• Title/Summary/Keyword: 임플란트 환자

Search Result 497, Processing Time 0.029 seconds

Prosthetic rehabilitation of marginal mandibulectomized patient using implant-supported removable partial denture (하악골 변연절제술 환자에서 임플란트를 지대치로 이용한 가철성 국소의치 수복 증례)

  • Baek, Chang-Hyun;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.126-131
    • /
    • 2016
  • Surgical management of oral cancer results in compromised masticatory and swallowing function which affects patient in social and psychological aspects due to reduced phonetic ability and facial deformity, thus, it is imperative to provide applicable prosthetic treatment to overcome such complications. This clinical study describes rehabilitation of a patient with squamous cell carcinoma treated with marginal mandibulectomy and implantation on preserved posterior portion of mandible to provide stability and support for subsequent denture treatment. Kennedy class IV removable partial denture has provided satisfactory results in esthetics and function. Bone level stability around implants was reported to be maintained during eight months of clinical observation.

Maxillary cement retained implant supported fixed prosthesis using the millingable Pd-Ag alloy generated by CAD/CAM system: clinical report after two years in service (상악 전부 무치악 환자에서 CAD/CAM 시스템으로 제작되는 Pd-Ag 합금을 이용한 고정성 임플란트 전악 수복 증례)

  • Lee, Jun-Sik;Han, Se-Jin;Choi, Yu-Sung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.71-80
    • /
    • 2014
  • Full-mouth reconstruction of a patient using dental implants is a challenge if there is vertical and horizontal bone resorption. Therefore, it is should be cautious in making the fixed prostheses that restore the function and the esthetics of the gingiva and teeth. In full mouth rehabilitation, CAD/CAM system makes it possible to fabricate restorations with high precision, regardless of span of the restoration. Recently, Palladium-silver (Pd-Ag) alloy which is highly biocompatible and millingable has been developed to compensate for the shortcomings of the titanium or zirconia. This clinical report presents the reconstruction of a maxillary arch with a cement retained implant supported fixed prosthesis using a Pd-Ag alloy generated by CAD/CAM system on eleven osseointegrated implants. The occluding surfaces were made of Pd-Ag alloy, to decrease the risk of chipping or fracture. The prostheses were esthetically pleasing, and no clinical complications have been reported after two years.

Implant overdenture treatment using Locator attachment system on edentulous patient (무치악 환자에서 로케이터 부착장치를 이용한 임플란트 피개의치 수복 증례)

  • Kim, Soo-Yeop;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.176-183
    • /
    • 2014
  • Severely absorbed edentulous ridge cannot bear mechanical stress, causes undesired transformation of oral environment and makes patients difficult to adapt to dentures. Nowadays implant overdenture can be a treatment of choice in order to relieve patients' discomfort and improve stability and retention of the denture. Placement of implant on maxilla is difficult because of its bone quality and anatomic structure. It also has wide supportive tissue and convenience of border sealing, which provides sufficient support and stabilization with conventional complete denture. Mandible, on the other hand, is difficult to obtain sufficient support, retention and stabilization with conventional complete denture. Therefore, implant overdenture is recommended on mandible. Locator attachment has been improved for convenience of use and male parts of various retention enabled it to replace ball type attachment clinically. In this study, we restored maxillary arch with conventional denture, and mandibular arch with implant and tissue-supported overdenture and Locator attachment system.

An efficient way of communication between dentists and dental technicians to ensure optimum clinical outcome with implant restorations (임플란트 보철물 제작시 치과의사와 기공사가 효과적으로 소통하는 한가지 방법)

  • Kim, Chonghwa
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.29 no.2
    • /
    • pp.66-74
    • /
    • 2020
  • Communication and cooperation between dentists and dental technicians are two essential elements for the fabrication of high quality 'custom' prosthesis. For successful communication and cooperation between the two groups, however, dentists and dental technicians must share common understanding about clinical dentistry. Ironically, it is often noticed that they are not really sharing the same clinical knowledge. Although there is a strong association between 'Emergence Profile' of implant prostheses and periodontal health or esthetics, no definite guideline has ever been provided for ideal emergence profile of implant prosthesis in literature. Problems resulted from inherent differences between implants and natural teeth must be acknowledged and shared between dentists and dental technicians so that they can come up with desirable clinical results with implant prostheses.

