• Title/Summary/Keyword: 자궁경부암 근접치료

Search Result 45, Processing Time 0.022 seconds

Dose Distribution of Rectum in the treatment of Uterine Cervical Cancer using Remote Afterloading System (RALS시행시 선원의 거리 이동및 직장선량에 관한 계산치와 측정치의 비교연구)

  • 김성규;신세원;김명세
    • Progress in Medical Physics
    • /
    • v.5 no.1
    • /
    • pp.67-74
    • /
    • 1994
  • Dose distribution of point source represents an inverse square law as the distance, Difference of measurement value and calculation value according to moving distance of radiation source show very large error in dose calculation of Brachytherapy. Therefore, in RALS of high dose rate, dose calculation have an important effect in treatment of uterine cervix cancer and recurrent rate. In this paper, authors measured moving distance of radiation source carrying out RALS. And we measured Rectum dose compared with calculationdose.

  • PDF

Prediction of Late Rectal Complication Following High-dose-rate Intracavitary Brachytherapy in Cancer of the Uterine Cervix (자궁경부암 환자의 고선량률 강내치료 시행 시 직장합병증의 예측)

  • Lee, Jeung-Eun;Huh, Seung-Jae;Park, Won;Lim, Do-Hoon;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.21 no.4
    • /
    • pp.276-282
    • /
    • 2003
  • Purpose: Although high-dose-rate intracavitary radiotherapy (HDR ICR) has been used in the treatment of cervical cancer, the potential for increased risk of late complication, most commonly in the rectum, is a major concern. We have previously reported on 136 patients treated with HDR brachytherapy between 1995 and 1999. The purpose of this study is to upgrade the previous data and confirm the correlation between late rectal complication and rectal dose in cervix cancer patients treated with HDR ICR. Materials and Methods: A retrospective analysis was peformed for 222 patients with cevix cancer who were treated for curative intent with external beam radiotherapy (EBRT) and HDR ICR from July 1995 to December 2001. The median dose of EBRT was 50.4 (30.6$\~$56.4) Gy with a daily fraction size 1.8 Gy. A total of six fractions of HDR ICR were given twice weekly with fraction size of 4 (3$\~$5.5) Gy to A point by Iridium-192 source. The rectal dose was calculated at the rectal reference point using the barium contrast criteria. in vivo measurement of the rectal dose was peformed with thermoluminescent dosimeter (TLD) during HDR ICR. The median follow-up period was 39 months, ranging from 6 to 90 months. Results: Twenty-one patients (9.5$\%$) experienced late rectal bleeding, from 3 to 44 months (median, 13 months) after the completion of RT. The calculated rectal doses were not different between the patients with rectal bleeding and those without, but the measured rectal doses were higher in the complicated patients. The differences of the measured ICR rectal fractional dose, ICR total rectal dose, and total rectal biologically equivalent dose (BED) were statistically significant. When the measured ICR total rectal dose was beyond 16 Gy, when the ratio of the measured rectal dose to A point dose was beyond 70$\%$, or when the measured rectal BED was over 110 Gy$_{3}$, a high possibility of late rectal complication was found. Conclusion: Late rectal complication was closely correlated with measured rectal dose by in vivo dosimetry using TLD during HDR ICR. If data from in vivo dosimetry shows any possibility of rectal bleeding, efforts should be made to reduce the rectal dose.

Low Dose Cisplatin as a Radiation Sensitizer in Management of Locally Advanced Scluamous Cell Carcinoma of the Uterine Cervix : Evaluation of Acute Toxicity and Early Response (국소 진행된 자궁경부암의 방사선치료와 저용량 cisplatin 항암요법 동시치료시 급성독성 밀 초기반응 평가)

