• Title/Summary/Keyword: 임플란트 형태

Search Result 195, Processing Time 0.025 seconds

Implant stability evaluation according to the bone condition, fixture diameter and shape in the osseointegration simulated resin model (골유착 재현 레진 모델에서 골 상태 및 임플란트 형태에 따른 임플란트 안정성에 관한 연구)

  • Kwon, Taek-Ka;Yeo, In-Sung;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.128-137
    • /
    • 2011
  • Purpose: Resonance frequency analysis, Periotest, and removal torque (RT) test were known as the methods to assess implant stability. The results of these methods are affected by the bone condition, implant diameter and shape. The purpose of this study is to access the meaning and the correlationship of the resonance frequency analysis, Periotest and RT test in osseointegration simulated acrylic resin when the engaged bone thickness and peri-implant bone defect are changed. Materials and methods: To simulate osseointegration, the fixture was fixed to an aluminum mold with a screw. Acrylic resin powder and liquid were poured into the mold for polymerization. The engaged resin thickness with implant was controlled. Simulated cortical bone thicknesses were 1, 3, 5 and 10 mm. Additional 1, 3 and 5 mm peri-implant bone defects were simulated. Three types of implants were used; 4 mm diameter implants of straight shape, 4 mm diameter implants of tapered shape and 5 mm diameter implants of tapered shape. Five fixtures per each type were tested in respective bone condition. Resonance frequency analysis and Periotest were evaluated in all bone conditions. Peak removal torque was measured at simulated cortical bone thicknesses of 1 and 3 mm. The statistical analysis was performed with the Kruskal-Wallis test, Mann-Whitney U test, and Spearman test using a 95% level of confidence. Results: With increasing engaged bone depth, the Implant Stability Quotient (ISQ) values increased and the Periotest values (PTVs) decreased (P<.001, P<.001). With increasing peri-implant bone defect, ISQ values decreased and PTVs increased (P<.001). When the diameter of implant increased, ISQ values increased and Periotest values (PTV) decreased (P<.001). There was a strong correlation between ISQ values and PTVs (r = -0.99, P<.001). Furthermore, the peak removal torque values had weak correlations with both ISQ values and PTVs (r = 0.52, P<.001 ; r = -0.52, P<.001). Conclusion: This study confirmed favorable implant stability with increasing engaged bone depth and implant diameter and decreasing peri-implant bone defect. ISQ values and PTVs showed strong correlation with each other and not with the peak removal torque values.

Implant Supported Overdenture using Locator$^{(R)}$ System on Mandibular Edentulous Patient (하악 무치악 환자에서 Locator$^{(R)}$를 이용한 임플란트 피개의치 수복 증례)

  • Yu, Jung-Hyun;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.4
    • /
    • pp.397-406
    • /
    • 2012
  • Loss of tooth results in remodeling and resorption of surrounding alveolar bone which causes atrophic edentulous ridge and gradually decreasing gingival attachment. As a result, edentulous patients face difficulty in using dentures due to pain, decrease of support, decline of masticatory efficiency of complete denture. To improve this, overdenture with implant in the mandible and attachment are considered as a treatment of choice as a favorable treatment. In this case, a patient with edentulous ridge for long period is rehabilitated by complete denture in maxilla and implant overdenture using Locator$^{(R)}$ attachment in mandible.

Implant prosthesis for fully edentulous patients using intra-oral scanning and abutment merging technique: A case report (무치악 환자에서 구강 스캔과 지대주 중첩을 이용한 임플란트 보철수복 증례)

  • Hwang, Chan-Hyeon;Jeong, Seung-Mi;Kim, Yong-Jun;Kim, Kyeong-Hee;Fang, Jeong-Whan;Kim, Dae-Hwan;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.61-70
    • /
    • 2017
  • In this case, the impression surface of the existing denture was scanned and was inverted three-dimensionally to express the residual ridge form. Implant planning was performed on the superimposed data of the CT with the scanned image of the denture with radiopaque markers attached. At the day of surgery, customized abutments fabricated in accordance with the form of the gingival margin were linked with fixtures and temporary restorations were set. In the process of fabricating the final prosthesis after the osseointegration of implant fixture, the intraoral scan images at abutment level were merged with images of the abutments scanned and stored before implant surgery. By fabricating the final prosthesis with the abutments obtained by merging can increase the marginal fitness of the final prosthesis and simplify the clinical process.

Flapless implant placement with digital 3D imaging and planning system in fully edentulous patient: A case report and 5-year follow-up (완전무치악 환자에서 디지털 가이드 수술 방식을 이용한 무피판절개 임플란트 식립증례: 증례보고 및 5년 추적관찰)

  • Shin, Mi-sun;Paek, Janghyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.312-320
    • /
    • 2019
  • One of the fastest growing segments of implant dentistry is the utilization of computed tomography (CT) scan data and treatment planning software in conjunction with guided surgery for implant reconstruction cases. Computer assisted planning systems and associated surgical templates have established a predictable, esthetic, functional technique for placing and restoring implants. Especially, a philosophy of restoratively driven implant placement has been generally adopted. Recently, a variety of commercial dental fields have released their scanning and fabricating protocols and methods for restorations. This process is still being investigated and developed for the most precise and predictable outcome. This case report describes a female patient who wanted dental implants in fully edentulous areas. Restoratively driven implant placements were performed with surgical guide and the patient was fully satisfied with the clinical results, and at 5-year post restorative follow-up assessment, both implant and prosthesis were proved clinical success.

Intrusion phenomenon of natural tooth bounded by implant-prostheses: a clinical report (임플란트 사이에 있는 자연치 함입 증례)

  • Kim, Joong-Hyun;Yang, Sun-Bong;Jo, Young-Sung;Park, Young-Bum
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.324-330
    • /
    • 2014
  • In case of implant-tooth connected prosthesis, a natural tooth tends to intrude. There are several mechanisms that explain an intrusion phenomenon. So it is reco mmended not to connect an implant with a natural tooth. A 68-year-old female had upper left $2^{nd}$ premolar and $2^{nd}$ molar extracted and underwent implant surgery on the missing area. We made an implant prosthesis and treated upper left $1^{st}$ molar with a gold crown. 2.5 year later, the patient complained about loose proximal contact and food impaction between upper left $1^{st}$ molar and $2^{nd}$ molar. Mesial side of upper left $2^{nd}$ molar implant prosthesis was soldered so that proximal contact became tight again. But after 7 months, about 2 mm intrusion of upper left $1^{st}$ molar occurred, and the patient felt periodontally originated pain on intruded upper left $1^{st}$ molar. After the gold crown on upper left $1^{st}$ molar was removed, extrusion occurred and pain was relived.