• Title/Summary/Keyword: 임플란트 환자

Search Result 497, Processing Time 0.021 seconds

Deep learning algorithms for identifying 79 dental implant types (79종의 임플란트 식별을 위한 딥러닝 알고리즘)

  • Hyun-Jun, Kong;Jin-Yong, Yoo;Sang-Ho, Eom;Jun-Hyeok, Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.4
    • /
    • pp.196-203
    • /
    • 2022
  • Purpose: This study aimed to evaluate the accuracy and clinical usability of an identification model using deep learning for 79 dental implant types. Materials and Methods: A total of 45396 implant fixture images were collected through panoramic radiographs of patients who received implant treatment from 2001 to 2020 at 30 dental clinics. The collected implant images were 79 types from 18 manufacturers. EfficientNet and Meta Pseudo Labels algorithms were used. For EfficientNet, EfficientNet-B0 and EfficientNet-B4 were used as submodels. For Meta Pseudo Labels, two models were applied according to the widen factor. Top 1 accuracy was measured for EfficientNet and top 1 and top 5 accuracy for Meta Pseudo Labels were measured. Results: EfficientNet-B0 and EfficientNet-B4 showed top 1 accuracy of 89.4. Meta Pseudo Labels 1 showed top 1 accuracy of 87.96, and Meta pseudo labels 2 with increased widen factor showed 88.35. In Top5 Accuracy, the score of Meta Pseudo Labels 1 was 97.90, which was 0.11% higher than 97.79 of Meta Pseudo Labels 2. Conclusion: All four deep learning algorithms used for implant identification in this study showed close to 90% accuracy. In order to increase the clinical applicability of deep learning for implant identification, it will be necessary to collect a wider amount of data and develop a fine-tuned algorithm for implant identification.

Effect of open proximal contact on adjacent tooth and implant (개방된 인접면 접촉이 인접자연치와 임플란트에 미치는 영향)

  • Moon, Sohyun;Kim, Gwangyun;Cho, Seonghun;Song, Joohun;Kim, Hee-Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.1
    • /
    • pp.9-17
    • /
    • 2022
  • Purpose: The purpose of this study is to investigate how open contacts impact the natural teeth and dental implant prostheses. Materials and Methods: Following criteria were used to select 20 implant crowns with open proximal contacts as the experimental group (Group A): the restorations were delivered in Chosun University Dental Hospital between 2008 and 2018, the restorations are in the posterior region, opposing teeth are fixed dental prostheses, neighboring teeth are sound natural teeth, the patient had been on the maintenance program for at least 3 years. Another 20 implant crowns with closed proximal contacts were selected as the control group (Group B) using the same criteria. Between the two groups, dental caries and food impaction of the neighboring natural teeth and marginal bone-loss of the implants were compared and evaluated. Results: There was no statistically significant difference between Group A and Group B in the occurrence rates of dental caries, food impaction, and marginal bone-loss. The amount of marginal bone-loss, however, revealed statistically significant differences between the two groups, with Group A showing 0.80 ± 0.39 mm loss and Group B showing 1.1 ± 0.43 mm loss. Conclusion: Implant prostheses with open contacts could be clinically considered in select cases as such restorations revealed no harmful effects on neighboring teeth and implant restorations within the perimeters of this study.

Conversion of implant overdenture to an implant assisted removable partial denture in maxilla: case report (상악 임플란트 피개의치에서 임플란트 보조 국소의치로의 전환: 증례보고)

  • Seong-Soo Cho;Min-Gyu Song;Yoon-Hyuk Huh;Chan-Jin Park;Lee-Ra Cho;Kyung-Ho Ko
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.1
    • /
    • pp.54-63
    • /
    • 2024
  • The long-term use of an implant overdenture shows problems, such as wear of attachment, concentrated occlusal forces on the anterior teeth, fracture of artificial teeth and rotation of denture. By transitioning to an Implant-assisted removable partial denture (IARPD) using additional implant placement, the problems can be solved. In this case report, a transition was made from implant overdenture to IARPD utilizing surveyed crowns to distribute occlusal forces concentrated on anterior teeth and to prevent denture rotation in a skeletal Class III patient. Design of definitive prosthesis with appropriate function and aesthetics was determined through several stages of provisional restorations. In this case, appropriate posterior occlusion and maintenance of peri-implant bone level of definitive prosthesis were observed.