  • Kim Hunjung;Cho Young Kap;Kim Chulsu;Kim Woo Chul;Lee Sukho;Loh J K
    • Radiation Oncology Journal
    • /
    • v.17 no.2
    • /
    • pp.113-119
    • /
    • 1999
  • Purpose : To evaluate possible acute toxicity and early response of concurrent radiation therapy and low dose daily cisplatin as a radiosensitizer in patients with locally advanced uterine cervical carcinomas. Materials and Method : From December 1996 to January 1999, 38 previously untreated Patients with locally advanced squamous cell carcinoma of the uterine cervix (from stage IIB to stage IIIB) were treated at Inha University Hospital. All patients underwent standard pretreatment staging Procedures after the initial evaluation by gynecologists and radiation oncologists. Sixteen Patients with huge cervical mass (>4 cm) were submitted to the group treated with concurrent radiation therapy and low dose daily cisplatin while the remainder was treated with radiation therapy alone. Radiation therapy consisted of 4500 cGy external beam irradiation to whole pelvis (midline block after 3000 cGy), 900$\~$1000 cGy boost to involved parametrium, and high dose-rate intracavitary brachytherapy (a total dose of 3000$\~$3500 cGy/500 cGy per fraction to point A, twice per week). In the group treated with low dose cisplatin concurrently, 10 mg of daily intravenous cisplatin was given from the 1st day of radiation therapy to the 20th day of radiation therapy. Acute toxicity was measured according to expanded common toxicity criteria of the NCI (C) Clinical Trials. Early response data were analyzed at minimum 4 weeks' follow-up after completion of the treatment protocol. Results: Hematolgic toxici쇼 was more prominent in patients treated with radiation therapy and cisplatin. Six of 16 patients (37.5$\~$) treated with radiation therapy and cisplatin and one of 22 patients (4.5$\~$) treated with radiation therapy alone experienced grade 3 leukopenia. In Fisher's exact test, there was statistically significant difference between two groups regarding leukopenia (P=0.030). There was no apparent difference in the frequency of gastrointestinal and genitourinary toxicity between two groups (P=0.066). Three of 16 patients (18.7$\~$) treated with radiation therapy and cisplatin and two of 22 patients (9.1$\~$) treated with radiation therapy alone experienced more than 5 kg weight loss during the treatment. There was no statistically significant difference on weight loss between two groups (P=0.63). Two patients on each group were not evaluable for the early response because of incomplete treatment. The complete response rate at four weeks' follow-up was 80$\~$(16/20) for the radiation therapy alone group and 78$\~$ (11/14) for the radiation therapy and cisplatin group. There was no statistically significant difference in early response between two treatment groups (P=0.126). Conclusion : This study led to the conclusion that the hematologic toxicity from the treatment with concurrent radiation therapy and low dose daily cisplatin seems to be more prominent than that from the treatment of radiation therapy alone. There was no grade 4 hematologic toxicity or mortality in both groups. The hematologic toxicity in both treatment groups seems to be well managable modically. Since the risk factors were not balanced between two treatment groups, the direct comparison of early response of both groups was not possible. However, preliminary results regarding early response for patients with bulky cervical tumor mass treated with radiation therapy and low dose daily cisplatin was encouraging. Longer follow-up is necessary to evaluate the survival data. A phase III study is needed to evaluate the efficacy of concurrent daily low dose cisplatin with radiation therapy in bulky cervical cancer.

  • PDF

Comparison Study of Conventional Film-based and CT-reconstruction method in HDR Brachytherapy (고선량률 근접 방사선 치료에서 기존의 필름 방법과 CT 재구성 방법의 비교 연구)

  • 장지나;이형구;윤세철;서태석
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.63-69
    • /
    • 2004
  • HDR brachytherapy administers a large dose of radiation in a short time compare with LDR, and its optimization for treatment is related to several complex factors, such as physical, radiation and optimization algorithms, so there is a need for these to be verified for accurate dose delivery. In our approach, a previous study concerning the phantom for dose verification has been modified, and a new pelvic phantom fabricated for the purpose of localization, including a structure enabling the use of a CT or MRI system. In addition, a comparison study was performed to verify an orthogonal method that is commonly used for brachytherapy localization by comparing target coordinates from a CT system. Since the developed phantom was designed to simulate the clinical setups of cervix cancer, it included an air-filled bladder and a rectum structure shaped sphere and cylinder An N-shaped localizer was used to obtain precision coordinates from both CT and films. Moreover, the IDL 5.5 software program for Windows was used to perform coordinates analysis based on an orthogonal algorithm. The film results showed differences within 1.0 mm of the selected target points compare with the CT coordinates. For these results, a Plato planning system (Nucletron, Netherlands) could be independently verified using this phantom and software. Furthermore, the new phantom and software will be efficient and powerful qualify assurance (QA) tools in the field of brachytherapy QA.

