• 제목/요약/키워드: 자기계측

Search Result 151, Processing Time 0.036 seconds

Using Two-Dimensional Chemiluminescence Images to Study Inhomogeneity in Mixture Gas in the Combustion Chamber for HCCI Combustion (이차원발광화상계측에 의한 예혼합압축자기착화연소의 연소실내 혼합기의 불균질성에 관한 연구)

  • Lim, Ock-Taeck;Iida, Norimasa
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.12
    • /
    • pp.1043-1050
    • /
    • 2010
  • Fuel stratification and thermal stratification occur in the HCCI combustion chamber on a microscopic scale. They affect the ignition and combustion processes. In this study, the effect of the inhomogeneity in the mixture gas on the HCCI combustion process was investigated. Two-dimensional chemiluminescence images were captured using a framing camera to evaluate the flame structure. DME was used as the test fuel. First, the effect of inhomogeneity in the fuel distribution in the premixture was investigated for the four-stroke optically accessible engine. Then, by comparing the combustion of the homogeneous mixture in the rapid compression machine, which does not contain any residual gas, with the combustion in the four-stroke engine, the effect of inhomogeneity in temperature due to the residual gas was analyzed. The results showed that a time lag appears spatially in combustion under inhomogeneous conditions in the four-stroke engine. The spatial variation in the combustion without the residual gas in the rapid compression machine is less than that in the combustion in the four-stroke engine.

Displacement Measurement of Structure using Multi-View Camera & Photogrammetry (사진측량법과 다시점 카메라를 이용한 구조물의 변위계측)

  • Yeo, Jeong-Hyeon;Yoon, In-Mo;Jeong, Young-Kee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.1141-1144
    • /
    • 2005
  • In this paper, we propose an automatic displacement system for testing stability of structure. Photogrammetry is a method which can measure accurate 3D data from 2D images taken from different locations and which is suitable for analyzing and measuring the displacement of structure. This paper consists of camera calibration, feature extraction using coded target & retro-reflective circle, 3D reconstruction and analyzing accuracy. Multi-view camera which is used for measuring displacement of structure is placed with different location respectively. Camera calibration calculates trifocal tensor from corresponding points in images, from which Euclidean camera is calculated. Especially, in a step of feature extraction, we utilize sub-pixel method and pattern recognition in order to measure the accurate 3D locations. Scale bar is used as reference to measure. the accurate value of world coordinate..

  • PDF

Usefulness of Dual-Echo in Steady State (DESS) Image in Chondromalacia of Knee Joint: Comparison of DESS and Turbo Spin-Echo MR Images (슬관절 연골 연화증의 진단에서의 Dual Echo in Steady State (DESS) 영상의 유용성 : 급속 스핀에코 자기공명 영상과 비교)

  • 윤삼현;하두회
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.1
    • /
    • pp.66-72
    • /
    • 1999
  • Purpose : To evaluate the usefulness of Dual Echo in Steady State(DESS) image in the diagnosis of chondromalacia of the knee compared with turbo spin-echo MR images Materials and Methods : We included 26 patients with chondromalacia of the knee. MR imaging was obtained with a 1.5T imager. Sagittal and coronal double echo T2 weighted images(TR/TE 3000-4200/16-96msec, FOV $140-160{\times}140-160mm$, matrix size $180{\times}256$, slice thickness 4.0mm, interslice gap 0.5mm), and sagittal DESS image(TR/TE 25.4/9.0msec, flip angle $35-45^{\circ}$, FOV $150-160{\times}150-160mm,{\;}matrix{\;}size{\;}192{\times}256$, effective slice thickness 1.5mm) were obtained. Cartilage lesions were staged according to a modified scheme proposed by Outerbirdge: grade 0, normal; grade 1, softening or/and swelling; grade 2, mild surface fibrillation or/and less than 50% of cartilage thickness; grade 3, severe surface fibrillation or/and loss of more than 50% of cartilage thickness but without exposure of subchondral bone; and grade 4, complete loss of cartilage with subchondral bone exposure. Gradings were determined by two readers with consensus, and patellofemoral, medial and lateral tibiofemoral compartments were evaluated. Results : Arthroscopic findings revealed grade 1 in seven cases, grade 2 in 21 cases, grade 3 in six cases, and grade 4 in 18 cases. Sensitivity of turbo spin-echo MR image was as follows; 0%, 14%, 0%, 61% in each grade, and sensitivity of DESS image was as follows; 0%, 33%, 50%, 67%, in each grade(p=0.001). In the detection of chondromalacic lesions regardless of gradings, sensitivity, specificity and accuracy of conventional MR image were 59.6% 88.6% 78.8%, and of DESS image, 73.1% 88.4%, 82.2%(p=0.007). Conclusion : For chondromalacia of knee joints, DESS images showed higher sensitivity than turbo spin-echo MR images. Therefore, DESS images will be helpful for diagnosis of chondromalacia of knee joints.

