• Title/Summary/Keyword: 자기감지

Search Result 164, Processing Time 0.024 seconds

Development of the Non-contacted Gear Detection Sensor for a Manual Transmission (수동변속기용 비접촉식 변속단 감지센서 개발)

  • Han, Chang-Kyu
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.5
    • /
    • pp.1-7
    • /
    • 2013
  • The present paper relates to a development of the Gear Detection Sensor for automotive manual transmission. To detect air gap from control finger to detecting zone of sensor based on non-contacted method, permanent magnet and linear type Hall IC are mounted in this sensor. Control finger is machined to 3 step heights to detect 3 gear stages such as In-Gear, Normal and Rear. After conducting actual experimentation based on exclusive Jig and FEM, it is described to consider possibility for automotive application of Gear Detection Sensor.

세라믹 센서의 현상과 장래동향

  • 박춘배;송민종
    • Electrical & Electronic Materials
    • /
    • v.7 no.5
    • /
    • pp.438-446
    • /
    • 1994
  • 인류는 지금 2차석기시대를 맞이하고 있으며 이 시대는 인공으로 만들어지는 돌인 세라믹이 단순히 용기나 도구로 사용되는 것 이외에 정보화사회에 있어서 기술의 관건이 될 지능소자로서 사용되고 있다. 세라믹은 내열성, 내식성, 내마모성이라는 특성으로 인해 많이 이용되어 왔지만 이러한 특성 이외에도 전자적 기능, 광학기능, 화학기능 등 "두뇌"도 우수한 재료라 할 수 있다. 더구나 세라믹은 인간을 대신하여 감지하는 것이 가능한 각종 센서로서도 폭넓게 이용되고 있다. 인간에 있어서 눈, 코, 귀, 혀, 피부 등 오감이 센서이며, 눈은 물체를 식별하는 것으로 빛을 검출하고 귀는 소리를 듣는 것으로 압력과 음파를 검출하고, 코는 냄새로 가스나 온도를 검출하고, 혀는 맛으로 미각을 검출하고, 피부는 촉각에 의한 압력, 온도, 습도를 검출하며, 인간의 오감에 대응되지 않는 것으로 세라믹 센서는 자기장을 감지할 수 있다. 이와같이 센서는 용도에 따라 수많은 센서가 개발되어 그 종류가 대단히 많기 때문에 모든 센서에 대해서 기술한다는 것은 어렵다. 그러므로 여기서는 센서중에서 기본적인 가스센서와 습도센서에 대해 소개하기로 한다. 소개하기로 한다.

  • PDF

Development of Low-Power CO Gas Sensor (저전력 CO 가스센서 개발)

  • Cha, Sung-Ik;Shin, Paik-Kyun;Lee, Boong-Joo;Kim, Jong-Won;Gang, Moon-Sik;Min, Nam-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1410-1412
    • /
    • 2003
  • PTC 자기발열기판을 사용해서 저전력 방폭형 CO센서를 제작하고 그 특성을 고찰하였다. CO가스센서의 감지특성을 향상시키기 위하여 Pt가 island 형상을 갖는 다층 Pt/$SnO_2$ 박막구조를 도입하였으며, 이와 같은 구조는 Pt/$SnO_2$ 위에 다시 $SnO_2$ 및 Pt cluster 층들을 연속적으로 증착함으로서 제작되었다. 200ppm의 CO가스농도에서 측정된 다층 $Pt/SnO_2$박막 센서의 감도는 1.72($R_{air}/R_{CO}$)로, 단충 Pt/$SnO_2$ 박막 센서의 최대감도(1.23)보다 훨씬 더 높았다 이것은 Pt와 $SnO_2$사이의 계면적 증대에 기인하는 것으로 생각된다. 제작된 Pt/$SnO_2$ 가스센서의 평균 소비전력은 38.5mW이며, 측정농도범위($30{\sim}1,000ppm$)에서 매우 양호한 감지특성을 나타내었다.

