• Title/Summary/Keyword: 임플란트 식립위치

Search Result 137, Processing Time 0.019 seconds

디지털 가이드 시스템과 사전 제작된 임플란트 상부보철물을 이용한 전치부의 임플란트 수복 : 증례보고

  • Choi, Yongkwan
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.30 no.1
    • /
    • pp.24-32
    • /
    • 2021
  • Dental implant have been in use for a long time to restore at missing tooth. But, To place dental implant at good position very is difficult. Improperly positioned dental implants make some problems to have a good function of dental implant. so, To place dental implant at accurate position is the most important step throughout the whole process. Digital guided system of dental implant is very useful to have a accurate position of dental implant and it makes upper restoration more esthetic and funcional.

The use of surgical guide stent for implant placement (임플란트 식립을 위한 수술 가이드의 사용)

  • Lee, Ji-Yeon;Yoon, Ji-Young;Oh, Namsik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.366-375
    • /
    • 2014
  • Surgical guide not only provide diagnosis and treatment plan, but even location and direction of implantation. Surgical guide could be divided into non-limited design, partially limited design, and completely limited design. Partially limited design is easily manufactured and inexpensive but less accuracy, compared to completely limited design. From this approach, partially limited design may be particularly effective in patients who present with a single missing tooth or partially edentulous teeth. Completely limited design is anatomically accuracy, esthetical and functional, optimized treatment for prosthetic and biomechanical perspective, and also minimizes discomfort for post-treatment. The purpose of this study is to review previous studies of various surgical guides and applying in clinic.

The effects of local factors on the survival of dental implants: A 19 year retrospective study (임플란트의 생존율에 영향을 미치는 국소적 인자에 대한 19년간의 후향적 연구)

  • Kim, Sung-Hoi;Kim, Sun-Jai;Lee, Keun-Woo;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.28-40
    • /
    • 2010
  • Purpose: The aim of this retrospective study was to provide long-term data about the correlation between multifactorial local factors and the survival of implants. Material and methods: During 19 years (1991 to 2009), 2796 implants were placed in 879 patients. From dental charts and radiographs, the following data were collected: patient's age at implant placement, gender, implant system, surface, length, diameter, location of implant placement, bone quality, primary stability, type of prosthesis. The correlations between these data and implant survival were analyzed. Statistical analysis was performed using Kaplan-Meier survival analysis, Chi-square test, odds ratio. Results: 1. Among the 2796 implants, 150 implants failed that resulted in a cumulative survival rate of 94.64%. The cumulative survival rate of smooth surface implants (91.76%) was lower than rough surface implants (96.02%). 2. Anatomic location, implant surface, diameter of smooth surface implant, primary stability, type of prosthesis, patient's age and gender were significantly associated with implant survival (P < .05). 3. No significant difference in implant survival was found in relation to the following factors: implant length, bone quality, diameter of rough surface implants and type of rough surface according to implant manufacturer (P < .05). Conclusions: Local factors such as anatomic location, implant surface, diameter of smooth surface implant, primary stability and type of prosthesis have a significant effect on implant survival.

Deviations of Implant Position between Pre- and Post-operation in Computer-guided Template-based Implant Placement (Computer-guided template를 이용한 임플란트 식립에서 술 전과 술 후 사이의 임플란트 위치에 따른 변위량 검사)

  • Kim, Won;Kim, Seung-Mi;Kim, Hyo-Jung;Song, Eun-Young;Lee, Si-Ho;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.175-184
    • /
    • 2011
  • With a development of implant restoration technique, there are increasing use of computer-guided system for edentulous patients. It was carried out simulated operation based on CT information about patient's bone quantity, quality and anatomical landmark. However, there are some difference between the programmed implant and post-operative implant about it's position. If the deviation was severe, it could happen a failure of 'passive fit' and not suited for path of implant restoration. The aim of this presentation is to evaluate about a degree of deviations between programmed implant and post-operative implant. Five patients treated by 'NobelGuide' system (Nobel Biocare AB, G$\ddot{o}$teborg, Sweden) in Department of Prosthodontics, Inha University were included in this study. The patients were performed CT radiograph taking and intra-oral impression taking at pre-operation. Based on CT images and study model, surgical stent was produced by NobelBiocareTM. To fabricated a pre-operative study model, after connected lab analog to surgical template, accomplished a pre-operative model using type 4 dental stone. At final impression, a post-operative study model was fabricated in the conventional procedures. Each study model was performed CT radiograph taking. Based on CT images, each implant was simulated in three dimensional position using $Procera^{(R)}$ software (Procera Software Clinical Design Premium, version 1.5; Nobel Biocare AB). In 3D simulated model, length and angulation between each implant of both pre- and post-operative implants were measured and recorded about linear and angular deviation between pre-and post-operative implants. A total of 24 implants were included in this study and 58 inter-implant sites between each implant were measured about linear and angular deviations. In the linear deviation a mean deviation of 0.41 mm (range 0~1.7 mm) was reported. In the angular deviation, a mean deviation was $1.99^{\circ}$ (range $0^{\circ}{\sim}6.7^{\circ}$). It appears that the both linear and angular mean deviation value were well acceptable to application of computer-guided implant system.

