• Title/Summary/Keyword: 입자충진

Search Result 146, Processing Time 0.032 seconds

Analysis of the particulate matters in the vertical-flow woodchip wetland treating stormwater from paved road (포장도로 강우유출수 처리목적의 수직흐름형 우드칩 충진 습지에서 입자상 물질분석)

  • Yuan, Qingke;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.20 no.2
    • /
    • pp.145-154
    • /
    • 2018
  • In this study, three pilot-scale wetland systems were built for treating stormwater runoff from asphalt road. Each of the system consists of a settling tank and a vertical flow wetland packed with 25%, 50%, and 75% woodchip as treatment media. According to the analysis of the distributions of particle size, it was found that solids ranging in size $0.52-30{\mu}m$ were predominant in the stormwater runoff. After 24-hours settling, those coarser than $20{\mu}m$ were significantly detained. Further retention, especially for the finer-sized fraction, occurred in the wetland through internal recirculation during the dry day periods. As a primary media of the wetland, woodchip showed a high filtration and attachment capacity for the particulates in pre-settled stormwater, whereas overall amount of solids in the wetland effluent increased due to the detachment of woody elements from the media. This was observed mainly during the initial 75 days of operation, and the size and detachment rate were found to be strongly related with the woodchip packing ratio. The mechanism involving woody particle detachment was modeled as a first-order form. In addition, water quality factors and operational parameters affecting the detachment were analyzed and discussed.

Strucural, Thermal, Electrical Characteristics of Epoxy-Nanocomposites according to Dispersion Agent Treatment (분산제 처리에 따른 에폭시-나노콤포지트의 구조적, 열적, 전기적 특성)

  • Park, Jae-Jun;Lee, Sang-Hyup;Kim, Jae-Bong;Lee, Sung-Il
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.256-256
    • /
    • 2009
  • 에폭시수지에 층상실리케이트 나노입자를 충진함량별로 충진시킨 나노콤포지트를 제조하여 충진함량의 변화와 분산제 첨가를 통하여 분산제효과를 조사하였다, 충진함량의 변화는 1, 3, 5, 7, 9wt%과 분산제 변화를 05, 1.5, 2.5wt%로 구조적, 열적, 전기적 특성을 조사하였다. 분산처리는 초음파 기법을 적용하여 분산하였다. 구조적 특성으로 X-RD조사한 결과 0.5wt%분산제처리를 한 경우 완전한 박리를 가져오지 못하였고, 부분적인 박리를 가져왔다. 이는 분산제 처리량이 나노입자 표면정체를 제어할수 없기 때문으로 사료된다. 분산제 1.5wt%를 첨가한경우로 충진함량별 X-RD특성은 1wt%는 완전한 박리를 나타내었고 함량의 증가에 따라 박리정도가 약간 낮아지는 경우를 알 수 있다. 이런 경우 전기적특성중 단시간 절연파괴특성에서 나타내고 있다. 충진함량이 낮을수록 스케일파라미터의 값이 높고, 함량이 증가할수록 낮아지는 경우이다. 이는 분산정도에따라 절연파괴강도에 영향을 주고 있음을 알 수 있다. 열적특성에서 유리천이온도는 1,3,5wt%에서는 증가하는 결과를 더욱 충진함량이 증가하면 오히려 감소되는 특성을 나타내고 있다. 결국은 분산정도에따라 전기적 특성 및 열적특성이 크게 변화되는 특성을 나타내었다.

