• Title/Summary/Keyword: 자기포화도

Search Result 446, Processing Time 0.023 seconds

Annealing Effects of Amorphous Cores for the Application of Flux-gate Sensors (Flux-gate 센서용 비정질 코아의 열처리효과)

  • 김용준;손대락;손동환
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.3
    • /
    • pp.134-140
    • /
    • 2001
  • Flux-gate magnetometer was developed in 1930's, and it has been widely used for the low magnetic field measurements. In this work, we have employed amorphous ribbon 2714A produced by Allied Chem. Co. as sensor core material. To develop low noise, low power consumption, and high reliability flux-gate magnetometer, we have measured ac magnetic properties depending on the annealing conditions. As quenched state amorphous core shows high noise level and ac magnetic properties were changed under the condition of accelerated aging test, but amorphous ribbon, which was annealed under 350 $\^{C}$ during 1 hour, shows low noise level of 0.1 nT in the frequency range of dc∼10 Hz which was 10 times better than the as quenched amorphous ribbon. Under accelerated aging test, ac magnetic properties such as squareness and coercivity of the annealed samples show higher reliability and approached to a certain limiting value as exponential function. We can see that high reliability and low noise flux-gate magnetometer could be developed, if we consider this ac magnetic properties change in the sensor design.

  • PDF

Study for Development of Nondestructive Inspection Device in Natural Gas Pipeline Using MFL Technology (MFL을 이용한 천연가스 배관용 비파괴 검사장비 개발에 관한 연구)

  • Cho S.H.;Kim D.K.;Park D.J.;Park S.S.;Yoo H.R.;Koo S.J.;Rho Y.W.;Kho Y.T.
    • Journal of the Korean Institute of Gas
    • /
    • v.6 no.1 s.17
    • /
    • pp.10-16
    • /
    • 2002
  • This paper introduces developed prototype intelligent pig which detects corrosion on pipeline by using Magnetic Flux Leakage technology. The 8 inch developed MFL(Magnetic Flux Leakage) pig is composed of 5 yokes which magnetize pipeline wall and 45 Hall sensors which detect MFL signal. The designed MFL modules are analyzed by using magnetic circuit method in order to confirm whether pipeline wall is fully saturated. A variety of artificial defects are manufactured on 8 inch diameter steel pipeline in order to acquire MFL signals. So leakage flux of the axial, radial and circumferential component was acquired as defects. The results of this paper show that design technique for 8 inch MFL pig can be applied to large diameter MFL pig and 0.5mm defect depth can be detected.

  • PDF

The Magnetism and Electronic Structures of Ru Monolayer with Square Lattice (사각형구조를 갖는 Ru 단층의 자성과 전자구조)

  • 조이현;김인기;이재일;장영록;박인호;최성을;권명회
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.3
    • /
    • pp.127-130
    • /
    • 1999
  • The magnetism and electronic structure of Ru monolayer with square lattice is investigated using the FLAPW band method. The dependence of total energies on the lattice constant was calculated for three magnetic states, i.e.,para-,ferro-, and antiferromagnetic ones. It was found that there is no energy difference between para-and antiferromagnetic states for all the lattice constant. The possibility of antiferromagnetism in square Ru monolayer is thus excluded. The ferromagnetic state is most stable for the lattice constants greater than 7.30 a.u. The energy minimum is found at the lattice constant of 6.53 a.u. Where it is paramagenetic. It is calculated that the magenetic moment is 2.49 ${\MU}_B$ at 7.72 a.u., which is close to the lattice constant of Ag. The magnetic moment is almost saturated to be ${\MU}_B$ at the lattice constant of 7.86 a.u.

  • PDF

Nitrogenation Process and Magnetic Properties of $Sm_{2}Fe_{17}$-Nitride ($Sm_{2}Fe_{17}N_{x}$의 질화과정 및 자기특성)

  • 김동환;권혁무;김택기;김희태;김윤배
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.858-863
    • /
    • 1995
  • The nitrogenation process and magnetic properties of $Sm_{2}Fe_{17}N_{x}\;(0{\leq}x{\leq}3)$ were investigated. During the initial nitrogenation process, the nitrogen content had linear relation with the square root of nitrogenation time, and the activation energy for the process was calculated to be 102.4 kJ/mol. The magnetic properties of $Sm_{2}Fe_{17}N_{x}$ were strongly dependent on the nitrogen content and the composition having $Sm_{2}Fe_{17}N_{2.8}$ showed optimum magnetic properties with a Curie temperature of 450 oC. The intrinsic magnetic properties of the nitride at room temperature were $M_{s}=1147\;emu/cm^{3},\;K_{1}=4.6{\times}10^{7}erg/cm^{3},\;K_{2}=6.0{\times}10^{7}erg/cm^{3}\;and\;H_{A}=290\;kOe$, respectively.

