• Title/Summary/Keyword: 입자(particulate)

Search Result 858, Processing Time 0.023 seconds

The Effect of Fuel Sulfer on Particulate Matter of Diesel Engine Equipped with Oxidation Catalyst (경유 중 황이 산화촉매 장착 디젤엔진의 입자상 물질에 미치는 영향)

  • 조강래;신영조;류정호;김희강
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.6
    • /
    • pp.487-495
    • /
    • 1997
  • The most desirable diesel oxidation catalyst (DOC) should have the properties of oxidizing CO, HC and SOF effectively at low exhaust gas temperature while minimizing the formation of sulfate at high exhaust gas temperature. Precious metals such as platinum and palladium have been known to be sufficiently active for oxidizing SOF and also to have high activity for the oxidation of sulfur dioxide $(SO_2)$ to sulfur trioxide $(SO_3)$. There is a need to develop a highly selective catalyst which can promote the oxidation SOF efficiently, on the other hand, suppress the oxidation of $SO_2$. In this study, a Pt-V catalyst was prepared by impregnating platinum and vanadium onto a Ti-Si wash coated ceramic monolith substrate. A prepared Pt-V catalytic converter was installed on a heavy duty diesel engine and the effect of fuel sulfur on particulate matter (PM) of heavy duty diesel engine was measured. The effect of fuel sulfur on PM of Pt-V was also compared with that of a commercialized Pt catalyst currently being used in some of the heavy duty diesel engines in advanced countries. Only 1 $\sim$ 3% of sulfur in the diesel fuel was converted to sulfate in PM for the engine without catalyst, but almost 100% of sulfur conversion was achieved for the engine with Pt catalyst at maximum loading condition. In the case of Pt-V catalyst, there was no big difference in conversion with the base engine even at maximum loading condition. The reason of SOF increase according to the increase of suflate emission was identified as the washing off effect of bound water in sulfate.

  • PDF

Prediction of Characteristics for the Air-side Particulate Fouling in Finned-Tube Heat Exchangers of Air Conditioners used in the Field (실공간 사용 공기조화기용 열교환기의 공기측 파울링 특성 예측)

  • Ahn, Young-Chull;Jung, Sung-Hak;Hwang, Yu-Jin;Lee, Chang-Gun;Kim, Doo-Hyun;Jung, Seong-Ir;Lee, Jae-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.8
    • /
    • pp.563-568
    • /
    • 2007
  • The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performances of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. An empirical modeling equation has been derived from the experimental results using accelerated tests and it showed good predictions of the fouling characteristics of the slitted finned tube heat exchangers. However the modeling equation predicts only the fouling characteristics of new heat exchangers and it can not predicts fouling characteristics obtained from actual field data which contains the effect of hydrophilicity deterioration. Therefore an modified modeling equation is proposed and it shows good predictions of the actual fouling characteristics of finned-tube heat exchangers.

Effect of Particulate Matter on the UV-Disinfection of Virus and Risk Assessment (입자성 물질 농도가 바이러스의 UV-처리와 위해성에 미치는 영향 평가)

  • Shin, Yu-Ri;Yoon, Chun-Gyeong;Rhee, Han-Pil;Lee, Seung-Jae
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.6
    • /
    • pp.1028-1033
    • /
    • 2010
  • Wastewater reuse for agricultural irrigation needs treatment and control of pathogens to minimize risks to human health and the environment. In order to evaluate the water quality of UV-treated reclaimed water, this study focused on the relationship between micro-pathogens and particulate matters. MS2 was selected as an index organism because it has similar characteristics to human enteric virus and strong resistance to UV disinfection. The turbidity and suspended solid (SS) were selected for test parameters. In this study, it was performed with different UV doses (30 and $60mJ/cm^2$) for estimation of the MS2 inactivation rate using collimated beam batch experiments in the laboratory. The experiment results by turbidity or SS concentration presented that the increased concentration of them lowered MS2 inactivation. At the turbidity (below 4.27 NTU) and SS (below 1.47 mg/L) of the low level range, the inactivation of 60 UV dose is higher than 30 UV dose. However, at the turbidity and SS of the high level, the increasing UV dose did not show apparent increasing the MS2 inactivation. In quantitative microbial risk assessment (QMRA), it can confirm the trend that $P_D$ and turbidity concentrations have positive correlationship at the low concentration, which was also observed in SS. The QMRA can be helpful in communication with public for safe wastewater reuse and be recommended.

