• Title/Summary/Keyword: 잉여전력

Search Result 106, Processing Time 0.027 seconds

A Study on Proposing Practicable Configurations against Propeller Racing for SOFC/GT Hybrid System in Ships (프로펠러 레이싱에 대비한 SOFC/GT 하이브리드시스템의 대책 방안에 관한 기초적 연구)

  • Kim, Myoung-Hwan;Lim, Tae-Woo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.2
    • /
    • pp.256-261
    • /
    • 2008
  • The purpose of this study is to propose practicable configurations against Rapid Load Down like propeller racing of ships which have been using SOFC/GT hybrid system on board. This paper suggests four kinds of countermeasures against propeller racing. The types A and B keep a fixed load of SOFC and save a surplus electric power to a storage system. In types of C and D, the load of SOFC is changed with the propeller racing. The best desirable countermeasure for Rapid Load Down depends upon the size of the ship, the propulsion power, and the characteristics of the engine system.

자동차용 brus less Generator

  • 박양배;나정웅
    • 전기의세계
    • /
    • v.25 no.2
    • /
    • pp.55-57
    • /
    • 1976
  • 자동차에서 발전기는 engine의 기계적 energy를 전기 energy로 변환시켜 engine의 발동, light, radio및 여러가지 계기등에 전류를 공급하며 잉여전력을 축전지에 저장한다. 이러한 자동차용 발전기는 1900년 중반기까지 직류발전기를 사용하였으나 1960년 초기부터 반도체개발과 더불어 저속출력특성이 우수한 교류발전기와 정류기를 병용하였다. 그러나 1960년 하반기부터는 자동차의 고속화, 차내의 라디오, TV시설, 각종 전자제어장치등의 급속한 발달로 보다 안정도가 높은 전원의 공급이 필요하게 되었다. 또한 자동차사용이 일반화됨에 따라 최소의 유지보수를 요하는 발전기를 추구하게 되었다. 이에 따라 미국, 영국, 불란서 등 선진공업국에서는 브러시가 필요없는 발전기의 개발을 서두르게 되었으며 여러가지 형태의 Brushless generator를 개발하여 현재 사용하고 있다. 종래의 발전기에서 Brush와 slip-ring, 즉 금속의 회전마찰접촉을 통하여 계자권선에 전류가 공급됨으로 이에 따른 성능저하, 접촉부분에서 발생하는 arc로 인한 폭발위험 및 전자장치에 주는 방해, Brush 마모로 인한 유지보수등의 단점을 주고 있다.

  • PDF

A Study on the Generation Capacity and Cost Analysis of Solar-Wind Hybrid Power System (태양광-풍력 복합발전시스템의 용량 산정과 경제성 분석에 관한 연구)

  • Kim, Jong-Hwan;Lee, Seung-Chul;Kwon, Byeong-Gook;Oh, Hae-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.348-350
    • /
    • 2003
  • 본 논문에서는 태양광-풍력 복합발전시스템의 발전용량 예측을 통한 시스템 시설투자비 및 발전단가와 경제성에 대하여 분석한다. 도시지역의 일사량 및 풍속 데이터를 기초로 하여 복합발전시스템의 일일 발전량을 구하고, 수용가의 일일부하패턴과 수요부하를 고려하여 태양전지 어레이와 풍력발전기의 용량을 산정한다. 그리고 용량 산정에 따른 복합발전시스템의 초기투자비용과 연간 발전량, 연간 소요경비 등의 요소를 고려하여 총 수명가 분석법(Total Life-Cycle Cost Analysis)에 기초한 발전단가를 계산하고 잉여전력을 계통에 판매할 경우의 경제성을 평가한다.

  • PDF

Automatic Power Supply Time Controller for the Thermal Storage-type Heating Appliances (축열식 난방기기의 심야전력 공급시간 자동제어장치 개발)

