• Title/Summary/Keyword: 장검

Search Result 8, Processing Time 0.025 seconds

Identification and Removal of Pigments in Blood-colored Grooves of Long Sword, Admiral Yi Sun-sin (Treasure No. 326) (보물 제326호 이순신 장검 혈조 내 안료의 규명 및 제거)

  • Kwon, Hyuk Nam;Youn, Hye Seong;Ryu, Dong Wan;Lee, Jeong Won;Lee, Jang Jon;Han, Min Soo
    • Journal of Conservation Science
    • /
    • v.31 no.4
    • /
    • pp.499-506
    • /
    • 2015
  • The artifacts of Admiral Yi Sun-sin (Treasure No.326) consist of six items with two long swords, a jade decoration, a belt and two peach-shaped cups. In commemoration of the opening of Chungmugong Yi sun-sin Memorial Museum (April 28, 2011), there were conservation treatments for those artifacts at the beginning of 2011. At that time, from the result of non-destructive surface analysis on pigments in blood-colored grooves of the two long swords, it was presumed to be synthetic resin paints. This study shows the accurate identification on pigments which was presumed as synthetic resin paints and its removal. To identify pigments in blood-colored grooves, the optical microscope, scanning electron microscope, Micro-XRF, XRD and FT-IR were used for the analysis. The results turned out that the thickness of $10{\sim}90{\mu}m$ in a single layer was measured. And major components containing Pb and Cr and lead chromium molybdenum oxide were identified and to identify components of adhesives from the analysis by FT-IR, it turned out to be alkyd resin, which can be presumed that they were recently colored with synthetic paints. The synthetic paints easily react with most of the organic solvents. And it is so easy to handle without the effect on metal that it was removed with acetone. While removing synthetic paints, all of paints on it were collected for identifying whether there is traditional pigment but nothing was identified.

Development of Remote Reld Testing Technique for Moisture Separator & Reheater Tubes in Nuclear Power Plants (원자력발전소 습분분리재열기 튜브 원격장검사 기술 개발)

  • Nam, Min-Woo;Lee, Hee-Jong;Kim, Cheol-Gi
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.4
    • /
    • pp.339-345
    • /
    • 2008
  • The heat exchanger tube in nuclear power plants is mainly fabricated from nonferromagnetic material such as a copper, titanium, and inconel alloy, but the moisture separator & reheater tube in the turbine system is fabricated from ferromagnetic material such as a carbon steel or ferrite stainless steel which has a good mechanical properties in harsh environments of high pressure and temperature. Especially, the moisture separator & reheater tubes, which use steam as a heat transfer media, typically employ a tubing with integral fins to furnish higher heat transfer rates. The ferromagnetic tube typically shows superior properties in high pressure and temperature environments than a nonferromagnetic material, but can make a trouble during the normal operation of power plants because the ferrous tube has service-induced damage forms including a steam cutting, erosion, mechanical wear, stress corrosion cracking, etc. Therefore, nondestructive examination is periodically performed to evaluate the tube integrity. Now, the remote field testing(RFT) technique is one of the solution for examination of ferromagnetic tube because the conventional eddy current technique typically can not be applied to ferromagnetic tube such as a ferrite stainless steel due to the high electrical permeability of ferrous tube. In this study, we have designed RFT probes, calibration standards, artificial flaw specimen, and probe pusher-puller necessary for field application, and have successfully carry out RFT examination of the moisture separator & reheater tube of nuclear power plants.

Conservation of Chungmugong's Artifacts (보물 제326호 이충무공유물의 과학적 보존)

