• Title/Summary/Keyword: 입구 길이

Search Result 181, Processing Time 0.019 seconds

A study on velocity profiles and inlet length of developing transitional pulsating flows in the entrance region of a square duct (정4각 덕트 입구영역에서 천이파동유동의 속도분포와 입구길이에 관한 연구)

  • 유영태;모양유;홍성삼
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.15 no.2
    • /
    • pp.92-104
    • /
    • 1993
  • In the present study, the velocity profiles and entrance length of developing transitional pulsating flows are investigated both analytically and experimentally in the entrance region of a square duct. The systems of conservation equations for transitional pulsating flows in a square duct are solved analytically by linearizing the non-linear convective terms. Analytical solutions are obtained in the form of infinite series for velocity pofiles. The experimental study for the air flow in a square duct(40mm*40mm*4000mm) is carried out to measure velocity profiles and other parameters by using a hot-wire anemometer with a data acquisition and processing system. The distribution of velocity profiles( $u_{ps}$ / $u_{m,ta}$) in the decelerating period is higher than in the accelerating period. The distribution of the axial component of the axial component of velocity in the transitional flow is nearly uniform in the central region of the duct, and decrease rapidly near the wall. The entrance length correlation of the transitional pulsating flows in a square duct is obtained to be $L_{e}$/ $D_{h}$=0.83 $A_{1}$R $e_{ta}$ /(.omega. sup+1)$^{2}$TEX>

  • PDF

The heat transfer characteristics of viscoelastic non-newtonian fluids in the entrance region of circular tube flows (원형관속을 유동하는 점탄성 유체의 입구 영역 열전달 특성에 관한 연구)

  • 엄정섭;황태성;유상신
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.5
    • /
    • pp.1032-1043
    • /
    • 1989
  • The heat transfer characteristics of the drag reducing polymer solutions are investigated experimentally in the thermal entrance region of circular tube flows. Fluids used in experiments are the aqueous solutions of high molecular polymer, polyacrylamide Separan AP-273 and the range of polymer concentrations is from 20 to 1000 wppm. Two stainless steel tubes with inside diameter 8.5mm(L/D=712) and 10.3mm(L/D=1160) are used for the heat transfer flow loops. The flow loop is set up to measure friction factors and heat transfer coefficients of test sections in two different modes; the recirculating flow system and once-through flow system. The test tubes are heated directly by electricity to apply the constant heat flux boundary conditions to the wall. Three different types of adaptors are used to observe the effects of the upstream flow conditions of the heat transfer test sections. The viscosity and characteristic relaxation time of the test fluids circulating in the flow system are measured by the capillary tube viscometer and falling ball viscometer at regular time intervals. The installed adaptors exhibit slight effect on the entrance heat transfer of Newtonian fluid. However, no noticeable effects are observed for the entrance heat transfer of the drag reducing fluids. The order of magnitude of the thermal entrance lengths of the drag reducing fluids which follow the minimum friction asymptote is much longer than that of Newtonian fluids in turbulent flows. A new dimensionless parameter, the viscoelastic Graetz number, is defined and all the experimental data are recasted in terms of the viscoelastic Graetz number. The local Nusselt number of the viscoelastic fluids is represented as a function of flow behavior index n and the viscoelastic Graetz number. As degradation continues the viscosity and the characteristic relaxation time of the testing fluids decrease. Weissenberg number defined by the relaxation time and D/V appears to be a proper dimensionless parameter in describing degradation effects on heat transfer of the viscoelastic fluids.

A Numerical Study on Performance Characteristics of a Subscale Diffuser for High-Altitude Simulation (고고도 모사를 위한 축소형 디퓨저의 성능 특성에 대한 수치적 연구)

  • Jeong, Bong-Goo;Yim, Kyung-Jin;Jo, Seong-Hwi;Kim, Hong-Jip;Jeon, Jun-Soo;Ko, Young-Sung;Kim, Seung-Han;Han, Yeoung-Min
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.570-573
    • /
    • 2012
  • Performance characteristics of subscale diffuser for high-altitude simulation have been numerically investigated. The length of diffuser entrance with respect to nozzle exit diameter was changed to 0, 50, 100%, respectively. In addition, flow characteristics have been studied for various length to diameter ratio of secondary throat diffuser. As a result, the shape of plume was contracted for insufficient length of diffuser entrance. Also, if the length to diameter ratio of secondary throat diffuser were less than 7 or 8, mach disk has been formed inside the diffuser.

