• 제목/요약/키워드: 자기 이완

검색결과 129건 처리시간 0.022초

$In$ $vitro$ MRI and Characterization of Rat Mesenchymal Stem Cells Transduced with Ferritin as MR Reporter Gene (페리틴 리포터 유전자를 발현하는 백서 중간엽 줄기세포의 특성과 자기공명영상 연구)

  • Shin, Cheong-Il;Lee, Whal;Woo, Ji-Su;Park, Eun-Ah;Kim, Pan-Ki;Song, Hyun-Bok;Kim, Hoe-Suk
    • Investigative Magnetic Resonance Imaging
    • /
    • 제16권1호
    • /
    • pp.47-54
    • /
    • 2012
  • Purpose : This study was performed to evaluate the characteristics of rat mesenchymal stem cells (RMSCs) transduced with human ferritin gene and investigate $in$ $vitro$ MRI detectability of ferritin-transduced RMSCs. Materials and Methods: The RMSCs expressing both myc-tagged human ferritin heavy chain subunit (myc-FTH) and green fluorescence protein (GFP) were transduced with lentiviurs. Transduced cells were sorted by GFP expression using a fluorescence-activated cell sorter. Myc-FTH and GFP expression in transduced cells were detected by immunofluorescence staining. The cell proliferative ability and viability were assessed by MTT assay. The RMSC surface markers (CD29+/CD45-) were analyzed by flow cytometry. The intracellular iron amount was measured spectrophotometically and the presence of ferritin-iron accumulation was detected by Prussian blue staining. $In$ $vitro$ magnetic resonance imaging (MRI) study of cell phantoms was done on 9.4 T MR scanner to evaluate the feasibility of imaging the ferritin-transduced RMSCs. Results: The myc-FTH and GFP genes were stably transduced into RMSCs. No significant differences were observed in terms of biologic properties in transduced RMSCs compared with non-transduced RMSCs. Ferritin-transduced RMSCs exhibited increased iron accumulation ability and showed significantly lower $T_2$ relaxation time than non-transduced RMSCs. Conclusion: Ferritin gene as MR reporter gene could be used for non-invasive tracking and visualization of therapeutic mesenchymal stem cells by MRI.

Early Changes of Left Ventricular Geometry and Function after Surgical Ventricular Restoration and Mitral Valve Annuloplasty: Magnetic Resonance Imaging (외과적 심실 복원과 승모판 고리성형 후 좌심실 형태와 기능의 초기 변화: 자기공명영상)

  • Choi, Byoung-Wook;Chang, Byung-Chul;Kim, Young-Jin;Hur, Jin;Lee, Hye-Jeong;Kim, Tae-Hoon;Choe, Kyu-Ok
    • Investigative Magnetic Resonance Imaging
    • /
    • 제12권1호
    • /
    • pp.40-48
    • /
    • 2008
  • Purpose : We sought to determine the early change of ventricular geometry and function after concomitant surgeries of modified Dor procedure and mitral valve annuloplasty by using magnetic resonance imaging. Materials and Methods : We enrolled 21 patients with dilated heart failure who underwent modified Dor procedure (n=8), mitral valve annuloplasty (n=6), or both surgeries (n=7). Cine MRI was used to assess left ventricular dimensions and function before and after surgery. We measured the left ventricular end-diastolic and end-systolic volumes and the dimensions of the left ventricular long-axis and short-axis. Left ventricular stroke volume, ejection fraction, and sphericity index were calculated from these measurements. These parameters were analyzed and compared between three different surgery groups to explain the combined effect of the concomitant surgeries. Results : MRI was performed within average $12\;{\pm}\;15$ days (range 1-58 days) before and $38\;{\pm}\;50$ days (range 7- 231 days) after the surgery. The patients who underwent concomitant surgeries had more profound enlargement of left ventricle and decreased contractility prior to surgery than those in the patients who underwent single surgical procedure. Left ventricular end-diastolic volume and endsystolic volume significantly decreased in all patients regardless of surgery type after surgery. Ejection fraction significantly increased only in the patients who got modified Dor procedure without mitral valve annuloplasty (25.4% to 40.7%). Sphericity index increased in patients with modified Dor procedure but decreased in patients with mitral valve annuloplasty (0.65 to 0.78 vs. 0.75 to 0.65). In the patients who underwent concomitant surgeries showed no significant change in sphericity index after surgery. Conclusion : The early change of the left ventricular geometry and function after the concomitant surgeries with modified Dor procedure and mitral valve annuloplasty in patients with dilated heart failure includes a marked reduction in left ventricular volume and in stroke volume. The shape of the left ventricle does not change because the effect of sphericity index decrease from mitral valve annuloplasty is counteracted by the effect of sphericity index increase from modified Dor procedure. Improvement of left ventricular ejection fraction is not the early change after the concomitant surgeries.