The Study on the Comparison of the ISCST3 Model and Receptor Model by Dispersion Tracing of Particulate Matter from Large Scale Pollution Sources (대단위배출원에서 기인한 입자상오염물질의 확산ㆍ추적을 통한 ISCST3모델과 수용모델의 비교연구)

  • 전상기;이성철;박경선
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.6
    • /
    • pp.789-803
    • /
    • 2003
  • The purpose of this study is to compare the usefulness between Gaussian dispersion model and receptor model with the experimental result of the dispersion tracing of the particulate pollutants from Taean coal-fired power plants. For this purpose, the component analysis of the collected PM 10 samples was performed. In order to trace the pollution sources, factor analysis was done with the result of the component analysis. As a result of the correlativity analysis of the fifteen power plants' profiles offered by US EPA, the correlativity of No.11202 source profile showed highest rate up to 84.5%. Thus it was adopted as proper one and the contribution rate by each pollution source was calculated by Chemical Mass Balance (CMB)-8 model. The contribution rate, which was the effect rate of the power plants on each measuring point, were calculated with a range of 24∼52% and the standard error was below 0.9 $\mu\textrm{g}$/㎥. This indicates the selection of the source profile was appropriate. Also, the concentrations of each point were calculated by the ISCST3 which is suggested by US EPA as one of the regulatory Gaussian dispersion model. The calculation result showed that the predicted concentration was 50∼58 $\mu\textrm{g}$/㎥, comparing with the measured result of 9∼65 $\mu\textrm{g}$/㎥. It was found that the concentration calculated by ISCST3 was underpredicted. It was thought that the receptor model was more favorable than the Gaussian dispersion model in estimating the effect of the particulate matter on a certain receptive point.

A Study on Optimization of Catalyst Injection Controller for Reducing Soot (Soot 저감을 위한 촉매 분사 최적화 방안 연구)

  • Kim Byeong-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.3
    • /
    • pp.278-284
    • /
    • 2006
  • The popularity of the diesel engine revolves around its fuel efficiency, reliability, and durability compared to the gasoline engine. However, the main disadvantage of diesel engine is the emission of particulate matter (PM) which is known as carcinogenic substance. Therefore recent progress in engine management and after-treatment systems has led to great improvement to satisfy strict emission regulations. To comply with powerful environment regulations, this study is focused on the decrease of PM(soot) as to increase significantly exhaust temperature. Therefore, HC injection is used as the method to go to the PM regeneration temperature in front of filters composed of diesel oxidation catalyst(DOC) and diesel particulate filter(DPF). And especially, LPG is used because it has good chemical reactions with exhaust. In this study, we could manufacture the test bench thought LPG injection - with which soot can be decreased-, construct 3 kinds of database(DB) according to quantity of temperature to decide the LPG injection quantity and develop DPF ECU algorithm.

  • PDF

PM Reduction Characteristics of Partial Metal DPF with Screen Mesh Filter Structure (스크린 필터 구조 Partial Metal DPF의 PM 저감 특성)

  • Kim, Chunghui;Kim, Hyunchul;Lee, Geesoo;Choi, Jeonghwang;Chon, Munsoo;Shin, Suk Shin;Suh, Hyun Kyu
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.3
    • /
    • pp.82-87
    • /
    • 2013
  • In this work, the 1L grade integrated metal DOC/DPF filter that can install in engine manifold position was developed to investigate the effect of platinum-coating amount of filter on the improvement of filter activation temperature and reduction of particulate matter (PM). This filter was installed in 2.9L CI engine which meets the EURO-4 emission regulation. Tests for PM reduction efficiency of filter were conducted under ND-13 mode with full-load test condition. It was revealed that the time to reach the activation temperature of metal filter ($280^{\circ}C$) was shorter as the amount of platinum-coating increased. This short activation time can be helpful for the reduction of CO and HC emissions during cold start condition. At the same time, PM reduced as the coating amount increased. The reduction percentage of $DOC_{40}$, $DOC_{20}$, and $DOC_0$ were 96.7% (2.34 mg/kW'h), 95.1% (3.47 mg/kW'h), and 94.5% (3.69 mg/kW'h) compared to previous result (71.4 mg/kW'h), respectively.

The Effect of Outdoor Air and Indoor Human Activity on Mass Concentrations of Size-Selective Particulate in Classrooms (대기오염과 실내 거주자의 활동도가 교실 내부의 입자 크기별 먼지 농도에 미치는 영향)

  • Choi, Sang-Jun
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.2
    • /
    • pp.137-147
    • /
    • 2008
  • This study evaluated the effects of the human activity and outdoor air on concentrations of size-selective particulate matters (PM) by conducting a realtime measurement in classrooms and on roofs at 4 elementary schools, 3 middle schools and 3 high schools in Incheon City. PM concentrations featured repetitive pattern of increasing during break time (including lunch hours) and cleaning time while decreasing during class hours. This trend was more prominent with inhalable PM and PM10 than fine PMs (PM2.5, PM1.0). The indoor/outdoor (I/O) ratio of inhalable PM and PM10 exceeded 1 while that of fine PMs was close to or below 1. The PM2.5 (out)/PM10 (out) ratio stood at 0.59 (${\pm}0.16$) and the PM2.5 (in)/PM10 (in) ratio was 0.29 (${\pm}0.09$), suggesting that occupant activity had a greater effect upon coarse particles (PM10-PM2.5) than upon fine particles (PM2.5, PM1.0). The correlations between the indoor and the outdoor PM concentrations showed a stronger positive correlation for fine particles than that of coarse particles. The linear regression analysis of PM concentrations indoor and outdoor indicated a higher determinant coefficient ($r^2>0.9$), and consistency for fine particles than in case of coarse particles. In conclusion, the results of this study suggest that the indoor coarse particle concentration is more attributed to occupant activity and the indoor fine particle concentration is more influenced by outdoor air pollution.