  • PDF

The Magnetic Properties and Microstrostrures for FeMX(M=Mo, Ta, X=N, C) Films. (FeMX(M=Mo, Ta, X=N, C) 박막의 자기 특성 및 미세구조 변화)

  • Shin, D.H.;Choi, W.;Kim, H.J.;Nam, S.Y.;Ahn, D.H.
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.874-879
    • /
    • 1995
  • Magnetic properties of FeMoN, FeMoTaN, FeTaN and FeTaC films deposited by DC magnetron reactive sputter were investigated, and correlated with their microstructure. FeMoN films were not showen the soft magnetic prop¬erties, because of generated $Fe_{2}Mo$, $Fe_{3-2}N$ and $Fe_{4}N$ phases. Ta added films, however, effectivly retarded the $\alpha$-Fe grain growth and suppressed the generation of Fe nitrides or carbides during heat treatement. The soft magnetic properties of $B_{s}:15\;kG,\;H_{e}:0.25\;Oe,\;\mu':4000(at\;5\;MHz),\;and\;B_s:14.5\;kG,\;He:0.25\;Oe,\;\mu':2700(5MHz)$ were observed in $Fe_{78.8} Ta_{8.5}N_{12.7}\;and\;Fe{75.6}Ta_{8.1}C_{16.3}$ films, respectively.

  • PDF

Initial Rotor Position Estimation for an Interior Permanent-Magnet Synchronous Motor using Inductance Saturation (인덕턴스의 포화현상을 이용한 IPMSM의 회전자 초기 위치 추정)

  • Park, Nae-Chun;Lee, Yoon-Kyu;Kim, Sang-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.374-381
    • /
    • 2011
  • This paper proposes a new method to acquire an initial rotor position for IPMSM(Interior Permanent Magnet Synchronous Motor) without a position sensor at standstill. The proposed method is based on the variation of inductance caused by the magnetic saturation of stator core. Minimum number of voltage vectors are chosen to determine the initial rotor position. By using the resultant currents in combination with the inductance variation, the north pole and the absolute position of the rotor can be easily obtained. This method also has the advantage of not requiring motor parameters and additional hardware. Its validity is verified by experiments.

Magnetic Properties of FeZrN/$SiO_2$ Soft Magnetic Multilayer Thin Films (FeZrN/$SiO_2$ 연자성 다층 박막의 자기적 성질)

  • Kim, Taek-Su;Kim, Jong-O
    • Korean Journal of Materials Research
    • /
    • v.6 no.11
    • /
    • pp.1061-1066
    • /
    • 1996
  • RF magnetron reactive sputtering법으로 Fe75.5Zr8.3N16.2/SiO2(250$\AA$) 다층 박막을 FeZrN의 두께를 변화시키면서 제조하고, 제조된 박막을 진공 열처리하여 열처리 온도에 따른 포화자화, 보자력, 고주파에서의 투자율 그리고 열적 안정성을 조사하였다. Fe75.5Zr8.3N16.2/SiO2(250$\AA$) 다층박막은 FeZrN의 두께가 800$\AA$이상일 때 좋은 연자성을 나타내었다. Fe75.5Zr8.3N16.2/SiO2(250$\AA$)다층 박막을 45$0^{\circ}C$로 열처리 했을 때 포화자속밀도(1.08 T), 보자력 0.41 Oe, 1 MHz에서의 실효 투자율은 3000이상의 연자성을 나타내었다. 그 이유는 X-선 회절 분석 결과 열처리에 의해서 ZrN 미결정이 석출하여 $\alpha$-Fe 결정 성장이 억제되어 우수한 연자기적 성질이 나타난다고 판단된다. 이때 $\alpha$-Fe 입자 크기는 40-50$\AA$, ZrN의 입자 크기는 10-15$\AA$이다. 그리고 실효 투자율의 주파수 의존성에서 단층막에서는 5 MHz 이상에서 실효 투자율이 급격히 감소하는 경향을 보였으나, 다층막에서는 40MHz까지 실효 투자율이 1600이 되어 고주파에서의 연자성이 개선되었다.

