염원 관리가 시급함을 시사한다.하기 위해, 수렴흐름 추적자시험에 의한 종분산지수와 시험대수층의 평균선형유속을 이용하여 종분산계수를 구하였다. 현장에서 수행된 양수시험에 의한 평균선형유속 22.44 m/day와 평균 종분산지수 0.4155 m를 적용하여 산정된 종분산계수는 $9.32\;m^2/day$이었다. 따라서, 시험부지 내 충적층에서 일정한 양수율$(2,500\;m^3/day)$로 지하수를 개발할 시에 양수정 주변지역으로 유입되는 염소이온의 확산면적은 1일 $9.32\;m^2$ 정도일 것으로 나타났다.적인 $OH{\cdot}$ 의 생성은 ascorbate가 조직손상에 관여할 가능성을 시사하였다.었다. 정확한 예측치를 얻기 위하여 불균질 조직이 조사야에 포함되는 경우 보정이 요구되며, 골반의 경우 골 조직의 보정이 중요한 요인임을 알 수 있었다. 이를 위하여 불균질 조직에 대한 정확한 정보가 요구되며, 이는 CT 영상을 이용하는 것이 크게 도움이 되리라 생각된다.전시 슬러지층과 상등액의 온도차를 측정하여 대사열량의 발생량을 측정하고 슬러지의 활성을 측정할 수 있는 방법을 개발하였다.enin과 Rhaponticin의 작용(作用)에 의(依)한 것이며, 이는 한의학(韓醫學) 방제(方劑) 원리(原理)인 군신좌사(君臣佐使) 이론(理論)에서 군약(君藥)이 주증(主症)에 주(

  • PDF

A time rivers outflow interpreting according to an agriculture reservoir operation (농업용저수지 운영에 따른 시기별 하천유출 해석)

  • Oh, Seung-Tae;Kim, Jin-Taek
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.173-177
    • /
    • 2007
  • 현재 농업용수 이용량은 158억$m^3/yr$로 우리나라 전체 수자원이용량의 48%에 해당되며 하천유지수량을 제외하였을 경우 61%에 해당된다. 농업용수의 이용은 노후화된 농업수리시설과 관리기술 부족 등의 원인으로 이용효율이 낮은 것으로 추정되고 있다. 그러나 이러한 현황을 뒷받침해 줄 측정 및 조사자료가 부족한 실정이다. 농업용수의 물관리 연구는 장기간의 신뢰성 있는 수문자료의 획득이 절대적으로 필요하고 실제 현장에서의 물관리 상황을 조사파악하는 것이 중요한다. 이러한 자료의 축척은 체계적이고 일관되게 수행되어야 한다. 이를 위하여 한국농촌공사에서는 2000년에 경기도 용인에 위치한 이동저수지 유역을 종합시험지구로 선정하여 운영하게 되었다. 이동시험지구는 경기도 용인시, 평택시, 안성시, 사이에 위치한 전형적인 농촌지역이다. 저수지와 양수장 시설이 복합적으로 운영되어 농업용수를 공급하는 지구로 농업용수의 물관리 연구 수행을 위해 적합한 지역이다. 이동시험지구에 강우계, 저수지 수위계, 하천 수위계, 수로 수위계를 설치하여 운영하고 있으며 정기적으로 유지 관리 및 자료수집을 함으로써 신뢰성 있는 농촌지역 수문자료를 축척하고 있다. 이동시험지구의 운영은 농업용수 물관리와 관련된 체계적이고 신뢰성 있는 장기간의 수문자료를 축척하고 축척된 현장 자료의 분석을 통해 물관리 기초자료를 계량화 하는데 그 목적이 있다. 본 연구의 목적은 실제 농업용 저수지의 용수공급 운영에 따라 하천에서의 유출특성에 대한 조사를 통하여, 농업용저수지가 하천에 미치는 영향을 파악하고자 한다. 시험지구 덕성교 하천수위관측지점의 하천유출율은 65 %, 재인교 하천수위관측지점의 경우 하천유출율은 60 %를 나타내었다. 이동유역의 경우 상류에 저수지가 있으며 저수지의 시기별 저수상태와 강우량에 따라 유출에 영향을 받고 있다. 1월에 상류 저수지의 저수상태가 만수를 유지하고 있었으며 예년에 비하여 많은 강우가 발생하여 저수위 조절 차원에서 인위적으로 방류한 양이 많았기 때문으로 추정할 수 있다. 두 지점의 1월 유출이 100 % 이상인 것은 동절기 하천 결빙으로 인한 유량파악이 힘든 것으로 나타났다. 1월의 하천수위는 계측기에 기록된 수위값으로 유량을 산정한 것이다. 3월, 10월, 12월의 유출이 많은 것은 전월말 발생한 강우의 영향으로 크게 나타났다.