  • PDF

Electrochemical characterization of 3-mercaptopropionic acid self-assembled monolayer for urea sensor (요소센서를 위한 3-mercaptopropionic acid 자기조립 단일층의 전기화학적 특성 분석)

  • Yun, Dong-Hwa;Song, Min-Jung;Kim, Jong-Hoon;Kang, Moon-Sik;Min, Nam-Ki;Hong, Suk-In
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1579-1581
    • /
    • 2004
  • 바이오센서는 효소(enzyme), 생분자(biomolecule), 항체(antibody), 세포(cell) 등의 biological agent를 인지 물질(recognition material)로 하여 측정하고자하는 분석 대상(analyte)과 높은 선택성으로 반응을 일으키게 하여 그 결과를 기존의 물리, 화학센서로 감지 해내는 방식이므로 기존의 의료용 화학센서를 대체하는 추세이다. 바이오센서가 기존의 센서와 구별되는 점은 생물질의 선택적인 반응 및 결합을 이용하는 것이므로 바이오센서의 실용화에 있어서 가장 중요한 것은 생체 반응 물질의 고정화 기술과 고정화막의 선택이라 할 수 있다. 일정전압법을 이용한 요소센서는 많이 연구되어 오고 있으나 낮은 농도에서의 감도저하에 따른 단점으로 상용화에 이르지 못하고 있다. 본 논문은 요소센서의 이용하기 위한 고정화막으로 3-mercaptopropionic acid 자기조립 단인층의 전기화학적 특성을 고창하였다. 자기조립 단일층은 직접적인 전자전달로 인하여 낮은 요소 농도에서 뛰어난 강도와 빠른 반응 시간을 보였으며, 특히 다공질 실라콘을 기질로 사용한 경우 평면 전극 보다 약 3배의 감도 증가 효과를 가져왔다. 자기조립 단일층의 표면 분석은 X-ray photoelectron spectroscopy(XPS)를 이용하였다.

  • PDF

Fabrication and Chracteristics of Magnetic Sensor using Ceramic Superconductor (산화물 초전도체를 이용한 자기센서의 제작 및 특성)

  • Lee, Sang-Heon
    • Journal of IKEEE
    • /
    • v.3 no.2 s.5
    • /
    • pp.243-249
    • /
    • 1999
  • A magnetic field sensor is fabricated with superconducting ceramics of Y-Ba-Cu-O system. The prepared material shows the superconductivity at about 95K. The sensor at liquid nitrogen temperature shows the increase in electrical resistance by applying magnetic field. Actually, the voltage drop across the sensor is changed from zero to a value. more than $100{\mu}V$ by the applied magnetic field. The change in electrical resistance depends on magnetic field. The sensitivity of this sensor is 2.9 ohm/T. The sensing limit is about $1.5{\times}10^{-5}T(=1.5{\times}10^{-1}G)$. The increase in electrical resistance by the magnetic field is ascribed to a modification of the Josephson junctions due to the penetrating magnetic flux into the superconducting material.

  • PDF

Interfacial Evaluation and Hydrophobicity of Multifunctional Hybrid Nanocomposites for Self-sensing and Actuation (자체 감지능 및 작동기용 다기능 하이브리드 나노복합재료의 계면 특성 및 소수성 표면 연구)

  • Wang, Zuo-Jia;GnidaKouong, Joel;Jang, Jung-Hoon;Kim, Myung-Soo;Park, Joung-Man
    • Composites Research
    • /
    • v.23 no.2
    • /
    • pp.24-30
    • /
    • 2010
  • Interfacial evaluation and hydrophobicity of Ni-nanopowder/epoxy composites were investigated for self-sensing and actuation. Contact resistance and resistivity were measured using gradient micro-specimens. The actuation of the composites in the electromagnetic field was studied with three wave functions, i.e., sine, triangle and square functions. Due tothe presence of hydrophobic domains on the heterogeneous surface, the static contact angle of Ni-nanopowder/epoxy nanocomposite wasabout $100^{\circ}$, which was rather lower than that for super-hydrophobicity. The dynamic contact angle showed the similar trend of static contact angle. Ni-nanopowder/epoxy composite was responded wellfor both self-sensing and actuation in electromagnetic field due to the intrinsic metal property of Ni-nanopowder. Displacement of the actuator of Ni-nanopowder/epoxy composite was evaluated to obtain the maximum and the optimum performance using laser displacement sensor as functions of the wave type, frequency, and voltage. Actuation of Ni-nanopowder/epoxy composites also increased as functions of applied frequency and voltage. Actuated strain increased more rapidly at sine wave with increasing voltage compared to those of triangle or rectangular waves.

