• Title/Summary/Keyword: 잉여전력

Search Result 106, Processing Time 0.033 seconds

Mid-Span Spectral Inversion Technique in Lumped Dispersion Managed WDM Transmission Systems (집중형 분산 제어 WDM 전송 시스템에서 Mid-Span Spectral Inversion 기술)

  • Lee, Seong-Real
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.1A
    • /
    • pp.7-15
    • /
    • 2008
  • In this paper, it is investigated that the limitation due to the asymmetry of optical power with respect to optical phase conjugator(OPC) in mid-span spectral inversion(MSSI) for compensating optical signal distortion due to group velocity dispersion(GVD) and nonlinearities generated in fiber by combining with lumped dispersion management(DM) technique into MSSI. Two kinds of lumped DM configuration(configuration A and configuration B) are considered and compared each other in this research. Configuration A consists of two dispersion compensating fiber(DCF) span positioned after transmitter and before receiver, respectively. Configuration B consists of two dispersion compensating fiber(DCF) span positioned before and after OPC placed at middle of total transmission link, respectively. It is confirmed that the transmission performances are more improved by the configuration A combined with MSSI than configuration B. Also, it is confirmed that the best performance of overall channels are obtained by making net residual dispersion(NRD) to have positive value in self phase modulation(SPM)-limited WDM transmission systems, irrelevant to the configuration of DM.

A Study on the Fire Safety Measure of Pumped Storage Power Plant (양수발전소의 화재안전 대책에 관한 연구)

  • Kim, Yoo-Shik
    • Fire Science and Engineering
    • /
    • v.20 no.4 s.64
    • /
    • pp.125-130
    • /
    • 2006
  • Pumped storage power plant is a system of generating electricity with hydroelectric power, in which at times of low electrical demand such as during nights, excess generation capacity of many power plants is used to pump water into the higher reservoir, and when there is higher demand, water is released back into the lower reservoir through a turbine, generating electricity. As pumped storage power plants across the nation are not on building registry under "the Article 6 of the Special Act by the Development of Power Resources", they are classified as a structure, not as a building. As a result, permit of fire protection facility is unnecessary, and fire protection administration is excluded from approval to completion of construction. Therefore, this study is to improve problems in accordance with the application of "he Article 6 of the Special Act by the Development of Power Resources", repair of facilities and problems with safety control to effectively prevent similar damages from repeatedly happening to pumped storage power plants in operation or under construction nationwide during a fire.

Compensation Characteristics Depending on Extinction Ratio of RZ Pulse in Dispersion-managed Link Combined with MSSI (MSSI와 결합된 분산 제어 링크에서 RZ 펄스의 소광비에 따른 보상 특성)

  • Seong-Real Lee
    • Journal of Advanced Navigation Technology
    • /
    • v.28 no.1
    • /
    • pp.123-128
    • /
    • 2024
  • When mid-span spectral inversion (MSSI), which inverts the propagated wave into phase-conjugated wave in the middle of the entire transmission distance, is combined with dispersion-managed link, it is very effective in compensating for the wavelength division multiplexed (WDM) signal distortion due to chromatic dispersion and nonlinear effects. In this MSSI combined dispersion-managed link, the shape of the dispersion map, channel data rate, channel wavelength and wavelength spacing, etc. affect the compensation and, consequently, determine the transmission distance and capacity of the WDM signal. In this paper, the compensation according to the extinction ratio of the return-to-zero (RZ) pulse that constitutes the WDM signal in the MSSI combined distributed control link was numerically analyzed. As a result of the simulation, it was conformed that the extinction ratio to obtain the best compensation should be determined depending on the shape of the dispersion map and the size of the residual dispersion per span, which determines the specific shape of the dispersion map. These results show a significant difference from the results in a general optical transmission system, where as the extinction ratio increases, the power difference between the '1' and '0' signals increases, thereby improving reception performance.

