• Title/Summary/Keyword: 임시보철물

Search Result 176, Processing Time 0.02 seconds

Application of ARCUS digma I, II systems for full mouth reconstruction: a case report (ARCUS digma I, II system을 활용한 전악수복 증례)

  • Park, Chan
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.4
    • /
    • pp.345-350
    • /
    • 2016
  • Transferring condylar and anterior guidance on an articulator is essential to the diagnosis of a patient for full mouth reconstruction. In this clinical report, ARCUS digma I system was used to measure inherent condylar guidance of a patient requiring full mouth reconstruction in preoperate treatment, and the patients was given provisional restoration based on a functional anterior guidance. Then, ARCUS digma II system was used to mount the final casting model on an articulator, and the definitive prosthesis was placed in the patient. An esthetic and functionally proper clinical result regarding inherent condylar path of the patient was observed, and results from comparison of the two systems are given in this case.

Full mouth rehabilitation of severely worn dentition using posterior implants: a clinical report (심하게 마모된 치열의 구치부 임플란트 식립을 통한 전악 수복 증례)

  • Kang, Hyun-Sun;Lee, Cheol-Won;Lee, Won-Sup;Lee, Su-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.255-262
    • /
    • 2016
  • This clinical report focuses on the treatment of a patient with esthetic and functional impairments due to severe worn dentition. Absence of posterior support for a prolonged period require comprehensive prosthetic restoration. Accurate clinical and radiographic examinations, diagnostic wax-up, and occlusal vertical dimension evaluation were performed and the degree of patient adaptability was evaluated using an interim restoration. After 8 weeks of stabilization with interim restoration and confirmation of absence of any abnormal findings, definitive prostheses were fabricated. Satisfactory functional and esthetic outcomes were observed after 6 months of follow-up.

Influence of crown-to-implant ratio of short vs long implants on implant stability and marginal bone loss in the mandibular single molar implant (하악 구치 단일임플란트 수복에서 임플란트 길이에 따른 치관-임플란트 비율이 임플란트안정성 및 변연골소실에 주는 영향)

  • Baek, Yeon-Wha;Kim, Bongju;Kim, Myung-Joo;Kwon, Ho-Beom;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.280-289
    • /
    • 2018
  • Purpose: The purpose of this randomized clinical trial is to determine whether implant length and the crown-to-implant (C/I) ratio influence implant stability and peri-implant marginal bone loss (MBL). Materials and Methods: 46 patients with single tooth missing in the posterior molar region of the mandible were included in this study. 19 implants (CMI IS-III $active^{(R)}$ long implant) of 5.0 mm diameter and 10 mm length were installed for the control group, while 27 implants (CMI IS-III $active^{(R)}$ short implant) of 5.5 mm diameter and 6.6, 7.3 or 8.5 mm length were placed for the experimental group. Each implant was inserted and immediately loaded using the digitally pre-fabricated surgical template and provisional restoration. The CAD-CAM monolithic zirconia crown was fabricated at 3 months after the surgery as a definitive restoration. The ISQ value and the MBL was measured at 48 weeks after the surgery. The correlation between the C/I ratio, MBL, and secondary implant stability was analyzed. Results: Successful results in terms of ISQ and MBL were achieved with both groups. There was no significant difference between the groups in terms of ISQ values and MBL at 48 weeks after the surgery (P > 0.05). No significant correlation was found between the C/I ratio and secondary stability as well as the C/I ratio and the MBL (P > 0.05). Conclusion: The influence of C/I ratio in both groups was not shown on the stability nor the marginal bone loss in implants supporting single crown of the mandible. Short implant could be a preferable alternative option in the reduced bone height mandible under the limited condition despite its higher C/I ratio.

Application of Targis-Vectris Provisional Restorations for an Oro-Maxillofacial Cancer Patient: A Case report (악성암종 수술 환자에서 임시수복물로서 Targis-Vectris의 응용)

  • Kim, Jin-Man;Han, Jung-Suk;Lee, Sun-Hyung;Yang, Jae-Ho;Lee, Jae-Bong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.2
    • /
    • pp.113-118
    • /
    • 2002
  • Conventional radiograph, computed tomograph (CT), magnetic resonance image (MRI) are commonly used methods for diagnosis of oro-maxillofacial cancer. MRI is an effective tool to verify soft tissue lesion however, metal produces black artifacts in the image. Therefore, metal structure should be removed before taking MRI to diagnose head and neck cancer patients. A 52-year-old female patient with adenocarcinoma in the posterior right soft palate was referred to take a MRI before surgery. She has 7-unit porcelain fused to metal bridge in the maxilla. Eight-unit Tagis-Vectris fixed partial denture was fabricated to replace her existing PFM bridge to take a MRI without any artifact before and after surgery. The patient satisfied with her restorations in terms of esthetics, function after 11 months. Even though minor staining was detected, Tagis-Vectris restoration fixed partial denture was intact during observation period.