  • PDF

An Experimental Method of Model Installed Dynamic Positioning System for Drillship (드릴쉽에 대한 DPS 모형시험 기법개발)

  • Dong-Yeon Lee;Mun-Keun Ha
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.38 no.2
    • /
    • pp.33-43
    • /
    • 2001
  • The design and construction of special purpose vessels such as drillship and shuttle tankers have been increased. These vessels install the DPS(dynamic positioning systems) to maintain the position and heading for long-time operation. This paper deals with the experimental method for model-based DP system and the control theory and filter algorithms. In this experiment, the length of model ship is 4 meters and it has three thrusters to maintain the position. The ability of tracking along the given course and keeping of heading in waves are confirmed. For the calculation of thruster input the PID control theory are adopted and the effects of PID gain were investigated. To estimate the low frequency motions Kalman filter and digital filter were used and their effects were investigated.

  • PDF

Estimation of radial spectrum for rainfall (호우의 환상스펙트럼 추정)

  • Lee, Jae-Hyeong;Lee, Dong-Ju;Park, Yeong-Gi
    • Water for future
    • /
    • v.22 no.2
    • /
    • pp.201-211
    • /
    • 1989
  • Using the storm data which was augmented by the stochastic correlation with it's neighbors, the multiquadric equation of random surface of total storm depth is constructed. And to separate the local components from it's regionals and find the regional characteristics, a double Fourier analysis was applied to the total depths of storm data. The local components, storm residuals of each storm was assumed to be homogeneous random field and investigated with it's autocorrelation function. For the practical application, isotropic was assumed and that was identified with emprical data. Coefficients of normalized autocorrelation for all storms showed similar apperance. Using this emprical result, an example of the radial spectral distribution function which represints the spatial characteristics of rainfall over Han River Basin during 1975-1983 is presented.

  • PDF

Ankle Morphometry in Adults using MRI (성인에서 자기 공명 영상을 이용한 족관절 형태 계측)

  • Yoo, Moon-Jib;Kim, You-Jin
    • Journal of Korean Foot and Ankle Society
    • /
    • v.11 no.1
    • /
    • pp.18-22
    • /
    • 2007
  • Purpose: To provide basic data on anatomy of the ankle joint in adults using magnetic resonance imaging as well as to compare measurements with available data of corresponding dimension in the different sizes of the total ankle replacements design ($HINTEGRA^{(R)}$). Materials and Methods: Magnetic resonance (MR) sagittal and coronal images from one hundred-forty nine were studied. Post traumatic, arthritic, or grossly deformed ankles at any reason were excluded. Lengths, widths of the main parts of this articulation and also the radius of curvature of talar dome were measured in the MR images. Statistical analysis was performed on these measurements. Results: On MR coronal image data, average tibial width was $30.0{\pm}4.1\;mm$ and talar width was $27.0{\pm}3.4\;mm$. On sagittal image date, average anteroposterior length of the distal tibia was $39.0{\pm}4.2\;mm$, average anteroposterior length of the talus was $31.3{\pm}2.8\;mm$, and average sagittal radius of curvature of talar dome was $20.1{\pm}2.9\;mm$. All measurements in male were significantly larger than in female (p<0.01), but a significant difference according to age was not found. Conclusion: Ankle morphometric data define a basis of size, particularly useful in the design of ankle prostheses.

