• Title/Summary/Keyword: 자기장 측정

Search Result 534, Processing Time 0.023 seconds

Assessment of subjective symptoms by 60Hz magnetic field in electromagnetic hypersensitivity (60Hz 자기장에 대한 과민 증후군의 자각증상 원인 평가)

  • Yang, Dong-In;Nam, Ki-Chang;Kwon, Min-Kyung;Kim, Deok-Won
    • Science of Emotion and Sensibility
    • /
    • v.13 no.4
    • /
    • pp.721-732
    • /
    • 2010
  • As increasing of electrical device usage, social concerns about the possible effects of 60Hz electromagnetic fields (EMF) on human health have increased. The number of people with self-attributed electromagnetic hypersensitivity (EHS) who complain of subjective symptoms such as headache, insomnia etc. also increased. However, we don't know whether the EHS results from psychological factor or real perception to the electromagnetic field. In this study, we simultaneously investigated physiological changes(heart rate, respiration rate, heart rate variability, alpha and beta waves in EEG), subjective symptoms and perception accuracy to assess origins of subjective symptoms according to the EMF exposure. Experiment consists of real and sham sessions and 60Hz 12.5uT magnetic field was on(real) or off(sham) to 15 EHS and 16 nonEHS. As the results, EMF exposure did not have any effects on physiological parameters or subjective symptoms for both groups. There was also no evidence that EHS group perceived the EMFs correctly than the control group. Therefore, the origins of subjective symptoms is not the 60Hz magnetic field but psychological factors.

  • PDF

Design of MSR for Magnetic Field Shielding of Low Frequency (저주파 자기장 차폐를 위한 자기차폐실 설계)

  • Choi, Hak-Yun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.154-159
    • /
    • 2010
  • In this paper, the magnetically shielded room for low magnetic field shielding is designed and measured by fabricated. The size of magnetically shielded room was 3.0[m](W)$\times$3.0[m](L)$\times$3.0[m](H) to enter the industrial measuring instruments and analyzed DC and AC shielding characteristics of magnetic materials with a high permeability and AC shielding characteristics by eddy current of conductive materials. As a results, shielded room dimensions were obtained. To verify the analysis results, magnetically shielded room is fabricated and the calculated results are compared with the measured results. The Measured results show good agreement with calculated results. According to measurements, 5 times of 0.1[Hz] and 86 times of 60[Hz] is achieved at low frequency. The fabricated shielding room can be used as the magnetically shielding room for low magnetic field shielding.

Construction of a Low Magnetic Field Standard System Using a Precision Solenoid (정밀솔레노이드를 사용한 저자장 표준시스템 제작)

  • 박포규;손대락;우병칠;김창석
    • Journal of the Korean Magnetics Society
    • /
    • v.2 no.2
    • /
    • pp.150-155
    • /
    • 1992
  • The low magnetic field standard below 1 mT with resolution of 100 nT has been established for the calibration and testing of low field magnetometers. A precision single layered solenoid, which is made of quartz tube and bare copper wire, was constructed in order to generate a precise magnetic field. To improve the field homogeneity in the solenoid, three-current method was employed. The injected current and injection points on the solenoid were optimized by computer simulation. The magnetic field uncertainty in the solenoid was 0.1 % and 0.01 % in the range of ${\pm}5\;cm$ from the center for a single and three-current methods respectively. We also constructed a testing system for the dynamic properties of low field magnetometers.

  • PDF

Response Properties of Meridians for focused variable electromagnetic stimulus (접속형 가변 전자계 자극에 대한 경락반응특성)

  • Lee, Gyoun-Jung;Cho, Dong-Guk;Kim, Soo-Byung;Kwon, Sun-Min;Shin, Tae-Min;Lee, Kyoung-Joung;Lee, Yong-Heum
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.7
    • /
    • pp.1399-1410
    • /
    • 2009
  • It is a method to treat pain using medication, neurotomy, and surgery. And acupuncture, ultrasound, electric treatment, and magnetic treatment are applied as a alternative physiotherapy. Electronic therapy is useful but it can be affected by impedance of skin or subcutaneous tissue. So, percutaneous stimulation is leading therapy, that is very randomly. We developed the system which can stimulate parts of acupuncture point noninvasively using the focused magnetic field. And we designed the magnetic stimulation electrode which is considered efficiency of the magnetic stimulation. It can make similar stimulation with manual acupuncture. To confirm the availability and reliability we compared Meridian Electronic Potential(MEP) change between manual acupuncture and magnetic stimulation. From this result, we found out the MEP changes of manual acupuncture and magnetic stimulation were similar. And there were various response properties as changes of stimulation method, intensity, and frequency. Also, the MEP change can be induced by electromagnetic stimulation. We confirmed that it is possible to use electromagnetic stimulation as a acupoint stimulation or pain treatment instrument.

