• Title/Summary/Keyword: 자세한계성

Search Result 75, Processing Time 0.021 seconds

A Study on Electron Dose Distribution of Cones for Intraoperative Radiation Therapy (수술중 전자선치료에 있어서 선량분포에 관한 연구)

  • Kang, Wee-Saing;Ha, Sung-Whan;Yun, Hyong-Geun
    • Progress in Medical Physics
    • /
    • v.3 no.2
    • /
    • pp.1-12
    • /
    • 1992
  • For intraoperative radiation therapy using electron beams, a cone system to deliver a large dose to the tumor during surgical operation and to save the surrounding normal tissue should be developed and dosimetry for the cone system is necessary to find proper X-ray collimator setting as well as to get useful data for clinical use. We developed a docking type of a cone system consisting of two parts made of aluminum: holder and cone. The cones which range from 4cm to 9cm with 1cm step at 100cm SSD of photon beam are 28cm long circular tubular cylinders. The system has two 26cm long holders: one for the cones larger than or equal to 7cm diamter and another for the smaller ones than 7cm. On the side of the holder is an aperture for insertion of a lamp and mirror to observe treatment field. Depth dose curve. dose profile and output factor at dept of dose maximum. and dose distribution in water for each cone size were measured with a p-type silicone detector controlled by a linear scanner for several extra opening of X-ray collimators. For a combination of electron energy and cone size, the opening of the X-ray collimator was caused to the surface dose, depths of dose maximum and 80%, dose profile and output factor. The variation of the output factor was the most remarkable. The output factors of 9MeV electron, as an example, range from 0.637 to 1.549. The opening of X-ray collimators would cause the quantity of scattered electrons coming to the IORT cone system. which in turn would change the dose distribution as well as the output factor. Dosimetry for an IORT cone system is inevitable to minimize uncertainty in the clinical use.

  • PDF

An identity analysis of Mechanic Design through the Japan Animation (일본 애니메이션<신세기 에반게리온>으로 본 메카닉 디자인의 정체성 분석)

  • Lee, Jong-Han;Liu, Si-Jie
    • Cartoon and Animation Studies
    • /
    • s.50
    • /
    • pp.275-297
    • /
    • 2018
  • Japan's mechanic animation is widely known throughout the world. 1952년, Japan's first mechanic animation and the first TV animation, , has been popular since it's creation in 1952. Atom, a big hit at the time, has influenced many people. Japanese mechanic animations convey their unique traits and world view to the public In this paper, we are going to discuss the change of the Japanese mechanical design through comparison of the mechanical design, which has been booming since the 1990s in Japan; and the . I expect the results of this analysis to depict Japanese culture and thought reflected in animation, which is a good indication of worldwide cultural view of animation. unexpectedly influenced the Japanese animation industry after it screened in 1995, and there are still people constantly reinterpreting and analyzing it. This is the reaction of the audience to anticipate the mystery and endless conclusions of the work itself. The design elements of Evangelion are distinguished from other mechanical objects. Mechanic design based on human biotechnology can overcome limitations of machine and make you feel more human. The pilot 's boarding structure, which can contain human nature, is reinforced in the form of an enterprising plug, and the attitude of excavation makes humanity more prominent than a straight robot. Thus, pursues a mechanic design that can reflect human identity. can be selected as the mechanic animation of the 80's, and the "Neon Genesis Evangelion" of the 90's shows it with a completely different design. By comparing the mechanical design of two works, therefore, we examine the correlation between the message and the design of the work. presents the close relationship between the identity of the mechanical design and the contents. I would like to point out that mechanical design can be a good example and theoretical basis for the future.

Effects of Exercise Program by Type on Balance Ability and Muscle Activity In A Standing Posture (유형별 운동프로그램이 선 자세에서의 균형능력과 근활성도에 미치는 영향)

  • Kang, Jeong-Il;Park, Jun-Su;Park, Seung-Kyu;Yang, Dae-Jung;Choi, Hyun;Jeong, Dae-Keun;Kwon, Hye-Min;Moon, Young-Jun
    • Journal of Digital Convergence
    • /
    • v.12 no.7
    • /
    • pp.411-418
    • /
    • 2014
  • This study, in order to establish the effect of three exercise groups on the static and dynamic balancing abilities and the muscular activity, targeting adult males aged 20-29, assigned 15 men to each aquatic exercise group, trunk stabilization exercise group, and balance exercise group. The study was conducted from June, 2013 to August, 2013, and measured and compared the balancing ability and the muscle activity(tibialis anterior and gastrocnemius muscle) of the participants after performing intervention for 30 minutes a day, 3 days a week, for 6 weeks. As a result, on the comparison between before and after the intervention, there were significant differences in changes of the surface area and the whole path length in all the three groups(p<.05)(p<.01), and also on the dynamic balance, there was a significant difference in change of limited of stability(p<.05)(p<.01). On change of the muscle activity of tibialis anterior, both left and right sides showed statistically significant differences in all the three groups(p<.05)(p<.01), and gastrocnemius muscle showed a statistically significant difference in all the three groups except for the left side of the trunk stabilization exercise group(p<.05)(p<.01). It could be established that aquatic exercise is effective for improvement of the balancing ability and increase of the muscular activity, and we intend to propose specific aquatic exercise program development by conducting a study to determine the objective effect of aquatic exercise on the elderly or patients who have a poor balancing ability.

