• Title/Summary/Keyword: 자력

Search Result 1,020, Processing Time 0.027 seconds

Effect of Crystallographic Orientation of CrNi Underlayer on Magnetic Properties of CoCrTa / CrNi Magnetic Recording Media Deposited by E-Beam Evaporator (E-Beam Evaporator로 제조된 CoCrTa/ Cr-Ni 자기기록 매체의 자기적 특성에 미치는 Cr-Ni 하지층의 결정배향효과)

  • 고흥재;남인탁
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.4
    • /
    • pp.205-211
    • /
    • 1997
  • The magnetic properties change which was induced by addition of small amount of Ni into Cr underlayer in CoCrTa/ CrNi thin film deposited by electron beam evaporator was investigated. The additional Ni element was found to be beneficial for incease in the coercivity of the thin film deposited at the room temperature. The origin of coercivity increase was elucidated by crystal orientation and microstructure investigation using XRD and AFM respectively. It was found that the grain size were increased by Ni addition. The coercivity of the film with CrNi underlayer is lower than that of film with Cr underlayer when prepared with higher substrate temperature. This result may be originated with the increase in grain size. When film was deposited at 280 $^{\circ}C$ substrate temperature, Cr segregation in grain boundary is found to be the other factor for determining coercivity value.

  • PDF

Influence of Target Manufacturing Condition on the Coercive Force and Effective Permeability of Permalloy (타게트 제조조건이 퍼멀로이 박막의 보자력 및 투자율에 미치는 영향)

  • 김현태;김상주;한석희;김희중;강일구;김인응
    • Journal of the Korean Magnetics Society
    • /
    • v.4 no.4
    • /
    • pp.319-325
    • /
    • 1994
  • Permalloy films were deposited by an RF magnetron sputtering method using several different targets which had been cold-rolled and annealed at various temperatures to give different microstructure and texture. The grain refinement occurs at high temperature annealing due to recrystallization and subsequently the initial (110) target texture transforms to the random texture. The coercive forces of thin films fabricated using targets which are not recrystallized are below 0.2 Oe in the AI pressure range of 1~5 mTorr and the lowest coercive force achieved is 0.07 Oe. The low value of coercive force, 0.25 Oe, is only obtained at the sputtering conditions of 400 W and 1 mTorr, and 300 W and 5 mTorr when recrystallized targets are used. The internal stress changes from compressive to tensile as the Ar pressure increases, the stress-free being at 5 mTorr. The changes of coercive force and permeability can be well interpreted by the differences from the composition and the internal stress.

  • PDF

Conversion of 3-Component Magnetic Data into Geodetic Coordinate System by Using Clinometer and GNSS Compass (경사계와 GNSS 나침반을 이용한 3성분 자력 탐사자료의 측지 좌표계로의 변환 방법)

  • Jeon, Tae-Hwan;Rim, Hyoungrea;Park, Young-Sue;Lim, Muteak;Shin, Young-Hong
    • Geophysics and Geophysical Exploration
    • /
    • v.16 no.2
    • /
    • pp.91-96
    • /
    • 2013
  • This study proposes a method to correct inclination of instrument during exploration with a biaxial clinometer and GNSS compass. In 3-component magnetometry, measured vectors are ordinarily described in randomly inclined observation coordinate system due to movement, vibration, and shaking of instrument. Therefore, rotation angles of observation plane are needed to transform it into geodetic coordinate system. In this study, we measured inclination angles of observation plane by using 2-axis clinometer and GNSS compass, and derived proper parameters for rotational transform from them. We applied the conversion method to on-board 3-component magnetometry, and then transformed raw data into proper values on geodetic coordinate system.

Aeromagnetic Interpretation of the Southern and Western Offshore Korea (한국 서남근해에 대한 항공자력탐사 해석)