Study on NMR Measurment of Flowing Water by a Separated Detector (분리형 감지기를 이용한 흐르는 물의 핵자기공명 측정연구)

  • ;;;;V. Ya. Shifrin
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.3
    • /
    • pp.165-170
    • /
    • 1995
  • NMR measurement has been studied for protons in pre-polarized flowing water by a separated detector working at high field far away from the measured field region where the transition of protons is occurred by the pertur-bation of RF energy. The conditions for NMR signal were optimized on the amplitude and frequency of modulation field, the RF field of detector, water speed, and RF field at the measured field region. The NMR signal with the full width of 320 nT at the half maximum in Lorentzian curve and with signal to noise ratio of 10.5 was measured in the range from a few ${\mu}T$ to mT, and its shape and amplitude were independent of the measured field intensity and its uniformity.

  • PDF

Magnetic Hysteresis Curve Tracer using Pulsed Electromagnet (펄스전자석에 의한 자기이력곡선측정기)

  • 이용호;신용돌;이영희;이장로
    • Journal of the Korean Magnetics Society
    • /
    • v.3 no.2
    • /
    • pp.121-124
    • /
    • 1993
  • 보자력이 큰 강자성체의 자기이력곡선, 자기변형, 자기이방성등의 측정에 사용할수 있는 펄스전자석을 설계제작하였다. 철심의 형상이 주어졌을때 권선의 회수에 따른 전자석의 여러특성과 축전기 방전시의 전류진폭 감쇄비등을 계산하는 일반식을 유도하고 그것에 의하여 철심단면적 46 nm * 32 nm, 공기간격 28nm의 전자석을 설계 제작하여 20 mT/A의 기울기로 0.49 T까지 직선적인 자기장 대 전류특성을 얻었다. 이 전자석에 에너로그 적분기에 의한 자속계를 부쳐서 박막 또는 박대시료의 major 및 minor 이력곡선을 단번에 쉽게 얻을 수 있는 자기이력곡선 측정기가 구성되었다.

  • PDF

ATTITUDE CONTROL OF SMALL SCIENTIFIC SATELLITE USING GEOMAGNETISM (지구자기장을 이용한 소형과학위성의 자세조정)

  • 배성구;석재호;최규홍
    • Journal of Astronomy and Space Sciences
    • /
    • v.8 no.1
    • /
    • pp.85-98
    • /
    • 1991
  • Geomagnetism was used to control the attitude of the small scientific satellite at low altitude in sun-synchronous orbit. First, we analyzed the telemetry data. The rotation state of the satellite, can be known from the magnitude and variations of the magnetic field which is measured from the 3 axis magnetometer. In axisymmetric case, it is possible to control the attitude of the satellite by changing the rotation velocity of each 3 axis. The algorithm and the program were developed to calculate the supply time of the current operating the magnetorquer. This attitude control can be applied when the satellite is in tumbling motion and after passive control is attained by the Gravity gradient boom.

  • PDF

Design and Fabrication of EMAT for Excitation of SAW (SAW 여기를 위한 EMAT의 설계 및 제작에 관한 연구)

  • Kim, Heung-Ki;Lee, Jae-Seung;Jun, Kye-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.9 no.3
    • /
    • pp.24-30
    • /
    • 1990
  • In this paper, meander line type EMAT(Electro-Magnetic Acoustic Transducer) has been designed and fabricated with effective properties for detecting flaw existing within one wavelength in depth, and its characteristics have been analyzed. For the purpose of getting effective dynamic and static magnetic intensity, the coil has been arrayed using wire with interval of 0.75 mm and width of 0.65 mm and permanent magnets with 1500 Gauss have been constructed respectively. The center frequency and fractional bandwidth of the fabricated EMAT was 2 MHz and 36% respectively and its impulse response has been measured by non-contacting technique(the distance between the conducting media and the coil was 0.15mm). In the measuring results, it has been shown that Insertion Loss(IL) was 45.46dB and it was good agreement with theoretical result.

  • PDF