• Title/Summary/Keyword: 자가 계측

Search Result 614, Processing Time 0.027 seconds

Development of Real Time Smart Structure Monitoring System for Bridge Safety Maintenance using Sensor Network (센서 네트워크 기반 실시간 교량 안전관리를 위한 지능형 구조 건전성 모니터링시스템 개발)

  • Jo, Byung-Wan;Kim, Heon;Lee, Yun-Sung;Kim, Do-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.2
    • /
    • pp.221-230
    • /
    • 2016
  • As structures' long term performances and users' safety have been highlighted, a new maintenance technique using IT has drawn attention around the globe. Therefore, throughout the paper, by analyzing bridge's static and dynamic data using wireless measuring sensor, a "real time smart bridge monitoring system" has developed. Smart bridge monitoring system is consists of three main parts a sensor that can measure major members' movement, a wireless system that informs the data from the sensor, and the database system that analysis the data. In order to test the performance of the system, five different were placed on the Olympic Bridge, Seoul. The power system of the sensors was replaced by self-sustain solar energy system. In order to validate data from the real time smart bridge monitoring system, the data was collected for a week from both wireless system and the wired system and the two data were compared to see the relevance.

The Case Study of consistency and calculus using Holland's Hexagonal model on the career indecisive clients (우유부단형 내담자의 홀랜드 6각형 모형 일관성 및 계측성 사례연구)

  • Kim, Byung-Suk;Lee, Joon-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.828-837
    • /
    • 2014
  • The purpose of this study is to investigate the versatility of indecisive clients which is one of the seven key factors to identify indecisiveness by analyzing Holland's 3-letter code with consistency and calculus. By implementing the method of Occupational Card Sort, all six clients showed low consistency in the three codes as well as between the first code and their thesis statements. They also showed mismatching of three codes evaluated with the thesis statements. From observing calculus from the hexagonal model, all six Holland codes showed balanced development and similarity of calculus between the codes in adjacent. The result of the study finds that various interests may cause indecision in one's career decision-making.

A STUDY ON THE ERRORS UN THE CEPHALOMETRIC MEASUREMENTS (두부방사선사진의 계측오류에 관한 연구)

  • Na, Kwang-Cheon;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.28 no.1 s.66
    • /
    • pp.75-83
    • /
    • 1998
  • This study was done to recognize the importance of errors in measurements of cephalometric radiograph and to find the anatomical structures those need special care to select as a reference points through the detection of the systematic errors and estimation of random errors. For this purose, 100 cephalometric radiographs were prepared by usual manner and 61 reference points, and 130 measurement variables were established. Measurement errors were detected and estimated by the comparison of the 25 randomly-selected samples for repeated measurements with the main sample. The following results were obtained : 1. In comparison of the repeated measurements, there were statistical significant differences in 24 variables which were 18.4% of 130 total variables. 2. The frequency of the difference in identification of the reference points between the repeated measurements was very high in the root apex of upper incisor(as), the most posterior wall of maxilla(tu), soft tissue nasion(n'), soft tissue frontal eminence(ft), and ad3 in airway. 3. After correction of reference points marking until the level of below 5% significance, the range of random errors were from 0.67 to 1.71 degree or mm. 4. The variable shown the largest random error was the interincisal angle(ILs-ILi). 5. Measurement errors were mainly caused by the lack of precision in anatomic definitions and obscure radiographic image. From the above results, the author could find the high possibility of errors in cephalometric measurements and from this point, we should include error analysis in all the studies concerning measurments. In is essential to have a concept of error analysis not only for the investigator but also for a reader of other articles.

  • PDF

Accuracy of dental model based on the state-of-the-art manufacturing technique (첨단 제조기술 기반으로 제작된 치과용 모형의 정확도에 관한 연구)

  • Kim, Jae-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.693-700
    • /
    • 2020
  • This study compared the accuracy and reliability of definitive casts fabricated from a digital impression and conventional impression technique. A master model with the prepared upper full-arch tooth was used. Samples of ten plaster models and ten polyurethane models were duplicated using a selected standard master model. Six linear measurements were recorded between the landmarks, directly on each of the stone models and the polyurethane models on two occasions by a double examiner. The Wilcoxon signed-rank test, interclass correlation coefficient (ICC), measurement error (MSE), and limit of agreement (LoA) were used for statistical analysis. The ICC ranged from 0.76 to 0.99 when comparing the stone models and polyurethane models. The mean difference between the stone models and polyurethane models ranged from 0.09mm to 0.20mm, suggesting that stone models might be slightly larger than polyurethane models. Based on this study, the accuracy of the polyurethane models in evaluating the performance of an oral scanner and subtractive technology was acceptable. Further studies will be needed on patient subjects under clinical conditions that may involve missing or malpositioned teeth and fixed dental prostheses because this study was limited to use a standard master model and duplicated sample models in a laboratory setting.