  • PDF

Cause of Groundwater Yield Reduction in a Collector Well Considering Sediment's Composition and Hydrogeochemical Characteristics (지층 및 이화학 특성을 고려한 방사형 집수정의 취수량 감소 원인 분석)

  • Kim, Gyoo-Bum;Lee, Chi-Hyung;Oh, Dong-Hwan
    • The Journal of Engineering Geology
    • /
    • v.27 no.4
    • /
    • pp.439-449
    • /
    • 2017
  • The cause of yield reduction in a collector well, which is located in Anseong-cheon watershed in Kyunggi province, is studied by using aquifer sediments' composition and hydraulic conductivity near four horizontal wells, no. 1, no. 4, no. 6, and no. 7 wells. During test-pumping periods, groundwater yield is reduced with a trend of $12.4m^3/d/d$ at no. 1, $2.3m^3/d/d$ at no. 4, $24.4m^3/d/d$ at no. 6, and $187.3m^3/d/d$ at no. 7 and no. 7 well shows the biggest reduction. The sediments along no. 7 horizontal well have low hydraulic conductivity and high coefficient of uniformity ($C_u$), and a deviation of $C_u$ along the well is also large. This characteristics can bring the fine particles' movement and make the openings filled. Additionally, high iron ($Fe^{2+}$) content results in a precipitation of iron hydroxides during pumping or injection and they can produce a clogging in sediments. In the future study, the analysis of physical and hydrochemical changes through a long-term pumping procedure will give a more exact interpretation for the cause of yield reduction.

농업용수 시험지구 운영을 통한 용수이용 효율성 제고

  • 김진택
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2002.02a
    • /
    • pp.309-324
    • /
    • 2002
  • 국내의 경우 관개용수의 대부분은 벼생육을 위한 논의 관개응수로 사용되고있다. 농업용수 이용은 약 150억㎥/year, 이는 하천유지수량을 제외한 전체 물이용량 237억㎥/year의 약 63%에 해당한다. 최근 물절약은 가장 중요한 사회, 경제적인 이슈 중의 하나로 인식되고 있다. 그러나, 국내의 경우 관개효율은 여전히 낮아 약 35%의 관개용수가 손실되는 것으로 추정되고있다. 비록 관개에서의 물절약이 시급한 문제이기는 하지만 용수손실 원인에 따른 손실량에 대한 정량적인 연구가 행해지지 않았었다. 손실 원인에 따른 손실량을 계측하기 위한 시험지구로 경기 평택의 이동지구를 선정하였다. 시험지구의 주수원공으로는 유역면적 9,440ha, 관개면적 2,027ha인 이동저수지이며 상류유역에 미산 및 용덕저수지가 위치하고 관개지구내에 원암 및 은산양수장이 있다. 시험지구의 계측시설은 강우량 계측을 위하여 자기강우계를 설치하였고 저수위, 하천수위 및 응배수로의 수위 측정을 위하여 수위계를 설치하였다. 강우계는 4개소에 설치되었으며 수위계는 26개소에 설치되었다 강우계는 지구내의 저수지 및 양수장 관리사 부근 4개소에 전도형 자기우량계를 설치하였다. 수위계 26개소 중에서 저수지의 저수위 계측지점이 3개소이며 하천수위 계측지점이 2개소 그리고 용배수로의 간선수로 시점부와 간지선 분기점 등의 주요지점에 21개소의 계측지점이 있다. 모든 계측지점의 계측기에는 자체 혹은 별도의 자료저장용 데이터로거가 부착되어 현장 계측자료를 저장하도록 설치 되어있다. 강우계는 전도형강우계(tipping bucket type)이며 수위계는 계측지점의 특징에 따라 여러종류의 수위계측기가 설치되었다 예를들어 초음파수위계(ultrasonic-wave type), 부표식수위계(float type) 그리고 압력식수위계(Pressure type)가 설치되어 있다. 현장 계측기의 전원은 한국전력 전원 혹은 태양전지 및 축전지를 사용하였다. 수위계측지점의 유량을 환산하기 위하여 계측지점의 단면조사와 유속측정을 통해서 수위-유량관계(rating curve)를 규명하였다. 시험지구의 관개효율 및 용수손실 규명 등에 관한 기본자료를 수집하기 위해서는 계측시스템의 운영은 장기간으로 지속 되어야 한다