Retreatment of implant overdenture using Milled Bar and Attachment in a patient using a unilateral prosthetic arm: A case report (편측 의수 사용 환자에서 Milled Bar와 Attachment를 이용한 임플란트 피개의치 재수복 증례)

  • Park, So-Hyung;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Lee, So-Hyoun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.187-194
    • /
    • 2022
  • The use of implants could improve the support, retention, and stability of removable prosthetic restoration for fully edentulous patients with severe alveolar bone resorption. When the prosthesis is manufactured without accurate diagnosis and evaluation, this may lead to unfavorable treatment result. The patient in this case had the treatment of implant overdentures at a private dental clinic, but visited the hospital for retreatment due to soft tissue pain and decreasing retention of existing dentures. The vertical dimension was raised compared to the existing dentures, and overdentures were manufactured using milled bars and additional attachments. The clinical results were satisfactory in the aspect of improved oral hygiene maintenance, function and esthetics.

Fixed Prosthetic Restoration in an Edentulous Patient with NobelGuideTM System (양악 무치악 환자에서 NobelGuideTM 시스템을 이용한 고정성 임플란트 보철수복)

  • Shin, Hyoung-Joo;Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.3
    • /
    • pp.243-253
    • /
    • 2009
  • This report described a technique utilizing a computer-aided design (CAD) /computer-aided machining (CAM) - guided surgical implant placement and prefabricated fixed complete denture for an immediately loaded restoration. A patient with an edentulous maxilla and mandible received 6 implants in maxilla and 6 implants in the mandible using CAD/CAM surgical templates. Prefabricated provisional maxillary and mandibular implant supported fixed prostheses were connected immediately after implant installation. Provisional prostheses were evaluated for aesthetics, function during 6 months. Definitive prostheses were fabricated.

Osseointegration of dental implant in the mandible with diffuse sclerosing osteomyelitis: Report of a rare case (미만성 경화성 골수염을 동반한 하악에서 임플란트의 골유착)

  • Kang, Hyeon-Goo;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Cho, Lee-Ra;Park, Chan-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.314-318
    • /
    • 2021
  • There are very few reports of the restoration of tooth loss using dental implants in patients with diffuse sclerosing osteomyelitis (DSO). Because the patients with DSO have unfavorable bone quality for osseointegration of dental implants, additional considerations such as surgical trauma, infection control, and an extended healing period are essential when placing dental implants. The purpose of this study is to report on the success of osseointegration of a dental implant in the patient with DSO.

Full mouth rehabilitation of mandibular edentulous patient using implant hybrid prosthesis (하악 무치악 환자에서 임플란트 하이브리드 보철물을 이용한 전악 수복 증례)

  • Kim, Seong-Bin;Kim, Sung-Hoi;Park, Young-Bum;Moon, Hong-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.214-220
    • /
    • 2013
  • Implant prosthodontics is beneficial for edentulous patients in enhancing the support, retention, stability, phonation and so on. Various types of prosthesis supported by implant, including implant retained- or supported- overdenture for the removable type and ceramo-metal and fixed prostheses with processed acrylic teeth for the fixed type, are frequently used. Treatment planning for the prosthesis with implant must be made after considering individual characteristics such as form of residual ridge, soft tissue, interocclusal relationship, economic status. Fixed prosthesis with processed acrylic teeth (also known as 'implant hybrid prosthesis' or 'bone anchored bridge') has the advantages of both removable and fixed prosthesis such as proper soft tissue profile, esthetic outcome, increased masticatory efficiency and psychological stability. The 73-years-old female patient came to the department of prosthodontics, Dental hospital of Yonsei University. She was diagnosed with Kennedy class I partial edentulism in the maxilla and complete edentulism in the mandible. This article reports a satisfactory clinical and esthetic outcome of full mouth rehabilitation using removable partial denture in the maxilla and implant hybrid prosthesis in the mandible.

