• Title/Summary/Keyword: 자기 완화

Search Result 246, Processing Time 0.029 seconds

Nuclear Magnetic Resonance Study of 23Na in NaMgCl3 Single Crystal (NaMgCl3 단결정 내의 23Na 원자핵에 대한 핵 자기 공명 연구)

  • Yeom, Tae Ho
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.6
    • /
    • pp.185-188
    • /
    • 2015
  • We have investigated nuclear magnetic resonance of $^{23}Na$ nucleus in $NaMgCl_3$ single crystal in the temperature range 200 K~410 K using FT-NMR spectrometer. The spin-lattice relaxation times $T_1$ of $^{23}Na$ nucleus residing at cubic symmetry in the host crystal was measured as a function of temperature. The $T_1$ of $^{23}Na$ nucleus decreased with increasing temperature. The nuclear spin-lattice relaxation rate $1/T_1$ of $^{23}Na$ in $NaMgCl_3$ single crystal was proportional to the temperature T. This behavior is explained with the characteristic feature of the direct process between the nuclear spins and single phonon, $1/T_1$ being proportional to the absolute temperature. The activation energy calculated was $E_a=4.82J/mol$.

Nuclear Magnetic Relaxation in Anisotropic Heisenberg Antiferromagnet $MnCl_{2}.4H_{2}O$ (Heisenberg 반강자성체 $MnCl_{2}.4H_{2}O$의 핵자기완화 연구)

  • Chang Hoon Lee;Cheol Eui Lee
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.1
    • /
    • pp.54-57
    • /
    • 1995
  • We have studied the room temperature $^{1}H$ nuclear magnetic relaxation in anisotropic antiferromagnet $MnCl_{2}.4H_{2}O$ using a wide range of $^{1}H$ NMR (nuclear magnetic resonance) field. Being a system of dense paramagnetic $Mn^{++}$ ions at room temperature, $MnCl_{2}.4H_{2}O$ shows some features that can be expected from dilute paramagnetic systems, as well as some results that drastically deviate from the dilute paramagnetic approximations. Besides, $^{1}H$ nuclei exhibit an anomalous deviation in the spin-lattice relaxation time ($T_{1}$) around the field of 0.7 T.

  • PDF

Parameter Estimation of Auto-Binomial Model using Selectionist Relaxation for Segmentation of Texture Images (유전자적 완화법에 의한 자기이항모형의 파라미터 추정과 질감 영상분할)

  • Lee, Seung-U;Kim, Hwang-Su;Park, Yeong-Cheol
    • Journal of KIISE:Software and Applications
    • /
    • v.28 no.3
    • /
    • pp.298-304
    • /
    • 2001
  • Markov 랜덤 필드(MRF)를 이용한 질감 영상의 영역분할을 각 영역을 기술해줄 수 있는 제대로 된 파라미터들을 찾는 것이 가장 중요하다. 종래에는 입력영상의 질감 영역의 수와 그 형태 등을 초기에 적당히 가정하여 파라미터를 찾는 방법을 써왔는데 실제 영상에는 잘 맞지 않았다. 최근에 완화법(Relaxation)을 이용하여 MRF의 파라미터를 찾는 방법이 제안[8]되었는데 오직 일반화된 Ising 모형에서만 사용가능 하였다. 본 논문에서는 비교적 자연영상에 적합한 자기이항 모형(Auto-binomial Model)에 변형된 완화법을 적용시켜 파라미터를 추정하고 질감 영상을 분할해 보았다. 그 결과 이전의 Ising 모형으로는 어려웠던 자연영산의 분할에서 좋은 결과를 얻을 수 있었다.

  • PDF

Magnetic Properties and Domain structures of Fe-based Amorphous Alloys with Magnetic Annealing (자장열처리시킨 Fe기 비정질합금의 자기적성질과 자구구조)

  • 김태호;정광호;송진태
    • Electrical & Electronic Materials
    • /
    • v.1 no.4
    • /
    • pp.319-332
    • /
    • 1988
  • 높은 포화자속밀도와 낮은 철손을 갖는 Fe/aub 80/B$_{12}$Si$_{8}$ 비정질합금을 일반열처리, 자장열처리시켜 그의 자기적특성과 자구구조와의 관계를 조사하였다. 이를 위하여 Fe$_{80}$B$_{12}$Si$_{8}$ 비정질리본을 단롤법으로 제작하여 결정화온도를 측정하였으며 측정된 결정화온도 이하의 여러 온도에서 30분간 Ar-gas 분위기하에서 일반열처리, 자장열처리를 행하였다. 이와같이 하여 준비된 시료의 자기적특성을 조사하기 위하여 D.C., A.C. Recorking Fluxmeter를 이용하였으며 자구구조는 Bitter method로 관찰하였다. as-cast 상태의 시료를 일반열처리함에 따라 내부응력이 완화되면서 maze자구가 점차 사라지고 wave형태의 180.deg.자구가 관찰되었다. 동시에 자화과정에 있어서 자기이력곡선은 Barkhausen jump가 없어 smooth하였다. 그리고 자장열처리시에는 as-cast 상태나 일반열처리에 비해 자기적특성이 현저하게 향상되었으며 이는 열처리를 행함에 따라 내부응력이 완화되면서 maze 자구가 없어지고 일축자기 이방성으로 리본길이방향에 평행하게 형성된 180.deg.자구에 기인하는 것이라 사료된다. 그리고 자장열처리의 경우, 폭방향으로 열처리한 리본의 자구폭은 길이방향으로 열처리한 리본의 폭보다 미세하였으며 전자의 이력손실이 후자의 것보다 더 컸다.다.