  • PDF

Analysis of temperature distribution per length in highway tunnel (공용중인 고속도로 터널내 연장별 온도 조사 분석)

  • Hong, Seung-Ho;Lee, Kyung-Ha;Kim, Nag-Young;Yun, Kyong-Ku
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.7 no.3
    • /
    • pp.259-267
    • /
    • 2005
  • This paper analyzed characteristic of temperature change as well as bottom of tunnel with thermometer according to tunnel length and region during one year. And it measured temperature distribution near tunnel portal. In the paper it was known that tunnel entrance and exit have different characteristic temperature distribution in accordiance with bottom of tunnel per tunnel length. Temperature of tunnel changed from tunnel exit to fifty meter and distribution of tunnel temperature was established uniform regardless of tunnel length. But temperature distribution of tunnel changed in tunnel entrance differ from tunnel exit in the location of one hundred twenty five meter and one hundred fifty meter. Cold air inflowed from tunnel entrance have influenced with the location of one hundred twenty five meter and one hundred fifty meter.

  • PDF

Effects of Prandtl Numbers on Heat Transfer of Backward-Facing Step Laminar Flow with a Pulsating Inlet (입구유동 가진이 있는 층류 후향계단 유동에서 열전달에 대한 프란틀수 효과해석)

  • Kim, Won-Hyun;Park, Tae-Seon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.9
    • /
    • pp.923-930
    • /
    • 2012
  • The wall heat transfer of backward-facing step laminar flows with different Prandtl numbers and a pulsating inlet is investigated by unsteady simulations. The inlet is perturbed by the variation of frequency and amplitude. Temperature-dependent transport properties are adopted. Various characteristics of the wall heat transfer are explained by the variation of the thermal boundary layer. For Pr < 1, the wall heat transfer of temperature-dependent properties is decreased compared to that of constant properties, whereas it increases for Pr < 1. In addition, the wall heat transfer increases depending on the pulsating amplitude. However, the results of frequency variation for St < 0.2 show that the heat transfer is strongly enhanced at a specific frequency. In particular, the increase in the wall heat transfer is strongly related to the root mean square of the fluctuations of the reattachment length.

VOICE REHABILITATION FOLLOWING LARYNGECTOMY -MYOMUCOSAL TRACHEOESOPHAGEAL SHUNT- (후두전적출술후 Myomucosal tracheoesophageal shunt를 이용한 음성 재활에 관한 연구)

  • 엄재욱;이건주;박춘근
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1991.06a
    • /
    • pp.27-27
    • /
    • 1991
  • 저자들은 후두전적출술을 시행한 환자의 음성재활을 위해 식도의 근육과 점막을 이용한 shunt를 만들고 이상적인 shunt의 기능을 위해 shunt의 길이, 직경, 적절한 괄약효과 보강, 음성훈련 요령등에 대해 개 5마리를 이용한 동물실험 및 5례의 임상 적용을 통해 다음과 같은 지식을 얻었기에 문헌 고찰과 아울러 보고하는 바이다. 1. shunt의 협착에 대한 문제는 없었다. 2. 식도측의 입구를 좁혀 줌으로서 기관으로의 흡인을 방지할 수 있었다. 3. Nelaton catheter는 72시간 삽입이 적당했다. 4. 음성훈련은 3주부터 시작함이 적당했다. 5. shunt의 길이는 3 cm가 적당했다.

