• Title/Summary/Keyword: 입력강하

Search Result 70, Processing Time 0.032 seconds

Analysis of the Characteristics of the Seismic source and the Wave Propagation Parameters in the region of the Southeastern Korean Peninsula (한반도 남동부 지진의 지각매질 특성 및 지진원 특성 변수 연구)

  • Kim, Jun-Kyoung;Kang, Ik-Bum
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.2 no.1 s.4
    • /
    • pp.135-141
    • /
    • 2002
  • Both non-linear damping values of the deep and shallow crustal materials and seismic source parameters are found from the observed near-field seismic ground motions at the South-eastern Korean Peninsula. The non-linear numerical algorithm applied in this study is Levenberg-Marquadet method. All the 25 sets of horizontal ground motions (east-west and north-south components at each seismic station) from 3 events (micro to macro scale) were used for the analysis of damping values and source parameters. The non-linear damping values of the deep and shallow crustal materials were found to be more similar to those of the region of the Western United States. The seismic source parameters found from this study also showed that the resultant stress drop values are relatively low compared to those of the Western United Sates. Consequently, comparisons of the various seismic parameters from this study and those of the United States Seismo-tectonic data suggest that the seismo-tectonic characteristics of the South eastern Korean Peninsula is more similar to those of the Western U.S.

Analysis of Groundwater Variations using the Relationship Between Groundwater use and Daily Minimum Temperature in a Water Curtain Cultivation Site (수막재배지역에서 일최저기온과 지하수 이용량의 상관관계를 이용한 지하수위 변화 분석)

  • Chang, Sunwoo;Chung, Il-Moon
    • The Journal of Engineering Geology
    • /
    • v.24 no.2
    • /
    • pp.217-225
    • /
    • 2014
  • Water curtain cultivation (WCC) systems in Korea have depleted water resources in shallow aquifers through massive pumping of groundwater. The goal of this study is to simulate the groundwater variations observed from massive groundwater pumping at a site in Cheongweon. MODFLOW was used to simulate three-dimensional regional groundwater flow, and the SWAT (Soil and Water Assessment Tool) watershed hydrologic model was employed to introduce temporal changes in groundwater recharge into the MODFLOW model input. Additionally, the estimation method for groundwater discharge in WCC areas (Moon et al., 2012) was incorporated into a groundwater pumping schedule as a MODFLOW input. We compared simulated data and field measurements to determine the degree to which winter season groundwater drawdown is effectively modeled. A simulation time of 107 days was selected to match the observed groundwater drawdown from November, 2012 to March, 2013. We obtained good agreement between the simulated drawdown and observed groundwater levels. Thus, the estimation method using daily minimum temperatures, may be applicable to other cultivation areas and can serve as a guideline in simulating the regional flow of riverside groundwater aquifers.

A fishway information system of the east coast at Kangwondo (강원도 동해안 지역의 어도 정보시스템 구축)