  • Kwon S.C.;Han S.H.;Lee H.J.;Park Y.K.;Ko K.J.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.921-924
    • /
    • 2003
  • 한전에서는 수요관리의 하나의 방법으로 심야전력요금제도를 운영하고, 심야축열기기를 보급하여 기저부하증대 및 부하율을 개선하기 위한 많은 노력을 기울이고 있다. 최근 유가상승 등의 원인으로 1999년과 2000년에 심야전력 난방기기의 급격한 보급증가로 인한 심야시간대 동계 최대 전력수요가 발생하여 22시 이후 단시간 부하급증으로 일부지역의 배전선로 회선용량부족 및 부하불평형으로 정전을 유발하게 되는 등 많은 어려움이 발생하였다. 본 논문은 심야수요급증으로 인한 대책의 일환으로 축열식 심야난방기기에 대하여 심야전력의 공급시간 자동제어장치를 개발하였다. 축열 잔열량을 측정하여 그 잉여량 만큼의 시간동안 심야전력의 공급을 지연하여 심야전력 공급초기에 집중되는 심야기기의 가동을 억제하여 심야부하를 분산하게 된다. 이로써 축열식 난방기기에 의한 동계 최대 전력수요 발생을 억제하여, 배전선로의 효율적인 운영에 기여할 것으로 기대된다

  • PDF

Development of Power Supply Time Controller during Off-Peak Period for Thermal-storage Electric Heat Radiator (축열식 전기온풍기의 심야전력 공급시간 자동제어장치 개발)

  • Kwon, Seong-Chul;Han, Seung-Ho;Ko, Kee-Joong;Chung, Woo-Yong;Lee, Hak-Ju;Na, ki-Young
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2334-2336
    • /
    • 2002
  • 한전에서는 수요관리정책의 일환으로 심야전력요금제도를 운영하고, 심야축열기기를 보급하여 기저부하증대 및 부하율을 개선하여 전력공급 원가절감에 노력하여 왔으나, 최근 유가상승 등의 원인으로 1999년과 2000년에 심야전력 난방기기의 급격한 보급증가로 인한 심야시간대 동계 최대 전력수요가 발생하여 22시 이후 단신간 부하급증으로 일부지역의 배전선로 회선용량부족 및 부하불평형으로 정전을 유발하게 되는 등 많은 어려움이 발생하였다. 본 논문은 심야수요급증으로 인한 대책의 일환으로 축열식 심야난방기기의 하나인 축열식 전기온풍기에 대하여 심야전력의 공급시간 자동제어장치를 개발하였다. 축열 잔열량을 측정하여 그 잉여량 만큼의 시간동안 심야전력의 공급을 지연하여 심야전력 공급초기에 집중되는 심야기기의 가동을 억제하여 심야부하를 분산하게 된다. 이로써 축열식 난방기기에 의한 동계 최대 전력수요 발생을 억제하여, 배전선로의 효율적인 운영에 기여할 것으로 기대된다.

  • PDF

Performance of WDM Signals in Optical Links with Random Distribution of Residual Dispersion Per Span only in Half Transmission Section of Total Length (전송 반 구획에서만 중계 구간 당 분산이 랜덤하게 분포하는 광 링크에서의 WDM 신호의 성능)

  • Lee, Seong-Real
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.3
    • /
    • pp.440-448
    • /
    • 2012
  • Optimal net residual dispersion (NRD) and effective launching power range of optical transmission links with optical phase conjugator (OPC) and dispersion management (DM) for compensating the distorted wavelength division multiplexing (WDM) signals due to interaction of group velocity dispersion (GVD) and optical nonlinear effects. WDM systems considered in this research have optical links with the random distribution of residual dispersion per span (RDPS) in each single mode fiber (SMF) spans of only one half transmission section for designing the adaptive optical transmission system configurations. It is confirmed that optimal NRD is 10 ps/nm and effective launching power range is obtained to be -8~1 dBm under NRD = 10 ps/nm in optical links with total dispersion controlled by precompensation. And, it is also confirmed that optimal NRD is -10 ps/nm and effective launching power range is obtained to be -7.5~1 dBm under NRD = -10 ps/nm in optical links with total dispersion controlled by postcompensation.

Optimization of Net Residual Dispersion and Launching Power Depend on Total Transmission Length and Span Length in Optical Transmission Links with Dispersion Management and Optical Phase Conjugation (분산 제어와 광 위상 공액이 적용된 광전송 링크에서 총 전송 거리와 중계 간격에 따른 전체 잉여 분산과 입사 전력의 최적화)

  • Lee, Seong-Real
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.12B
    • /
    • pp.1433-1441
    • /
    • 2011
  • Design rules of optical transmission links with dispersion management (DM) and optical phase conjugation (OPC) for compensating optical signal distortion due to chromatic dispersion and self phase modulation (SPM) of single mode fiber (SMF) are investigated in this paper. Design rules consist of optimal net residual dispersion (NRD) and optimal range of launching power of wavelength division multiplexed (WDM) channels as a function of total transmission length and span length. In all considered total transmission length and span length, optimal NRD are obtained to +10 ps/nm and -10 ps/mn for transmission links, which is controlled by precompensation and postcompensation, respectively. It is confirmed that system performances are more improved and effective NRD for wide launching power have wider range as total transmission length and span length are more decreased.