Head Motion Detection and Alarm System during MRI scanning (MRI 영상획득 중의 피험자 움직임 감지 및 알림 시스템)

  • Pae, Chong-Won;Park, Hae-Jeong;Kim, Dae-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.1
    • /
    • pp.55-66
    • /
    • 2012
  • Purpose : During brain MRI scanning, subject's head motion can adversely affect MRI images. To minimize MR image distortion by head movement, we developed an optical tracking system to detect the 3-D movement of subjects. Materials and Methods: The system consisted of 2 CCD cameras, two infrared illuminators, reflective sphere-type markers, and frame grabber with desktop PC. Using calibration which is the procedure to calculate intrinsic/extrinsic parameters of each camera and triangulation, the system was desiged to detect 3-D coordinates of subject's head movement. We evaluated the accuracy of 3-D position of reflective markers on both test board and the real MRI scans. Results: The stereo system computed the 3-D position of markers accurately for the test board and for the subject with glasses with attached optical reflective marker, required to make regular head motion during MRI scanning. This head motion tracking didn't affect the resulting MR images even in the environment varying magnetic gradient and several RF pulses. Conclusion: This system has an advantage to detect subject's head motion in real-time. Using the developed system, MRI operator is able to determine whether he/she should stop or intervene in MRI acquisition to prevent more image distortions.

New Implementation Method of the Pulsed Nuclear Magnetic Resonance Apparatus (펄스방식의 핵자기 공명장치에 관한 새로운 구현방법)

  • 김청월
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.10
    • /
    • pp.1-11
    • /
    • 1998
  • This paper presents a new implementation method of the pulsed NMR(nuclear magnetic resonance) apparatus, which contains a single coil in a magnet console, to detect a NMR signal. Applying an RF magnetic field of 5MHz to the magnet console which is designed to have Larmor frequency of 5MHz for hydrogen atom, the hydrogen NMR signal was obtained from the glycerin which was put in the magnet console as a sample. The DC magnetic field in the magnet console was implemented with a permanent magnet of 1168 gauss and the RF magnetic field was generated appling an RF signal with the frequency of 5MHz and the current magnitude of 8A to a coil of 5.73${\mu}$H. The magnitude of the NMR signal was maximum when the RF magnetic field was generated for 2.8 ${\mu}$sec, and the period of generating the RF magnetic field was designed to 100msec for detecting the NMR signal repeatedly. The NMR signal, radiated from the sample in the magnetic console, was appeared as an amplitude-modulated signal with a frequency equal to the Larmor frequency. The signal, induced in the coil, was amplified in the tx/rx separation circuit, preamplifier and intermediate amplifier by a factor of 20.7dB, 36dB and 40dB, respectively, and the signal was detected by a synchronous detection circuits, then the NMR signal was obtained.

  • PDF

MGlove: A Sensor-based Input Device for Sensor Network Environment (MGlove: 센서 네트워크 환경에서의 사용자 센싱에 기반 한 입력 장치)

  • 김효승;박광규;박현구;차호정
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.10b
    • /
    • pp.526-528
    • /
    • 2004
  • 본 논문은 센서 네트워크 환경에서 사용자 센싱을 통한 입력장치인 MGlove (Multiple-sensing Clove)의 구현에 대해 기술한다. 본 입력장치는 버튼 없이 2축 가속 센서, 2축 자기 센서, 포토 다이오드의 세 가지 종류의 센서를 사용하여 사용자의 손동작을 통해 입력을 감지하고 RF 모듈을 이용하여 무선으로 통신 가능하다. 구현한 MGlove는 유비 쿼터스 센서 네트워크 환경을 위한 입력 장치로 context-aware input device로의 발전 가능성이 있으며, 센서 추적 기법을 통해 사용자의 자세, 위치, 방향에 관계없이 입력 가능하고 RF모듈을 통해 먼 거리에서도 조작이 가능한 특징을 가진다.

  • PDF

A Research on the Vehicle Detecting Using Earth Magnetic Field Sensor (지자기 센서를 이용한 차량감지 관한 연구)

  • Kang, Moon-Ho;Jeong, Dae-Yeon
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1239-1241
    • /
    • 2001
  • This research addresses a new vehicle detecting scheme which uses MR(Megneto Resistive) sensor. A vehicle detector which includes two MR sensors for detecting car presence and speed, sensor voltage amplifiers, signal processor, microprocessor, RF data transceiver and a simple car moving simulator is constructed. From experimental results with the vehicle detector the proposed vehicle detecting scheme was verified.

  • PDF