  • 이창수;최상수;박상덕;박기영
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1997.10a
    • /
    • pp.21-24
    • /
    • 1997
  • 강원도 동해안 지역 하천은 유로연장과 유역면적이 작고 하천 상류부는 급경사이며 하류부는 완경사의 특징을 보여주고 있다. 이 지역 대부분의 하천이 바다로 직접 유입되고 있어 바다와 하천을 옮겨 다니는 회유성 어류가 서식하고 있으며 이들은 소하성, 강하성 및 양측성 어류로 구분된다. 이러한 회유성 어류의 이동은 동해안 지역 하천 하류부 완경사지에서 농업용수를 취수하기 위한 보의 설치로 인하여 어려워졌으며, 이러한 문제에 대처하기 위하여 수산자원 보호령(대통령령 제 5027호) 제 21조에서 어도설치를 규정하고 있다. 강원도 동해안 지역 하천에 설치되어 있는 어도의 실태를 보면 총 19개 하천에 있는 83개소의 농업용 취수보에 약 130개의 어도가 있다. 기존에 설치되어 있는 전어도에 대한 현장조사결과 어도의 기능에 장애를 일으킬 만한 원인은 어도시설의 구조적인 문제와 관리문제로 대별할 수 있다. 본 연구는 어도의 기능이 원활하게 유지되도록 어도시설물에 대한 각종 자료를 체계적으로 집적한 어도정보시스템을 구축하여 어도시설에 대한 현황파악을 용이하게 하고, 지방자치단체에서 개별적으로 수행하던 어도관리를 통합관리할수 있게 하며, 어도시설 표준모형 설계의 기초자료 및 하천 정보, 어류생태정보와 연결된 정보시스템으로의 확장을 가능하게 한다. 본 어도 정보시스템은 기본적으로 인터넷상에서 서비스가 이루어진다. 사용자는 웹 브라우저를 이용하여 어도 정보시스템이 탑재된 웹 서버에 접속하여 서비스를 요청한다. 사용자의 요청을 받은 웹 서버는 게시판과 DBMS를 제어하여 그 결과를 사용자에게 건네준다. 사용된 기술은 ISAPI 규격의 확장인 IDC, HTX이다. 관리자와 사용자의 입력, 수정, 검색, 삭제등에 관한 읽고 쓰기 권한을 구분한다.이 경과함에 따라 소멸하며 약산성에서 높은 생성능을 보임을 알 수 있었다, 강별로는 낙동강에서 THMs파 HANs의 생성능이 비교적 높았고, 영산강에서는 HAAs의 생성능이 높았다. 각 원수의 특성에 따른 생성능을 파악함으로써 생성능 저감방안을 마련하며, 소독 부산물질의 인체노출평가에 따른 위해성평가를 통해 관리기준을 설정해야 할 것이다.는 것으로 나타났다. 본 연구는 한국 문화의 특징이라 할 수 있는 교수-학생간의 인간적인 관계가 중시되는 교육환경하에서, 정보화 사회의 한 수업형태인 재택수업을 외국(특히 미국)의 방법을 그대로 따라 실시할 경우, 많은 부작용이 있을 수 있다는 것을 암시하며, 따라서 우리 교육문화에 맞는 재택수업 형태의 개발이 시급함을 제시한다고 하겠다.column density of HCaN is (1-3):n1014cm-2. Column density at distant position from MD5 is larger than that in the (:entral region. We have deduced that this hot-core has a mass of 10sR1 which i:s about an order of magnitude larger those obtained by previous studies.previous studies.업순서들의 상관관계를 고려하여 보다 개선된 해를 구하기 위한 연구가 요구된다. 또한, 준비작업비용을 발생시키는 작업장의 작업순서결정에 대해서도 연구를 행하여, 보완작업비용과 준비비용을 고려한 GMMAL 작업순서문제를 해결하기 위한 연구가 수행되어야 할 것이다.로 이루어 져야 할 것이다.태를 보다 효율적으로 증진시킬 수 있는 대안이 마련되어져야 한다고 사료된다.$\ulco

  • PDF

A Control Method of Phase Angle Regulator for Parallel-Feeding Operation of AC Traction Power Supply System (교류전기철도 병렬급전 운영을 위한 위상조정장치 제어기법)

  • Lee, Byung Bok;Choi, Kyu Hyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.5
    • /
    • pp.672-678
    • /
    • 2020
  • The parallel-feeding operation of an AC traction power supply system has the advantages of extending the power supply section and increasing the power supply capacity by reducing the voltage drop and peak demand caused by a train operation load. On the other hand, the parallel-feeding operation is restricted because of the circulating power flow induced from the phase difference between substations. Moreover, the power supply capacity is limited because of the unbalanced substation load depending on the trainload distribution, which can be changed by the train operation along the railway track. This paper suggests a Thyristor-controlled Phase Angle Regulator (TCPAR) to reduce the circulating power flow and the unbalanced substation load, which depends on the phase difference and the trainload distribution and provides a feasibility study. A dedicated control model of TCPAR is also provided, which uses substation power supplies as the input to control the circulating power flow and an unbalanced substation load depending on the phase difference and the trainload distribution. Simulation studies using PSCAD/EMTDC shows that the proposed TCPAR control model can reduce the circulating power flow and the unbalanced substation load depending on the phase difference and the trainload distribution. The proposed TCPAR can extend the parallel-feeding operation of an AC traction power system and increase the power supply capacity.

