• Title/Summary/Keyword: 입구 각도

Search Result 273, Processing Time 0.025 seconds

Performance Analysis for Turbo Blower According to Inlet-Vane Angles (입구베인 각도에 따른 터보블로어 성능특성 연구)

  • Jang, Choon-Man;Lim, Soo-Jung;Yang, Sang-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.3
    • /
    • pp.301-307
    • /
    • 2011
  • Turbo blowers are mainly used in refuse collection systems. We discuss blower performance in relation to the angle of the inlet vane installed at the upstream of the blower. The flow characteristics of the components are analyzed by three-dimensional Navier-Stokes analysis and compared to experimental results. A two-stage serially connected turbo blower is introduced to analyze the performance experimentally. Throughout the experimental measurements and the numerical simulation, the distorted inlet velocity generated in the small vane angle reduces the performance of the blower, because of the local leading-edge separation and the resulting non-uniform blade loading. We also perform a detailed flow analysis using the results obtained in the numerical simulation.

정4각 덕트 입구영역에서 층류정상 유동특성에 관한 연구

  • 박길문;고영하
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.4
    • /
    • pp.927-936
    • /
    • 1990
  • 본 연구에서는 정4각 단면덕트의 입구영역에서 층류 정상유동의 유동특성을 이론적 및 실험적인 방법으로 속도파형과 속도분포를 얻어서 유동이 발달되고 있는 유 동특성과 입구길이를 규정하였다. 이론적인 방법으로는 덕트입구영역에서 공기유동 에 대한 운동량방정식을 유도한 후, 운동량방정식 중의 비선형인 대류항을 선형화시켜 서 Laplace변환으로 속도 분포식의 해를 구하였고, 실험적인 방법으로는 시험덕트의 크기가 40*40*4,000nm(가로*세로*높이)인 정 4각단면덕트에 송풍기로 공기를 흡입 하여 정상유동을 얻었고, 열선유속계에 의하여 속도파형과 속도분포 등의 측정한 결과 를 이론식과 비교검토하였다.

RSVP Flow Aggregation for end-to-end QoS on MPLS Network (MPLS망에서 종단간의 서비스 질을 보장하기 위한 RSVP 흐름 군집)

  • 김경일;김상하
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1998.10a
    • /
    • pp.383-385
    • /
    • 1998
  • MPLS망은 레이블 스위칭을 통해 고속의 라우팅은 제공하지만 서비스 질은 보장하지 않는다. 따라서 MPLS망을 통해 종단간 서비스 질을 보장하기 위한 방법으로 RSVP 흐름 군집을 이용한다. 즉, 입구 라우터와 출구 라우터 간의 흐름들이 요구하는 자원들의 군집하여 예약함으로써 각 흐름들을 요구하는 서비스 질을 보장하게 된다. 이와같이 각 흐름들이 요구하는 자원들을 군집하여 예약하는 이유는 각 흐름별로 예약하고 그 예약에 따라 처리를 하게 되었을 때 흐름 별 상태 정보 저장 및 처리하는 데 많은 비용이 들기 때문이다. 특히 이러한 흐름의 수가 매우 많은 코어 망에서 문제가 크다. 이처럼, 입구 라우터와 출구 라우터간의 흐름들이 요구하는 자원들을 군집하여 예약했을 때, 군집된 흐름들이 입구 라우터와 출구 라우터까지 레이블 스위칭을 통해 전달되면서 이렇게 예약된 자원을 이용하여 서비스 질을 보장 받을 수 있어야 한다. 본 논문에서는 군집된 RSVP 메시지를 통해 자원 예약이 이루어질 때 레이블을 할당하고 바인딩 시킴으로써(레이블이 자원 예약 상태 정보에 대한 구분자 역할을 함) 레이블 스위칭을 통해 패킷이 전달되면서 예약된 자원의 서비스를 받을 수 있게 된다. 자원예약 상태 정보를 레이블 운송 테이블에 저장함으로써 레이블 교환 시 자연적으로 자원 예약에 대한 구분이 됨으로 빠른 구분이 가능하다.

