• Title/Summary/Keyword: 자기 축소 모델

Search Result 12, Processing Time 0.025 seconds

A Study on Deduction and Characteristic Analysis of Magnetic Equivalent Circuit Parameters of a Rotary-typed Small-scaled LIM for a Railway Transit (철도차량용 선형유도전동기 축소-회전형모델의 자기등가회로 파라미터 도출 및 특성 분석 연구)

  • Park, Chan-Bae;Lee, Hyung-Woo;Lee, Byung-Song
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.4
    • /
    • pp.404-411
    • /
    • 2010
  • Authors conducted a deduction and characteristic calculation of the some parameters using a magnetic equivalent circuit method to verify a basic design result of a rotary-typed small-scaled linear induction motor for a railway transit. In a LIM, it is possible to express the parameters of the magnetic equivalent circuit into a function of the shape of the secondary aluminium plate and the airgap between the LIM primary core and the secondary aluminium plate. It means that the LIM properties can be changed considerably by the shape of the secondary aluminium plate and the airgap between the LIM primary core and the secondary aluminium plate. So, authors analyzed a tendency of changes of the magnetic equivalent circuit parameters and the LIM characteristics by changing of the airgap, the thickness of the secondary aluminium plate and the overhang length and shape of a rotary-typed small-scaled LIM, and accomplished a basic research to develop a real-scaled LIM for a railway transit.

Study on Analysis Method for Ship's Ferromagnetic Signature using Magnetic Mock-up Model (축소 모델을 이용한 함정 자기장 신호 해석 기법 연구)

  • Yang, Chang-Seob;Chung, Hyun-Ju
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.38-51
    • /
    • 2007
  • This paper describes research results for the measurement and analysis method of magnetic signatures generated from the ship's magnetic mock-up model. In this paper, we present the theoretical and experimental techniques for the separation of the permanent and the induced magnetic field from the measured magnetic signature of the mock-up model. Also, we describe the prediction method of the induced magnetic field generated from mock-up model using the Magnet s/w, one of the FEM analysis tools for the electro-magnetic field and the magnetic dipole modelling method based on the least square techniques. The proposed modelling and analysis methods can be used for the prediction and the analysis of the static magnetic field generated from the real naval ship as well as the mock-up model.

Analytic Verification of Optimal Degaussing Technique using a Scaled Model Ship (축소 모델 함정을 이용한 소자 최적화 기법의 해석적 검증)

  • Cho, Dong-Jin
    • Journal of the Korean Magnetics Society
    • /
    • v.27 no.2
    • /
    • pp.63-69
    • /
    • 2017
  • Naval ships are particularly required to maintain acoustic and magnetic silence due to their operational characteristics. Among them, underwater magnetic field signals derived by ships are likely to be detected by threats such as surveillance systems and mine systems at close distance. In order to increase the survivability of the vessels, various techniques for reducing the magnetic field signal are being studied and it is necessary to consider not only the magnitude of the magnetic field signal but also the gradient of it. In this paper, we use the commercial electromagnetic finite element analysis tool to predict the induced magnetic field signal of ship's scaled model, and arrange the degaussing coil. And the optimum degaussing current of the coil was derived by applying the particle swarm optimization algorithm considering the gradient constraint. The validity of the optimal degaussing technique is verified analytically by comparing the magnetic field signals after the degaussing with or without gradient constraint.

A Study on Dipole Modeling Method for Ship's Magnetic Anomaly using Singular Value Decomposition Technique (특이치 분해 방법에 의한 함정 자기원 다이폴 모델링 방안 연구)

  • Yang, Chang-Seob;Chung, Hyun-Ju
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.6
    • /
    • pp.259-264
    • /
    • 2007
  • This paper describes the mathematical modeling method for the static magnetic field signature generated by a magnetic scale model. we proposed the equivalent dipole modeling method utilizing a singular value decomposition technique from magnetic field signatures by magnetic sensors are located special depths below the scale model. The proposed dipole modeling method was successfully verified through comparisons with the real measured values in our non-magnetic laboratory. Using the proposed method, it is possible to predict and analyze static magnetic field distributions at any difference depths generated from the real ships as well as a scale model ship.

A Study on a Conversion Design between a Small-scaled PM-LSM and EM-LSM for Ultra-High Speed Railway Transit (초고속열차용 축소형 PM-LSM과 EM-LSM의 변환 설계 연구)

  • Park, Chan-Bae;Lee, Byung-Song;Lee, Hyung-Woo;Kim, Nam-Po;Han, Kyung-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1193_1194
    • /
    • 2009
  • 일반적으로 자기부상열차는 고속, 내구성, 안전성 등을 만족하는 가장 적합한 시스템 중 하나로 부각되고 있다. 300[km/h] 이하의 중저속 자기부상철도의 경우, 추진용으로 선형유도전동기가 사용되고 있으며, 초고속 자기부상철도의 경우, 선형유도전동기보다 고효율, 고출력의 특성을 가지는 선형동기전동기가 사용되고 있다. 한국철도기술연구원에서는 2008년도부터 700[km/h]급 초고속튜브열차용 선형동기전동기연구를 시작하였으며, 추진/부상 일체형 권선형 선형동기전동기연구를 수행하고 있다. 따라서 본 논문에서는 초고속튜브열차용 선형동기전동기 연구의 일환으로, 축소형 영구자석형 선형동기전동기(PM-LSM)의 수학적 방법에 의한 기본설계를 수행하였으며, 이를 이동자만을 고려한 자기등가회로법을 이용하여 권선형 선형동기전동기(EM-LSM)로 변환 설계를 수행하였다. 또한 설계된 PM-LSM과 EM-LSM 모델의 FEM 해석을 이용한 특성 분석을 통하여 본 논문에서 제안한 변환 설계기법의 정확도 검증 연구를 수행하였다.

