• Title/Summary/Keyword: 자연열화

Search Result 92, Processing Time 0.031 seconds

A Study on the Relationship of Change of Mechanical Properties and Carbonyl Index Induced through Short-wavelength Ultraviolet Radiation (254 nm) for High Density Polyethylene (단파장 자외선(254 nm)에 노출된 고밀도 폴리에틸렌 수지의 카르보닐 지수(CI)와 기계적 물성 변화의 관계에 관한 연구)

  • Kim, Chang-Hwan;Shin, Jin-Yong
    • Applied Chemistry for Engineering
    • /
    • v.24 no.2
    • /
    • pp.138-143
    • /
    • 2013
  • This paper studied the possibility to predict a mechanical property variation from changes in created carbonyl bands by irradiating the surface of high-density polyethylene with short-wavelength ultraviolet radiation of 254 nm to induce a fast chemical degradation. The meaning of this study lies in checking whether a mechanical property change with the same chemical property as the induced optical deterioration is caused by using a UVC lamp with high photon energy instead of optical deterioration via xenon arc light source and outdoor exposure test via natural sunlight requiring a long time. The mechanical strength of high-density polyethylene checked by a tensile test and a creep destruction test showed a similar tendency with CI changes. In particular, the yield strength and elongation had a close relationship with the exposure time to ultraviolet radiation. Accordingly, this paper presented a method to grasp the mechanical property change outdoors requiring a long time more fast through the relationship between the mechanical property change and the carbonyl index using a UVC lamp causing the fast surface degradation.

A Study of Performance Evaluation of Warm Asphalt Binder Properties using LEADCAP(R) additive (중온화 첨가제(LEADCAP(R))를 사용한 중온 아스팔트 바인더의 특성 평가)

  • Lee, Jae-Jun;Yang, Sung-Lin;Kwon, Soo-Ahn;Hwang, Sung-Do
    • International Journal of Highway Engineering
    • /
    • v.13 no.2
    • /
    • pp.1-8
    • /
    • 2011
  • The objective of this paper is to evaluate the performance of low $CO_2$ asphalt binder properties using LEADCAP$^{(R)}$(Low Energy and Carbon Asphalt Pavement) additive as function of various aging methods such as RTFO(Rolling thin film oven), Ultraviolet(UV) lay. In order to simulate the short-term aging of asphalt binder that occurs during the hot-mixing asphalt process, the Rolling Thin Film Oven(RTFO) was used. Asphalt binder using LEADCAP$^{(R)}$ is prepared by addition of a photoinitiator activated by ultraviolet lay. The mechanical and rheological properties of the asphalt binder were estimated using UTM(Universal Testing Machine) and DSR(Dynamic Shear Rheometer). The test results showed that the asphalt binder using LEADCAP$^{(R)}$ additive was improved the rutting resistance at testing temperature ($70^{\circ}C$) and increased tensile strength at low temperature. Also, Thermal analysis shows that the Melting Point(Tm) of asphalt binder using LEADCAP$^{(R)}$ additive was constant although the asphalt binder was aged by Ultraviolet.

Corrosion Level Measurement Technique for RC Reinforcement Using Non-Destructive Test Methods (비파괴기법을 이용한 철근 콘크리트 벽체 철근의 부식률 예측기법)

  • Roh, Young-Sook
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.1
    • /
    • pp.24-31
    • /
    • 2011
  • In order to measure corrosion level of reinforcement rebar in RC structures, non-destructive test methods which are concrete surface current density method and infrared thermographic technique were employed to measure corrosion levels. Experimental test parameters were various levels of corrosion states(0, 1, 3, 5, 7% of weight loss) and concrete cover depth(30 mm, 40 mm) and two different reinforcing rebar arrangements. The larger amount of concrete surface current density, the higher corrosion level in reinforcement rebar. The laboratory conditions which are ambient temperature and humidity have negligible effect on the infrared thermographical data. After analysis of current density and temperature distribution from concrete surface, corrosion level of reinforcement rebar embedded in concrete can be measured qualitatively based on the amount of electric current and heat flux.