  • Kwon, Hyuk Nam;Seo, Jung Eun;Ha, Eun Ha;Lee, Han Hyoung;Lee, Eun Woo
    • Korean Journal of Heritage: History & Science
    • /
    • v.44 no.3
    • /
    • pp.62-77
    • /
    • 2011
  • Yi Sunsin's artifacts had been exhibited at Hyeonchungsa in Asan-si, Chungchungnam-do. These artifacts include Janggeom(Long swords), Okno(Jade ornament of Korea traditional hat), Yodae(Waist belt) and Dobae(Peach shaped wine cups) Gudae(Yodae's saucers). These were covered with dust and corroded due to long term display. Condition of these artifacts was examined for a re-opening of Yi Chungmugong Memorial Pavilion on 28 March 2011. Before conservation treatment of the artifacts, scientific analysis was conducted to identify the material of the artifacts. The result showed that the red paint on the hilt of the sword is composed of two layers. Pigments of two layers were found to be hematite and cinnabar mixed with red lead respectively. Mixed layer was assumed to have been applied recently. Also it was found that the blade of the sword was repainted using chrome yellow($PbCrO_4$). Considering the time limit, conservation treatment focused on stabilization of damaged area and prevention of futher risk during display.

A Study on the Securing Political Neutrality of the Prosecution Service (검찰의 정치적 중립성 확보방안 연구)

  • Kim, Taek;Jung, In whan
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.59-66
    • /
    • 2020
  • This paper considered the measures of securing political neutrality of the prosecutor on the reform of the prosecution. The nation's prosecution has enormous authority. In the meantime, the prosecution enjoyed unlimited power uncontrolled with investigative rights, prosecution monopoly, and police investigation command. No other country has as much power as the Korean prosecution. However, the prosecution, which enjoys such power, is placed on the task of reforming the prosecution due to poor democratic control. Has there been such a prosecutor in Korean history who only looks forward and wields long sword ehrflqtjdrhk against corruption in power? So far, the prosecution has conducted investigations that suit the administration's taste, and the prosecutors have been on the rise in return. That is why the previous administrations tried to ensure the political neutrality of the prosecution. As such, We would like to consider legal logic to analyze the sincerity of the prosecution reform. To this end, the first is to consider the authority of prosecutors and prosecutors. Second, consider the internal requirements of the government's reform of the prosecution. Third, establish the direction of prosecution reform.

Development of a Multichannel Eddy Current Testing Instrument(II) (다중채널 와전류탐상검사 장치 개발(II))

  • Lee, Hee-Jong;Nam, Min-Woo;Cho, Chan-Hee;Yoo, Hyun-Joo;Kim, In-Chel
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.552-559
    • /
    • 2011
  • Recently, the eddy current testing(ECT), alternating current field testing, magnetic flux leakage testing and remote field testing have been used as a nondestructive evaluation method based on the electromagnetic induction phenomenon. The eddy current testing is now widely accepted as a NDE method for the heat exchanger tube in the electric power industry, chemical, shipbuilding, and military. The ECT system mainly consists of the synthesizer module, analog module, analog-to-digital converter, power supplier, and data acquisition and analysis program. In the previous study, the synthesizer module and the analog module which is essential to the ECT system were primarily developed, and in this study the data acquisition and analysis program were developed. The operation system for this program is based on the Windows 7, and optimized for the Korean users, and the specific feature of this program using setup wizard enables inspector to make a setup easily for acquisition and analysis of ECT data. In this paper, the configuration and functions of eddy current data acquisition and analysis program will be introduced.

Development of a Multichannel Eddy Current Testing Instrument(I) (다중채널 와전류탐상검사 장치 개발(I))

  • Lee, Hee-Jong;Nam, Min-Woo;Cho, Chan-Hee;Yoon, Byung-Sik;Cho, Hyun-Joon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.2
    • /
    • pp.155-161
    • /
    • 2010
  • Recently, the electromagnetic techniques of the eddy current testing(ECT), alternating current field testing, magnetic flux leakage testing and remote field testing have been used as a nondestructive evaluation method based on the electromagnetic induction. The eddy current testing is now widely accepted as a NDE method for the heat exchanger tube in the electric power industry, chemical, shipbuilding, and military. The ECT system mainly consists of the synthesizer module, analog module, analog-to-digital converter, power supplier, and data acquisition and analysis program. In this study, the synthesizer module and the analog module which are essential to the ECT system were primarily developed. The developed ECT system is basically a multifrequency type which is able to inject the maximum four frequencies based on the frequency and time domain multiplexing method. Conclusively, we confirmed that the EC signal was processed appropriately in each circuit modules, and the Lissajous EC signal was displayed in the impedance plane.

