• Title/Summary/Keyword: 자기장 자극

Search Result 54, Processing Time 0.029 seconds

The Change of Cortical Activity Induced by Visual Disgust Stimulus (시각혐오자극으로 유발된 대뇌 피질 활성도 변화)

  • Jung, Wook;Park, Doo-Heum;Yu, Jae-Hak;Ryu, Seung-Ho;Ha, Ji-Hyeon;Shin, Byoung-Hak
    • Sleep Medicine and Psychophysiology
    • /
    • v.20 no.2
    • /
    • pp.75-81
    • /
    • 2013
  • Objectives: There are a lot of studies that analyze the interaction between the emotion of disgust and the functional brain images using fMRI and PET. But studies using sLORETA (standardized low resolution brain electromagnetic tomography) almost do not exist. The aim of this research is to explore the relationship of the emotion of disgust and the cortical activation using sLORETA analysis. Methods: Forty five healthy young adults ($27.1{\pm}2.6$ years) participated in the study. While they were watching 4 neutral images and 4 disgusting images associated with mutilation selected from the international affective picture system (IAPS), participants' EEGs were taken for 30 seconds per one picture. Through these obtained EEG data, sLORETA analysis was performed to compare EEGs associated with neutral and negative images. Results: During looking for visual disgusting stimulus, all participants reported unpleasantness, arousal and stress. In sLORETA analysis, the decrease of current density in theta wave was shown at left frontal superior gyrus (BA10) and middle gyrus (BA10, 11). This voxel cluster consists of a total of 11 voxels and the threshold of t value indicating statistically significant decreases in the current density (p<0.05) was -1.984. There were no differences between male and female in the degree of being disgusted by the stimuli. Conclusion: This finding may suggest that the activation of dorsolateral prefrontal cortex might be associated with regulating disgust emotion.

Emotional experiences of baseball fans at winning and losing games: An fMRI approach (경기 승패에 따른 야구팬들의 정서경험: fMRI연구)

  • Park, Hye-Ju;Yoo, Ho-Sang
    • Korean Journal of Cognitive Science
    • /
    • v.21 no.3
    • /
    • pp.429-446
    • /
    • 2010
  • This study is to examine if emotional valance depending upon the result of baseball game(losing or winning) of subjects' favorite team yields hemispheric asymmetry measured by fMRI. Subjects were twelve fans of the Samsung Lions baseball team. The brain activations have been observed while they watched winning and losing scenes of their favorite team. As a results of the experiment, those who watched winning scenes showed the activation of the left and right cuneus, right inferior occipital gyrus, right inferior frontal gyrus, left amygdala, right parahippocampal gyrus, left uncus, left cingulate gyrus, left inferior temporal gyrus, right middle temporal gyrus, left declive, left culmen. On the contrary, those who watched losing scenes showed the activation in the right middle frontal gyrus, left anterior cingulate, left sub-gyral, left lentifomrm nucleus, left thalamus, left claustrum, left insula. The evidence of hemispheric asymmetry from this study has not been demonstrated and activation in amygdala observed during watching winning scene has not been observed in losing scene. Therefore more in-dept research is required about defeat stimuli induction.

  • PDF

Effect of Aroma Therapy on Speech Anxiety in Children (아로마 처치가 초등학생의 발표불안에 미치는 영향)

  • 손진훈;이영순;장은혜;이창규;석지아
    • Science of Emotion and Sensibility
    • /
    • v.7 no.2
    • /
    • pp.187-194
    • /
    • 2004
  • This study is to investigate whether or not the aroma treatment has a positive impact on the reduction of anxiety of the school children when presenting a speech. Participants were 70 school children(20 males and 15 females for the control group, and 21 male and 14 females in the experimental group). They were exposed to 4 different scents i.e., lavender barreme, lemon, orange sweet, chamomile roman that were vaporized through humidifiers. Pre and post self-report type of SAS done by the children and SBES done by teachers were done before and one and two weeks after the treatment. The result indicated that children with aroma treatment than children who had no treatment showed a significant decrease in speech anxiety and improvement in behavior during speech.

  • PDF

Evaluation of Clinical Usefulness of Radio-Frequency Power Limitation in Brain MRI of Patients with Deep Brain Stimulation (뇌심부자극술 시술환자의 뇌 자기공명영상에서 고주파 출력의 제한기준에 대한 임상적 유용성 평가)

  • Yeon, Kyoo-Jin;Chang, Young-Ae;Lee, Seung-Keun;Lee, Tae-Soo
    • Journal of Radiation Industry
    • /
    • v.11 no.3
    • /
    • pp.139-144
    • /
    • 2017
  • To evaluation of clinical usefulness for B1+RMS limits, we compared image quality of Routine, Specific absorption rate (SAR) and Root mean square (RMS) protocol. 5 volunteers underwent Magnetic Resonance Imaging (MRI) scan of the brain using three different protocols. We draw Region of interest ROI in cortex, white matter, gray matter, putamen and thalamus of axial plan. Signal to noise ratio (SNR) were evaluated in each area and Contrast to noise ration (CNR) were evaluated between white matter and gray matter. Qualitative evaluation was used to score each ROI. B1+RMS is confirmed its usefulness compared to conventional SAR standard on the aspect of improvement of image quality, reduction of scan time and easy adjusting parameter.