  • PDF

A Study on the Evaluation of 3D Dose Distribution using Normoxic Polymer Gel (정상산소 중합체 겔 선량계를 이용한 3차원 방사선량 평가에 관한 연구)

  • Chung, Se-Young;Kim, Young-Bum;Kwon, Young-Ho;Lee, Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • 제19권1호
    • /
    • pp.7-17
    • /
    • 2007
  • Purpose: As increasing complexity of modern radiotherapy technique, more developing dosimetry is required. Polymer gel dosimeters offer a wide range of potential applications with high resolution and assured quality in the thee-dimensional verification of complex dose distribution such as intensity-modulated radiotherapy (IMRT). The purpose of this study is to find the most sensitive and suitable gel as a dosimeter by varying its composition ratio and its condition such as temperature during manufacturing. Materials and Methods: Each polymer gel with various ratio of composition was irradiated with the same amount of photon beam accordingly. Various polymer gels were analyzed and compared using a dedicated software written in visual C++ which converts TE images to R2 map images. Their sensitivities to the photon beam depending on their composition ratio were investigated. Results: There is no dependence on beam energy nor dose rate, and calibration curve is linear. Conclusion: The polymer gel dosimeter developed by using anti-oxidant in this study proved to be suitable for dosimetry.

  • PDF

Establishing EMG Measurement System for Measurement of Motor Nerve Response in Transcranial Magnetic Stimulation (경두개 자기자극 시 운동신경 유발응답 측정을 위한 근전도 측정 시스템 구축)

  • Lee, Geun-Yong;Kim, Su-Hwan;Jo, Jae-Hyun;Yoon, Se-Jin;Lee, Sang-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • 제12권4호
    • /
    • pp.413-418
    • /
    • 2019
  • Studies are now actively underway to confirm the degree of treatment and rehabilitation of patients with brain-related diseases (dementia, schizophrenia, depression, Parkinson's disease). Among them, Transcranial magnetic stimulation (TMS) is widely used in treatment because it is a technique that is used for noninvasive brain neuron control in patients with brain disorders. It can be seen that muscle fatigue of normal people increases during Transcranial magnetic stimulation. Therefore, in this paper, our purpose is to build an EMG measurement system to measure motor neuron-induced response during transcranial magnetic stimulation and We identify a motor-neutral response system using tendency in the RMS graph. As an experimental method, the Raw Data received through the surface EMG device and analyzed by RMS technique, after the contraction and relaxation movement of the biceps brachii. As a result of the experiment, we confirmed the trend of rising RMS graph, and it will can be used to determine the self-stimulation intensity for each individual in consideration of the data of the motor-neutral response.