A Study on the Factors Giving Effects to Patient's Satisfaction in the Selection of Implant Operation (임플란트 시술선택에 있어 환자 만족도에 영향을 미치는 요인)

  • Kim, Gi-Ug;Choi, Sung-Mi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4354-4359
    • /
    • 2010
  • The study performed questionnaire to the patients receiving implant operation, who visited dental clinics and hospitals(2 hospitals and 5 clinics) from Jul. 1, 2009 to Sep. 12, 2009 in order to study the factors giving effects to patient's satisfaction in the selection of implant. 145 questionnaire papers collected from patients were analyzed with SPSS12.0 program. The result revealed that the satisfaction with implant operation was usually normal when implant was operated because of tooth extraction due to dental caries and periodontal disease and it was usually high when implant was operated because of wound(P<0.05). When considering each cause of tooth extraction, the satisfaction with pronunciation function was usually normal(P<0.001), the satisfaction with functional part including foreign body sense was very low when the cause of operation was periodontal disease(P<0.01). The satisfaction with hospital environment depending on the cause of hospital selection was usually high when hospital was selected because of doctor's fame. It was low when hospital was selected because it was close to home(P<0.001). The satisfaction with the number of hospital visits depending on the number of implanted teeth was usually low when many teeth were implanted(P<0.01). The analysis on the satisfaction with tooth shape and color showed that the satisfaction was high when '1~2' teeth and 'more than 6' teeth were implanted(P<0.05). In order to improve patient's satisfaction with implant, it is necessary to recognize individual's oral status and request correctly. It is determined that proposal of operation period, number of hospital visits, function and expected aesthetic satisfaction degree will contribute to the improvement of mutual reliance between doctor and patient and post-operation satisfaction degree.

Deviations of Implant Position between Pre- and Post-operation in Computer-guided Template-based Implant Placement (Computer-guided template를 이용한 임플란트 식립에서 술 전과 술 후 사이의 임플란트 위치에 따른 변위량 검사)

  • Kim, Won;Kim, Seung-Mi;Kim, Hyo-Jung;Song, Eun-Young;Lee, Si-Ho;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.175-184
    • /
    • 2011
  • With a development of implant restoration technique, there are increasing use of computer-guided system for edentulous patients. It was carried out simulated operation based on CT information about patient's bone quantity, quality and anatomical landmark. However, there are some difference between the programmed implant and post-operative implant about it's position. If the deviation was severe, it could happen a failure of 'passive fit' and not suited for path of implant restoration. The aim of this presentation is to evaluate about a degree of deviations between programmed implant and post-operative implant. Five patients treated by 'NobelGuide' system (Nobel Biocare AB, G$\ddot{o}$teborg, Sweden) in Department of Prosthodontics, Inha University were included in this study. The patients were performed CT radiograph taking and intra-oral impression taking at pre-operation. Based on CT images and study model, surgical stent was produced by NobelBiocareTM. To fabricated a pre-operative study model, after connected lab analog to surgical template, accomplished a pre-operative model using type 4 dental stone. At final impression, a post-operative study model was fabricated in the conventional procedures. Each study model was performed CT radiograph taking. Based on CT images, each implant was simulated in three dimensional position using $Procera^{(R)}$ software (Procera Software Clinical Design Premium, version 1.5; Nobel Biocare AB). In 3D simulated model, length and angulation between each implant of both pre- and post-operative implants were measured and recorded about linear and angular deviation between pre-and post-operative implants. A total of 24 implants were included in this study and 58 inter-implant sites between each implant were measured about linear and angular deviations. In the linear deviation a mean deviation of 0.41 mm (range 0~1.7 mm) was reported. In the angular deviation, a mean deviation was $1.99^{\circ}$ (range $0^{\circ}{\sim}6.7^{\circ}$). It appears that the both linear and angular mean deviation value were well acceptable to application of computer-guided implant system.