• 제목/요약/키워드: 작동유체

검색결과 549건 처리시간 0.026초

쿠션 형상 변화에 따른 유압 액추에이터 작동 특성 연구 (Motion Characteristics of Hydraulic Actuator with Various Cushion Shapes)

  • 김진형;강현수;한수민;김윤제
    • 한국유체기계학회 논문집
    • /
    • 제18권2호
    • /
    • pp.48-53
    • /
    • 2015
  • Hydraulic actuator is a primary component of the hydraulic valve systems. This paper describes a motion characteristic of hydraulic actuator with various configurations of cushion. It plays an important role in protecting the actuator from the shock when the piston reaches the end position. Numerical analyses were conducted by using commercial code, ANSYS with k-${\varepsilon}$ turbulent model. The results for pressure and velocity distributions in the hydraulic actuator with different cushion shapes were graphically depicted.

볼 밸브 압력강하와 공동현상감소에 대한 연구 (A Study on analysis between pressure-drop and cavitation diminution with ball valve)

  • 구본찬;기준우;이도형
    • EDISON SW 활용 경진대회 논문집
    • /
    • 제2회(2013년)
    • /
    • pp.393-397
    • /
    • 2013
  • 관내의 유량을 제어하는 볼 밸브(ball valve)는 개폐각도(opening degree)가 커짐에 따라 출구에서 유속이 증가하고 밸브(valve)의 입 출구 간 압력강하(pressure drop)가 증가한다. 출구에서의 압력이 작동유체의 포화증기압보다 낮아질 때 공동현상(cavitation)이 발생한다. 관내에서의 공동현상은 배관시스템의 진동 및 소음, 부식 등에 있어서 악영향을 미칠 수 있으므로 설계에 매우 중요한 요소이다. 버터플라이 밸브를 비롯한 다른 밸브에서는 공동현상감소에 대한 연구가 많이 이루어졌다. 이에 본 연구에서는 볼 밸브 내 유동 특성(characteristic of flow)과 볼 밸브의 입출구간 압력강하를 줄이는 연구를 수행하였다. 개폐 각도와 그에 따른 압력강하와의 관계를 Edison_전산열유체를 사용하여 분석하고 공동현상을 감소시킨 볼 밸브의 설계를 제시 하였다.

  • PDF

중온 히트파이프에서 작동유체 선정에 관한 실험적 연구 (Experimental Study on the Working Fluid Selection of Medium Temperature Heat Pipe)

  • 이영수;박기호;백영진
    • 한국지열·수열에너지학회논문집
    • /
    • 제3권2호
    • /
    • pp.1-7
    • /
    • 2007
  • This paper is concerned with the selection of proper working fluids for medium temperature range heat pipe. The heat pipe which is made of SUS 316L has a total length of 700 mm as well as an outside diameter of 27.2 mm and a thickness of 2.1 mm respectively. Working fluids used in this study were Naphthalene, Biphenyl and Dowtherm A. Their charge amounts were about 40% of the inside volume of evaporator section. Experimental results shows that the Dowtherm A is good for $200^{\circ}C{\sim}300^{\circ}C$temperature range, while the Naphthalene is proper for $300^{\circ}C{\sim}430^{\circ}C$. In the case of the Naphthalene heat pipe, the heat transfer rate reaches 1500 W along with a vapor temperature of $430^{\circ}C$.

  • PDF

터보펌프의 수력 성능시험 (Hydraulic Performance Test of a Turbopump)

  • 홍순삼;김대진;김진선;최창호;김진한
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2005년도 제24회 춘계학술대회논문집
    • /
    • pp.243-247
    • /
    • 2005
  • 액체로켓엔진용 터보펌프에서 연료펌프에 대한 수력시험을 수행하였다. 작동유체는 상온의 물이며 펌프는 모터로 구동되고 상온의 물을 작동유체로 이용하였다. 인듀서가 펌프의 양정 및 효율에 미치는 영향은 작지만 펌프의 캐비테이션 성능에는 지대한 영향을 미치는 것을 실험으로 확인하였다. 또한 인듀서 단독의 성능을 살펴보기 위한 시험을 수행하였는데, 캐비테이션 시험 중 인듀서에서 $55\%$ 양정저하가 발생할 때 펌프에서 캐비테이션 임계점에 도달하는 것을 알 수 있었다.

  • PDF

엔진 배기열 이용 유기랭킨사이클에 대한 실험적 연구 (Experimental Research on an Organic Rankine Cycle Using Engine Exhaust Gas)

  • 신동길
    • 에너지공학
    • /
    • 제21권4호
    • /
    • pp.393-397
    • /
    • 2012
  • 본 연구에서는 산업용 가스 엔진의 배기 폐열을 회수하여 발전하는 유기랭킨사이클을 구성하고 시스템 성능 분석 실험을 수행하였다. 엔진 배기가스 열을 작동유체(냉매 R134a)에 흡수시키기 위해 Shell & Tube 방식 열교환기를 엔진 배기 매니폴드 후단에 장착하였다. 엔진출력 60 kW인 조건에서 약 63 kW의 배기가스 열을 배출하였으며, 열교환기를 통해 작동유체에 흡수된 열량은 43~46 kW로서 배기가스 열회수율은 68~73%, 최대출력은 4.6 kW로서 배기가스 열량에 대한 최대출력의 비는 7.3%을 나타내었다.