Behavior Problem According to Children's Temperament and Self-Regulation (유아의 기질과 자기조절능력에 따른 문제행동)

  • Jung, Hye-Jin;Lee, Wan-Jeong
    • Journal of Families and Better Life
    • /
    • 제27권3호
    • /
    • pp.159-170
    • /
    • 2009
  • The purpose of this study was (1) to investigate the difference of temperament, self-regulation, and problem behavior according to children's gender and age, (2) to investigate the relationship among three variables by use of canonical correlation analysis. The subjects were 210 children ages from 3 to 5 in five day-care center in Incheon city. The SPSS WIN 12.0 Program was used to analyze the collected data. The statistical methods were Frequency, Percentage, Cronbach's ${\alpha}$, Two-way ANOVA, Correlation analysis, and Canonical Correlation analysis. The major results of this research are summarized as follows: (1) Children's temperament were significantly different by their gender and age. The boys got higher score than girls in adaptability, activity, and total temperament. Girls got higher score than boys in reactivity. The age 3 got higher score than the age 5 in activity and the ages 3, 4 got higher than the age 5 in total temperament. (2) Children's self-regulation were significantly different by their age. The children who were older got higher scores in self-regulation ability. (3) Children's problems behavior were significantly different by their gender and age. The boys got higher score than girls in anxiety behavior, aggressive behavior, hyperactive/distractive behavior, and total problem behavior. And the ages 3, 4 got higher score than the age 5 in anxiety behavior and hyperactive/distractive behavior. The age 4 got higher score the ages 3, 5 in aggressive behavior and the age 3 got higher score the ages 4, 5 in total problem behavior. (4) Canonical correlation results showed that stable temperament and self-regulation were positively correlated and self-regulation and problem behavior were negatively correlated.

Design of Wideband Electromagnetic Wave Absorber Using Magnetic Materials (자성재료를 이용한 광대역 전자파 흡수체 설계 연구)

  • Kim, Dong Young;Yoon, Seok Soo
    • Journal of the Korean Magnetics Society
    • /
    • 제22권6호
    • /
    • pp.210-215
    • /
    • 2012
  • The absorption performance of a metal-backed single layered electromagnetic wave absorber is optimized at matching conditions of thickness and frequency indicating the maximum returns loss of incidence electromagnetic wave in the contour map. These matching conditions are obtained by applying the electromagnetic impedance to the transmission line theory, which depend on the complex permeability and complex permittivity of absorber material. The magnetic materials with high permeability can enhance the matching thickness condition to the wide frequency range based on the decrease of permeability with frequency and it can be used as a wideband electromagnetic wave absorber material. Therefore, the magnetic materials with higher saturation magnetization and lower permittivity than NiZn ferrite can be applied to the wideband electromagnetic wave absorber in order to satisfy the newly enforcing the electromagnetic compatibility regulation in the future.

Serial MR Imaging of Magnetically Labeled Humen Umbilical Vein Endothelial Cells in Acute Renal Failure Rat Model (급성 신부전 쥐 모델에서 자기 표지된 인간 제대정맥 내피세포의 연속 자기공명영상)

  • Lee, Sun Joo;Lee, Sang Yong;Kang, Kyung Pyo;Kim, Won;Park, Sung Kwang
    • Investigative Magnetic Resonance Imaging
    • /
    • 제17권3호
    • /
    • pp.181-191
    • /
    • 2013
  • Purpose : To evaluate the usefulness of in vivo magnetic resonance (MR) imaging for tracking intravenously injected superparamagnetic iron oxide (SPIO)-labeled human umbilical vein endothelial cells (HUVECs) in an acute renal failure (ARF) rat model. Materials and Methods: HUVECs were labeled with SPIO and poly-L-lysine (PLL) complex. Relaxation rates at 1.5-T MR, cell viability, and labeling stability were assessed. HUVECs were injected into the tail vein of ARF rats (labeled cells in 10 rats, unlabeled cells in 2 rats). Follow-up serial $T2^*$-weighted gradient-echo MR imaging was performed at 1, 3, 5 and 7 days after injection, and the MR findings were compared with histologic findings. Results: There was an average of $98.4{\pm}2.4%$ Prussian blue stain-positive cells after labeling with SPIOPLL complex. Relaxation rates ($R2^*$) of all cultured HUVECs at day 3 and 5 were not markedly decreased compared with that at day 1. The stability of SPIO in HUVECs was maintained during the proliferation of HUVECs in culture media. In the presence of left unilateral renal artery ischemia, $T2^*$-weighted MR imaging performed 1 day after the intravenous injection of labeled HUVECs revealed a significant signal intensity (SI) loss exclusively in the left renal outer medulla regions, but not in the right kidney. The MR imaging findings at days 3, 5 and 7 after intravenous injection of HUVECs showed a SI loss in the outer medulla regions of the ischemically injured kidney, but the SI progressively recovered with time and the right kidney did not have a significant change in SI in the same period. Upon histologic analysis, the SI loss on MR images was correspondent to the presence of Prussian blue stained cells, primarily in the renal outer medulla. Conclusion: MR imaging appears to be useful for in vivo monitoring of intravenously injected SPIO-labeled HUVECs in an ischemically injured rat kidney.