Corrosion Resistance of Cr-bearing Rebar in Concrete Subjected to Carbonation and Chloride Attack (중성화와 염해의 복합 열화 환경하의 콘크리트 내에서의 Cr강방식철근의 방식성)

  • Tae, Sung-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.3
    • /
    • pp.115-122
    • /
    • 2006
  • Ten types of steel bars having different Cr contents were embedded in concretes with chloride ion contents of 0.3, 0.6, 1.2, and $2.4kg/m^3$ to fabricate specimens assuming such deteriorative environments. After being carbonated to the reinforcement level, these concretes were subjected to corrosion-accelerating cycles of heating/cooling and drying/wetting. The time-related changes in the corrosion area and corrosion loss of the Cr-bearing rebars were then measured to investigate their corrosion resistance. The results revealed that in a deteriorative environment prone to both carbonation and chloride attack, corrosion resistance was evident with a Cr content of 7% or more and 9% or more in concretes with chloride ion contents of 1.2 and $2.4kg/m^3$, respectively.

Visualization of Khitan Scripts in Ancient Documents using Active Infrared Thermography (고문서 거란문자의 능동형 적외선 열영상 가시화)

  • Kim, Nohyu;Chung, Jaeyoung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.2
    • /
    • pp.329-336
    • /
    • 2022
  • Unreadable Khitan scripts of ancient documents written by indian ink on parchment(sheepskin) are visualized by active infrared thermography without contacting and damaging the document which are deteriorated and aged presumably over many years. Sinusoidal infrared thermal wave using Halogen lamp is applied to the surface of the document in order to selectively magnify and record the thermal response of indian ink. The infrared image of the document captured in real time by infrared camera under the active external excitation shows the better sharpness and readability of Khitan characters than the optical image, from which many Khitan letters like ' ' and ' ' sounding as 'd' and 'ri' in English alphabet are detected and deciphered. It is concluded from the experiment that the active infrared thermography can be used as a promising method for digital reconstruction and preservation of ancient documents in the future.

Reducing the Test Time for Chemical/Mechanical Durability of Polymer Electrolyte Membrane Fuel Cells (고분자연료전지의 화학적/기계적 내구성 평가 시간 단축)

  • Sohyeong Oh;Donggeun Yoo;Kim Myeonghwan;Park Jiyong;Choi Yeongjin;Kwonpil Park
    • Korean Chemical Engineering Research
    • /
    • v.61 no.4
    • /
    • pp.517-522
    • /
    • 2023
  • A chemical/mechanical durability test of polymer membrane evaluation method is used in which air and hydrogen are supplied to the proton exchange membrane fuel cell (PEMFC) and wet/dry is repeated in the open circuit voltage (OCV) state. In this protocol, when wet/dry is repeated, voltage increase/decrease is repeated, resulting in electrode degradation. When the membrane durability is excellent, the number of voltage changes increases and the evaluation is terminated due to electrode degradation, which may cause a problem that the original purpose of membrane durability evaluation cannot be performed. In this study, the same protocol as the department of energy (DOE) was used, but oxygen was used instead of air as the cathode gas, and the wet/dry time and flow rate were also increased to increase the chemical/mechanical degradation rate of the membrane, thereby shortening the durability evaluation time of the membrane to improve these problems. The durability test of the Nafion 211 membrane electrode assembly (MEA) was completed after 2,300 cycles by increasing the acceleration by 2.6 times using oxygen instead of air. This protocol also accelerated degradation of the membrane and accelerated degradation of the electrode catalyst, which also had the advantage of simultaneously evaluating the durability of the membrane and the electrode.

Risk Assessment of Fire and Explosion of Methane (메탄의 화재 및 폭발 위험성 평가)

  • Ha Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.2 s.27
    • /
    • pp.1-7
    • /
    • 2005
  • The thermochemical parameters for safe handling, storage, transport, operation and process design of flammable substances are explosive limit, flash point, autoignition temperature, minimum oxygen concentration, heat of combustion etc.. Explosive limit and autoignition temperature are the major physical properties used to determine the fire and explosion hazards of the flammable substances. Explosive limit and autoignition temperature of methane fur LNG process safety were investigated. By using the literatures data, the lower and upper explosive limits of methane recommended 4.8 vol$\%$ and 16 vol$\%$, respectively. Also autoignition temperatures of methane with ignition sources recommended $540^{\circ}C$ at the electrically heated cruicible furnace (the whole surface heating) and recommended about $1000^{\circ}C$ in the local hot surface. The new equations for predicting the temperature dependence and the pressure dependence of the lower explosive limits for methane are proposed. The values calculated by the proposed equations were a good agreement with the literature data.