해외리포트 - 편광소자의 광학특성의 한계

  • Toda, Shin-ichiro
    • The Optical Journal
    • /
    • s.122
    • /
    • pp.44-49
    • /
    • 2009
  • 이번호에는 광기술컨텍트 2009년 5월호 <특집:광학기술의 한계>에서 Toda Shin-ichiro씨가 기고한 '편광소자의 광학특성의 한계' 내용을 번역하여 게재한다. 최근 노광기, 광기록을 비롯하여 레이저 가공, 광계측 등 여러 분야에 걸쳐 광원파장의 단파장화가 진행되고 있다. 이러한 상황 속에서 광학부품의 하나인 편광자의 자외화(紫外化)에 대한 필요성이 요구되고 있다. 성능적으로 밸런스가 좋은 편광자로 글랜 톰슨 프리즘을 들 수 있는데 본 고에서는 글랜 톰슨 프리즘 구조에서 파장 $\lambda$=1800nm부터 사용 가능하고 투과율도 높은 편광자와 그 제작 시의 문제점에 대해 설명하고 있다.

  • PDF

A study on the 3-D standard value of mandible for the diagnosis of facial asymmetry (안면비대칭 진단을 위한 하악골 3차원영상 계측기준치에 관한 연구)

  • Ahn, Jeong-Soon;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.35 no.2 s.109
    • /
    • pp.91-105
    • /
    • 2005
  • For af accurate diagnosis and treatment planning of facial asymmetry, the use of 3-dimensional (3-D) image is indispensable. The purpose of this study was to get standard data for the 3-D analysis of facial asymmetry Computerized tomography (CT) was taken in the 60 normal occlusion individuals (30 male. 30 female) who did not have any apparent facial asymmetry. The acquired 2D CT DICOM data were input on a computer, and the reformatted 3-D images were created using a 3-D image software. Twenty three measurements were established in order to evaluate asymmetry; 15 ;omear measurements (6 for ramus length. 1 for condylar neck length, and 8 for mandibular body length) and 8 angular measurements (4 for gonial angle. 2 for frontal ramal inclination. and 2 for lateral ramal inclination) The right aid left difference of each measurement was calculated and analyzed. It is suggested that the right and left differences of the measurements obtained from the study could be used as references for the diagnosis of facial asymmetric patients.

The correlation between dental compensation and craniofacial morphology in skeletal Class III malocclusion (골격성 III급 부정교합자의 치성보상과 두개안면골격의 상관관계에 관한 연구)

  • Jeon, Young-Jin;Park, Su-Byung;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.27 no.2
    • /
    • pp.209-219
    • /
    • 1997
  • This investigation was designed to analyze the degree of dental compensation according to horizontal components of craniofacial skeleton and to investigate correlation between dental compensation and craniofacial pattern in skeletal class III malocclusion. The material selected for this study consisted of standard lateral cephalogram of 59 subjects in normal occlusion group, 91 subjects in mild skeletal class III malocclusion group and 58 subjects in severe skeletal class III malocclusion group. The mild skeletal class III malocclusion group was divided into two groups, one was class III malocclusion without anterior crossbite group and the other was class III malocclusion with anterior crossbite group. The data were analyzed by Quick-ceph image program. The results were as follows. 1. Mild skeletal class III malocclusion without anterior crossbite group showed the most labial inclination of upper incisors, followed by severe skeletal class III malocclusion group and mild skeletal class III malocclusion with anterior crossbite group, the Latter showing the least. The amount of lingual inclination of lower incisors was the largest in severe skeletal class III malocclusion group, and there was no statistically significant difference between mild skeletal claw III malocclusion without anterior crossbite group and mild skeletal class III malocclusion with anterior crossbite group. 2. There were little differences in vertical skeletal structure between mild skeletal class III malocclusion without anterior crossbite group and mild skeletal class III malocclusion with anterior cwssbite group, they showed statistically significant differences in the upper incisors measurements. 3. The measurements of lower incisors in mild skeletal class III malocclusion without anterior crossbite group and upper incisors in mild skeletal class III malocclusion with anterior crossbite group represented a high correlation with skeletal structure. Especially, ∠IMPA and ∠FMIA of lower incisor measurements, and ∠U1-FH ∠U1-SN of upper incisor measurements showed high correlation with skeletal structure in each group. 4. ∠IMPA and ∠FMIA of lower incisor measurements showed high correlation with skeletal structure in all groups. ∠U1-FH, ∠U1-SN and U1-facial plane(mm) of upper incisor measurements represented higher correlation with skeletal structure than any other upper incisor measurements.