  • PDF

Literature Analysis of Radiotherapy in Uterine Cervix Cancer for the Processing of the Patterns of Care Study in Korea (한국에서 자궁경부알 방사선치료의 Patterns of Care Study 진행을 위한 문헌 비교 연구)

  • Choi Doo Ho;Kim Eun Seog;Kim Yong Ho;Kim Jin Hee;Yang Dae Sik;Kang Seung Hee;Wu Hong Gyun;Kim Il Han
    • Radiation Oncology Journal
    • /
    • v.23 no.2
    • /
    • pp.61-70
    • /
    • 2005
  • Purpose: Uterine cervix cancer is one of the most prevalent women cancer in Korea. We analysed published papers in Korea with comparing Patterns of Care Study (PCS) articles of United States and Japan for the purpose of developing and processing Korean PCS. Materials and Methods: We searched PCS related foreign-produced papers in the PCS homepage (212 articles and abstracts) and from the Pub Med to find Structure and Process of the PCS. To compare their study with Korean papers, we used the internet site 'Korean Pub Med' to search 99 articles regarding uterine cervix cancer and radiation therapy. We analysed Korean paper by comparing them with selected PCS papers regarding Structure, Process and Outcome and compared their items between the period of before 1980's and 1990's. Results: Evaluable papers were 28 from United States, 10 from the Japan and 73 from the Korea which treated cervix PCS items. PCS papers for United States and Japan commonly stratified into $3\~4$ categories on the bases of the scales characteristics of the facilities, numbers of the patients, doctors, Researchers restricted eligible patients strictly. For the process of the study, they analysed factors regarding pretreatment staging in chronological order, treatment related factors, factors in addition to FIGO staging and treatment machine. Papers in United States dealt with racial characteristics, socioeconomic characteristics of the patients, tumor size (6), and bilaterality of parametrial or pelvic side wail invasion (5), whereas papers from Japan treated of the tumor markers. The common trend in the process of staging work-up was decreased use of lymphangiogram, barium enema and increased use of CT and MRI over the times. The recent subject from the Korean papers dealt with concurrent chemoradiotherapy (9 papers), treatment duration (4), tumor markers (B) and unconventional fractionation. Conclusion: By comparing papers among 3 nations, we collected items for Korean uterine cervix cancer PCS. By consensus meeting and close communication, survey items for cervix cancer PCS were developed to measure structure, process and outcome of the radiation treatment of the cervix cancer. Subsequent future research will focus on the use of brachytherapy and its impact on outcome including complications. These finding and future PCS studies will direct the development of educational programs aimed at correcting identified deficits in care.

Design of a New Applicator for High-Dose Rate Vaginal Brachytherapy (고선량율 질강 근접조사를 위한 새로운 적용구의 제작)

  • Shin, Sei One
    • Journal of Yeungnam Medical Science
    • /
    • v.17 no.2
    • /
    • pp.123-128
    • /
    • 2000
  • Purpose: This study was aimed to develop a new vaginal applicator(Shin's Applicator) for 2-channel high-dose rate vaginal brachytherapy to evaluate uniformity of surface dose, and to present 3-dimensional dose distribution of the applicator. Methods: Shin's Applicator was inexpensively constructed using human soft tissue equivalent acrylic bar. We evaluated dose uniformity along the applicator surface using film densitometer and performed vaginal intracavitary brachytherapy after insertion of the applicator using HDR brachytherapy planning software and brachytherapy unit(Ralstron-20B). Results: Shin's Applicator allows improved dose distribution than the existing 1-channel cylinder and achieves diminished urinary bladder and rectal dose by 20%. Conclusions: From the above results, it can be concluded that Shin's Applicator may be an improved form of a vaginal applicator. Furthermore, it can be suggested that this applicator has an advantage, for it prevents vaginal stenosis after radiation therapy and can be used as a disposable vaginal dilator. Further follow up examination with radiological study may be helpful to evaluate the therapeutic efficacy of this applicator.