  • PDF

Analysis of groundwater level change using groundwater monitoring network in Miryang area. (지하수관측망을 이용한 밀양지역의 지하수 변화 분석)

  • Baek, Mi Kyung;Sim, Gyu Sung;Kim, Sang Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.221-221
    • /
    • 2019
  • 기후변화로 인한 가뭄대비가 상시체제가 된 요즈음, 농업용수의 안정적인 공급을 위하여 가뭄 등의 비상시 지표수는 물론이고 지하수의 공급 가능량에 대해서도 국가적 관리가 필요한 실정이다. 지하수관리를 위해 국가 최상위 계획인'지하수관리기본계획(2012~2021)'이 수립되었고, 지하수의 장기적인 수량, 수질 관리를 위해 국가지하수관측망, 지역지하수관측망(보조지하수관측망), 수질측정망, 해수침투관측망 등 광역과 지역단위로 크게 나누어 지하수관측이 이루어지고 있다. 국가지하수관측망은 지하수법에 의거하여 전국의 주요지점(2016년 말 기준 412개소)에 관측소를 설치하여 수위 및 수질의 변동실태를 광역적으로 분석함이 목적이며, 보조지하수관측망은 국가지하수관측망과 연계하고 보완하기 위한 기능으로서, 지역별 주요 관측지점의 수위, 수질자료를 획득하며, 2018년 9월 현재 3,429개소가 설치되어있다. 본 연구에서는 지역지하수 관측망 중 경남밀양지역에 설치된 관측정 31개소에 대해 수위와 수질을 장기 분석하였다. 밀양지역의 보조지하수관측망 설치는 지하수관리계획의 하부계획인'경상남도 지하수관리계획(2015~2025)'에 의거 2012년에 6개소의 관측공이 설치를 시작으로, 2013년 7개소, 2014년 10개소, 2015년 8개소를 설치하여 총 31개소의 설치를 완료하였고, 2016년부터 2019년 현재까지 전체 관측정 31개소에 대하여 관측 운영 중이다. 본 연구에서는 2013년 1월~2019년 1월까지 지역의 누적강수량과 지하수위 및 수질변화를 관측하였다. 전 관측정에 대해 수위(GL.m), 수질(온도, EC)은 1시간 주기로 관측하였으며, 연 2회 생활용수 기준(19항목)의 수질검사를 실시하고, 지하수성분의 지질학적 기원분석을 위한 양음이온 분석을 연 1회 실시하였다. 관측정의 양수능력 변화관측을 위해 대수성 시험을 연 1회 실시하였고, 관측정의 특성상 장기간 미사용 관정이므로 최적의 상태유지를 위해 연1회 공내세척을 실시하였다. 또한, 관측정의 지형별 차이를 분석하기 위해 관측정의 설치위치를 산악, 강변, 기타 지역으로 구분하고, 각각의 대표관정에 대해 지형에 의한 서로 다른 영향을 분석하였고, 관측정의 심도별 변화를 알기위해 동일지역에 충적, 안반 관측정을 따로 설치하고 관측하여 지표수와 지하수의 심도별 영향의 차이를 분석하였다. 동일지역의 관측결과 평균 5m이하의 수위변화를 보이나, 5m 이상의 수위변동을 보이는 관측망은 15년 14개소 17년 19개소로 증가추세를 보이며, 이는 주로 밀집된 시설하우스 단지의 수막재배를 위한 겨울철 지하수 사용량 증가가 원인인 것으로 판단된다. 밀양지역은 강변지역에 밀집된 시설하우스단지의 동절기 수막재배를 위한 지하수 과다사용으로 수위급감 및 수량부족현상이 반복되고 있어, 예방과 대책강구를 위해 지표수의 함양과 지하수사용량의 상관관계 분석과 자료축적 및 추가연구를 위한 장기관측이 요구된다.