  • PDF

Automatic measurement of voluntary reaction time after audio-visual stimulation and generation of synchronization and generation of synchronization signals for the analysis of evoked EEG (시청각자극후의 피험자의 자의적 반응시간의 자동계측과 유발뇌파분석을 위한 동기신호의 생성)

  • 김철승;엄광문;손진훈
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2003.05a
    • /
    • pp.36-40
    • /
    • 2003
  • 근래에 들어 질병으로 인하여 의사표현이 곤란한 환자에게 뇌파에 기초한 BCI(Brain Computer Interface)와 같은 새로운 인터페이스를 제공하고자 하는 연구가 활발히 진행되고 있다. BCI를 위한 기초 연구로서 특정 자극에 대해 유발되는 뇌파의 측정과 분석은 BCI를 위한 뇌파의 패턴과 인터페이스의 설계에 중요한 역할을 한다. 이 연구의 목적은 시청각 자극 인가후 피험자의 반응 시간을 측정하는 시스템을 EEG와 같은 생체 신호 계측 시스템과 연동이 가능한 형태로 개발하는 것이다. 제안된 시스템은 기능적으로 자극 신호 발생부, 반응시간 측정부, 유발뇌파 측정부, 동기신호발생부로 나뉘어진다. 자극신호 발생부는 실험에 이용되는 자극신호를 제작하는 부분으로서 Flash를 사용하여 구현하였다. 반응시간 측정부는 문제에 대한 답 선택 요청시각으로부터 피험자의 반응까지의 시간을 측정하는 부분으로서 마이크로 컴퓨터(80C31)를 이용하여 구현하였다. 우발뇌파 측정부는 시판용 하드웨어와 소프트웨어를 그대로 사용하였다. 동기신호 발생부는 전체 시스템의 동기를 맞추기 위한 신호를 발생하는 부분으로서 문제제시, 답요구와 동기한 화면상의 명암 신호와 이를 검출하는 광센서로 구성하였다. 본 논문에서 제시한 방법에서는 기존의 유발진위 측정 및 자극시스템에 특정 모듈(반응시간 측정 장치, 동기신호 발생장치)만을 추가하여 실험자의 의도에 맞는 시스템을 설계할 수 있어 유발 뇌파 및 반응시간 측정을 필요로 하는 연구를 가속화 할 것이 기대된다.

  • PDF

Analysis of influence of parameter error for extended EMF based sensorless control and flux based sensorless control of PM synchronous motor (영구자석 동기전동기의 확장 역기전력 기반 센서리스 제어와 자속기반 센서리스 제어의 파라미터 오차의 영향 분석)

  • Park, Wan-Seo;Cho, Kwan-Yuhl;Kim, Hag-Wone
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.8-15
    • /
    • 2019
  • The PM synchronous motor drives with vector control have been applied to wide fields of industry applications due to its high efficiency. The rotor position information for vector control of a PM synchronous motor is detected from the rotor position sensors or rotor position estimators. The sensorless control based on the mathematical model of PM synchronous motor is generally used and it can be classified into back EMF -based sensorless control and magnet flux-based sensorless control. The rotor position estimating performance of the back EMF-based sensorless control is deteriorated at low speeds since the magnitude of back EMF is proportional to the motor speed. The magnitude of the magnet flux for estimating rotor position in the flux-based sensorless control is independent on the motor speed so that the estimating performance is excellent for wide speed ranges. However, the estimation performance of the model-based sensorless control may be influenced by the motor parameter variation since the rotor position estimator uses the mathematical model of the PM synchronous motor. In this paper, the rotor position estimation performance for the back EMF based- and flux-based sensorless controls is analyzed theoretically and is compared through the simulation and experiment when the motor parameters including stator resistance and inductance are varied.