  • PDF

Radiotherapy Results in Stage IIB Uterine Cervix Cancer (자궁경부암 병기 IIB의 방사선치료결과)

  • Kil Whoon Jong;Chun Mison;Kang Seunghee;Oh Young Taek;Ryu Hee Sug;Ju Hee Jae;Lee Eun Ju
    • Radiation Oncology Journal
    • /
    • v.19 no.4
    • /
    • pp.345-352
    • /
    • 2001
  • Purpose : To evaluate the treatment results and prognostic factors after radiotherapy in stage IIB uterine cervix cancer. Materials and methods : We retrospectively analyzed the records of 90 patients with stage IIB uterine cervix cancer who received radiotherapy between 9/94 and 12/99. Age was ranged from 28 to 79 years (median 57). Tumor size was $\geq4\;cm$ in 64 patients. Preteatment SCC level was measured in 75 patients. Twenty nine patients received conventional radiotherapy (QD) and the others received modified hyper-fractionated radiotherapy (BID). Only 7 patients in BID had tumor size <4 cm. All patients received high dose rate brachytherapy $(4\;Gy\times7\;or\;5\;Gy\times6)$. No Patient received concurrent chemotherapy during radiotherapy. Follow up period was ranging from 9 to 76 months (median 38). Results : The 5-year overall and disease free survival rates were $73.4\%\;and\;71.6\%$, respectively. Local recurrences occurred in $10\%$ of patients, and distant metastasis in $18.9\%$. There was a significant correlation between OS/DFS and tumor size $(<4cm;\;OS\;95.2\%,\;DFS\;91.4\%,\;\geq4cm;\;OS\;63.4\%,\;DFS\;63.4\%)$. Pretreatment SCC level was one of prognostic factors only in univariate analysis. Conclusion : With modified hyperfractionated radiotherapy, there was very low local recurrence rate $(6.6\%)$ and high 5-year overall and disease free survival rate $(75.4\%\;and\;70.5\%)$, which is comparable to results after concurrent chemoradiotherapy in bulky, locally advanced stage IIB uterine cervix cancer.

  • PDF

Dose Distribution&Calibration in HDR Intracavitary Irradiation for Uterine Cervical Cancer (자궁경부암의 강내치료를 위한 선량측정)

  • 김진기;김정수;김형진;권형철
    • Progress in Medical Physics
    • /
    • v.6 no.1
    • /
    • pp.13-18
    • /
    • 1995
  • Dose distribution of HDR-RALS source represents an inverse square law as the distance. Difference of measurement value and calculation value according of brachytherapy. Therefore, in HDR-RALS dose calibration and calculation have an important effect in treatment of uterine cervical cancer and absorbed dose of interesting points. In intracavitary therapy, particula attention is paid for precise determination of the doses to be applied. In this report, we have discussed that the calibration of a HDR-RALS, differences between calculation dose use of isodose chart and measurement in rectum. Dose rate calibration of radiation sources are obtained from air kerma and Г factor with calibraed ion chamber for cobalt source. and used semiconductor detector for compared with measurement in phantom. Eighteen patients were treated with a HDR-RALS for intrcavitarty irradiation (ICR) using a cobalt-cesium source. Repoductivity of dose measurements were 0.3 -1.1% in phantom. The means of dose distribution was -6- +21% between calculation of isodose chart and measurement of recyum, and was same mean value upper 6.3% in measurement value than calculation does.