  • Baag Czango;Baag Chang-Eob
    • The Korean Journal of Petroleum Geology
    • /
    • v.2 no.2 s.3
    • /
    • pp.51-57
    • /
    • 1994
  • Analysis of the aeromagnetic data aquired by US Navy in the year 1969 permits us to predict a new sedimentary basin, Heugsan Basin, south of the known Gunsan Basin in Block Ⅱ. The basin appears to consist of three sub-basins trending NNW-SSE. The results of our analysis provide not only an independent assessment of the Gunsan Basin, but also new important information on the tectonic origin and mechanism for the two basins as well as for the entire region. The basin forming tectonic style is interpreted as rhombochasm associated with double overstepped left-lateral wrench faults. From the magnetic evidence, a few NE-SW trending major onshore faults are extended to the study area. We also interpreted the nature of the faults to be left-lateral wrenches. This new gross structural style is consistent with the results of recent Yeongdong Basin analysis by Lee. The senses of fault movement are also supported by the paleomagnetic evidence that the Philippine Sea had experienced an 80-degree clockwise rotation since the Eocene. Based on a 2 $\frac{1}{2}$ model study the probable maximum thickness of the sediments in the Gunsan Basin is approximately 7500 meters. We believe that the new Heugsan Basin was left unidentified because a high velocity layer may be overlying the basin. Because the overall structural configuration of the Heugsan Basin appears to be favorable for hydrocarbon accumulation, a detailed airborne magnetic survey is recommended in the area in order to verify the magnetic expression of this thick basin. A detailed subsequent marine gravity survey is also recommended in order to delineate the sedimentary section and to acquire supplemental data to the magnetic method only if an overlying high velocity layer is confirmed. Otherwise a high energy source seismic survey may be more effective.

  • PDF

Soil Washing Coupled with the Magnetic Separation to Remediate the Soil Contaminated with Metal Wastes and TPH (자력선별과 토양세척법을 연계하여 금속폐기물과 TPH로 복합 오염된 토양 동시 정화)

  • Han, Yikyeong;Lee, Minhee;Wang, Sookyun;Choi, Wonwoo
    • Economic and Environmental Geology
    • /
    • v.52 no.1
    • /
    • pp.1-12
    • /
    • 2019
  • Batch experiments for the soil washing coupled with the magnetic separation process were performed to remediate the soil contaminated with metal and oil wastes. The soil was seriously contaminated by Zn and TPH (total petroleum hydrocarbon), of which concentrations were 1743.3 mg/kg and 3558.9 mg/kg, respectively, and initial concentrations of Zn, Pb, Cu, and TPH were higher than the 2nd SPWL (soil pollution warning limit: remediation goal). The soil washing with acidic solution was performed to remove heavy metals from the soil, but Pb and Zn concentration of the soil maintained higher than the 2nd SWPL even after the soil washing with acidic solution. The 2nd soil washing was repeated to increase the Pb and Zn removal efficiency and the Zn and Pb removal efficiencies additionally increased by only 8 % and 5 %, respectively, by the 2nd soil washing (> 2nd SPWL). The small particle separation from the soil was conducted to decrease the initial concentration of heavy metals and to increase the washing effectiveness before the soil washing and 4.1 % of the soil were separated as small particles (< 0.075 mm in diameter). The small particle separation lowered down Zn and Pb concentrations of soil to 1256.3 mg/kg (27.9 % decrease) and 325.8 mg/kg (56.3 % decrease). However, the Zn concentration of soil without small particles still was higher than the 2nd SPWL even after the soil washing, suggesting that the additional process is necessary to lower Zn concentration to below the 2nd SPWL after the treatment process. As an alternative process, the magnetic separation process was performed for the soil and 16.4 % of soil mass were removed, because the soil contamination was originated from unreasonable dumping of metal wastes. The Zn and Pb concentrations of soil were lowered down to 637.2 mg/kg (63.4 % decrease) and 139.6 mg/kg (81.5 % decrease) by the magnetic separation, which were much higher than the removal efficiency of the soil washing and the particle separation. The 1st soil washing after the magnetic separation lowered concentration of both TPH and heavy metals to below 2nd SPWL, suggesting that the soil washing conjugated with the magnetic separation can be applied for the heavy metal and TPH contaminated soil including high content of metal wastes.

A study on the Magnetic Properties of Co-Cr-Ta Thin Films for Perpendicular Magnetic Recording (수직자기기록용 Co-Cr-Ta 박막의 자기적 성질에 대한 연구)

  • 황충호;박용수;장평우;이택동
    • Journal of the Korean Magnetics Society
    • /
    • v.3 no.1
    • /
    • pp.41-47
    • /
    • 1993
  • Effects of Ta addition on Co-Cr pependicular magnetic recording media were studied to obtain high perpen-dicular coercivity at lower substrate temperature. For the purpose. magnetic properties and microstructures of Co-Cr-(Ta) films were studied by varying the Cr contents from 17 to 21 at.% and Ta contents for 0 to 3.2 at.%. Effectiveness of Ta addition in increasing perpendicular coercivity was significant for lower Cr content films. The increasement of perpendicular coercivity was more pronounced for the films deposited on $100^{\circ}C$ heated substrate in the case of ${(Co_{83}Cr_{17})}_{98.4}Ta_{1.6}$ composition. The cause of the increase of perpendicular coercivity was considered due to not the grain refinement effects and the improvement of c-axis alignments but increase of Ta and Cr segregation.