Neural responses to sonic branding : an fMRI study (소닉 브랜딩에 대한 신경 반응 : fMRI 연구)

  • Sung, Young-Shin;Choi, Min-Jo;Chung, Sun-Joo;Kim, Chai-Youn
    • Science of Emotion and Sensibility
    • /
    • v.14 no.1
    • /
    • pp.93-100
    • /
    • 2011
  • Sonic branding is defined as creation and management of brand value by using sounds. Among various methods of sonic branding, sonic logo, i.e., brand’s acoustic identification element, is the most widely used form and usually combined with visual logo. Although sonic branding has become an increasingly important tool for marketers, little academic research has been done on this topic. The current study investigates neural responses to sonic branding using functional Magnetic Resonance Imaging (fMRI). Brain activity of 15 right-handed participants was monitored with 3T MRI machine, while they viewed sequentially presented pictures of brand logos (20 visual logos usually accompanied by sonic logos and 20 visual logos unaccompanied by sonic logos) without sound. Results showed that brain areas known to be associated with auditory imagery (including superior temporal gyrus, STG), showed greater activation for the visual logos usually accompanied by sonic logos compared to visual logos unaccompanied by sonic logos, although actual sound was not presented during scanning. The degree of familiarity participants have with the brand and its advertisements was correlated positively with signal strength in these areas.

  • PDF

The Effect of Acupuncture with Magnetic Ring on Pain Threshold Using Algometer (자기장을 통한 침자극이 압통 역치에 미치는 영향)

  • Lee, Jong-Hoon;Min, Byung-Il;Hwang, Byung-Gil;Jang, Jin;Hong, Mu-Chang
    • Journal of Acupuncture Research
    • /
    • v.19 no.3
    • /
    • pp.77-87
    • /
    • 2002
  • Like acupuncture, magnetic therapy has been known to yield effectiveness when it is applied to relieve from fatigue, musculoskelectal diseases, sore sites, rheumatic arthritis and chronic pain syndromes. However, combined application of acupuncture and magnet has not yet been studied. This study is designed to investigate effectiveness of acupuncture therapy when in the magnetic field for the pain relief. Magnetic field was made by magnetic ring ($7{\psi}{\times}2.3{\psi}{\times}1.5mm$). Twenty-one male swimmers with latent muscular pain at the GB21 area in the university course of physical education in Daegu were chosen and divided into three groups; 1) acupuncture treatment group (n=7), 2) acupuncture treatment with iron ring group (n=7), 3) acupuncture treatment with magnetic ring group (n=7). Manual Acupuncture was given to the GB21 point for 20 minutes. The degree of pressure pain threshold (PPT, $kg/cm^2$) in GB21 was measured with algometer. Before acupuncture treatment, the PPT values were $6.08{\pm}1.69$, $6.39{\pm}1.72$ and $5.59{\pm}1.11$ in acupuncture treatment group, acupuncture treatment with iron ring group, acupuncture treatment with magnetic ring group, respectively. After acupuncture treatment, the PPT values were $6.48{\pm}2.33$, $6.31{\pm}1.31$ and $6.59{\pm}1.80$, respectively. Pressure threshold was significantly increased in the acupuncture treatment with magnetic ring group compared to the other groups. Based on these results, acupuncture treatment with magnetic ring produced better effects on pain threshold, and these effects can be considered to be associated with the currents or voltages induced by the acupuncture needle and magnetic ring at present.

  • PDF

A Report on 6 cases of Abdominal Obesity using Electroacupuncture Combined with Magnetic Acupuncture (전기와 자기장 복합 침 자극을 활용한 복부비만 치료 6례에 대한 증례 보고)

  • Yun, Gee Won;Lee, Hyun;Kim, Yun Joo;Kang, Jae Hui
    • Journal of Acupuncture Research
    • /
    • v.32 no.4
    • /
    • pp.213-226
    • /
    • 2015
  • Objectives : This study was aimed to show the effect of electroacupuncture combined with magnetic acupuncture on abdominal obesity without patient dieting, exercise or use of herbal medication. Methods : Women over 85 cm in waist circumference were treated with electroacupuncture combined with magnetic acupuncture. Acupuncture points were located at the abdomen ($CV_{12}$, $CV_6$, $ST_{25}$, $ST_{21}$, $SP_{15}$, $SP_{14}$), extremities ($LI_4$, $LI_{11}$, $ST_{36}$, $ST_{44}$) and were stimulated 30 minutes with 2.1~3 Gaus, 500 Hz, tolerable strength. The Interference wave forms were by Whata 153 (Medi Lab, Korea). Two or three treatment sessions per week (five or ten sessions in total) were done. Before treatment, and after the last treatment, we measured waist circumference, hip circumference, waist hip ratio, thickness of abdominal subcutaneous fat, body weight, body mass index, body fat ratio, visceral fat area, free fat mass, body fat mass and skeletal muscle mass. We also measured the subcutaneous temperature of the abdomen($CV_{12}$, $ST_{25}(Rt)$, $ST_{25}(Lt)$, $CV_6$) by using digital infrared thermal imaging(DITI). Results : In this study, significant reductions were shown in waist circumference, hip circumference, thickness of abdominal subcutaneous fat, body weight, body mass index, body fat ratio and body fat mass. There were no significant differences in waist hip ratio, free fat mass or skeletal muscle mass. There were also significant increases of the subcutaneous temperature on $CV_{12}$, $ST_{25}(Rt)$, $ST_{25}(Lt)$. Conclusions : From the above results, electroacupuncture combined with magnetic acupuncture might be an effective treatment for abdominal obesity.