Improvement of peri-implant complications through customized prosthesis restoration allowing soft tissue space: a case report (연조직 공간을 허용하는 맞춤형 보철 수복을 통한 임플란트 주위 합병증의 개선 증례)

  • Jieun Song;Woohyung Jang;Chan Park;Kwidug Yun;Hyun-Pil Lim;Sangwon Park
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.4
    • /
    • pp.260-266
    • /
    • 2023
  • The concept of 'Implant Supracrestal Complex (ISC)' was introduced as a way to determine the impact of implant prosthetic design form on both short-term clinical outcomes and the long-term prognosis of bone and soft tissues around the implant. Implant-prosthesis-abutment complex design forms, such as implant-abutment design, junction, and location, can have important implications for the stable and healthy long-term maintenance of the tissues around the implant. In this case, a customized concave abutment and a prosthesis with an emergence angle of about 30 degrees were restored to a patient suffering from chronic soft tissue inflammation and pain after restoration of an implant prosthesis. It was confirmed that the new prosthesis improved complications by allowing sufficient bone and soft tissue space, achieved appropriate soft tissue sealing, and maintained the long-term stability of the implant.

Analysis of Patients with Dysesthesia after Mandibular Nerve Injury (하악신경 손상 후 발생한 감각부전 환자들에 대한 분석)

  • Choi, Young-Chan;Kwon, Jeong-Seung;Kim, Seong-Taek;Ahn, Hyung-Joon
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.4
    • /
    • pp.379-385
    • /
    • 2009
  • The purpose of this study was to present basic data that is needed in comprehension of dysesthesia after mandibular nerve injury and grasp meaning. We analyzed medical records of 59 patients who were diagnosed as dysesthesia after mandibular nerve injury from January 2007 to July 2009. The results are summarized as follows. 1. The most frequent cause was implant surgery (59%) and the most frequent injured branch of mandibular nerve was inferior alveolar nerve(81%). 2. The period passed after nerve injury showed significant interrelationship with level of pain. Visual Analogue Scale(VAS) increased from 4.82 to 6.91 after 6 month. 3. The period passed after nerve injury did not show significant interrelationship with recovery of dysesthesia. But, when conservative treatment was offered at earlier stage, ratio of patients who showed recovery of symptom tended to increase. 4. In computed tomography, level of invasion into inferior alveolar nerve canal did not show significant interrelationship with level of pain and recovery of dysesthesia. Conclusively, in the patients with dysesthesia of mandibular nerve, inferior alveolar nerve injury by dental implant surgery dominated most significant problem. Although level of invasion into inferior alveolar nerve is the most important factor to initiation of dysesthesia, there are other various factors exert more influence on the level of pain or recovery of dysesthesia. Therefore, begining conservative therapy at earlier stage is encouraged. Also, because nerve injuries can occur without direct invasion into nerve canal, so leaving enough safe space from nerve canal is needed for prevention of indirect nerve injury.

Maxillary anterior implant restoration with appropriate anterior guidance using T-Scan in a patient with full fixed prostheses (전악 고정성 보철 수복 환자에서 T-Scan 분석을 이용해 전-측방유도를 부여한 상악 임플란트 보철 수복)

  • Nam, Rae-Kyeong;Pang, Eun-Kyoung;Cho, Young-Eun;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.419-426
    • /
    • 2017
  • In implant restorations, it is difficult for the patient to percept any symptoms. In addition, they are absent of shock absorbers, which can lead to mechanical failure if stress distribution is not considered. Since maxillary anterior multiple-implant restorations play a significant role in guiding the functional movement of the mandible by distributing lateral force, it is crucial to form appropriate occlusion. The use of the T-scan system is more advantageous in assessing 'dynamic occlusion', such as the change of occlusion over time, the amount of tooth contact during functional movement, and assessing the occlusion in the less-visible posterior teeth. The case is reported as it has satisfactory results in harmonious anterior guidance of a maxillary anterior multiple-implant restoration using T-scan analysis.