Oral rehabilitation of edentulous patient with mandibular implant overdenture using surgical guide (서지컬 가이드를 이용한 하악 임플란트 피개의치 수복 증례)

  • Lee, Dong Hwan;Ryu, Jae Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.339-346
    • /
    • 2022
  • Compared with traditional full dentures, mandibular implant overdentures have the advantage in that good support and retention can be obtained even with two implants. When manufacturing a mandibular implant overdenture using two implants, it is important to place the implant in the correct position. The long-term prognosis of overdenture is good when two implants are placed in the direction vertical to the occlusal plane and parallel to each other at the canine position. However, it is difficult to place two implants in the correct position in edentulous patients, and if you use surgical guides in these cases, you can get help in placing the implants in a prosthetically advantageous position. This case, a 57-year-old male patient, came to our hospital with all upper and lower teeth removed due to periodontal disease. Therefore, the maxilla was restored with a traditional full denture and the mandible was restored with an implant overdenture using two implants, which resulted in satisfactory functional and esthetic results.

Rehabilitation with implant-supported fixed dental prostheses using digital duplication technique on customized artificial tooth, interim denture and implant surgical template: A case report (디지털 복제로 만든 맞춤형 인공치로 제작한 임시의치와 임플란트 수술용 템플릿을 통한 임플란트 지지형 고정성 보철 수복 증례)

  • Jeong, Dae Gil;Oh, Kyung Chul;Shim, June Sung;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.397-404
    • /
    • 2019
  • Bone and soft tissue conditions are important for successful implant treatment. But, the placement itself is also very important. Implants which is installed in the wrong position result in the biological, esthetical and mechanical problems. In order to place an implant in the correct position, the final restoration and diagnostic wax-up should be considered prior to the surgery. If the artificial teeth for the interim denture are directly transferred from the diagnostic wax-up, the operator can try the form of diagnostic wax-up in the mouth. If the surgical template is produced by duplicating the interim denture, the implant can be placed in the planned position. In this case, the polymethyl methacrylate (PMMA) artificial tooth was precisely milled by the digital duplication of diagnostic wax-up. And interim denture was fabricated by using these milled teeth. After the patient adapted for a sufficient period, the implant was placed at the planned position with surgical template produced by duplicating the interim denture. After confirming sufficient osseointegration, the final prostheses were made to reflect the shape of diagnostic wax-up. Through this procedure, the satisfactory functional and esthetic outcome could be acquired.

Esthetic implant restoration in the maxillary anterior missing area with palatal defect of the alveolar bone: a case report (구개부 치조골 결손을 보이는 상악 전치 상실부의 임플란트 심미보철수복: 증례보고)

  • Oh, Jae-Ho;Kang, Min-Gu;Lee, Jeong-Jin;Kim, Kyoung-A;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.291-298
    • /
    • 2017
  • It is challenging to produce esthetic implant restoration in the narrow anterior maxilla region where insufficient volume of alveolar bone could limit the angle and position of implant fixture, if preceding bone augmentation is not considered. Ideal angle and position of implant fixture placement should be established to reproduce harmonious emergence profile with marginal gingiva of implant prosthesis, bone augmentation considered to be preceded before implant placement occasionally. In this case, preceding bone augmentation has been operated before esthetic implant prosthesis in narrow anterior maxilla region. Preceded excessive bone augmentation in buccal area allowed proper angulation of implantation, which compensates unfavorable implant position. Provisional restorations were corrected during sufficient period to make harmonious level of marginal gingiva and interdental papilla. The definite restoration was fabricated using zirconia core based glass ceramic. Functionally and esthetically satisfactory results were obtained.