  • PDF

Analysis of Passive Cooling Effect of Membrane Shading Structure and the Tree by Field Observations in the Summer (하절기 복사환경 관측을 통한 수목과 일사차폐 막 구조물의 자연냉각효과)

  • Choi, Dong-Ho;Lee, Bu-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.137-146
    • /
    • 2007
  • This study is about the passive cooling effects of three outdoor solar shading facilities as trees, pergola with wistaria vine and membrane shading structure, which are expected to provide cool spots in the summer. Field observations of measuring thermal environment of selected facilities is executed. Thermal environment measuring was categorized as short wave radiation, long wave radiation, net radiation, globe temperature, surface temperature measured by infrared camera. Heat transfer mechanism is analyzed with overall data from field measurement. Results from this study are as below; 1) Radiation balance measured on shaded surface under membrane shading structure was 17%($86W/m^2$) of the unshaded surface radiation balance($511W/m^2$). 2) Surface temperature comparison between vegetation and membrane of the shading structure is performed at 3 o'clock in the afternoon. Surface temperature of vegetation was same as air temperature and that of membrane was $5^{\circ}C$ higher than air temperature. Vegetation transpiration is considered as the causing factor which make those differences. 3) Results from this study could be used as fundamental data for reducing heat island phenomena and continuos research on this subject would be needed.

Intra Block Copy Method for HEVC Extension based on Characteristics of TU boundary (TU 경계 특성을 이용한 HEVC Extension 화면 내 블록 복사 기법)

  • Park, Miso;Jeong, Jechang
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2014.06a
    • /
    • pp.264-267
    • /
    • 2014
  • 본 논문에서는 High Efficiency Video Coding (HEVC)의 확장 버전에 적용된 바 있는 화면 내 블록 복사 (Intra Block Copy; IntraBC) 기술에 대해 개선 알고리듬을 제안하고 있다. IntraBC 는 화면 내 부호화 진행 시, 예측 유닛 (prediction unit; PU)단위로 현재 부호화하고 있는 코딩 트리 유닛 (coding tree unit; CTU)의 왼쪽에 위치하는 CTU 를 탐색하는 기법이다. 이때, 왼쪽 CTU 에서 가장 비슷한 블록을 찾아 그 움직임 벡터 (motion vector)를 저장 및 전송하게 된다. 제안하는 알고리듬은 움직임 벡터를 찾기 전, 왼쪽의 복원된 CTU 에 대해 특정 필터를 적용하여 블록킹 열화 (blocking artifact)를 완화시키고, 더욱 정확하고 섬세한 움직임 벡터를 찾도록 하였고, 이는 자연영상보다 스크린 콘텐츠에 더욱 적합함을 확인할 수 있었다.

  • PDF

X-ray Medical Image Spatio-temporal Denoising Algorithm (엑스선 의료영상의 시공간 잡음제거 알고리즘)

  • Park, Sangwook;Joo, Hui Jin;Sohn, Jeongwoo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.10a
    • /
    • pp.685-686
    • /
    • 2016
  • 엑스선 투시촬영장치와 같은 의료용 동영상의 잡음 제거에 있어서 시공간 잡음제거 알고리즘을 제안한다. 제안된 알고리즘에서는 무한 충격 응답 기반 시간 영역 잡음 제거 얄고리즘을 도입하여 움직임이 적은 영역에서는 자연스러운 잡음 제거가 가능하며 움직임이 많은 영역에서는 연산량 측면에서 효율성을 고려하여 지역적 평균 필터 기반 공간 잡음 제거 알고리즘을 적용하여 움직임에 의한 흐려짐 열화 현상을 최소화 하면서 잡음 제거를 수행하였다.