Mandibular Implant-Supported Telescopic Overdenture using Gold Electroforming System : A Case Report (Gold Electroforming System을 이용한 하악 임플란트 지지 텔레스코프 피개의치)

  • Choi, Jee-Ha;Kim, Seung-Kyun;Yu, Byoung-Il;Ahn, Seung-Geun;Park, Ju-Mi;Song, Kwang-Yeob;Park, Charn-Woon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.193-201
    • /
    • 2008
  • In edentulous mandible, implant supported overdenture was considered as a first treatment option. In case of a implant supported telescopic overdenture, sufficient inter-arch space needs for arrangement of artificial teeth and attachment. Passive fit of the implant prosthesis is important factor for preventing mechanical failure. Gold Electroforming System is particularly useful to achieve a passive fit of telescopic attachment and results in precision marginal fit and the small thickness of the coping provides optimal space for narrow inter-arch space. This article presents that application of Gold Electroforming System can provide excellent esthetics and function on four-implant supported telescopic overdenture.

Full mouth rehabilitation of a patient using monolithic zirconia and dental CAD/CAM system: a case report (단일구조 수복용 지르코니아와 Dental CAD/CAM System을 이용한 전악 임플란트 고정성 보철 수복 증례)

  • Lee, Sang-Hoon;Yoon, Hyung-In;Yeo, In-Sung;Han, Jung-Suk;Kim, Sung-Hun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.3
    • /
    • pp.196-207
    • /
    • 2018
  • An accurate implant placement with ideal location is significant for long-term success of the implant. An exact evaluation of nearby anatomic structures such as quality of residual bone, an inferior alveolar bone and a maxillary sinus is required. For a prosthetic-driven treatment, planned surgery, precise prosthesis and communication with the patient are significant requisites especially for full-mouth rehabilitation. In this case, the patient with severe alveolar bone resorption had a CT guided surgery supported by CT data and the data from scanning diagnostic wax-up. Afterward, edentulous area was restored by full mouth implant-supported prosthesis by using monolithic zirconia and CAD/CAM technique. This paper reports the outcome of the procedure which was remarkable both esthetically and functionally.

Treatment plan for missing mandibular 4 incisors (하악 4전치 상실시 치료 계획)

  • Hahn, Kwang Jin
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.25 no.1
    • /
    • pp.25-34
    • /
    • 2016
  • Treatment of missing mandibular 4 incisors is often thought to be easier then other place during surgical and prothetic procedure. But clinicians encounter unexpected difficulties such as restricted implant site due to mesio-distal width of mandibular incisors, limited space as a result of crowing and mesial drift, esthetic problem after severe alveolar bone resorption, and difficulties of provisionalization Through cases, possible treatment options for missing mandibular incisors would be discussed. Treatment options for missing mandibular 4 incisors Place narrow type implant or one body mini implant on exact tooth position when there is no bone resorption Regular size implant on interseptal bone area when there is severe bone resorption Consider using resin bonded bridge(resin retained bridge/resin bonded fixed partial denture) as a tentative prosthesis when patient resists extracting remaining incisors with poor prognosis.

Posterior single implant prosthesis using scannable healing abutment (스캔이 가능한 치유지대주를 이용한 구치부 단일 임플란트 수복 증례)

  • Kim, Seong-Min;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.432-438
    • /
    • 2019
  • Accurate impression taking for the success of implant prosthesis is a very important process. Methods of taking implant impression include the conventional method using impression coping and impression material, and the digital method using an intraoral scanner and scanbody. However, the impression coping or the scanbody must install after remove healing abutment. Because of this, the dentist must repeat the process of removing and installing the healing abutment, the impression coping or the scanbody several times. In addition, the impression coping or the scanbody rises higher than the occlusal surface, so the patient has the inconvenience of constantly maintaining the open state. Recently, a scannable healing abutment, which can be scanned by a intraoral scanner directly, without the need to remove the healing abutment by applying a scannable part of the scanbody to the healing abutment, was introduced. We present a case of single posterior implant prosthesis using a scannable healing abutment.