• Title/Summary/Keyword: 임펠러(impeller)

Search Result 389, Processing Time 0.02 seconds

Optimum Design of a Cross Flow Fan (횡류팬의 최적설계방안)

  • Kim D. H.;Park H. K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.08a
    • /
    • pp.176-181
    • /
    • 2003
  • The cross-flow fans are widely used in various applications, due to their large capacity of mass flow and the size compactness. The flow fields of the cross-flow fan is, however, complex and it has many design parameters. Thus the general design guide has not sufficiently established yet, and the design strategies of cross-flow fans have been based on experiments. In the present study, the cross-flow fan performance and its two-dimensional flow characteristics are numerically analyzed by using the STAR-CD. The simulation is done by varying the several design parameters such as impeller blade shapes, the gap between the stabilizer and impeller. The computational results are compared with the experimental data at the fan outlet region. Finally some helpful guides for the optimum design of the cross-flow fan are proposed.

  • PDF

Unstable Flow in a Vaneless Diffuser of 2-Dimensional Centrifugal Compressor (2차원 원심 압축기의 깃 없는 디퓨저에서의 불안정 유동)

  • Kang, Kyung-Jun;Shin, You-Hwan;Kim, Kwang-Ho;Lee, Yoon-Pyo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.4
    • /
    • pp.5-11
    • /
    • 2011
  • This study investigated on details of flow characteristics in a vaneless diffuser of a compressor with 2-dimensional impeller at various flow rates. Experiment for a low speed compressor model in a water reservoir was performed to analyze the flow field in the vaneless diffuser and volute casing, which was done by PIV measurement. It was also focused on the periodic flow patterns occurring at low flow rate near unstable operating region of the compressor. At low flow rate condition, the flow visualization clearly shows that the flow energy from impeller is highly accumulated at the compressor exit by the blockage effect of a flow damper and consequently the reverse flow occurs in the diffuser.

Design of a Impeller Hub Cold Forging Process (토크 컨버터용 임펠러 허브의 냉간단조공정설계)

  • Kim, Young-Suk;Kim, Hyun-Soo;Kim, Chan-Il;Choi, Suk-Tak
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.11
    • /
    • pp.213-219
    • /
    • 2000
  • A impeller hub is usually made through three forging processes : forward extrustion, upsetting and finishing. The finishing process is closed die forging in which the load increases abruptly at the final stage, resulting in underfilling in the finished product due to insufficient load capacity of the press. In this study, the rigid-plastic finite element analysis was applied to the impeller hub forging process in order to optimize process and to estimate required load. As a result, two kind of improvements for the process were suggested to reduce the load requirement in the finishing process.

  • PDF

Performance Analysis based on Impller Inlet & Outlet Angle for Waterjet (워터제트의 임펠러 입구와 출구 각도에 따른 성능해석)

  • Kang, Min-Kyu;Park, Dong-Jin;Kang, Han-Bin;Lee, Seok-Soon
    • Journal of Aerospace System Engineering
    • /
    • v.5 no.2
    • /
    • pp.27-32
    • /
    • 2011
  • The purpose of this study was to suggest 10 kinds of case and perform Mixed-flow pump optimum design and performance analysis depending on the shape of the impeller for suitable to water jet propulsion system. H20 was applied to the material properties, to analysis conditions for water jet axial impeller 1000 rpm given analysis was performed. Interpretation for each case as a result of speed, pressure, flow rate, calculate the thrust at the Inlet Angle $30^{\circ}$ and Outlet Angle $30^{\circ}$ could see a persistence of optimal performance.

Flow Characteristics Analysis of the Decontamination Device with Mixing and Diffusion Using Radio-Isotopes Tracer (방사성 동위원소를 이용한 제염제 혼합확산장치의 유동특성분석)

  • Oh, Daemin;Kang, Sungwon;Kim, Youngsug;Jung, Sunghee;Moon, Jinho;Park, Jangguen
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.5
    • /
    • pp.282-287
    • /
    • 2017
  • The purpose of this study was predicted the effects of mixing and diffusion due to the operation of the apparatus before the development of the mixed diffusion device for the decontamination absorbent to minimize the influence of contaminant inflow due to radiation accident. The tracer used for the flow characteristics was $^{68}Ga$, $^{99m}Tc$, which is a radioactive isotope, and 2 inch NaI radiation detector was used to detect it. The impeller of the decontamination mixed diffusion system applied to this study was made into three types and the mixing diffusion effect was compared. As a result of analyzing the flow characteristics of the radio-isotope with decontamination mixed diffusion device, mixing, diffusion and flow pattern were obtained. The radial mixing type impeller was able to diffuse to the water surface by the upflow flow, and the fin structure was adjusted for finding optimal conditions. The model 3 type consists of a fin guiding part and an auxiliary fin so that the diffusion speed is higher than that of other types of impellers. It also showed a short time to reach complete mixing.