  • PDF

ICP 식각 장치에서 GDP 구조 및 유량비율에 의한 플라즈마 균일도 최적화에 대한 수치해석

  • Yang, Won-Gyun;Jeon, Gyeong-Hui;Ju, Jeong-Hun;Nam, Chang-Gil
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.280-280
    • /
    • 2011
  • 유도결합 플라즈마를 이용한 식각 장치에서 플라즈마 균일도 향상에 대한 수많은 연구가 이뤄지고 있다. 안테나의 디자인, 인가 전력과 주파수, 안테나와 기판간의 거리, 기판과 챔버 외벽간의 거리 등 다양한 변수들이 변화되어 왔다. 또한, 최근에는 식각 균일도뿐만 아니라 식각 속도 향상에도 많은 관심이 모아지면서 유동에 영향을 주는 GDP 구조가 다시 중요해지고 있다. 본 연구에서는 300 mm 식각장치를 형상화하고, GDP의 구조와 유량비에 따라 플라즈마의 균일도에 어떻게 영향을 끼지는지 사용 유체역학 전산모사 프로그램인 CFD-ACE+를 이용하여 예측해 보았다. 안테나는 2중 직렬방식으로 안쪽과 바깥쪽의 안테나에 각기 다른 전력을 인가 할 수 있는 구조를 사용했으며, 압력은 10에서 60 mTorr까지 변화시켰다. GDP의 구조는 안쪽 입구와 바깥쪽 입구가 있으며 역시 따로 유량을 조절할 수 있도록 설계하였다. 안쪽 입구는 수직방향을 향하고 있으며, 바깥쪽 입구는 90도 이내의 각을 갖도록 꺾여 있는 것과 수평방향으로 주입할 수 있는 구조, 두 가지를 사용하였다. 유량 비율은 안쪽 입구와 바깥쪽 입구를 2:8, 5:5, 8:2로 고정하였다. 우선 GDP의 구조가 90이내의 각을 갖도록 주입되는 구조에서는 어떤 유량비율에서도 약간의 vortex가 발생했다. 수직방향의 유량이 감소될수록 기판에서 멀리서 발생했으며 강도 또한 감소했다. 기판 표면에서의 압력분포 균일도도 8:2에서 2.8%, 2:8에서 0.6%로 향상되었다. 2:8의 유량 비율에서 압력을 10에서 60 mTorr까지 향상시키면 vortex 효과는 감소되나 기판에서의 압력 균일도가 0.8%까지 약간 나빠졌다. 여기서 발생되는 vortex는 GDP 구조를 수평방향으로 주입되기 함으로서 해결할 수 있었으며, 압력 균일도도 0.2%까지 향상시킬 수 있었다. 또한, 강한 수직방향의 유량은 중심에 발생하는 플라즈마의 중앙을 밀어내는 효과를 확인했으며, 실험적 증명이 추후 연구단계로 진행될 예정이다. 식각 균일도나 식각 속도를 예측하려면 CF계열의 복잡한 가스를 사용해야하기 때문에 유량이 플라즈마에 미치는 영향을 보기 위해서 본 연구에서는 단일종인 Ar 가스만을 사용하였다. 첫 단계로 이와 같이 최적화시킨 유동조건에서 복잡한 식각가스를 이용한 플라즈마 계산은 다음 단계로 준비 중에 있다.

  • PDF

Effects of Chamfered Perforated Plate on Pressure Loss Characteristics (챔퍼가 적용된 타공판의 압력 강하 특성에 대한 연구)

  • You, Kyeongsik;Lee, Hyungyu;Cho, Jinsoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.11
    • /
    • pp.779-786
    • /
    • 2019
  • Effects of chamfered perforated plate on pressure loss characteristics were studied with CFD analysis. Both inlet chamfer angle and outlet chamfer angle were considered. Perforated patterns were compared by pressure loss coefficient in certain porosity and Reynolds number. Reynolds number effects were studied for several chamfer angles and plate thickness. As the inlet chamfer angle was increased, the pressure loss coefficient was decreased until the certain angle and reversed to increase. In the outlet chamfered shape cases, the pressure loss coefficient was increased with chamfer angle. Effects of pattern shapes and Reynolds number on pressure loss characteristics were negligible with different chamfer angles and thickness studied in this paper.

An Experimental And Theoretical Study on the Corrugated Water-Trickle Collector (파형단면을 가진 유하식 집열기의 이론 및 실험 연구)

  • Lee, Jong-Ho;Chung, Mo;Park, Won-Hoon
    • Solar Energy
    • /
    • v.7 no.1
    • /
    • pp.42-52
    • /
    • 1987
  • 파형 단면을 가진 유하식 집열기의 이론 및 실험 결과로서 유량, 각도등 집열성능에 미치는 영향등이 고려되었다. 입구 온도와 출구온도 차이가 적을 경우에는 이론과 실험치가 잘 맞으나 온도차이가 많을 경우 혹은 입구온도가 높을 때에는 투과체안에 생기는 결로 및 수증기의 영향으로 편차가 커진다. 개방회로와 폐쇄회로의 경우를 구분하여 실험되었는데 개방회로의 경우 효율은 약간 저하되지만 전반적인 성능은 폐쇄회로와 같은 경향을 나타내었다. 개방회로는 과열을 막는 방편으로 이용될 수 있다.

