• Title/Summary/Keyword: 자유론

Search Result 253, Processing Time 0.02 seconds

A study of usefulness for the plan based on only MRI using ViewRay MRIdian system (ViewRay MRIdian System을 이용한 MRI only based plan의 유용성 고찰)

  • Jeon, Chang Woo;Lee, Ho Jin;An, Beom Seok;Kim, Chan young;Lee, Je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.131-143
    • /
    • 2015
  • Purpose : By comparing a CT fusion plan based on MRI with a plan based on only MRI without CT, we intended to study usefulness of a plan based on only MRI. And furthermore, we intended to realize a realtime MR-IGRT by MRI image without CT scan during the course of simulation, treatment planning, and radiation treatment. Materials and Methods : BBB CT (Brilliance Big Bore CT, 16slice, Philips), Viewray MRIdian system (Viewray, USA) were used for CT & MR simulation and Treatment plan of 11 patients (1 Head and Neck, 5 Breast, 1 Lung, 3 Liver, 1 Prostate). When scanning for treatment, Free Breathing was enacted for Head&Neck, Breast, Prostate and Inhalation Breathing Holding for Lung and Liver. Considering the difference of size between CT and Viewray, the patient's position and devices were in the same condition. Using Viewray MRIdian system, two treatment plans were established. The one was CT fusion treatment plan based on MR image. Another was MR treatment plan including electron density that [ICRU 46] recommend for Lung, Air and Bone. For Head&Neck, Breast and Prostate, IMRT was established and for Lung and Liver, Gating treatment plan was established. PTV's Homogeneity Index(HI) and Conformity Index(CI) were use to estimate the treatment plan. And DVH and dose difference of each PTV and OAR were compared to estimate the treatment plan. Results : Between the two treatment plan, each difference of PTV's HI value is 0.089% (Head&Neck), 0.26% (Breast), 0.67% (Lung), 0.2% (Liver), 0.4% (Prostate) and in case of CI, 0.043% (Head&Neck), 0.84% (Breast), 0.68% (Lung), 0.46% (Liver), 0.3% (Prostate). As showed above, it is on Head&Neck that HI and CI's difference value is smallest. Each difference of average dose on PTV is 0.07 Gy (Head&Neck), 0.29 Gy (Breast), 0.18 Gy (Lung), 0.3 Gy (Liver), 0.18 Gy (Prostate). And by percentage, it is 0.06% (Head&Neck), 0.7% (Breast), 0.29% (Lung), 0.69% (Liver), 0.44% (Prostate). Likewise, All is under 1%. In Head&Neck, average dose difference of each OAR is 0.01~0.12 Gy, 0.04~0.06 Gy in Breast, 0.01~0.21 Gy in Lung, 0.06~0.27 Gy in Liver and 0.02~0.23 Gy in Prostate. Conclusion : PTV's HI, CI dose difference on the Treatment plan using MR image is under 1% and OAR's dose difference is maximum 0.89 Gy as heterogeneous tissue increases when comparing with that fused CT image. Besides, It characterizes excellent contrast in soft tissue. So, radiation therapy using only MR image without CT scan is useful in the part like Head&Neck, partial breast and prostate cancer which has a little difference of heterogeneity.

  • PDF

The efficacy of continuous positive airway pressure (CPAP) for patient with left breast cancer (좌측 유방암 방사선치료에서 CPAP(Continuous Positive Airway Pressure)의 유용성 평가)