Enhanced Energy Harvester Based on Vibration Analysis of Bicycle Riding (자전거 주행의 진동 분석에 기반한 에너지 수확 증진 기술 개발)

  • Yeo, Jung-Jin;Ryu, Mun-Ho;Kim, Jung-Ja;Yang, Yoon-Seok
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.1
    • /
    • pp.47-56
    • /
    • 2012
  • Bicycle has a large amount of kinetic energy available for energy harvesting technology in its speedy and balanced riding movement. Systematic and realistic analysis of its dynamic property is essential to improve the efficiency of energy harvester. However, there has not been enough researches about precise measurement or analysis of bicycle dynamics on real roads. This study aims to investigate the characteristics of vibrational movement of bicycle using MEMS-based accelerometer and to develop a prototype of electromagnetic energy harvester with nonlinear behavior which is proper to the random vibrations accompanied in bicycle riding. The vibrational components have average magnitude of 1 g and turn out to be independent of riding speed. The developed prototype of energy harvester was installed on a front port of a bicycle to use this ambient vibration and generated an average electrical power of 1.5 mW which is enough to support power for most of portable sensors and short range radio-frequency communication. Further study about isolation of vibration from a rider and conversion efficiency is ongoing. The developed energy harvester is expected to be a platform technology for sustainable portable power supply for various smart IT devices and applications.

Economic analysis of Frequency Regulation Battery Energy Storage System for Czech combined heat & power plant (체코 열병합발전소 주파수조정용 배터리에너지저장장치 경제성 분석)

  • KIM, YuTack;Cha, DongMin;Jung, SooAn;Son, SangHak
    • Journal of Energy Engineering
    • /
    • v.29 no.2
    • /
    • pp.68-78
    • /
    • 2020
  • According to the new climate change agreement, technology development to reduce greenhouse gases is actively conducted worldwide, and research on energy efficiency improvement in the field of power generation and transmission and distribution is underway [1,2]. Economic analysis of the operation method of storing and supplying surplus electricity using energy storage devices, and using energy storage devices as a frequency adjustment reserve power in regional cogeneration plants has been reported as the most profitable operation method [3-7]. Therefore, this study conducted an economic analysis for the installation of energy storage devices in the combined heat and power plant in the Czech Republic. The most important factor in evaluating the economics of battery energy storage devices is the lifespan, and the warranty life is generally 10 to 15 years, based on charging and discharging once a day. For the simulation, the ratio of battery and PCS was designed as 1: 1 and 1: 2. In general, the primary frequency control is designed as 1: 4, but considering the characteristics of the cogeneration plant, it is set at a ratio of up to 1: 2, and the capacity is simulated at 1MW to 10MW and 2MWh to 20MWh according to each ratio. Therefore, life was evaluated based on the number of cycles per year. In the case of installing a battery energy storage system in a combined heat and power plant in the Czech Republic, the payback period of 3MW / 3MWh is more favorable than 5MW / 5MWh, considering the local infrastructure and power market. It is estimated to be about 3 years or 5 years from the simple payback period considering the estimated purchase price without subsidies. If you lower the purchase price by 50%, the purchase cost is an important part of the cost for the entire lifetime, so the payback period is about half as short. It can be, but it is impossible to secure profitability through the economy at the scale of 3MWh and 5MWh. If the price of the electricity market falls by 50%, the payback period will be three years longer in P1 mode and two years longer in P2 and P3 modes.

The Study on the Separation Characteristics of ion with ion Exchange Membrane - I.The Characteristics of ion Exchange Membrane with the Separator of All-Vanadium Redox Flow Battery - (이온교환막을 이용한 이온의 분리특성에 관한 연구 - I. 전바나듐계 레독스-흐름 전지의 격막용 이온 교환막의 특성 -)

  • Kang, An-Soo
    • Applied Chemistry for Engineering
    • /
    • v.4 no.2
    • /
    • pp.393-402
    • /
    • 1993
  • Redox flow secondary battery have been studied actively as one of the most promising electrochemical energy storage devices for a wide range of applications, such as electric vehicles, photovoltaic arrays, and excess power generated by electric power plants. In all-vanadium redox flow battery using solution of vanadium-sulfuric acid as a active material, the difficulty in developing an efficient ion selective membrane can still be identified. The asymmetric cation exchange membrane(M-30) as a separator of all-vanadium redox flow battery which were obtained by the reaction of chlorosulfonation for 30 minutes under the irradiation of UV, showed its superiority in the transport number of 0.94 and electrical resistivity of $0.5{\Omega}{\cdot}cm^2$. The base membrane were prepared by lamination a low density polyethlene film of $10{\mu}m$ thickness on polyolefin membrane(HIPORE 120). The electrical resistivity of M-30 membrane in real solution of vanadium-sulfuric acid was $3.79{\Omega}{\cdot}cm^2$ and it was similar to that of Nafion 117 membrane. Also the cell resistivity was $6.6{\Omega}{\cdot}cm^2$and lower than that of Nafion 117. In considertion of electrochemical properties and costs of membranes, M-30 membrane was better than that of Nafion 117 and CMV of Asahi glass Co. as a separator of all-vanadium redox flow battery.

  • PDF