  • PDF

An Integrated Surface Water-Groundwater Modeling by Using Fully Combined SWAT MODFLOW Model (완전연동형 SWAT-MODFLOW 모형을 이용한 지표수-지하수 통합 유출모의)

  • Kim, Nam Won;Chung, Il Moon;Won, Yoo Seung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5B
    • /
    • pp.481-488
    • /
    • 2006
  • This paper suggests a novel approach of integrating the quasi-distributed watershed model SWAT with the fully-distributed groundwater model MODFLOW. Since the SWAT model has semi distributed features, its groundwater components hardly considers distributed parameters such as hydraulic conductivity and storage coefficient. Generating a detailed representation of groundwater recharge, head distribution and pumping rate is equally difficult. To solve these problems, the method of exchanging the characteristics of the hydrologic response units (HRUs) in SWAT with cells in MODFLOW by fully combined manner is proposed. The linkage is completed by considering the interaction between the stream network and the aquifer to reflect boundary flow. This approach is provisionally applied to Gyungancheon basin in Korea. The application demonstrates a combined model which enables an interaction between saturated zones and channel reaches. This interaction plays an essential role in the runoff generation in the Gyungancheon basin. The comprehensive results show a wide applicability of the model which represents the temporal-spatial groundwater head distribution and recharge.

Preliminary Assessment of Groundwater Artificial Recharge Effect Using a Numerical Model at a Small Basin (수치모델을 이용한 소분지에서의 지하수 인공함양 효과 예비 평가)

  • Choi, Myoung-Rak;Cha, Jang-Hwan;Kim, Gyoo-Bum
    • The Journal of Engineering Geology
    • /
    • v.30 no.3
    • /
    • pp.269-278
    • /
    • 2020
  • In this study, the effects of groundwater artificial recharge through vertical wells in the upper small basin are preliminarily evaluated by using field injection test and a 3-D numerical model. The injection rate per well in a model is set to 20, 37.5, 60, and 75 ㎥/day based on the results of field injection test, groundwater levels, and hydraulic conductivities estimated from particle size analysis, and a numerical model using MODFLOW is conducted for 28 cases, which have diverse injection intervals, in order to estimated the changes of groundwater level and water balance after injection. Groundwater level after injection does not show a linear relationship with the injection rate per well, and the cumulative effect of artificial recharge decreases and the timing of maximum water level rise is shortened as the injection interval becomes longer. In four cases of continuous injection with total injection rate of 1,200 ㎥, it is revealed that the recharge effect is analyzed as 36.5~65.3% of the original injection rate. However, it will be more effective if the artificial recharge system combined with underground barrier is introduced for the longer pumping during a long and severe drought. Additionally, it will be possible to build a stable artificial recharge system by an establishment of efficient scenario from recharge to pumping as well as an optimization of recharge facilities.

Effluent Characteristics of Nonpoint Source Pollutant Loads at Paddy Fields during Cropping Period (영농기 광역논으로부터 비점오염물질 유출 특성)

  • Han, Kuk-Heon;Kim, Jin-Ho;Yoon, Kwang-Sik;Cho, Jae-Young;Kim, Won-Il;Yun, Sun-Gang;Lee, Jeong-Taek
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.40 no.1
    • /
    • pp.18-24
    • /
    • 2007
  • Paddy fields are apparently nonpoint source pollution and influence water environment. In order to improve water quality in rivers or lakes, to low nutrient load from paddy fields are required. To establish comprehensive plan to control agricultural non-point source pollution, it is imperative to get a quantitative evaluation on pollutants and pollution load from paddy fields. A field monitoring study was carried out to investigate the water balance and losses of nutrients from fields in Sumjin river basin. The size of paddy fields was 115 ha and the fields were irrigated from a pumping station. The observed total nitrogen loads from paddy fields were larger than those of the unit loads determined by Ministry of Environment data (MOE). It is because the nitrogen fertilization level at the studied field was higher than the recommended rate and the high irrigation and subsequent drainage amount. On the contrary, total phosphorus loads were less than those addressed by MOE since phosphorus fertilization level was lower than that of standard level. Therefore, it was found that fertilization, irrigation, and drainage management are key factors to determine nutrient losses from paddy fields. When the runoff losses of nutrients were compared to applied chemical fertilizer, it was found that 42 to 60% of nitrogen lost via runoff while runoff losses of phosphorus account for 1.3 to 7.6% of the total applied amount during the entire year.