Three-dimensional finite element analysis according to the insertion depth of an immediately loaded implant in the anterior maxilla (상악 전치부 즉시하중 임플란트의 식립 깊이에 따른 삼차원 유한요소 분석)

  • Park, Cheol-Woo;Kim, Sung-Hun;Yeo, In-Sung;Yoon, Hyung-In;Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.105-113
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the effects of the insertion depth of an immediately loaded implant on the stress distribution of the surrounding bone and the micromovement of the implant using the three-dimensional finite element analysis. Materials and methods: A total of five bone models were constructed such that the implant platform was positioned at the levels of 0.00 mm, 0.25 mm, 0.50 mm, 0.75 mm, and 1.00 mm depth from the crest of the cortical bone. A frictional coefficient of 0.3 and the insertion torque of 35 Ncm were simulated on the interface between the implant and surrounding bone. A static load of 178 N was applied to the provisional prosthesis with a vertical load in the axial direction and an oblique load at $30^{\circ}$ with respect to the central axis of the implant, then a finite element analysis was performed. Results: The implant insertion depth significantly affected the stress distribution on the surrounding bone. The largest micromovement value of the implant was $39.34{\mu}m$. The oblique load contributed significantly to the stress distribution and micromovement in comparison to the vertical load. Conclusion: Increasing the implant insertion depth was advantageous in dispersing the concentrated stress in the cortical bone and did not significantly affect the micromovement associated with early osseointegration failure.

Influence of air abrasion and different dentin sealing techniques on microtensile bond strength to dentin (상아질의 봉쇄 시기와 표면처리 방법이 미세인장 결합강도에 미치는 영향)

  • Kang, Dong-Ho;Han, Chong-Hyun;Park, Jung-Won;Kim, Sun-Jai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.8-15
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate the effect of various methods of dentin bonding agent application and air abrasion pretreatment on microtensile bond strength between dentin and resin, using a self-etching adhesive system. Material and methods: Thirty freshly extracted human molars were obtained and divided into 6 groups of 5 teeth. A 2-step self etching adhesive system (Clearfil SE Bond) was used for all groups. The control specimens were prepared using a direct immediate bonding technique. The delayed dentin sealing specimens were prepared using an indirect approach without dentin prebonding. The immediate dentin sealing specimens were prepared using dentin prebonding immediately following preparation. Immediate dentin sealing teeth and delayed dentin sealing teeth had provisional restorations using Fermit for two weeks. Then all specimens of each group were divided into two groups of three, depending on air abrasion pretreatment. Composite "crowns" were incrementally built on and specimens were stored in water for 24 hours. All teeth were prepared for a microtensile bond strength test. Bond strength data were analyzed with a one-way ANOVA test, and post hoc comparison was done using the Scheffe's test. Results: The mean microtensile bond strengths of all groups were not statistically different from each other. Conclusion: When preparing teeth for indirect restorations, IDS and DDS with Clearfil SE bond, have no difference on the microtensile bond strength between dentin and resin. Air abrasion pretreatment did not affect the microtensile bond strength when using IDS and DDS with Clearfil SE bond.

ORAL REHABILITATION OF UNSTABLE OCCLUSION DUE TO SEVERELY DESTRUCTED FIRST PERMANENT MOLARS (제1대구치의 광범위 치관파괴로 인한 불안정한 교합의 재건)

  • Baik, Byeong-Ju;Lee, Sun-Young;Kim, Jae-Gon;Jeon, So-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.204-209
    • /
    • 2003
  • A 9-year old boy visited Department of Pediatric dentistry, Chonbuk National University Hospital due to unstable occlusion. He had permanent 1st molars destructed severely by dental caries and lost vertical stop. He could not occlude in the same position on closing of the jaw since he could not find his centric occlusion. The treatment plan was made, which was oral rehabilitation with crown restorations on permanent 1st molars based on clinical and radiographic examinations and centric relation of the jaw. Treatment plan consisted of endodontic treatment, crown lengthening and restoration of the occlusal vertical dimension (OVD) with gold crown by 3mm-increase of OVD. After endodontic and periodontal treatments, temporary crowns made of acrylic resin were set for assessment of tolerance to an increased OVD. After a month for tolerance, final prosthetics were made and set temporarily. In a month, gold crowns were set finally. Immediately after setting, the patient showed anterior open bite, but at the appointment after 4 months, he showed normal overjet, overbite and stable occlusion.