Concentration Response Functions for Particulate Matter related Health Risk Assessment in South Korea (입자상 대기오염물질의 건강 위해성 평가를 위한 국내 농도반응함수 도출)

  • Ha, Jongsik
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.3
    • /
    • pp.202-213
    • /
    • 2017
  • Objectives: HRA (Health Risk Assessment) is an important tool for measuring the health impacts of air pollution. HRA is already being used widely as an important reference for crafting air pollution policies. However, the absence of a domestic CRF (Concentration Response Function) standard, which is a main component for HRA, could cause confusion amongst policy-makers. The purpose of this study is to tabulate a domestic CRF standard for a PM (Particulate Matter)-related HRA. Methods: This study suggested a domestic CRF standard for HRA thorough a literature review. The literature review for meta-analysis was limited to the English language for epidemiological studies published from January 1980 to March 2016. This meta-analysis was conducted by assuming both fixed- and random-effects of CRF. In addition, studies that reported HRA of air pollution for WHO (World Health Organization), the EC (European Commission), and the EPA (Environmental Protection Agency) were reviewed to compare the CRFs of South Korea to the recommended CRFs of WHO, the EC, or the EPA. Additionally, a domestic CRF standard was supplemented by these. Results: Nineteen studies were selected for the CRF for South Korea. Fifty-three CRFs were derived for meta-analysis. CRFs with a standard for PM-related HRA were divided according to the following four criteria: air pollution, exposure characteristics, type of health impact, and age group. Finally, a domestic CRF standard was created comprised of 21 CRFs. Among these, six CRFs were derived from the results of foreign HRA studies. Conclusions: This study is important in that a domestic CRF standard is first suggested. In addition, this study suggests a further area of study for using HRA as a policy tool and a direction of epidemiological study.

Tensile Mean Strain Effects on the Fatigue Life of SiC-Particulate-Reinforced Al-Si Cast Alloy Composites (SiC입자강화 주조Al-Si복합재의 피로수명에 대한 인장평균변형률의 영향)

  • Go, Seung-Gi
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.23 no.11 s.170
    • /
    • pp.1970-1981
    • /
    • 1999
  • The low-cycle fatigue behaviour of a SiC-particulate-reinforced Al-Si cast alloy with two different volume fractions has been investigated from a series of strain-control led fatigue tests with zero and nonzero tensile mean strains. The composites including the unreinforced matrix alloy, exhibited cyclic hardening behaviour, with more pronounced strain-hardening for the composites with a higher volume fraction of the SiC particles. For the tensile mean strain tests, the initial high tensile mean stress relaxed to zero for the ductile Al-Si alloy, resulting in no influence of the tensile mean strain on the fatigue life of the matrix alloy. However, tensile mean strain for the composite caused tensile mean stresses and reduced fatigue life. The pronounced effects of mean strain on the low-cycle fatigue life of the composite compared to the unreinforced matrix alloy were attributed to the initial large prestrain and non-relaxing high tensile mean stress in the composite with very limited ductility and Cyclic plasticity. Fatigue damage parameter using strain energy, density efficiently accounted for the mean stress effects. Predicted fatigue life using the damage parameter correlated fairly well with the experimental life within a factor of 3. Also, the fatigue damage parameter indicated the inferior life in the low-cycle regime and superior life in the high-cycle regime for the composite, compared to the unreinforced matrix alloy.

HEPA Filter Tests Using PLS and Composite Nanospheres (PLS 및 복합 나노구체를 이용한 HEPA 필터 시험)

  • Hwang, Min-Jin;Sung, Dong Chan;Moon, Hee
    • Applied Chemistry for Engineering
    • /
    • v.24 no.4
    • /
    • pp.357-362
    • /
    • 2013
  • Monodispersed polystyrene latex spheres (PLS) and PS-MPS/silica composite nanospheres were used to test high efficiency particulate air (HEPA) filters. Prior to filter tests, all nanospheres used in this work were characterized by measuring their average particle diameters and coefficients of variation (CV) for assessing them as artificial dusts. The average particle sizes of PLS and composite nanospheres could be well controlled in the range of 100~300 nm well by changing reaction temperature and the amount of a stabilizer during emulsion polymerization. The CV of all nanospheres were also in the range of 3~7%, lower than 15% that is the criterion for monodispersed particle distributions. Furthermore the results of HEPA filter tests show that all nanospheres used were quite proper as artificial dusts for testing air filters.