  • PDF

A Study of Relationship between Magnetic Properties and Microstructure of CoNiCr/Cr Double Layer Thin Film Magnetic Recording Media (자기기록매체 CoNiCr/Cr 이중박막의 자기적 성질과 미세구조와의 관계연구)

  • 김희삼;남인탁;홍양기
    • Journal of the Korean Magnetics Society
    • /
    • v.3 no.3
    • /
    • pp.215-220
    • /
    • 1993
  • Microstructural dependence of magnetic property of RF/DC sputtered $Co_{69.0}Ni_{18.5}Cr_{12.5}/Cr$ double layer thin film was studied. Grain size was found to be decreased with substrate temperature in the range of $100-200^{\circ}C$ and Cr underlayer thickness(from $500\;{\AA}-2000\;{\AA}$). The peaks (200) and (1120) of X-ray diffraction patterns were evidently grown with the substrate temperature for the Cr underlayer and magnetic layer, respectively. The CoNiCr magnetic layer was found to be well epitaxialy grown on Cr underlayer, and subsequently the coercivity was enhanced.

  • PDF

Effect of Blending Aids the Magnetic Properties of Anisotropic NdFeB Magnet Prepared by CAPA Process (통전가압법으로 제조한 이방성 NdFeB 영구자석의 자기특성에 미치는 첨가제의 영향)

  • Kim, H.T.;Cho, S.H.;Kim, Y.B.;Kim, H.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.3
    • /
    • pp.88-93
    • /
    • 2002
  • Rapidly solidified NdFeB powders were mixed with fine powders of pure metal elements before CA-press employed to obtain a fully dense isotropic precursor. Subsequently, the precursor was deformed by CA-deformation to obtain an anisotropic magnet. The CA-deformed anisotropic NdFeB magnets with 0.3 wt.% Zn or Sn exhibited the coercivities about 80% higher (11.4. and 11.2 kOe, respectively) than that (6.4 kOe) of the additive-free magnet.

Japanese Armed Tunnels Applying Geoinformatics (일제 진지동굴의 Geoinformatics 적용 연구)

  • Oh, Jong-Woo;Oh, Seung-Hoon
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2016.11a
    • /
    • pp.242-246
    • /
    • 2016
  • 해방70주년기념사업으로 일제강점기 동안에 조선인 강재징용으로 구축된 진진동굴에 대한 Geoinformatics 적용 학술조사를 통하여 구조물의 분포와 활용에 대한 내역을 규명하고, 일제에 의하여 자행된 국토훼손의 실상 및 만행을 출판 및 국내외 학술발표 자료로 할용 하고자 하였다. Geoinformatics 적용 조사탐사의 범위는 전국을 대상으로 하며, 서울지역, 인천지역, 대구지역, 부산지역, 제주지역, 대전지역 이외 도서지역 등 미 탐사지역에 대하여 지속가능한 수행을 추진함에 대한 문헌자료, 탐문조사, GIS분석, 지질광물분석 및 공동(空洞)조사 등으로 실시하며, 지표 및 지하조사의 방법은 위성영상분석(Remote Sensing), 물리탐사(전기/자력탐사) 및 동공 확인 시추(구경: 50mm)에 의한 도면작성으로 분포, 형상, 내용 등으로 다음과 같은 조사내용을 제기하였다. 일제동굴진지에 대한 geoinformatics기법의 접근에 의한 기반을 적용해 본 결과 문헌자료, 탐문조사, GIS분석, 지질광물분석 및 공동(空洞)조사 등으로 실시하며, 학술조사의 방법은 위성영상분석(Remote Sensing), 지구물리탐사(전기/자력탐사) 및 동공 확인 시추 등의 종합적인 정성적이며 정량적인 탐사에 의한 적용이 효과적인 결과를 초래할 수 있다는 결론에 도달하였다.

  • PDF

Background Noise Reduction by Software Methods in the 37-channel SQUID Magnetometer System (뇌자도 측정용 37채널 스퀴드 자력계에서의 합성 미분계 및 적응필터, 주파수영역 적응필터에 의한 배경잡음 제거)

  • 김기웅;이용호;권혁찬;김진목;강찬석
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.167-173
    • /
    • 2003
  • Measuring subtle neuromagnetic signals requires eliminating background noises. Especially, a SQUID magnetometer is very sensitive to the magnetic noise even from a distant source. As typical software methods, we use the synthetic gradiometer of the adaptive filtering to reduce the noises. In this article, we present noise reduction effects in our 37-channel SQUID magnetometer system by applying each method including the frequency-domain adaptive filtering and discuss a selective application of the methods to the detection of clinical magnetoencephalogram signals.