  • Jung, Il Hun;Ha, Jin Sook;Chang, Won Suk;Jeon, Mi Jin;Kim, Sei Joon;Jung, Jin Wook;Park, Byul Nim;Shin, Dong Bong;Lee, Ik Jae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.43-49
    • /
    • 2019
  • Purpose: This study examined changes in the position of the heat and lungs depending on the patient's breathing method during left breast cancer radiotherapy and used treatment plans to compare the resulting radiation dose. Materials and methods: The participants consisted of 10 patients with left breast cancer. A CT simulator(SIMENS SOMATOM AS, Germany) was used to obtain images when using three different breathing methods: free breathing(FB), deep inspiration breath hold(DIBH with Abches, DIBH), inspiration breath hold(IBH with CPAP, CPAP). A Ray Station(5.0.2.35, Sweden) was used for treatment planning, the treatment method was volumetric modulated arc therapy (VMAT) with one partial arc of the same angle, and the prescribed dose to the planning target volume (PTV) was a total dose of 50Gy(2Gy/day). In treatment plan analysis, the 95% dose (D95) to the PTV, the conformity index(CI), and the homogeneity index (HI) were compared. The lungs, heart, and left anterior descending artery (LAD) were selected as the organs at risk(OARs). Results: The mean volume of the ipsilateral lung for FB, DIBH, and CPAP was 1245.58±301.31㎤, 1790.09±362.43 ㎤, 1775.44±476.71 ㎤. The mean D95 for the PTV was 46.67±1.89Gy, 46.85±1.72Gy, 46.97±23.4Gy, and the mean CI and HI were 0.95±0.02, 0.96±0.02, 0.95±0.02 and 0.91±0.01, 0.90±0.01, 0.92±0.02. The V20 of Whole Lung was 10.74±4.50%, 8.29±3.14%, 9.12±3.29% and The V20 of the ipsilateral lung was 20.45±8.65%, 17.18±7.04%, 18.85±7.85%, the Dmean of the heart was 7.82±1.27Gy, 6.10±1.27Gy, 5.67±1.56Gy, and the Dmax of the LAD was 20.41±7.56Gy, 14.88±3.57Gy, 14.96±2.81Gy. The distance from the thoracic wall to the LAD was measured to be 11.33±4.70mm, 22.40±6.01mm, 20.14±6.23mm. Conclusion: During left breast cancer radiotherapy, the lung volume was 46.24% larger for DIBH than for FB, and 43.11% larger for CPAP than FB. The larger lung volume increases the distance between the thoracic wall and the heart. In this way, the LAD, which is one of the nearby OARs, can be more effectively protected while still satisfying the treatment plan. The lung volume was largest for DIBH, and the distance between the LAD and thoracic wall was also the greatest. However, when performing treatment with DIBH, the intra-fraction error cannot be ignored. Moreover, communication between the patient and the radiotherapist is also an important factor in DIBH treatment. When communication is problematic, or if the patient has difficulty holding their breath, we believe that CPAP could be used as an alternative to DIBH. In order to verify the clinical efficacy of CPAP, it will be necessary to perform long-term follow-up of a greater number of patients.

Usefulness of Gated RapidArc Radiation Therapy Patient evaluation and applied with the Amplitude mode (호흡 동조 체적 세기조절 회전 방사선치료의 유용성 평가와 진폭모드를 이용한 환자적용)

  • Kim, Sung Ki;Lim, Hhyun Sil;Kim, Wan Sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.29-35
    • /
    • 2014
  • Purpose : This study has already started commercial Gated RapidArc automation equipment which was not previously in the Gated radiation therapy can be performed simultaneously with the VMAT Gated RapidArc radiation therapy to the accuracy of the analysis to evaluate the usability, Amplitude mode applied to the patient. Materials and Methods : The analysis of the distribution of radiation dose equivalent quality solid water phantom and GafChromic film was used Film QA film analysis program using the Gamma factor (3%, 3 mm). Three-dimensional dose distribution in order to check the accuracy of Matrixx dosimetry equipment and Compass was used for dose analysis program. Periodic breathing synchronized with solid phantom signals Phantom 4D Phantom and Varian RPM was created by breathing synchronized system, free breathing and breath holding at each of the dose distribution was analyzed. In order to apply to four patients from February 2013 to August 2013 with liver cancer targets enough to get a picture of 4DCT respiratory cycle and then patients are pratice to meet patient's breathing cycle phase mode using the patient eye goggles to see the pattern of the respiratory cycle to be able to follow exactly in a while 4DCT images were acquired. Gated RapidArc treatment Amplitude mode in order to create the breathing cycle breathing performed three times, and then at intervals of 40% to 60% 5-6 seconds and breathing exercises that can not stand (Fig. 5), 40% While they are treated 60% in the interval Beam On hold your breath when you press the button in a way that was treated with semi-automatic. Results : Non-respiratory and respiratory rotational intensity modulated radiation therapy technique absolute calculation dose of using computerized treatment plan were shown a difference of less than 1%, the difference between treatment technique was also less than 1%. Gamma (3%, 3 mm) and showed 99% agreement, each organ-specific dose difference were generally greater than 95% agreement. The rotational intensity modulated radiation therapy, respiratory synchronized to the respiratory cycle created Amplitude mode and the actual patient's breathing cycle could be seen that a good agreement. Conclusion : When you are treated Non-respiratory and respiratory method between volumetric intensity modulated radiation therapy rotation of the absolute dose and dose distribution showed a very good agreement. This breathing technique tuning volumetric intensity modulated radiation therapy using a rotary moving along the thoracic or abdominal breathing can be applied to the treatment of tumors is considered. The actual treatment of patients through the goggles of the respiratory cycle to create Amplitude mode Gated RapidArc treatment equipment that does not automatically apply to the results about 5-6 seconds stopped breathing in breathing synchronized rotary volumetric intensity modulated radiation therapy facilitate could see complement.