• Title/Summary/Keyword: 자기 서스펜션

Search Result 23, Processing Time 0.018 seconds

Magnetic Circuit Design Methodology of MR CDC Dampers for Semi-Active Suspensions (반능동 서스펜션용 MR CDC 댐퍼의 자기회로 설계기법)

  • Park, Jae-Woo;Jung, Young-Dae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.10
    • /
    • pp.48-57
    • /
    • 2008
  • MR Fluid, one of functional fluids, is developed for the application to automobile products. MR CDC damper using MR fluid has following principles. When ar electric current is applied to the solenoid, apparent viscosity of MR fluid passing through the annular gap which acts as magnetic circuits varies directly as the intensity of the current. These devices have a simple structure and excellent lime response characteristics, emerging as the alternatives of the conventional semi-active suspension systems. In this study, a design procedure of the magnetic circuit through the solenoid fore and the flux ring functioning as a magnetic path is investigated so as to optimize the design and performance of MR CDC dampers for the vehicles. In addition, an operating point on the B-H curve, the magnetization according to the variation in the annular gap, the pole piece width and the density of MR fluid are studied to design the optimal piston head within the restrained dimension range.

Importance of Impregnation and Polishing for Backscattered Electron Image Analysis for Cementitious Self-Healing Specimen (시멘트계 자기치유 시편에 대한 반사전자현미경 이미지 분석을 위한 함침과 연마의 중요성)

  • Kim, Dong-Hyun;Kang, Kook-Hee;Bae, Seung-Muk;Lim, Young-Jin;Lee, Seung-Heun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.4
    • /
    • pp.435-441
    • /
    • 2017
  • Studies on self-healing have currently been diversified and the methods to evaluate the studies have become more diversified as well. Among them, the back-scattered electron (BSE) image acquired through the scanning electron microscope (SEM) is attempted as the means to evaluate the self-healing effect on cracks. In order evaluate by the BSE image, sophisticated pre-processing of specimen is critical and this injected inside the particle, pore and artificial crack of the hardener to stabilize the structure of the newly generated self-healing product and it enables to endure the stress on polishing without deformation. The impregnated specimen smoothen the surface to obtain the BSE image of high resolution that polishing is made for diamond suspension for wet polishing after dry polishing. As a result of evaluating the self-healing product on the impregnated and polished self-healing specimen, the generated product is formed from the surface of the artificial crack and the self-healing substances are confirmed as $Ca(OH)_2$ and C-S-H.

The Magnetic Relaxation Properties of DTPA-bis(4-carboxycyclohexyl) amide Paramagnetic Gd-chelates (DTPA-bis(4-carboxycyclohexyl)amide 상자성 복합체의 자기이완특성에 관한 연구)

  • Kim, In-Sung;Lee, Young-Ju;Lee, Jae-Jun;Kim, Ju-Hyun;Kim, Yoo-Kyung;Sujit, Dutta;Kim, Suk-Kyung;Kim, Tae-Jeong;Kang, Duk-Sik;Chang, Yong-Min
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.1
    • /
    • pp.20-25
    • /
    • 2006
  • Purpose : To evaluate the NMR relaxation properties of newly developed high performance paramagnetic complexes. Materials and methods : 4-aminomethylcyclohexane carboxylic acid (0.63g, 4 mmol) was mixed with the suspension solution of DMF (15mL) and DTPA-bis-anhydride (0.71g, 2 mmol) to synthesize the ligand. The ligand was then mixed with Gd2O3 (0.18g, 0.5 mmol) to synthesize Gd-chelate. For the measurement of magnetic relaxivity of paramagnetic compounds, the compounds were diluted to 1mM and then the relaxation times were measured at 1.5T(64 MHz). Inversion-recovery pulse sequence was employed for T1 relaxation measurement and CPMG(Carr-Purcell-Meiboon-Gill) pulse sequence was employed for T2 relaxation measurement. Using MATLAB(Version 7.1) program, T1 magnetic relaxation map, R1 map, T2 magnetic relaxation map and R2 map were developed to represent magnetic relaxation time and magnetic relaxivity as image. Results : Compared to $R1=4.9mM^{-1}sec^{-1}$ and $R2=4.8mM^{-1}sec^{-1}$ of Omniscan (Gadodiamide), which is commercially available paramagnetic MR agent, R1 of SUK090(Gd-C32H74N5O24) was $12.46mM^{-1}sec^{-1}$ and R1 of SUK091(Gd-C34H78N5O24) was $12.77mM^{-1}sec^{-1}$. However, R1 of SUK092(Gd-C30H56N5O17) was decreased to $2.09mM^{-1}sec^{-1}$. In case of R2, SUK090(Gd-C32H74N5O24) was $8.76mM^{-1}sec^{-1}$ and SUK091(Gd-C34H78N5O24) was $7.60mM^{-}1sec^{-1}$ whereas SUK092(Gd-C30H56N5O17) was decreased to $1.82mM^{-1}sec^{-1}$. Conclusion : Among three new paramagnetic complexes, SUK090(Gd-C32H74N5O24) and SUK091(Gd-C34H78N5O24) showed higher T1, T2 magnetic relaxation rates than that of commercially available paramagnetic MR agent and thus expected to have more contrast enhancement effect.

  • PDF