  • PDF

Polymer형 내열성 PTC 소재의 특성 연구

  • 강영구;곽봉신
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1999.06a
    • /
    • pp.249-252
    • /
    • 1999
  • 전도성 충진제가 포함된 결정성 고분자내에 대전류가 흐르게 될 경우 Joule 효과로 소재자체의 발열현상이 발생하며 온도가 증가함에 따라 고분자의 용융점 부근에서 급격한 열팽창으로 인하여 고분자 내에 분포되어 있던 전도성 충진재 입자사이의 간격이 증가하게 되며 전자들의 흐름이 방해를 받게 된다. 이에 따라 전기저항이 커져 전류의 흐름이 감소되는 철상이 발생하며 이를 PTC(Positive Temperature Coefficient)라 하고 온도 증감에 따른 전도성 충진제 간의 electron tunnelling과 고분자의 결정변화에 의해 민감한 전기저항변화 특성을 나타낸다. (중략)

  • PDF

연구로용 $U_3$ Si/Al 핵연료 분말 혼합체의 균질도 평가 기술 개발

  • 손웅희;홍순형;김창규;김기환;고영모
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.256-261
    • /
    • 1998
  • Uranium silicide는 우수한 조사안정성을 가지는 유망한 연구로용 저농축 분산형 핵연료 소재이나 상대적으로 낮은 uranium 함량으로 인해 고출력에 필요한 8~9g-U/㎤ 정도의 uranium 충진 밀도를 얻기 위해서는 Al기지내에 uranium silicide 핵연료 입자의 부피분율을 높여주는 것이 필요하다 핵연료 입자의 부피분율을 높이기 위하여는 핵연료봉의 Al 기지내에 핵연료 입자가 균일하게 분포되어야 한다. 균질한 핵연료 심재를 제조하기 위해서는 핵연료 입자와 알루미늄과의 균일한 혼합이 중요하며 이러한 혼합체내의 분말에 대한 균질도를 정확히 평가하는 방법의 개발이 필요하다. 본 연구에서는 혼합분말의 충진시 겉보기 밀도 측정을 통한 조성의 표준편차를 구하는 방법과 X-ray image 분석법을 새로운 균질도 평가방법으로 제시하였다. 구형의 U$_3$Si분말과 Al분말의 혼합시 drum 회전법의 경우에는 밀도차에 의한 segregation이 발생되고 있으나, Spex mill 혼합법의 경우에는 균질도가 향상되었다. 45-150$\mu\textrm{m}$의 분말크기 분포를 갖는 구형 U$_3$Si의 경우가 작은 입자들이 큰 입자들 사이를 효과적으로 채울 수 있기 때문으로 균일한 분포를 갖는 것으로 생각되며, 밀도차가 큰 U$_3$Si의 경우는 밀도차가 작은 구형 Cu-Sn 혼합체에 비해 균질도가 저하됨을 확인하였다. 겉보기 밀도 측정에 의한 균질도 측정평가와 X-ray image 분석법과의 관계에서는 같은 경향성을 찾을 수 있었다.

  • PDF

Analysis of electrical resistivity characteristics according to the mixing ratio of coarse fillings in artificial rock joint (인공 암반절리의 조립토 충진물 혼합비에 따른 전기비저항 특성 분석)

  • Haeju Do;Tae-Min Oh;Hangbok Lee
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.25 no.2
    • /
    • pp.141-155
    • /
    • 2023
  • Monitoring technology based on electrical resistivity is widely used for non-destructive data collection and health analysis of underground structures and tunnels. Vulnerable sections such as fault zone generates many problems during construction of the tunnel. These problems cause displacement and stress changes of the ground. Therefore, it is necessary to predict the state of the fault zone section to ensure the mechanical stability of the underground structure. Monitoring the size of joints and the porosity of the fillings is essential for rocks. Previous studies have not considered the variety of fillings in rock joints. In this study, electrical resistivity tests were conducted according to the particle mixing state of the sandy fillings. When the size of fillings is decreased at the constant porosity, the electrical resistivity tends to increase. The results of this study are expected to be useful as basic electrical resistivity data for predicting the ground conditions and evaluation of the ground behavior that is containing sandy fillings in the rock joint for tunnels.