Comparison and Performance analysis of Wavelet OFDM system and FD-OFDM (웨이블릿 OFDM 시스템과 FD-OFDM 시스템 성능 비교 분석)

  • Lee, Junseo;Kim, Ji-Hoon;Kim, Whanwoo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.7
    • /
    • pp.34-42
    • /
    • 2013
  • In this paper, we compare the performance of wavelet OFDM (Orthogonal Frequency Division Multiplexing) and FD-OFDM(Frequency diversity OFDM) system with conventional OFDM system. Wavelet OFDM system uses wavelet transform rather than Fourier transform and contains intermediate characteristics of CDM (Code Division Multiplexing) and OFDM. In wavelet OFDM system, inter-symbol interference (ISI) can be suppressed effectively and adjacent channel interference can be also minimized well. In FD-OFDM system, each parallel branch symbol is multiplied by the orthogonal sequence and distributed into all sub-carriers. Then, each sub-carrier transmits information composed of the symbol components of all parallel branches in the given frame. FD-OFDM contains the frequency diversity characteristic and, therefore, FD-OFDM can be robust to the narrowband interference. For the comparison among different systems, BER (Bit-Error Rate) performances are evaluated in the presence of narrow-band interference and a harmonic noise channel. From the evaluation results, compared to the conventional OFDM, wavelet OFDM and FD-OFDM shows better robustness against the interference and, especially, wavelet OFDM is the most robust in harmonic noise channel.

Analytical and Numerical Model Study to Predict the Temperature Distribution Around an Underground Food Cold Storage Pilot Cavern (냉동저장 공동 주변의 온도분포 예측을 위한 해석해 및 수치모델 적용에 관한 연구)

  • 이대혁;김호영
    • Tunnel and Underground Space
    • /
    • v.12 no.3
    • /
    • pp.142-151
    • /
    • 2002
  • Claesson(2001)'s analytical solution, and two numerical models with Dirichlet and Neuman interior boundary condition respectively were investigated to estimate the transient temperature distribution with distances from the Taejon underground food cold storage pilot cavern. Claesson's solution, which is based on constant temperature boundary condition at the rock wall during a temperature decline step, showed relatively good agreement with temperature measurements in the rock mass in order of average error difference, 0.89$\^{C}$ without any adjustments on laboratory thermal properties to represent the rock mass. For the numerical model with heat flux through the rock wall, a boundary condition setting technique was newly proposed to overcome the difficulty of prescribing variable convective heat tranfer coefficient and far-field air temperature inside the cavern as they may be certainly changed according to the cooling-down time. The results showed also good agreement with measurements in order of average error difference, 1.58$\^{C}$, and were compared to those of the numerical model with fixed temperature at the rock wall. Finally, the most proper procedure to precisely predict the temperature profile around a cavern was proposed as a series of analysis steps including an analytical exact solution and numerical models.

Effect of Change in Hydrological Environment by Climate Change on River Water Quality in Nam River Watershed (기후변화에 따른 남강유역의 수문환경의 변화가 하천수질에 미치는 영향)