  • PDF

CFD Analysis of Submersible Slurry Pump with Two Blades (2엽 수중 슬러리 펌프 임펠러 전산해석)

  • Yun, Jeong-Eui
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.3
    • /
    • pp.263-268
    • /
    • 2011
  • We aimed to develop a non-clogging submersible slurry pump with two blades to replace the conventional vortex pump. To do this, we simulated the effect of parameters such as the blade angle $\beta$ and the blade-length angle $\alpha$ on pump efficiency. We used the commercial codes ANSYS CFX and BladeGen. The results showed that the best blade shape was obtained for $\beta$ = $30^{\circ}$ and that the pump efficiency was proportional to $\alpha$ in the simulated range.

정4각 덕트 입구영역에서 층류정상 유동특성에 관한 연구

  • 박길문;고영하
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.4
    • /
    • pp.927-936
    • /
    • 1990
  • 본 연구에서는 정4각 단면덕트의 입구영역에서 층류 정상유동의 유동특성을 이론적 및 실험적인 방법으로 속도파형과 속도분포를 얻어서 유동이 발달되고 있는 유 동특성과 입구길이를 규정하였다. 이론적인 방법으로는 덕트입구영역에서 공기유동 에 대한 운동량방정식을 유도한 후, 운동량방정식 중의 비선형인 대류항을 선형화시켜 서 Laplace변환으로 속도 분포식의 해를 구하였고, 실험적인 방법으로는 시험덕트의 크기가 40*40*4,000nm(가로*세로*높이)인 정 4각단면덕트에 송풍기로 공기를 흡입 하여 정상유동을 얻었고, 열선유속계에 의하여 속도파형과 속도분포 등의 측정한 결과 를 이론식과 비교검토하였다.

Resonant Characteristics in Rectangular Harbor with Narrow Entrance (2.Effects of Entrance Energy Loss) (개구부가 좁은 직사각형 항만의 공진 특성 (2.항입구 에너지 손실의 영향))

  • 정원무;박우선;서경덕;채장원
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.11 no.4
    • /
    • pp.216-230
    • /
    • 1999
  • A Galerkin finite element model for the analysis of harbor oscillation has been developed based on the extended mild-slope equation. Infinite elements are used to accomodate the radiation condition at infinity and joint elements to treat the matching conditions at the harbor entrance which include the energy loss due to flow separation. The numerical tests for rectangular harbors with fully or partially open entrances show that the energy loss at the harbor entrance considerably reduces the the amplification ratios at the innermost parts of the harbors and that the amplification ratios decrease considerably with increasing incident wave heights and jet lengths at the harbor entrance. Application of the model to the Gamcheon harbor show that when the incident wave amplitude is small the amplification ratios rather increase when the entrance energy loss is included than when ignored because of the shift of the resonance periods. Even though the entrance energy loss was insignificant for the measured long-period incident waves, it would be of great importance if the incident waves were large as in the attack of tsunamis. The resonance period of the Helmholtz mode at the Gamcheon Harbor was calculated to be 31 minutes, which agrees well with the measured one between 27 and 33.3 minutes. The measured resonance periods between 9.4 and 12.1 minutes and 5.2 and 6.2 minutes were also calculated by the numerical model as 10.4 minutes and 6.6 or 5.6 minutes, indicating good performance of the model. On the other hand, it was shown that a variety of oscillation modes exists in the Gamcheon Harbor and lateral resonances of considerable amplification ratios also exist at the periods of 3.6 and 1.6 minutes as in the Young-II Bay.

  • PDF

Flow Analysis of Magnetic Fluid in Inlet Length Region between Parallel Plates (평행평판사이의 입구길이영역에서 자성유체의 유동해석)

  • Park, Jung-Woo;Park, Gi-Tae;Kim, You-Jun;Seo, Lee-Soo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.2
    • /
    • pp.7-12
    • /
    • 2008
  • It is attempted, in this study, to analyze the movement of the fluidity of polar magnetic fluid and to relate Newtonian fluid with the Inlet Length of infinity plates when distance between parallel plates is L. A numerical analysis is performed for the variation of inlet length when magnetic effect parameter and polar effect parameter which give special advantages to magnetic fluid are increased. From the result of numerical analysis, we confirmed that the inlet length shortens as the flux around the center axis is accelerated and the flux around the surface of a wall is controlled as the magnetic effect parameter and the polar effect parameter are increased.