The Effect of Cyclic Load on Different Femoral Fixation Techniques in Anterior Cruciate Ligament Reconstruction (전방십자인대 재건시 이식건의 대퇴골측 고정에 대한 주기성인장부하의 효과)

  • Song Eun-Kyoo;Kim Jong Seok
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.1
    • /
    • pp.28-36
    • /
    • 2003
  • Purpose: To determine and to compare the effects of cyclic loading on the fixation strength of different femoral fixation methods in ACL reconstruction. Materials and Methods: Biomechanical test using an Instron(R) machine (Model No.5569. Mass, U.S.A) were carried out to compare the pull out strength of six different femoral fixation techniques after a cyclic loading in 72 Yorkshire pig knees. The graft-bone complex was cyclically loaded between 30N and 150N at 50 mm/min rate for 1000 cycles and maximal tensile testing was performed. A preload of 30N was applied to the graft along the axis of the tunnel 15 minutes. ANOVA and the Duncan multiple comparison test was used for the statistical analysis. Results: The mean maximum tensile strength of femoral fixation before and after the cyclic loading test were 1003.4$\pm$145N and 601.1$\pm$154N in hamstring-LA screw(R) group, 595.5$\pm$104N and 360.7$\pm$56N in hamstring-Bioscrew(R) group, 1431.7$\pm$135N and 710.7$\pm$114N in hamstring-Semifix(R) group, 603.6$\pm$54N and 459.1$\pm$46N in hamstring-Endobutton(R) fixation group, 1067.4$\pm$145 and 601.8$\pm$134N in the BPTB-Titanium interference screw group, and 987.1$\pm$168N and 588.7$\pm$124N in the BPTB-Bioscrew(R) group. And these data illustrated that cyclic loading reduces the maximum tensile strength by 40 $\%$, 39 $\%$, 50 $\%$, 24 $\%$, 44 $\%$, 40 $\%$ respectively. Conclusions: With the results of these experiments it should be emphasized that rehabilitation exercises after anterior cruciate ligament reconstruction should be executed with precaution as the repetitive flexion and extension of the knee would compromise the maximum tensile strength of the graft tendon.

  • PDF

Operative treatment for Proximal Humeral Fracture (상완골 근위부 골절의 수술적 요법)

  • Park Jin-Young;Park Hee-Gon
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.2
    • /
    • pp.168-175
    • /
    • 2003
  • Fracture about proximal humerus may be classified as the articular segment or the anatomical neck, the greater tuberosity, the lesser tuberosity, and the shaft or surgical neck. Now, usually used, Neer's classification is based on the number of segments displaced, over 1cm of displaced or more than 45 degrees of angulation , rather than the number of fracture line . Absolute indication of a operative treatment a open fracture, the fracture with vascular injury or nerve injury , and unreductable fracture-dislocation . Inversely, the case that are severe osteoporosis, and eldly patient who can't be operated by strong internal fixation is better than arthroplasty used by primary prosthetic replacement and early rehabilitation program than open reduction and internal fixation. The operator make a decision for the patient who should be taken the open reduction and internal fixation, because it's different that anatomical morphology, bone density, condition of patient. The operator decide operation procedure. For example, percutaneous pinning, open reduction, plate & screws, wire tension bands combined with some intramedullary device are operation procedure that operator can decide . The poor health condition for other health problem, fracture with unstable vital sign and severe osteoporosis , are the relative contraindication. The stable fracture without dislocation is not the operative indication . The radiologic film of the prokimal humerus before the operation can not predict for fracture evaluation. It's necessary to good radiologic film for evaluation of fracture form. The trauma serise is better than the other radiologic film for evaluation. The accessary radiologic exam is able to help for evaluation of bone fragment and anatomy. The CT can be helpful in evaluating these injury, especially if the extract fracture type cannot be determined from plain roenterogram of the proximal humerus, bone of humerus head. If the dislocation is severe anatomically , we could consider to do three dimentional remodelling. The MRI doing for observing of bony morphology before the operation is not better than CT If we were suspicious of vascular injury, we could consider the angiography.

  • PDF