Analysis of Internet Biology Study Sites and Guidelines for Constructing Educational Homepages (인터넷상의 고등학교 생물 학습사이트 비교분석 및 웹사이트 구축방안에 관한 연구)

  • Kim, Joo-Hyun;Sung, Jung-Hee
    • Journal of The Korean Association For Science Education
    • /
    • v.22 no.4
    • /
    • pp.779-795
    • /
    • 2002
  • Internet, a world wide network of computers, is considered as a sea of information because it allows people to share information beyond the barriors of time and space. However, in spite of the unmeasurable potential applications of the internet, its use in the field of biology education has been extremely limited mainly due to the scarcity of good biology-related sites. In order to provide useful guidelines for constructing user-friendly study sites, which can help high school students with different intellectual levels to study biology, comparative studies were performed on selected educational sites. Initially, hundreds of related sites were examined, and, subsequently, four distinct sites were selected not only because they are well organized, but also because each is unique in its contents. Also, a survey was carried out against the users of each site. The survey results indicated that the high school students regard the web-based biology study tools as effective teaching methods although there might be some bias in criteria for selecting target sites. In addition to the detailed biology topics and the related biology informations, multimedia data including pictures, animations and movies are found to be one of the important ingredients for desirable biology study sites. Thus, the inclusion of multimedia components should also be considered when developing a systematic biology study site. Overall, the role of the cyber space is expected to become more and more important. Since the development of the user-satisfied and self-guided sites require interdisciplinary collaborational efforts which should be made to promote extensive communication among teachers, education professionals, and computer engineers. Furthermore, the introduction of good biology study sites to the students by their teachers is also important factor for the successful web-based education.

The Effect of PET/CT Images on SUV with the Correction of CT Image by Using Contrast Media (PET/CT 영상에서 조영제를 이용한 CT 영상의 보정(Correction)에 따른 표준화섭취계수(SUV)의 영향)

  • Ahn, Sha-Ron;Park, Hoon-Hee;Park, Min-Soo;Lee, Seung-Jae;Oh, Shin-Hyun;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.77-81
    • /
    • 2009
  • Purpose: The PET of the PET/CT (Positron Emission Tomography/Computed Tomography) quantitatively shows the biological and chemical information of the body, but has limitation of presenting the clear anatomic structure. Thus combining the PET with CT, it is not only possible to offer the higher resolution but also effectively shorten the scanning time and reduce the noises by using CT data in attenuation correction. And because, at the CT scanning, the contrast media makes it easy to determine a exact range of the lesion and distinguish the normal organs, there is a certain increase in the use of it. However, in the case of using the contrast media, it affects semi-quantitative measures of the PET/CT images. In this study, therefore, we will be to establish the reliability of the SUV (Standardized Uptake Value) with CT data correction so that it can help more accurate diagnosis. Materials and Methods: In this experiment, a total of 30 people are targeted - age range: from 27 to 72, average age : 49.6 - and DSTe (General Electric Healthcare, Milwaukee, MI, USA) is used for equipment. $^{18}F$- FDG 370~555 MBq is injected into the subjects depending on their weight and, after about 60 minutes of their stable position, a whole-body scan is taken. The CT scan is set to 140 kV and 210 mA, and the injected amount of the contrast media is 2 cc per 1 kg of the patients' weight. With the raw data from the scan, we obtain a image showing the effect of the contrast media through the attenuation correction by both of the corrected and uncorrected CT data. Then we mark out ROI (Region of Interest) in each area to measure SUV and analyze the difference. Results: According to the analysis, the SUV is decreased in the liver and heart which have more bloodstream than the others, because of the contrast media correction. On the other hand, there is no difference in the lungs. Conclusions: Whereas the CT scan images with the contrast media from the PET/CT increase the contrast of the targeted region for the test so that it can improve efficiency of diagnosis, there occurred an increase of SUV, a semi-quantitative analytical method. In this research, we measure the variation of SUV through the correction of the influence of contrast media and compare the differences. As we revise the SUV which is increasing in the image with attenuation correction by using contrast media, we can expect anatomical images of high-resolution. Furthermore, it is considered that through this trusted semi-quantitative method, it will definitely enhance the diagnostic value.

  • PDF