An Exprimental Study on the Heat Transfer Performance in a Fluidized Bed Double Pipe Heat Exchanger (수직이중관식(垂直二重管式) 유동층형(流動層形) 열교환기(熱交換器)의 전열성능(傳熱性能)에 관한 실험적(實驗的) 연구(硏究))

  • Yoo, Ji-Oh;Seo, Jeong-Yun
    • Solar Energy
    • /
    • v.14 no.2
    • /
    • pp.39-50
    • /
    • 1994
  • Experiments have been conducted to measure the heat transfer coefficient and pressure drop in fluidized bed double pope heat exchangers with smooth tube and longitudinal finned tube. The effect of particle size(alumina beads; do=0.41, 0.54, 0.65, 0.77 mm) and static bed height on the heat transfer coefficient has been evaluated in terms of pumping power. The heat transfer coefficient for the smooth tube and finned tube heat exchangers has been compared with single phase double pipe heat exchanger. Results show that the heat transfer coefficients for the finned tube in $2.96{\sim}3.45$ times higher than the smooth tube. The heat transfer coefficients for the fluidized bed heat exchanger is higher than the single phase heat exchanger for the most of pumping power range tested. The maximum increase in the heat transfer coefficient for fluidized bed is 91.3% for the smooth tube and 127.1% for the finned tube.

  • PDF

AC Insulation Breakdown Weibull Plot Characteristics of Epoxy-Nanocomposites (에폭시-나노콤포지트의 교류절연파괴 와이블 분포특성)

  • Park, Jae-Jjjun;Cho, Dae-Ryung;Lee, Chang-Hoon;Kim, Jung-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.384-384
    • /
    • 2009
  • 에폭시 수지에 유기화된 층상실리케이트 나노입자를 1wt% 충진한 경우 나노콤포지트와 마이크로 입자를 50wt% 충진한 경우 마이크로 콤포지트를 제조하였다. 초음파 분산법을 이용하여 나노 및 마이크로입자를 120분 동안 분산시킨 에폭시- 나노/마이크로 콤포지트이다. 나노콤포지트와 마이크로콤포지트의 단시간 교류절연파괴특성을 조사하기 위해 와이블 분포 plot을 통하여 나타내었다. 와이블 plot은 기울기로서 형상파라미터를 나타낸 경우로서 이는 파괴강도의 균질성을 의미하게 된다. 63.2% 누적분포함수를 나타낸 경우 척도파라미터로서 나타내어진다. 마이크로 콤포지트의 경우 형상파라미터가 2.99, 나노콤포지트는 8.96를 나타내었다. 또한 마이크로 콤포지트 및 나노콤포지트 스케일 파라미터는 164.25kV/mm, 245kV/mm를 얻었다. 또한 B10수명의 경우 마이크로콤포지트와 나노콤포지트의 경우 77.57kV/mm, 139.3 6kV/mm로서 나노콤포지트의 경우 완전하게 박리가 일어난 경우이다. 마이크로 입자를 분산시켜 입자간거리와 나노입자를 분산시켜 박리가 일어난 경우 입자간거리는 대단히 큰 차이를 나타내고 있다. 나노입자가 교번전계 하에서 주입된 전하 및 케리어 이동을 억제하는 경우로 이와같은 결과를 얻을 수 있다.

  • PDF

An Experiment on the Particle Collection Characteristics in a Packed Wet Scrubber (충진층식 세정집진기의 집진특성 실험)

  • 유경훈;노희환;최은수;김종균
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.4
    • /
    • pp.305-311
    • /
    • 2003
  • DOP aerosol particles with geometric mean diameter of 0.5-3.0 ${\mu}{\textrm}{m}$, geometric standard deviation of 1.1-1.3 and total number concentration of 1,500-8,000 Particles/㎤ were used to determine collection efficiencies of a packed wet scrubber with respect to particle size. The tested operating variables included air velocity and water injection rate. It was shown from the experimental results that the collection efficiencies increased with increasing water injection rate and decreasing air velocity. Meanwhile, as for the particle size variation, all of the collection efficiency curves increased rapidly between 0.57-1.41${\mu}{\textrm}{m}$ for the range of water injection rate above 30 L/min. It was also seen that the collection efficiency of a packed wet scrubber is mainly governed by the mechanism of inertial impaction.