A Neuromuscular Biomechanic Study of the Modulation of Corticospinal Excitability by Observation and/or Imagery of Action in Older Adults (장 노년층에서의 운동 연상 및 관찰에 따른 피질척수로 변화에 대한 근신경 역학적 연구)

  • Choi, Eun-Hi
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.4
    • /
    • pp.681-688
    • /
    • 2009
  • To better delineate the changes in corticospinal excitability when older adults are asked to observe and/or imagine actions, 22 right-handed older adults without neurological abnormalities were included in this study. The amplitude and latency of motor evoked potentials (MEPs) by transcranial magnetic stimulation were recorded in the abductor pollicis brevis of the dominant hand during passive observation/imagery/active observation of slow/fast action of abduction of right thumb and also at resting state. Thus, active observation showed better changes than passive, but slow and fast action revealed no difference at all.

Treatment Methods for Functional Recovery after Total Knee Arthroplasty (슬관절 전치환술 후 기능 회복을 위한 치료법)

  • Kim, Young-mo;Joo, Yong-bum;Park, Il-young
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.2
    • /
    • pp.117-126
    • /
    • 2020
  • Total knee arthroplasty is performed widely in degenerative arthritis of the knee joint, and the frequency of use is increasing. Efforts should be made to achieve functional recovery, such as returning to daily life, and the recovery of strength and range of motion after surgery. The procedure should be approached from a range of perspectives, such as patient factors, surgical technique and rehabilitation. The patient's age, degree of obesity, sex, and strength of the quadriceps muscle can affect the functional recovery after surgery. In addition, the patient's mental state, such as expectation value and satisfaction, can also have an effect. For functional recovery, patient education, pain control, and strengthening of the quadriceps muscle can be performed prior to surgery. Postoperative physiotherapy, such as icing and compression, transcutaneous electrical nerve stimulation therapy, neuromuscular electrical stimulation therapy, low frequency low intensity magnetic field therapy, strengthening of quadriceps muscle, and range of motion exercise can also be applied. In recent years, hydrotherapy, which restores the strength and balance of the leg, is being performed increasingly. These treatments are not only performed shortly after surgery, but are also performed continuously. In addition, the surgeon should apply it appropriately considering the patient's condition, compliance, and social and psychological conditions.

The Comparison between Single Shot Turbo Spin Echo and B-FFE (Balanced Turbo Field-echo) in the Differentiation of Focal Liver Lesions (국소 간병변 감별에서 단발고속스핀에코 기법과 균형항정상 태세차를 이용한 고속영역 기법간의 비교)

  • Kim, Young-Chul;Kim, Myeong-Jin;Cha, Seung-Whan;Chung, Yong-Eun;Han, Kwang-Hyup;Choi, Jin-Sub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.1
    • /
    • pp.39-48
    • /
    • 2007
  • Purpose : To determine the diagnostic accuracy of four different sequences : moderately T2 weighted, two heavily T2-weighted single shot turbo spin-echo sequence and breath-hold axial-2D balanced turbo field-echo sequence(bFFE) for characterization of focal lesions. Materials and Methods : During the 3-month period between June and August 2005, seventy-six patients were proved to have ninety-three focal hepatic lesions on MR imaging. The patients consisted of 49 men and 27 women (age range, 15-75 years; mean age, 56.23 years). All MR images were acquired on a 1.5-T MR using the following sequences: 1. A breath-hold axial T2-weighted single shot turbo spin-echo sequence, 2. a breath-hold axial-2D balanced turbo field-echo sequence. Two radiologists performed quantitative analysis. Another radiologist measured the lesion-to-liver contrast-to-noise ratio at the region-of-interest in the four sequences. Results : There was no significant difference in inter-observer variability between the four sequences. The accuracy for both cyst and malignancy of moderate T2 weighted MRI (echo time: 80 msec) was also highest. There was significant difference for lesion characterization between moderate T2 weighted MRI and balanced steady state procession (p-value: 0.004) in the second reader. For longer echo time, the CNR of cystic lesions were markedly increased in comparison to lesions of other component. Conclusion : The accuracy and inter-observer variability of single shot turbo spin echo T2 weighted sequence was higher than bFFE. Although there was no statically significant difference, moderate T2 weighted MRI (echo time: 80 msec) was more accurate than heavily T2 weighted sequence (echo time: 300 msec). If the results for lesion characterization is equivocal in TE 80, the addition of heavily T2 weighted MRI (echo time: 180 msec) can be helpful.

  • PDF