DESIGNING EXPERIENCE OF AUTOMOTIVE TURBOCHARGER IMPELLER FOR FLANK MILLING (Flank Milling 공법적용을 위한 자동차용 터보차져 임펠러의 설계체험)

  • Bang, J.C.;Shuripa, V.A.
    • Journal of computational fluids engineering
    • /
    • v.18 no.4
    • /
    • pp.1-8
    • /
    • 2013
  • The performance of small-size impellers with ruled surfaces was investigated for flank milling over a wide speed range, using computational fluid dynamics analyses and gas bench tests. An impeller with a ruled surface was designed, manufactured, and tested to evaluate the effects of blade loading, the backsweep angle, and the relative velocity distribution on the compressor performance. The simulations and tests were completed using the same compressor cover with identical inlet and outlet channels to accurately compare the performance of the abovementioned impeller with a commercial impeller containing sculptured blades. Both impellers have the same number of blades, number of splitters, and shroud meridional profiles. The backsweep angles of the blades on the ruled impeller were selected to work with the same pinched diffuser as for a sculptured impeller. The inlet-to-exit relative velocity diffusion ratio and the blade loading were provided to maximize the flow rate and to minimize the surge flow rate. The design flow rate, rpm, were selected same for both impellers. Test results showed that for the compressor stage with a ruled impeller, the efficiency was increased by 0.32% with an extended surge margin without a reduction in the pressure ratio as compared to the impeller with the sculptured design. It was concluded that an increased relative velocity diffusion coupled with a large backsweep angle was an effective way to improve the compressor stage efficiency. Additionally, an appropriate blade loading distribution was important for achieving a wide operating range and higher efficiency.

A study on the vaneless diffuser and volute casing design for the improvement of small centrifugal compressors (소형 원심 압축기의 성능 향상을 위한 베인 없는 디퓨저와 볼류트 케이싱의 설계에 관한 연구)

  • Jo, Jae Phil;Paek, Seung Yun;Kim, Sung Don;Ahn, Kyubok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.3722-3730
    • /
    • 2015
  • The performance improvement of a small centrifugal compressor for waste water treatment has been conducted by the design change of vaneless diffuser and volute casing. Existing two compressors use a common impeller, but the width and length of the vaneless diffuser and the cross-sectional shape of the volute casing are different, respectively. Based on the experiment of the existing two compressors and their CFD results, the design of the vaneless diffuser and the volute casing has been changed. It was found that the strength of the interaction among the volute tongues, the vaneless diffusers and the impellers of two existing/one improved compressors, was affected by the cross-sectional area and inlet radial length of the volute casing including system losses' change. The efficiency of the impeller with one existing design was increased as the decrease of the width of the vaneless diffuser, but losses at the diffuser were accumulated. In conclusion, approximately 2.88%p efficiency increase at the design point of the new compressor with the improved design has been confirmed by CFD analysis results.

Effect of the Passage Area Ratio of an Impeller on the Performance of Two-Dimensional Centrifugal Compressors (임펠러의 유로 면적비가 2차원 원심압축기의 성능에 미치는 영향)

  • Park, Han-Young;Shin, You-Hwan;Choi, Hang-Cheol;Kim, Kwang-Ho;Chung, Jin-Taek
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.5
    • /
    • pp.22-29
    • /
    • 2008
  • This study is performed to understand the effect of the variation in the passage area of a two-dimensional impeller on its performance characteristics. We observe the results with changing the area ratio of inlet to outlet about $1{\sim}2.8$. A comparison between the experimental and numerical results was performed for the same configuration in order to verify the reliability of the CFD code. Overall characteristics in the passages of impeller were analyzed in detail including streamline, Mach number, pressure and polytropic efficiency distribution. When the passage area ratio exceeds 2, the pressure ratio is high. An area ratio of 2.3 showed the highest efficiency. The results will be used as useful reference data to establish the design concept of two-dimensional impeller and to improve its performance.

A Study on the Design for the Air Impeller of a Finishing Tool Unit (피니싱 툴 유니트의 에어 임펠러 설계에 관한 연구)

  • Choi, Hyun-Jin;Kang, Ik-Soo;Lee, Seung-Yong;Jang, Eun-Sil;Park, Sun-Myung;Choi, Seong-Dae
    • Korean Journal of Computational Design and Engineering
    • /
    • v.20 no.3
    • /
    • pp.312-319
    • /
    • 2015
  • The grinding and furbishing process as the finishing process for molds include the works such as the grinding, buffing, lapping and polishing among others. A finishing tool unit is applied to this finishing process for the burr, lapping, polishing and others of molds. A finishing tool unit can carry out the flexible machining, depending on the machining allowance for objects to be cut on the basis of the instrumental driving mechanism which enables the up, down, left and right floating, which is applied in link with the dedicated cutters and robot machining systems. This study selected the shape to increase the rotatory force of an impeller when air is discharged during the driving of a finishing tool unit, and reflected it to the impeller designing. In addition, the study analyzed each flow velocity and pressure distribution per air pressurization value and finally analyzed the rotating torque to suggest the optimal conditions in designing impellers.

Experimental Study on the Effect of Tip Clearance of a Centrifugal Compressor (팁 간극 영향으로 인한 원심 압축기 성능특성 시험연구)

  • Cha, Bongjun;Lim, Byungjun;Yang, Sooseok;Lee, Daesung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.4 no.1 s.10
    • /
    • pp.30-37
    • /
    • 2001
  • The experimental study on the effect of axial clearance between the tip of impeller blades and stationary shroud has been performed. The investigated compressor, which is a part of a small auxiliary power unit engine, consists of a curved inlet, a centrifugal impeller, a channel diffuser and a plenum chamber. It was designed for a total pressure ratio of 4.3 and an efficiency of $77\%$ at design speed of 60,000 rpm. The experiments are carried out in an open-loop centrifugal compressor test rig driven by a turbine. For the four different clearance ratios Cr(clearance/impeller tip width) of 6.25, 10.93, 15.60 and 20.30 percent, the overall performance data are obtained at $97\%,\;90\%$ and $80\%$ of the design speed. The results show the overall pressure ratio decrease of $7.7\%$ and the efficiency loss of $8.7\%$ across the variation of clearance ratio near the design speed. It also indicates that the influence of tip clearance became weaker as the flow rate is reduced and the stable operating range is not significantly influenced by the change of clearance ratio.

  • PDF