• Title/Summary/Keyword: 입구베인

Search Result 24, Processing Time 0.029 seconds

Performance Analysis for Turbo Blower According to Inlet-Vane Angles (입구베인 각도에 따른 터보블로어 성능특성 연구)

  • Jang, Choon-Man;Lim, Soo-Jung;Yang, Sang-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.3
    • /
    • pp.301-307
    • /
    • 2011
  • Turbo blowers are mainly used in refuse collection systems. We discuss blower performance in relation to the angle of the inlet vane installed at the upstream of the blower. The flow characteristics of the components are analyzed by three-dimensional Navier-Stokes analysis and compared to experimental results. A two-stage serially connected turbo blower is introduced to analyze the performance experimentally. Throughout the experimental measurements and the numerical simulation, the distorted inlet velocity generated in the small vane angle reduces the performance of the blower, because of the local leading-edge separation and the resulting non-uniform blade loading. We also perform a detailed flow analysis using the results obtained in the numerical simulation.

Numerical Analysis of Flows for Agricultural Dryer with Heat Pump (히트펌프를 이용한 농산물 건조기 유동 수치해석)

  • Park, Sang-Jun;Lee, Young-Lim
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05b
    • /
    • pp.676-678
    • /
    • 2011
  • 히트펌프 사이클을 이용한 건조 공정은 최종 제품의 생산을 위하여 많은 산업 분야에 요구되는 필수 공정으로 본 논문에서는 대형 히트펌프 건조기의 상부 분리대의 가이드 베인의 형상 및 수량을 최적화 하였다. 이를 위해 팬은 성능곡선 모델을 사용하였고, 증발기와 응축기는 다공성 매질로 가정하였다. 이는 팬을 통과하여 가이드 베인을 따라 건조기 입구로 들어가는 바람의 균일도를 예측할 수 있어 설계 정확도 향상에 기여할 수 있다.

  • PDF

The performance of combined heat and power plant according to gas turbine air mass flow rate change (가스터빈 공기량 조절에 따른 열병합발전 성능 변화)

  • Kim, Jae-Hoon;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.18 no.2
    • /
    • pp.32-40
    • /
    • 2022
  • In this study, we investigated the operation data of combined heat and power in accordance with the change of the inlet guide vane with partial load. The partial load 80% could close the inlet guide vane up to 24%, and the exhaust gas temperature could be increased by 52℃. The partial load 90% could close the inlet guide vane up to 12%, and the exhaust gas temperature could be increased by 23℃. At 80% of partial load with the thermal load tracking mode, the output could be increased up to 5.68 MW, the combined cycle efficiency increased by 0.73%, and the combined heat and power efficiency increased by 1.81%. At 90% of the partial load, the output could be increased up to 2.55 MW, the combined cycle efficiency increased by 0.32%, and the combined heat and power efficiency increased by 0.72%.

  • PDF

Numerical Study of the Flow Characteristics in a Diesel Exhaust System with a Vane-Type Static Mixer (베인 타입 스태틱 믹서의 기하학적 변수에 따른 디젤 배기관 내 유동특성에 관한 연구)

  • Kang, Kyoung-Nam;Lee, Jee-Keun;Kim, Man-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.4
    • /
    • pp.397-404
    • /
    • 2012
  • In this research, a numerical study was carried out on the mixing and flow characteristics of a vane-type static mixer for the reduction of $NO_x$ in the SCR systems from the diesel exhaust environments. The mixer was located at a distance of 57 times the pipe diameter away from the inlet. The analyses were performed by changing various parameters such as vane angles, blockage ratio, and location of the vane. Flow characteristics through the mixer were characterized by the uniformity index, swirl number, and pressure drop. The results show that uniformity index, pressure coefficient and swirl number are substantially influenced by the vane angle, blockage ratio and position of the vane of the mixer. In particular, the swirl number was increased when the vane was located near the pipe wall, or the vane angle was increased or scale was extended.