The Development of Grid-Tied Power Conditioner for RPG Fuel Cell System (가정용 연료전지 시스템의 계통접속을 위한 Power Conditioner 개발)

  • Choi See-Young;Kim Rae-Young;Kwon Hyoung-Nam;Jung Joon-Mo;Suh Inn-yung
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.498-500
    • /
    • 2004
  • 연료전지와 같은 분산전원은 전력계통과 연계 운전함으로 보다 안정된 전원을 얻을 수 있고 그 잉여 전력을 계통에 역송전함으로써 다양한 에너지원의 효율적인 활용도 가능케 하는 이점을 지닌다. 본 논문은 본소에서 개발한 PEMFC형 연료전지 시스템을 위한 1KW급 계통 연계형 인버터를 소개하고, 이의 구성 및 특성을 소개하고자 한다.

  • PDF

Reliability Improvement of H-Bridge Multilevel Inverter for Medium-Voltage & High-Power Induction Motor Drives (고전압 대용량 유도전동기 구동용 H-브릿지 멀티레벨 인버터의 신뢰성 향상)

  • Park, Young-Min;Lee, Kwang-Hwan;Lee, Se-Hyun
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.155-156
    • /
    • 2013
  • 본 논문에서는 고전압 대용량 유도전동기 구동용 H-브릿지 멀티레벨 인버터의 신뢰성 향상을 위한 전력 회로 모듈화, 제어 장치 분산화, 제어기와 통신 이중화, 그리고 Power Cell 고장 발생시 인버터 연속 운전 방법을 소개하였다. 신뢰성 향상을 위해 적용된 방법은 다양한 전압과 용량의 H-브릿지 멀티레벨 인버터를 설계 및 제작하여 각종 부하 실험, 산업 현장 적용을 통해 타당성과 실용성을 입증하였다. 또한 실제 제품 설계, 생산, 판매, 유지 보수 과정을 통해 설계의 유연성, 유지보수의 편리성, 잉여성 확보, 그리고 사용자 요구에 대한 대응성이 우수함을 확인하였다.

  • PDF

A Study on the Power Converter Control of Utility Interactive Photovoltaic Generation System (계통 연계형 태양광 발전시스템의 전력변환기 제어에 관한 연구)

  • Na, Seung-Kwon;Ku, Gi-Jun;Kim, Gye-Kuk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.2
    • /
    • pp.157-168
    • /
    • 2009
  • In this paper, a photovoltaic system is designed with a step up chopper and single phase PWM(Pulse Width Modulation) voltage source inverter. Where proposed Synchronous signal and control signal was processed by one-chip microprocessor for stable modulation. The step up chopper operates in continuous mode by adjusting the duty ratio so that the photovoltaic system tracks the maximum power point of solar cell without any influence on the variation of insolation and temperature because solar cell has typical voltage and current dropping character. The single phase PWM voltage source the inverter using inverter consists of complex type of electric power converter to compensate for the defect, that is, solar cell cannot be developed continuously by connecting with the source of electric power for ordinary use. It can cause the effect of saving electric power. from 10 to 20[%]. The single phase PWM voltage source inverter operates in situation that its output voltage is in same phase with the utility voltage. In order to enhance the efficiency of photovoltaic cells, photovoltaic positioning system using sensor and microprocessor was design so that the fixed type of photovoltaic cells and photovoltaic positioning system were compared. In result, photovoltaic positioning system can improved 5% than fixed type of photovoltaic cells. In addition, I connected extra power to the system through operating the system voltage and inverter power in a synchronized way by extracting the system voltage so that the phase of the system and the phase of single-phase inverter of PWM voltage type can be synchronized. And, It controlled in order to provide stable pier to the load and the system through maintaining high lurer factor and low output power of harmonics.