Hypnotherapy for Warts : A Case Report (사마귀의 최면치료 1례)

  • Park, Hee-Gwan
    • Korean Journal of Psychosomatic Medicine
    • /
    • 제6권2호
    • /
    • pp.188-192
    • /
    • 1998
  • Brief hypnotherapy with daily self-hypnosis was used to a 20-year-old male patient who had severe warts on the fingers of both hands for 6 years. He had had several dermatological treatments, including attempts to remove the warts with topical chemotherapy, but the warts had always recurred. During the hypnotic session, it was suggested that the warts would begin to feel cool and disappear with imaginary laser. He responded well to ideosensory suggestions and was free of the warts within 5 sessions. Inquiry after 7 months revealed that no recurrence had taken place. Finally, it is stimulating to think that harmony between mind and body involving cell-mediated immunity can intervene in conditioning the course of the skin diseases.

  • PDF

Synthesis of Ultra Eine MnxZn1-xFe2O4(x = 0.69~0.74) Powder and Its Magnetic Properties (초미립 MnxZn1-xFe2O4(x = 0.69~0.74)분말의 제조 및 자기적 성질)

  • Kwak, Jae-Eun;Lee, Wan-Jae
    • Journal of Powder Materials
    • /
    • 제9권6호
    • /
    • pp.449-454
    • /
    • 2002
  • $MnxZn_{1-x}Fe_2O_4$ (x=0.69~0.74) powders synthesized by the thermal decomposition of organic acid salts. The obtained powders were uniform in composition and ultra-fine particle with about 400 nm. The amount of spinel phase of these powders was about 50% in X-ray diffraction patterns. The calcination of powder was carried out at $900^{\circ}C$ for 2 hours in air. After the powders were calcined. the mean size of powder was about 500 nm and the amount of spinel phase was increased over about 65%. The maximum amount of spinel phase was about 75% in the specimen of X=0.72. The magnetic properties of calcined $Mn_{0.72}Zn_{0.28}Fe_2O_4$ powders were the best among the different among the different compositions.

A New Technique or Dual $T_E$ Images Acquisition in Fast Spin Echo MR Imaging (고속 Spin Echo 자기 공명 영상법에서 두 가지 $T_E$ 영상을 얻기 위한 새로운 방법)

  • Cho, M.H.;Lee, S.Y.;Mun, C.W.;Cho, H.H.;Yi, W.
    • Proceedings of the KOSOMBE Conference
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.294-298
    • /
    • 1997
  • In the magnetic resonance imaging, the fast spin echo imaging technique is a widely used clinical imaging method, since its scanning time is much shorter than the conventional spin echo imaging and it gives the almost same image quality. However, the fast spin echo technique has two times longer imaging time or the dual echo acquisition which can obtain a spin density image and a $T_2$-weighted image simultaneously. To overcome such a drawback, this paper proposes a new fast dual echo imaging technique which can give the same quality images at the single echo imaging time. The proposed technique reduces the imaging time by overlapping most of echo train data for each image reconstruction. In order to verify its validity and usability the human head experimental results which were obtained at the 0.3T permanent MRI system are presented.

  • PDF