Numerical Study for the Optimal Operation of Semi Dry Reactor(SDR) (SDR 반응의 운전 최적화를 위한 전산 해석)

  • Park, Ki-Woo;Jung, Yu-Jin;Jeong, Moon-Heon;Hong, Sung-Gil;Jung, Jong-Hyeon;Lim, Ki-Hyuk;Shon, Byung-Hyun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05a
    • /
    • pp.426-430
    • /
    • 2012
  • 본 연구에서는 3차원 수치 해석 기법으로 SDR 반응기 내 유동 특성을 모사하여 유동 분포 및 체류 시간등을 확인하고 혼합 특성 개선을 위한 방법에 대해 연구하였다. 본 연구 대상 SDR 반응기는 입구 덕트와 반응기 본체의 접속 구간에 가이드 베인(Guide vane)이 설치되어 있고 그 바로 하부 지점에 흡수제를 분무하는 노즐이 설치되어 있다. 이는 처리가스가 반응기로 유입될 때 가이드 베인에 의해 선회류를 형성하여 분무된 흡수제와의 혼합을 촉진시키기 위한 목적으로 설치하였다. 시간당 1,971$m^3/min$ at $260^{\circ}C$의 처리가스가 반응기 상부로 유입되어 가이드 베인을 거쳐 선회류를 형성한 후흡수제와 혼합되어 하부로 배출되는 구조이다. 유동 특성을 분석한 결과, 처리가스가 반응기 중앙으로 강하게 편중되고 있었으며 반응기 양 측면으로 부상 기류가 형성되고 있음을 확인할 수 있다. 또한 강한 편류에 의해 체류시간도 매우 짧은 것으로 판단되는 바, 가이드 베인의 기류 안내 각도가 적합하지 못함을 확인할 수 있었다. 이는 곧 혼합 특성 저하에 따른 미반응 액적의 다량 발생과 함께 고착에 의한 스케일 형성 가능성이 매우 클 것으로 예상되므로 혼합 특성을 개선할 수 있는 설계 변경이 필요할 것으로 판단되었다. 따라서 편류를 해소하고 노즐 근처에서의 체공시간을 확보할 수 있도록 가이드 베인의 안내 각도를 더 크게 변경한 결과, 기존 설계상에서 본체 중앙에 형성되는 편류가 해소되고 선회류의 전개 각도가 커지면서 체류시간 역시 약 5초 이상으로 유지되고 있음을 확인할 수 있었다. 따라서 가이드 베인의 각도만 변경하더라도 본체 형상의 추가적인 변경없이 유동의 혼합 특성을 개선시킬 수 있을 것으로 판단되었다.

  • PDF

A study on the vaneless diffuser and volute casing design for the improvement of small centrifugal compressors (소형 원심 압축기의 성능 향상을 위한 베인 없는 디퓨저와 볼류트 케이싱의 설계에 관한 연구)

  • Jo, Jae Phil;Paek, Seung Yun;Kim, Sung Don;Ahn, Kyubok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.3722-3730
    • /
    • 2015
  • The performance improvement of a small centrifugal compressor for waste water treatment has been conducted by the design change of vaneless diffuser and volute casing. Existing two compressors use a common impeller, but the width and length of the vaneless diffuser and the cross-sectional shape of the volute casing are different, respectively. Based on the experiment of the existing two compressors and their CFD results, the design of the vaneless diffuser and the volute casing has been changed. It was found that the strength of the interaction among the volute tongues, the vaneless diffusers and the impellers of two existing/one improved compressors, was affected by the cross-sectional area and inlet radial length of the volute casing including system losses' change. The efficiency of the impeller with one existing design was increased as the decrease of the width of the vaneless diffuser, but losses at the diffuser were accumulated. In conclusion, approximately 2.88%p efficiency increase at the design point of the new compressor with the improved design has been confirmed by CFD analysis results.