  • Kang, Ji Yoon;Kim, Young Do;Kang, Boo Sik
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.8
    • /
    • pp.873-884
    • /
    • 2013
  • In Korea, the rainfall is concentrated in summer under the influence of monsoon climate. Thus, even a small climate change can be significant problems in water resources. As a result, a lot of attention has been focused on climate changes and a number of researches have been conducted in a manner commensurate with the attention to the climate change. This study is intended to forecast the changes in the flow and water quality of the Nam river resulting from the future climate changes in the Nam river basin using a watershed and water quality model. An SWAT model, as a watershed hydrologic model, was established after estimating a climate scenario using an artificial neural network method, and the established model was verified and adjusted using date from the Ministry of Environment to evaluate the applicability of the model. As a consequence, $R^2$ showed more than 0.7 in the simulation test, which satisfies the minimum required level. Results from the SWAT model and the future Namgang dam discharge calculated by HEC-ResSIM is used as input date for QUALKO. The results showed a huge variation in BOD depending on the annual flow of the river, which recorded a maximum difference of 2 mg/L between a rainy season and a dry season. It can be deduced that because rainfall and the runoff of a basin significantly account for the water quality of a river, higher water concentrations are recorded in a dry season in which the flow is not as much as that in a rainy season. It also can be said that water should be reserved in advance to secure water in the Nam river downstream for a dry season and be controlled in an effective and efficient manner to provide better water quality.

Two-Dimension Hydraulic Analysis in the Andong-Imha Linked Reservoir System (안동-임하호 연결 시스템의 2차원 수리해석)

  • Lee, Heung-Soo;Park, Hyung-Seok;Chung, Se-Woong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.205-205
    • /
    • 2012
  • 국내에서 새로운 댐 저수지 건설을 통한 수자원의 안정적인 확보는 어려운 여건에 있다. 따라서 수자원의 효율적인 확보, 댐 하류하천의 수질 개선, 신규댐 건설 대체 효과를 기대하기 위해 기존 댐 저수지의 연계운영이 중요하게 인식되고 있다. 본 연구에서는 다수의 댐 저수지 수체를 연계하여 모델을 통해 해석하고자 안동-임하호를 연결한 2차원 모델(CE-QUAL-W2)을 구축하고, 2002년과 2006년 수문사상을 재현하였으며, 수리해석을 실시하였다. 안동호의 좌안인 임동면 마리와 임하호의 우안인 망천리를 연결하고, EL. 140 m 위치에 길이 2 km, 직경 5.5 m로 콘크리트 터널을 연결하는 것으로 가정하였다. 관내 바닥 마찰계수와 미소 마찰손실 값은 0.05를 입력하였다. 저수지 실측수위와 모의수위를 시계열로 비교한 결과, 2002년과 2006년 안동호와 임하호에서 여름철 유입량 증가에 따른 수위 상승을 잘 반영하였고, 결정계수값($R^2$)이 모두 0.9953 이상으로 나타나 모델은 두 저수지 물수지 계산에 있어서 높은 신뢰도를 보였다. 2006년을 대상으로 안동호와 임하호의 댐 앞에서 수심별 수온의 실측값과 모의값을 비교한 결과, 안동호는 4월부터 성층이 진행되어 5월에 수온약층이 EL. 130 m에 형성되었다. 7월 홍수가 중층 밀도류를 형성하여 수온 성층구조를 교란하였고, 기존의 수온약층이 EL. 120 m 로 하강하였으며, 표층 EL. 145 m에 새로운 수온약층이 형성되는 2단 성층 구조를 보였다. 여름철 동안 이러한 현상은 지속되었고, 10월부터 대기기온 강하와 함께 수직혼합이 시작되었다. 수온예측 오차는 AME $0.336{\sim}1.806^{\circ}C$, RMSE $0.415{\sim}2.271^{\circ}C$의 범위로 실측값을 잘 반영하는 것으로 나타났다. 임하호도 안동호와 유사한 경향을 보였고, 모델은 두 저수지에서 전 기간에 걸쳐 모두 안정적으로 저수지 수온 성층현상을 모의하였다. 2002년 수문사상에서 안동-임하 연계 운영시 안동호의 평균 수위는 1.38 m 상승하였고, 임하호는 3.75 m 낮아지는 것으로 모의되었다. 수위변동에 따른 유동 유량은 임하호에서 안동호로 3억 6천 4백만 톤, 안동호에서 임하호로 2억 9천 1백만 톤으로 임하호에서 안동호로 유동한 유량이 높게 나타났다. 유역면적에 비해 저수용량이 작은 임하호의 경우 두 저수지간 유량의 이동에 따라서 저수용량의 증가로 인한 홍수 저감 효과가 있을 것으로 판단된다. 반면, 안동-임하 연계 운영시 임하호의 차가운 물이 안동호로 유입되는 경우, 안동호의 수온 성층구조에 영향을 주었다. 안동호의 경우는 단독운영시보다 높은 위치에 수온약층(EL. 140 m)이 형성되었으며, 임하호는 반대로 저수위가 낮아지면서 단독운영시보다 수온약층의 위치가 약간 낮아졌다. 이러한 결과는 두 저수지 연결시 안동호의 탁수와 수질 환경에 변화가 있을 수 있음을 시사한다.