  • PDF

Standstill Identification of Magnetic Flux Saturation Model Including Cross-Saturation for Synchronous Motors (상호 포화를 포함한 자기저항 동기 전동기의 자속 포화 모델에 대한 정지 상태 추정 기법)

  • Woo, Tae-gyeom;Park, Sang-woo;Choi, Seung-Cheol;Yoon, Young-Doo;Lee, Hak-Jun;Hong, Chanook;Lee, Jeongjoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.5
    • /
    • pp.364-371
    • /
    • 2021
  • A magnetic flux saturation model of Synchronous Reluctance Motors (SynRMs) and a parameter estimation method are proposed at standstill. The proposed magnetic flux model includes the nonlinear relationship between the current and the magnetic flux for self-saturation and cross-saturation. Voltage is injected at standstill to estimate the magnetic flux saturation model. Voltages are injected into the d-axis and q-axis to obtain data on self-saturation. Subsequently, voltages are simultaneously injected into the d-q axis to obtain data on cross-saturation. On the basis of the measured current and the calculated magnetic flux, the parameters of the proposed model are estimated using the least square method (LSM). Simulation and experiment were performed on a 1.5-kW SynRM to verify the proposed method. The proposed model can be used to create a high-efficiency operation table, a sensorless algorithm, and a current controller to improve the control performance of a motor.

Estimation of Fluid Saturations Using Agarose Standard in NMR Imaging (자기 공명 영상법에서 Agarose 표준 물질을 사용한 유체 포화도의 계산)

  • Kim, Kyung-Hoe
    • Applied Chemistry for Engineering
    • /
    • v.10 no.1
    • /
    • pp.160-165
    • /
    • 1999
  • Agarose gels can be used as reference standards for the measurement of fluid properties in porous media because the relaxation properties of the gel reference standard and those of the fluid in porous media can be closely matched. The use of reference standard to determine porosity and saturation is discussed and the requirements for gel NMR properties given. The relaxtion times of agarose gels measured at 2.0 Tesla are illustrated as a function of agarose and paramagnetic impurity ($CuSO_4$) concentrations. This work shows an empirical result between agarose gel composition and gel relaxtion times. The average value for the porosity distribution is 17.7%, which compares well with the value calculated with the gravimetric analysis. Finally, two phase immiscible displacement using agarose gels as a reference standard was performed. The saturation profiles appear to be consistent with what one might calculate for a one-dimensional displacement in a uniform porous media.

  • PDF

Improvement of Fourier Transform Arteriography by Use of Ramped RF Profile and Dual Projections (경사 윤곽의 고주파 펄스와 이중 투사법에 의한 Fourier 변환 동맥 혈관 촬영법의 성능 향상)

  • Jung, K. J.;Kim, I. Y.;Lee, M. W.;Yi, Y.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.41-46
    • /
    • 2002
  • The Fourier transform arteriography (FTA) exploits the periodic variation of arterial flow velociety of arterial flow velocity in stnchronized with cardiac cycles. This technique is intrinsically unique compared to other modern techniques. This technique separates the arteries from the veins using the pulsatile arterial flow without using the presaturation RF pulses. Therefore, it has less RF deposition and is free from the dark band artifacts that can arise from retrograde flow and curved arteries. Furthermore, it is free from the artifacts induced by eddy currents. However, there are some drawbacks such as a single projection view and the saturation of arteries at the end of an imaging slab. These drawbacks are circumvented by applying recently developed techniques. The fast gradient switching capability of modern MRI systems enabled us to incorporate dual projection views into the conventional FTA sequence without increasing the repetition time. In addition, signals from the distal arteries were enhanced by use of a ramped RF pulse and therefore the distal arteries were less saturated. By use of the FTA sequence with dual projection views and the ramped RF pulse, we acquired the sagittal and coronal projection views of femoral arteriograms simultaneously with more enhanced signals of distal arteries than the conventional FTA.

  • PDF