Performance Analysis by CFD and Aerodynamic Design of 100kW Class Radial Turbine Using Waste Heat from Ship (선박 폐열을 이용한 100kW급 구심터빈 공력설계 및 CFD에 의한 성능해석)

  • Mo, Jang-Oh;Kim, You-Taek;Kim, Mann-Eung;Oh, Cheol;Kim, Jeong-Hwan;Lee, Young-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.175-181
    • /
    • 2011
  • The purpose of this study is to secure the design data for the optimization of the radial turbine and heat cycle system, by using the CFD analysis technique and the design of 100kW class radial turbine applicable to waste heat recovery generation system for ship. Radial turbine was comprised of scroll casing, vane nozzle with 18 blades and rotor with 13 blades, and analysis grid was used to about 2.3 million. Mass flow rate and rotational speed was 0.5kg/s, 75,0000rpm, respectively. Eight kinds of inlet pressure was set between 195 and 620kPa. As the flow accelerated through the nozzle passage to the throat, the pressure level at the pressure and suction sides becomed similar to about Mach number of 0.35. When the inlet temperature and pressure was $250^{\circ}C$, 352kPa respectively, the isentropic efficiency and mechanical power showed the analysis results of 74% and 108kW.

NUMERICAL OPTIMIZATION OF TEMPERATURE DISTRIBUTION IN HRSG SYSTEM USING INLET GUIDE VANE (전치 가이드 베인 설치에 따른 열회수 보일러 입구 온도 최적화)

  • Lee, Soo-Yoon;Ahn, Joon;Shin, Seung-Won
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03a
    • /
    • pp.148-154
    • /
    • 2008
  • Diverging channel from gas burner exit to the inlet section of Heat Recovery Steam Generator (HRSG) has been re-designed for 1 MW system. To improve the uniformity in velocity and temperature distribution of existing design(Case A and B) of 300 kW HRSG system, two additional test geometries have been chosen for the numerical simulation. At first, gas burner exit section has been centered to the inlet section of boiler(Case C) and uniformity has been improved considerably. Secondly, the diverging channel length can be further reduced for compact geometry with new guide vane design (Case D and E). Proposed design shows overall improvement in uniformity in velocity and temperature distribution compared to existing one.

  • PDF

NUMERICAL OPTIMIZATION OF TEMPERATURE DISTRIBUTION IN HRSG SYSTEM USING INLET GUIDE VANE (전치 가이드 베인 설치에 따른 열회수 보일러 입구 온도 최적화)

  • Lee, Soo-Yoon;Ahn, Joon;Shin, Seung-Won
    • Journal of computational fluids engineering
    • /
    • v.14 no.3
    • /
    • pp.1-8
    • /
    • 2009
  • Diverging channel from gas engine exit to the inlet section of Heat Recovery Steam Generator (HRSG) has been re-designed for 1 MW system. To improve the uniformity in velocity and temperature distribution of existing design(Case A and B), two additional test geometries have been chosen for the numerical simulation. At first, gas burner exit section has been centered to the inlet section of the boiler(Case C) and uniformity in velocity and temperature distribution has been improved considerably. Secondly, the diverging channel length can be further reduced to compact geometry with new guide vane design (Case D and E). Proposed design shows overall improvement in uniformity in velocity and temperature distribution compared to existing one.

Numerical Simulation of Duct Flow about Shape and Arrangement of Inlet Guide Vane to Increase the Temperature Uniformity (전치 가이드 베인 배치 및 형상에 따른 보일러 입구 온도분포의 수치해석 연구)

  • Lee, Su-Yun;Shin, Seung-Won
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1172-1177
    • /
    • 2008
  • Diverging channel from gas burner exit to the inlet section of Heat Recovery Steam Generator (HRSG) has been re-designed for 1 MW steam supply and power generation system. Three different test geometries have been chosen for the numerical simulation. The existing design for 300 kW HRSG system (CASE B) has been improved by geometry and position changes of inlet guide vanes along with gas velocity entrance angle at the diverging channel inlet (CASE C). Both cases has been compared with the case where hot combustion gas is directly injected without any guide vanes (CASE A). Improved design shows overall uniform velocity and temperature distribution compared to existing design.

  • PDF