  • PDF

The Study of Vascular Dynamics for the Effect of a Compress Pack on Pain Relief using Magnetic Resonance Angiography (자기공명영상을 이용한 찜질 자극에 의한 통증 완화 효과에 대한 혈류 영상학적 고찰)

  • Baek, Ji-Won;Lim, Young-Khi
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.4
    • /
    • pp.277-282
    • /
    • 2015
  • This study was to investigate the effects of the hot compress pack on alleviating local muscular discomfort, stiffness in limbs as well as the chronic pains such as migraine in terms of hemodynamics. In this study, the hot compress band was put on the neck and the local physiological change on the stimulation site and the cranial blood circulation change were examined. We recruited healthy volunteers (n=8, mean age: 32.13 (4.61)), who participated in the magnetic resonance imaging (MRI) study. Local skin color and temperature were measured for the local effect of the hot compress band and the changes of intra-cranial and extra-cranial blood vessels were examined with MR angiography (MRA) images. The skin temperature increased from $36.4^{\circ}C$ at the rest condition to $36.7^{\circ}C$ and $37.1^{\circ}C$ after 15 min and 30 min stimulation, respectively. The change of the extra-cranial blood vessels between pre-stimulation and post-stimulation of 30 min was significantly increased (+38.8%), while the change of the intra-cranial blood vessels was negligible. In this study, we demonstrated that the hot compress band on the neck yielded the increase of local skin temperature on the stimulation site and it made an effect on the extracranial circulation. In conclusion, the stimulation with a hot compress could facilitate the blood circulation, causing to relieve the muscular discomfort, stiffness in limbs as well as the chronic pains such as migraine.

Determination of the Magnetic Moment of ${\alpha}-Fe_{2}O_{3}$ of the Parasitic Ferromagnetism by the Proton Relaxation in Water (물의 양성자완화에 의한 기생 강자성 ${\alpha}-Fe_{2}O_{3}$의 자기능률 결정)

  • Yong-Jin Kim;Jung-Gi Kim
    • Journal of the Korean Magnetics Society
    • /
    • v.4 no.3
    • /
    • pp.282-284
    • /
    • 1994
  • A theoretical expression for determining the effective magnetic moment of hematite(${\alpha}-Fe_{2}O_{3}$) particle of the parasitic ferromagnetism by the proton relaxation in water is derived. In deriving the expression it is found that the mathematical procedures are exactly the same as those applied for aqueous solutions containing free paramagnetic ions, except that the distance between the proton spin of water molecule and the corresponding electronic spin of the particle must be considered to be a radius vector rather than a relative distance. And it is also found that the average effective magnetic moment of the particle calculated by the expression is in good agreement with the experimental value determined by Hirai.

  • PDF

Parametric Study of Curved Guideways for Urban Maglev Vehicle (도시형 자기부상열차의 곡선 가이드웨이 매개변수 연구)

  • Han, Jong-Boo;Kim, Ki-Jung;Han, Hyung-Suk;Kim, Sung-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.3
    • /
    • pp.329-335
    • /
    • 2014
  • A maglev vehicle of middle-low speed subjected to both a lift force and a guidance force by a U-shaped single electromagnet is operated over a curved guideway without a guidance controller. Therefore, it is required to carefully decide the curve shape for preventing contact between the vehicle and the guiderail for the case that a Maglev vehicle is operated over a curved guideway with a small radius. Specifically, the shape of the transition curve is very important from the stability viewpoint. This study analyzes the influence of curve shape on maglev stability through parametric composition of the transition curve during vehicle guidance. To this end, a multibody dynamics-based threedimensional Maglev vehicle model was developed. The model was integrated with the vehicle, curved guideway, electromagnets, and their controllers. Using this model, a realistic parametric study including the curved guideway was carried out. The results of research should be considered usefully in the design of bogies and the curve shape.

AC Voltage and Frequency Dependence in Tunneling Magnetoresistance Device (터널링 자기저항 소자의 교류 전압 및 주파수 의존성 연구)

  • Bae, Seong-Cheol;Yoon, Seok Soo;Kim, Dong Young
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.6
    • /
    • pp.201-205
    • /
    • 2016
  • In this report, we measured the impedance spectrum in TMR device, and the relaxation behavior of the real and imaginary impedance spectrum was analyzed by using the equilibrant circuit of tunneling capacitance ($C_T$) and tunneling resistance ($R_T$). The relaxation frequency was increased with AC voltage in both the parallel and antiparallel alignment of two magnetic layers. The $R_T$ with AC voltage showed the typical bias voltage dependence. However, the $C_T$ showed large value than the expected geometrical capacitance. The huge increase of $C_T$ was affecting as a limiting factor for the high speed operation of TMR devices. Thus, the supercapacitance of $C_T$ should be considered to design the high speed TMR devices.

Proton and Deuteron Spin-Lattice Relaxation in Gaseous HD (HD 기체에서의 수소 및 중수소 원자핵 스핀-격자 완화시간에 관한 핵자기공명 연구)

  • ;R. E. Norberg
    • Journal of the Korean Magnetics Society
    • /
    • v.4 no.1
    • /
    • pp.52-55
    • /
    • 1994
  • The proton and deuteron spin-lattice relaxation times, $T_{1}(H)$ and $T_{1}(D)$, have been measured in HD between 30 K and 313 K in the pressure of 0.67 - 1.92 atm. The nuclear magnetic resonance frequencies are respectively 358.012 MHz for a proton and 58.958 MHz for a deuteron. From the measurements of $T_{1}(H)$ and $T_{1}(D)$ the ratio of the correlation times ${\tau}_{1}\;and\;{\tau}_{2}$ that are associated with the molecular angular momentum operators was obtained. The nuclear spin-lattice relaxation time at J = 1 state has been observed to have a temperature dependence being proportional to $T^{0.25}$.

  • PDF