  • PDF

가스터어빈 트랜지션 덕트 내에서 스월각이 손실계수에 미치는 영향에 대한 연구

  • 임찬선;전승배;김승우
    • 유체기계공업학회:학술대회논문집
    • /
    • 1998.02a
    • /
    • pp.150-156
    • /
    • 1998
  • 가스터어빈 트랜지션 덕트 내에서의 공기 역학적인 거동을 입구 스월각의 변화에 대하여 고찰하였다. 트렌지션 덕트가 작은 확산각(divergence angle)을 가지더라도 스트럿 영향으로 인한 탈설계점에서의 유동 패턴은 트랜지션 덕트 내에서의 유동특성을 더욱 악화시킨다. 시험범위의 스월각은 마하수 변화에 따라 손실계수에 큰 영향을 주지 못하였으며 트랜지션 덕트 내에서의 손실 정조는 만족할만 하나, 시험결과에 따르면 저압터빈의 노즐손실은 큰 입사각의 영향으로 커질것으로 생각되며, 또한 스트럿으로부터 떨어져 나오는 와류는 저압터빈의 로우터 블레이드의 진동에 악영향을 미칠 것으로 생각된다.

  • PDF

An Implantable Micro Check-Valve with A Pre-Stressed Membrane (초기 음력이 내재된 박막을 갖는 인체삽입용 마이크로 체크 밸브)

  • Lee, S.W.;Kim, M.S.;Yoon, H.J.;Yang, S.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.56-58
    • /
    • 2001
  • 본 논문은 수두증 환자의 체내에 삽입하는 파릴린 막체크 밸브의 제작과 시험에 관한 것이다. 파릴린 막 체크밸브는 세 가지 특징을 가지고 있다. 박막의 초기 인장응력에 따라 특정한 압력 이상에서 밸브가 열리고, 막과 밸브 입구의 크기에 따라 순방향과 역방향 특성을 서로 다르게 하며, 앤티사이폰 역할을 한다. 파릴린 체크 밸브는 상부 기판과 하부 기판으로 구성되어 있다. 하부 기판은 입구, 출구, 유로, 두 개의 완충챔버로 이루어져 있고, 상부 기판은 입구 박막과 두 개의 완충 챔버 박막으로 이루어져 있다. 하부 기판에는 밸브 구멍 주위에 밸브 시트를 두어 두 기판을 조립할 때 밸브 시트가 막을 변형시키면서 박막에 초기 인장 응력을 주도록 되어 있다. 또, 하부 기판에 특정한 각을 가진 유로 및 완충 챔버를 형성하여 역류 발생시 유체를 완충 챔버 쪽으로 흐르게 한다. 유한요소법(FEM)을 이용하여 박막과 밸브 입구의 크기, 박막의 두께 등을 변화시켜가며 박막의 응력과 변형을 해석하였고 해석 결과로부터 밸브 시트의 높이를 결정하였다. 마이크로머시닝으로 두 기판을 제작하고 조립한 후, 순방향과 역방향의 압력에 대한 유량을 측정하여 파릴린 체크 밸브의 특성을 시험하였다.

  • PDF

A study on velocity profiles and inlet length of developing transitional pulsating flows in the entrance region of a square duct (정4각 덕트 입구영역에서 천이파동유동의 속도분포와 입구길이에 관한 연구)

  • 유영태;모양유;홍성삼
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.15 no.2
    • /
    • pp.92-104
    • /
    • 1993
  • In the present study, the velocity profiles and entrance length of developing transitional pulsating flows are investigated both analytically and experimentally in the entrance region of a square duct. The systems of conservation equations for transitional pulsating flows in a square duct are solved analytically by linearizing the non-linear convective terms. Analytical solutions are obtained in the form of infinite series for velocity pofiles. The experimental study for the air flow in a square duct(40mm*40mm*4000mm) is carried out to measure velocity profiles and other parameters by using a hot-wire anemometer with a data acquisition and processing system. The distribution of velocity profiles( $u_{ps}$ / $u_{m,ta}$) in the decelerating period is higher than in the accelerating period. The distribution of the axial component of the axial component of velocity in the transitional flow is nearly uniform in the central region of the duct, and decrease rapidly near the wall. The entrance length correlation of the transitional pulsating flows in a square duct is obtained to be $L_{e}$/ $D_{h}$=0.83 $A_{1}$R $e_{ta}$ /(.omega. sup+1)$^{2}$TEX>

  • PDF