  • PDF

A Numerical Study on the Flow and Heat Transfer Characteristics of Aluminum Pyramidal Truss Core Sandwich (알루미늄 피라미드 트러스 심재 샌드위치의 열유동 특성에 관한 수치해석 연구)

  • Kang, Jong-Su;Kim, Sang-Woo;Lim, Jae-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.638-644
    • /
    • 2019
  • In this study, the fluid flow and heat transfer characteristics within sandwich panels are investigated using computational fluid dynamics. Within the sandwich panels having periodic cellular cores, air can freely move inside the core section so that the structure is able to perform multi-functional roles such as simultaneous load bearing and heat dissipation. Thus, there needs to examine the thermal and flow analysis with respect to design variables and various conditions. In this regard, ANSYS Fluent was utilized to explore the flow and heat transfer within the pyramidal truss sandwich structures by varying the truss angle and inlet velocity. Without the entry effect in the first unitcell, the constant rate of pressure and the constant rate of Nusselt number was observed. As a result, it was demonstrated that Nusselt number increases and friction factor decreases as the inlet velocity increases. Moreover, the rate of Nusselt number and friction factor was appreciable in the range of V=1-5m/s due to the transition from laminar to turbulent flow. Regarding the effect of design variable, the variation of truss angle did not significantly influence the characteristics.

A Microcomputer-Based Data Acquisition System (Microcomputer를 이용(利用)한 Data Acquisition System에 관(關)한 연구(硏究))

  • Kim, Ki Dae;Kim, Soung Rai
    • Journal of Biosystems Engineering
    • /
    • v.7 no.2
    • /
    • pp.18-29
    • /
    • 1983
  • A low cost and versatile data acquisition system for the field and laboratory use was developed by using a single board microcomputer. Data acquisition system based on a Z80 microprocessor was built, tested and modified to obtain the present functional system. The microcomputer developed consists of 6 kB ROM, 5 kB RAM, 6-seven segment LED display, 16-Hex. key and 8 command key board. And it interfaces with an 8 channel, 12 bits A/D converter, a microprinter, EPROM programmer for 2716, and RS232C interface to transfer data between the system and HP3000 mini-computer manufactured by Hewlett Packard Co., A software package was also developed, tested, and modified for the system. This package included drivers for the AID converter, LED display, key board, microprinter, EPROM programmer, and RS232c interface. All of these programs were written in 280 assembler language and converted to machine codes using a cross assembler by HP3000 computer to the system during modifying stage by data transferring unit of this system, then the machine language wrote to the EPROM by this EPROM programmer. The results are summarized as follows: 1. Measuring program developed was able to control the measuring intervals, No. of channels used, and No. of data, where the maximum measuring speed was 58.8 microsec. 2. Calibration of the system was performed with triangle wave generated by a function generator. The results of calibration agreed well to the test results. 3. The measured data was able to be written into EPROM, then the EPROM data was compared with original data. It took only 75 sec. for the developed program to write the data of 2 kB the EPROM. 4. For the slow speed measurements, microprinter instead of EPROM programmer proved to be useful. It took about 15 min. for microprinter to write the data of 2 kB. 5. Modified data transferring unit was very effective in communicating between the system and HP3000 computer. The required time for data transferring was only 1~2 min. 6. By using DC/DC converting devices such as 78-series, 79-series. and TL497 IC, this system was modified to convert the only one input power sources to the various powers. The available power sources of the system was DC 7~25 V and 1.8 A.

  • PDF