  • PDF

Optimal Sensor Placement for Improved Prediction Accuracy of Structural Responses in Model Test of Multi-Linked Floating Offshore Systems Using Genetic Algorithms (다중연결 해양부유체의 모형시험 구조응답 예측정확도 향상을 위한 유전알고리즘을 이용한 센서배치 최적화)

  • Kichan Sim;Kangsu Lee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.37 no.3
    • /
    • pp.163-171
    • /
    • 2024
  • Structural health monitoring for ships and offshore structures is important in various aspects. Ships and offshore structures are continuously exposed to various environmental conditions, such as waves, wind, and currents. In the event of an accident, immense economic losses, environmental pollution, and safety problems can occur, so it is necessary to detect structural damage or defects early. In this study, structural response data of multi-linked floating offshore structures under various wave load conditions was calculated by performing fluid-structure coupled analysis. Furthermore, the order reduction method with distortion base mode was applied to the structures for predicting the structural response by using the results of numerical analysis. The distortion base mode order reduction method can predict the structural response of a desired area with high accuracy, but prediction performance is affected by sensor arrangement. Optimization based on a genetic algorithm was performed to search for optimal sensor arrangement and improve the prediction performance of the distortion base mode-based reduced-order model. Consequently, a sensor arrangement that predicted the structural response with an error of about 84.0% less than the initial sensor arrangement was derived based on the root mean squared error, which is a prediction performance evaluation index. The computational cost was reduced by about 8 times compared to evaluating the prediction performance of reduced-order models for a total of 43,758 sensor arrangement combinations. and the expected performance was overturned to approximately 84.0% based on sensor placement, including the largest square root error.

Analysis of ELF Magnetic Field Reduction Ratio on Passive Loop Using Scale Down Model of Transmission Line (축소 모델을 이용한 수동 루프 송전선 자기장 저감율 분석)

  • Cho, Yeun-Gyu;Myung, Sung-Ho;Lee, Jae-Bok;Chang, Sug-Hun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.12 s.115
    • /
    • pp.1231-1239
    • /
    • 2006
  • In this research magnetic field reduction effect of each passive loop was analyzed by using the scale down models of transmission lines. This paper examined magnetic field reduction effect of the passive loop that will be applied to actual facility through the experiment, which is about double vertical transmission line and horizontal transmission line. Consequently, by confirming the fact that magnetic field reduction effect can be obtained to 50 % by passive loop without reactive compensation, we insured technology about application of passive loop. And the case of 3 turns of loop showed two times reduction effect than that of 1 turns of loop in reducing magnetic field. Vertical passive loop is more efficient than horizontal passive loop in the aspect of reducing magnetic field on double vertical transmission lines. What is more, vertical passive loop showed good effect of reducing magnetic field in a far distance as well as in a short distance.

An Application of Statistical Downscaling Method for Construction of High-Resolution Coastal Wave Prediction System in East Sea (고해상도 동해 연안 파랑예측모델 구축을 위한 통계적 규모축소화 방법 적용)

  • Jee, Joon-Bum;Zo, Il-Sung;Lee, Kyu-Tae;Lee, Won-Hak
    • Journal of the Korean earth science society
    • /
    • v.40 no.3
    • /
    • pp.259-271
    • /
    • 2019
  • A statistical downscaling method was adopted in order to establish the high-resolution wave prediction system in the East Sea coastal area. This system used forecast data from the Global Wave Watch (GWW) model, and the East Sea and Busan Coastal Wave Watch (CWW) model operated by the Korea Meteorological Administration (KMA). We used the CWW forecast data until three days and the GWW forecast data from three to seven days to implement the statistical downscaling method (inverse distance weight interpolation and conditional merge). The two-dimensional and station wave heights as well as sea surface wind speed from the high-resolution coastal prediction system were verified with statistical analysis, using an initial analysis field and oceanic observation with buoys carried out by the KMA and the Korea Hydrographic and Oceanographic Agency (KHOA). Similar to the predictive performance of the GWW and the CWW data, the system has a high predictive performance at the initial stages that decreased gradually with forecast time. As a result, during the entire prediction period, the correlation coefficient and root mean square error of the predicted wave heights improved from 0.46 and 0.34 m to 0.6 and 0.28 m before and after applying the statistical downscaling method.

A Scheme for Implementing control Panel of Central control-Based Microcomputer with Microprocessor (중앙 집중 제어용 마이크로컴퓨터의 제어반을 마이크로프로세서로 구성하는 방안)

  • 박하인;진달복
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.2
    • /
    • pp.66-74
    • /
    • 1985
  • An idea is presented in this paper that control panel be implemented with a ${\mu}$-processor instead of interrupt based logic circuits. To prove that the idea is reasonable, a ${\mu}$-computer controlled traffic light control system is chosen as a model, and its control panel is imple-mented witll a f-processor. The result is that the microprocessor-based control panel performs its function very well.

  • PDF

Stochastic Response of a System with Autoparametric Coupling (자기매계변수 연성을 갖는 응답의 통계적 특성)

  • 조덕상;김영종
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.13 no.4
    • /
    • pp.387-394
    • /
    • 2000
  • The nonlinear modal interaction of an autoparametric system under a broadband random excitation is investigated. The specific system examined is an autoparametric vibration absorber with internal resonance, which is typical of many common structural configurations. By means of Gaussian closure scheme the dynamic moment equations explaining the random responses of the system are reduced to a system of autonomous ordinary differential equations of the first and second moments. In view of equilibrium solutions of this system and their stability we examine the system responses. We could not find the destabilizing effect of damping, which was reported in References (18) and (20). The saturation phenomenon, which is well known in deterministic nonlinear system, did not take place lot this system subject to broadband random excitation.

  • PDF