  • PDF

Accelerated Hyperfractionated Radiotherapy for Locally Advanced Uterine Cervix Cancers (국소진행된 자궁경부암에서의 가속과분할 방사선치료)

  • Seo, Young-Seok;Cho, Chul-Koo;Yoo, Seong-Yul;Kim, Mi-Sook;Yang, Kang-Mo;Yoo, Hyung-Jun;Choi, Chul-Won;Lee, Kyung-Hee;Lee, Eui-Don;Rhu, Sang-Young;Choi, Suck-Chul;Kim, Moon-Hong;Kim, Beob-Jong
    • Radiation Oncology Journal
    • /
    • v.26 no.1
    • /
    • pp.24-34
    • /
    • 2008
  • Purpose: To assess the efficacy of the use of accelerated hyperfractionated radiotherapy(AHRT) for locally advanced uterine cervix cancers. Materials and Methods: Between May 2000 and September 2002, 179 patients were identified with FIGO stage IIB, IIIB, and IVA cancers. Of the 179 patients, 45 patients were treated with AHRT(AHRT group) and 134 patients were treated with conventional radiotherapy(CRT group), respectively. Patients undergoing the AHRT regimen received a dose of 30 Gy in 20 fractions(1.5 $Gy{\times}2$ fractions/day) to the whole pelvis. Subsequently, with a midline block, we administered a parametrial boost with a dose of 20 Gy using 2 Gy fractions. Patients also received two courses of low-dose-rate brachytherapy, up to a total dose of 85{\sim}90 Gy to point A. In the CRT group of patients, the total dose to point A was $85{\sim}90$ Gy. The overall treatment duration was a median of 37 and 66 days for patients that received AHRT and CRT, respectively. Statistical analysis was calculated by use of the Kaplan-Meier method, the log-rank test, and Chi-squared test. Results: For patients that received cisplatin-based concurrent chemotherapy and radiotherapy, the local control rate at 5 years was 100% and 79.2% for the AHRT and CRT group of patients, respectively(p=0.028). The 5-year survival rate for patients with a stage IIB bulky tumor was 82.6% and 62.1% for the AHRT group and CRT group, respectively(p=0.040). There was no statistically significant difference for severe late toxicity between the two groups(p=0.561). Conclusion: In this study, we observed that treatment with AHRT with concurrent chemotherapy allows a significant advantage of local control and survival for locally advanced uterine cervix cancers.

Comparison of Dose When Prescribed to Point A and Point H for Brachytherapy in Cervical Cancer (자궁경부암 근접치료에서 A점과 H점을 이용한 치료계획 시 선량 비교)

  • Gang, Ji-Hyeong;Gim, Il-Hwan;Hwang, Seon-Boong;Kim, Woong;Im, Hyeong-Seo;Gang, Jin-Mook;Gim, Gi-Hwan;Lee, Ah-Ram
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.61-66
    • /
    • 2012
  • Purpose: The purpose of this study is to compare plans prescribed to point A with these prescribed to point H recommended by ABS (American Brachytherapy Society) in high dose rate intracavitary brachytherapy for cervical carcinoma. Materials and Methods: This study selected 103 patients who received HDR (High Dose Rate) brachytherapy using tandem and ovoids from March 2010 to January 2012. Point A, bladder point, and rectal point conform with Manchester System. Point H conforms with ABS recommendation. Also Sigmoid colon point, and vagina point were established arbitrarily. We examined distance between point A and point H. The percent dose at point A was calculated when 100% dose was prescribed to point H. Additionally, the percent dose at each reference points when dose is prescribed to point H and point A were calculated. Results: The relative dose at point A was lower when point H was located inferior to point A. The relative doses at bladder, rectal, sigmoid colon, and vagina points were higher when point H was located superior to point A, and lower when point H was located inferior to point A. Conclusion: This study found out that as point H got located much superior to point A, the absorbed dose of surrounding normal organs became higher, and as point H got located much inferior to point A, the absorbed dose of surrounding normal organs became lower. This differences dose not seem to affect the treatment. However, we suggest this new point is worth being considered for the treatment of HDR if dose distribution and absorbed dose at normal organs have large differences between prescribed to point A and H.

  • PDF