A retrospective study on survival rates of dental implants in elderly patients (노인 환자에서 임플란트의 생존율에 대한 후향적 연구)

  • Shin, Hee-Jong;Yu, Sang-Joun;Kim, Byung-Ock
    • The Journal of the Korean dental association
    • /
    • v.53 no.5
    • /
    • pp.326-347
    • /
    • 2015
  • 목적: 노인 환자에서 식립된 임플란트의 생존율을 조사하고 다양한 요인에 따라 생존율에 미치는 영향을 후향적으로 평가하고자 하였다. 재료 및 방법: 2001년 1월부터 2007년 12월까지 조선대학교 치과병원 치주과에 내원한 65세 이상 노인 환자 56명에게 식립된 138개의 임플란트를 대상으로 하였다.(남자 38명, 여자 18명, 평균 연령$69.38{\pm}3.91$세) 임플란트 생존율은 환자 성별 및 연령, 전신질환 유무, 치아 상실 원인, 식립 위치, 임플란트 직경 및 길이, 골질, 골이식 여부, 상부 보철물 유형에 따라 조사되었다. Kaplan-Meier survival analysis을 통해 각 요인에 따른 누적 생존율을 조사하였고, chi-square test를 통해 누적 생존율과 각각의 요인 간의 통계학적 유의성을 평가하였다. 결과: 보철물 시적 후 5 ~ 140개월 간 추적 관찰을 시행하였다. 65세 이상 노인 환자 56명에게 식립된 총 138개의 임플란트 중 추적 관찰 기간 동안 5개의 임플란트가 실패하였다. 그 중 63개의 임플란트는 환자가 정기적인 내원 약속에 응하지 않아 도중에 조사대상에서 제외되었으며, 결과적으로 5년간 누적 생존율은 94.9%였다. 임플란트 생존율에 영향을 미치는 다양한 요인 중 골질 (P=0.037) 및 상부 보철물 유형 (P=0.015) 간에 누적 생존율이 통계적으로 유의한 차이가 있었다. 그외 연령, 성별, 전신질환 유무, 치아상실 원인, 식립 위치, 임플란트 직경 및 길이, 골이식 유무 관련 요인과 누적 생존율 사이에는 통계적으로 유의한 차이가 없었다. 결론: 여러 한계가 있었지만 노인 환자의 무치악 부위에 있어 임플란트는 장기간에 걸쳐 예지성 있고 받아들여질 만한 치료이면서 적은 합병증과 실패율을 가진다.

Flapless implant surgery on atrophied alveolar ridge in a patient with growth disorder (성장 장애를 가진 부분 무치악 환자에서 위축된 골에 무피판 임플란트 수술 증례)

  • Lee, Du-Hyeong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.170-175
    • /
    • 2014
  • The growth disorder influences craniofacial development and early loss of permanent teeth. This case reports the importance of computerized tomography (CT) and surgical guide to identify horizontal bone loss, adjacent teeth and to guide drills when placing implants in a short stature patient. The patient has idiopathic short stature and the 3rd grade of intellectual disability. To recover posterior mandibular teeth, implant treatment was planned. CT images showed that the adjacent teeth were located markedly to the buccal side. A CT-based surgical guide was fabricated and implants was placed using flapless surgery. Bone dehiscence and fenestration may happen when the surgical guide was fabricated just based on adjacent clinical crowns. Thus, it is essential to analysis bone and teeth and to make surgical guide through CT, especially in atrophied bone on grow disorder patients. Furthermore, systematic researches are recommended to elucidate the relationship between growth disorder and tooth malposition.

Application of dental implant for orthodontic anchorage (보철 수복용 임플란트의 교정치료를 위한 고정원의 활용)

  • Kang, Hyo-Jin;Park, Eun-Jin;Kim, Sun-Jong;Pang, Eun-Kyoung
    • The Journal of the Korean dental association
    • /
    • v.54 no.6
    • /
    • pp.404-413
    • /
    • 2016
  • Currently, dental implants have become predictable and reliable adjuncts for oral rehabilitation. Osseointegrated implants can be used to provide rigid orthodontic anchorage and have advantages compared conventional orthodontic anchorage especially when there were edentulous areas and implants were scheduled as a treatment plan. Orthodontic force doesn't cause the bone loss of osseointegrated implants. Implant materials, surgical protocols and healing time before loading follow the conventional treatment protocol. Because the implants, once installed, can't change the location, meticulous treatment planning should be preceded. Further investigations are needed to standardize the treatment protocol.

  • PDF