초소형 유기랭킨사이클용 스크롤팽창기 효율 특성 분석 (Analysis of Efficiencies of Scroll Expander for Micro Scale Organic Rankine cycle)

  • 신동길
    • 에너지공학
    • /
    • 제21권4호
    • /
    • pp.398-401
    • /
    • 2012
  • 본 연구에서는 자동차용 엔진 폐열 회수 유기랭킨사이클에 적용하기 위해 개발 중인 스크롤 팽창기의 효율을 상용 스크롤 팽창기와 비교 분석을 수행하였다. 팽창기 효율 특성 시험을 위해 유기랭킨사이클을 운전하면서 팽창기 출력, 팽창기 입구 온도, 압력 및 작동유체(냉매 R134a)의 유량을 측정하였으며, 개발 중인 스크롤 팽창기의 전효율은 상용 스크롤 팽창기의 전효율에 비해 매우 낮은 수준을 나타내었다. 특히 팽창기 내부의 작동유체 누설에 의한 체적효율 저하가 전효율 저하에 큰 영향을 주는 것으로 파악되었기 때문에 향후 팽창기 효율 향상을 위해 팽창기 내부의 누설문제를 필히 해결해야할 것으로 분석되었다.

나선 그루브형 열사이폰의 작동유체의 변화에 대한 응축열전달 성능에 관한 연구 (A Study on the Performance of Condensation Heat Transfer for Various Working Fluid of Two-Phase Closed Thermosyphons with Various Helical Grooves)

  • 한규일;조동현;박종운;이상진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.239-244
    • /
    • 2003
  • This study concerns the performance of condensing heat transfer in two-phase closed thermosyphons with various helical grooves. Distilled water, methanol, ethanol have been used as the working fluid. In the present work, a copper tube of the length of 1200mm and 14.28mm of inside diameter is used as the container of the thermosyphon. Each of the evaporator and the condenser section has a length of 550mm, while the remaining part of the thermosyphon tube is adiabatic section. A experimental study was carried out for analyzing the performances of having 50, 60, 70, 80, 90 helical grooves. A plain thermosyphon having the same inner and outer diameter as the grooved thermosyphons is also tested for the comparison. The type of working fluid and the numbers of grooves of the thermosyphons with various helical grooves have been used as the experimental parameters. The experimental results have been assessed and compared with existing theories. The results show that the type of working fluids are very important factors for the operation of thermosyphons. And the maximum enhancement (i.e. the ratio of the heat transfer coefficients the helical thermosyphons to plain thermosyphons) is $1.5{\sim}2$ for condensation.

  • PDF

2 성분 혼합물을 작동유체로 사용하는 태양열 집열기용 히트파이프의 실험적 연구 (An Experimental Study of a Heat pipe with Binary Mixture Working Fluid for Solar Collector)

  • 정의국;부준홍;정원복
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.13-18
    • /
    • 2003
  • Heat pipes with binary mixture fabricated and tested for applications where condenser temperature is in a range of $10^{\circ}C$ to $130^{\circ}C$. The pipe materials 8.0 mm O.D. cupper tube and the working fluids are ethanol-water mixtures. The total length of test of the heat pipe was 1710mm in which evaporator section was 1570mm, adiabatic section was 50mm and condenser section was 90mm. Mixing ratios of ethanol and water could be variable in mole fraction. Temperature of condenser section was $10^{\circ}C$, $80^{\circ}C$ and $130^{\circ}C$. Heat pipe performance experimental study was accomplished with change of mixing ratio in these temperatures. The fill charge ratio was 20% of the heat pipe volume. Wick structure was woven-wire and method of experimental work was that thermal load was increased 20W step until the heat pipe wall temperature reached at $150^{\circ}C$. Results were following: At coolant $10^{\circ}C$ and $130^{\circ}C$, mixing ratio that have beat thermal performance was 0.8M+ and at coolant $80^{\circ}C$, was 0.3 ${\sim}$ 0.5 M+.

  • PDF

스털링기관 재생기내의 작동유체 유속 및 마찰저항 특성(I) - 작동유체 유속 특성 - (Velocity and Flow Friction Characteristic of Working Fluid in Stirling Engine Regenerator (I) - Velocity Characteristic of Working Fluid in Stirling Engine Regenerator -)

  • 김태한;조창래
    • Journal of Biosystems Engineering
    • /
    • 제32권6호
    • /
    • pp.389-394
    • /
    • 2007
  • The power output of the stirling engine is influenced by the regenerator effectiveness. The regenerator effectiveness is influenced by heat transfer and flow friction loss of the regenerator matrix. In this paper, in order to provide basic data for the design of the regenerator matrix, characteristics of working fluid velocities were investigated by a packed method of matrix in the oscillating flow as the same condition of operation in a Stirling engine. As matrices, two different wire screens were used. The results are summarized as follows; 1. When a regenerator is not filled with any wire screen, working fluid velocity of the oscillating flow shows 1.3 times faster than that of one directional flow. 2. When a regenerator is filled with the wire screen of No.50, working fluid velocity of the oscillating flow reveals 2.5 times faster than that of one directional flow. 3. When a regenerator is filled with the wire screen of No. 100, working fluid velocity of the oscillating flow shows 2 times faster than that of one directional flow, regardless of the number of packed wire screens. 4. Working fluid velocity is decreased wire the increase in number of meshes and packed wire screens.