  • PDF

Remote Measurement for Automobile′s ECU Diagnostic Signals based on the PDA (PDA 기반의 차량 진단신호의 원격 계측)

  • 윤여흥;서지원;이현호;권대규;이영춘
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.279-282
    • /
    • 2002
  • In this paper, we present a new method for monitoring of ECU's self diagnostic signals of vehicle without wire. In order to measure the ECU's self diagnostic signals, the interfaced circuit is designed to communicate ECU and a designed display terminal according to the ISO, SAE regulation of communication protocol standard. A 80C196KC processor is used for communicating ECU's self diagnostic signals and the results are sent to PDA monitoring system. Software on PDA is developed to monitor the ECU's self diagnostic signals using the Embedded Visual C++ compiler in which RS232 port is programmed by half duplex method. The algorithms for measuring the ECU's self diagnostic signals are verified to monitor ECU's state. At the same time, the information to fix the vehicle's problem can be shown on the developed PDA software. The possibility for remote measurement of ECU self diagnostic signal using PDA is also verified through the developed systems and algorithms.

  • PDF

Remote Measurement for Automobile′s ECU Sensor Signals Using RF modules (RF모듈을 이용한 자동차 ECU 센서신호의 원격계측)

  • 이성철;서지원;권대규;방두열
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1067-1070
    • /
    • 2003
  • In this paper, we present a remote measurement system for the wireless monitoring of ECU Sensor Signals of vehicle. In order to measure the ECU sensor signals, the interface circuit is designed to communicate ECU and designed terminal wirelessly according to the ISO, SAE regulation of communication protocol standard. A micro-controller 80C196KC is used for communicating ECU sensor signals. ECU sensor signals are transmitted to the RF-wireless terminal that was developed using the micro controller 80386EX. LCD, and RF-module. 80386EX software is programmed to monitor the ECU sensor signals using the Borland C++ compiler in which the half duplex method was used for the RS232 communication. The algorithms for measuring the ECU sensor signals are verified to monitor ECU state. At the same time, the information to fix the vehicle's problem can be shown on the developed monitoring software. The possibility for remote measurement of ECU sensor signals using 80386EX is also verified through the developed systems and algorithms.

  • PDF

A Rapid Method for the Measurement of the Absolute Activity of Carbon-14 in Pea Plant Tissue

  • Kendall, F.H.;Park, Chang-Kyu;Mer, C.L.
    • Applied Biological Chemistry
    • /
    • v.18 no.2
    • /
    • pp.56-60
    • /
    • 1975
  • A rapid method for the measurement of the absolute activity of carbon-14 in cotyledons and root of etiolated pea seedlings has been developed. Fresh tissue was frozen in liquid air, ground and suspended in gel phosphor and subjected to measurement for its radioactivity by liquid scintillation counter. Apparent activity of the suspended tissue sample calculated by counting efficiency value obtained by internal standardisation, was found to be related to absolute activity of the tissue, determined by flask combustion technique, by a constant factor. Once this factor is determined experimentally, analysis of C-14 lebelled tissue involves only fairly simple suspension counting by liquid scintillation counter. Present method appears to be applicable to other tissues tagged with C-14.

  • PDF

The Overall Measurement System Development for On-line Test of Super-speed Maglev Train (초고속 자기부상철도 시운전시험을 위한 종합계측시스템 개발)

  • Han, Young-Jae;Lee, Jin-Ho;Jo, Jung-Min;Kim, Lee-Hyung;Lee, Chang-Young;Ha, Chang-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.902-910
    • /
    • 2016
  • This paper presents the overall measurement system for on-line test of super-speed maglev train. The super-speed maglev train is composed of vehicle, propulsion, power, and so on. In order to evaluate and diagnose for sub-system, we made overall measurement system. Just like the other measurement system, it is designed to distributed type. The hardware is consist of SCXI, PXI, Terminal, UPS, and so forth. It is installed on a train, control room, power room and track to collect lots of signals. The software controls hardware system, monitors main data such as inverter current, converter voltage. Using the measurement system, we evaluated a lot of performances for vehicle, track, and so forth. Through the developed system have improved reliability and safety for super-speed maglev train.