  • PDF

Effect of milling tool wear on the internal fit of PMMA implant interim prosthesis (밀링 공구의 마모가 PMMA 임플란트 임시보철물 변연 및 내면적합도에 미치는 영향)

  • Shin, Mi-sun
    • Journal of Technologic Dentistry
    • /
    • v.41 no.2
    • /
    • pp.63-69
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate the effect of CAD/CAM system milling tool wear on the marginal and internal fit of PMMA implant interim prosthesis three-dimensional manner. Methods: A total of 20 crowns were fabricated with CAD/CAM method. Their designs were unified to first molar of the left maxilla. The Customized abutments were prepared and scanned with on optical model scanner. Five crowns were milled by the newly replaced tool (1st milling), and 15 crowns were milled by 2nd, 3rd, 4th milling tool. The marginal and internal fit of 20 interim crowns were measured using the triple-scan protocol. Results: Statistically significant difference was found between the $1^{st}$ milling group ($51.8{\pm}14.6{\mu}m$) and the $3^{rd}$, $4^{th}$ milling group ($128.6{\pm}43.8{\mu}m$, $146.2{\pm}38.1{\mu}m$, respectively) at the distal margins. In the mesial margins, There was a statistically significant difference between the $1^{st}$ milling group ($63.6{\pm}25.9{\mu}m$) and the $3^{rd}$, $4^{th}$ milling group ($137.2{\pm}25.9{\mu}m$, $186.8{\pm}70.6{\mu}m$, respectively). In the distal line angle, significant difference was found between the $1^{st}$, $2^{nd}$, $3^{rd}$ milling groups and the $4^{th}$ milling group. In the mesial axial wall, significant difference was found between the $1^{st}$ milling group ($52.2{\pm}20.3{\mu}m$) and the $3^{rd}$, $4^{th}$ milling groups ($22.8{\pm}8.8{\mu}m$, $7.8{\pm}5.7{\mu}m$). Conclusion: As a result of the experiment, decrease of the marginal and internal fit was statistically significant as the number of machining cycles increased. In order to produce clinically excellent restorations, it is recommandable to consider the condition of the milling tool wear, when designing the restoration with CAD program.

Evaluation of marginal and internal accuracy of provisional crowns manufactured using digital light processing three-dimensional printer (DLP 방식의 3D 프린터로 제작된 임시 보철물의 변연 및 내면 정확도 평가)

  • Noh, Mi-Jun;Lee, Ha-Bin;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.44 no.2
    • /
    • pp.31-37
    • /
    • 2022
  • Purpose: The aim of this study was to evaluate the accuracy of provisional crowns manufactured using a milling machine and a digital light processing (DLP) printer. Methods: A full-contour crown was designed using computer-aided design software. Provisional crowns of this design were manufactured using a milling machine and using a DLP three-dimensional (3D) printer (N=20). The provisional crowns were digitized with an extraoral scanner, and 3D deviation analysis was applied to the scanned data to confirm their accuracy. An independent t-test was performed to detect the significant differences, and the Kolmogorov-Smirnov test was used for analysis (α=0.05). Results: No significant differences were found among the precision of marginal surface between the printed and milled crowns (p=0.181). The trueness of marginal and internal surfaces of the milled crowns were statistically higher than those of the printed crowns (p=0.024, p=0.001; respectively). Conclusion: The accuracy of provisional crowns manufactured using a milling machine and a 3D printer differed significantly except with regards to the precision of the internal surface. However, all the crowns were clinically acceptable, regardless of the manufacturing method used.

EFFECT OF TIME AND TEMPERATURE ON THE MARGINAL FIT OF PROVISIONAL RESIN CROWN DURING POLYMERIZATION (임시 수복물 중합시 시간과 중합온도가 변연 적합도에 미치는 효과)

  • Youn Seung-Hwan;Oh Nam-Sik;Kim Il-Kyu;Oh Sung-Seop;Choi Jin-Ho;Kim Wang-Sik;Rim Young-Il
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.5
    • /
    • pp.514-525
    • /
    • 2001
  • The purpose of this study was to compare the marginal fit of provisional restorations by differentiating the removal time and setting temperature during resin polymerization. After mixing autopolymerizing methyl methacrylate resin, the material was placed in a preformed resin shell crown. The crown was seated on a die with 1mm shoulder margin. Crowns were removed after 3, 4, 5, 6 minutes and polymerization was continued under the following conditions : $25^{\circ}C$ air, $30^{\circ}C,\;40^{\circ}C,\;50^{\circ}C,\;60^{\circ}C,\;70^{\circ}C$ water. After polymerization. the crown was sectioned. The marginal & occlusal discrepancies were measured. The mean marginal discrelpancies at 3 minutes, 4 minutes, 5 minutes and 6 minutes of removing time were $96.6{\mu}m.\;84.6{\mu}m,\;86.7{\mu}m$ and $105.6{\mu}m$. The mean occlusal discrepancies at 3 minutes, 4 minutes, 5 minutes and 6 minutes of removing time were $106.7{\mu}m,\;89.3{\mu}m,\;98.6{\mu}m$ and $127.7{\mu}m$. There was significant difference between 4 minutes group and 6 minutes group in occlusal discrepancies. The mean marginal & occlusal discrepancies for crowns polymerized in $25^{\circ}C$ air were $98.2{\mu}m$ and $124.1{\mu}m$. The crowns polymerized in $50^{\circ}C$ water demonstrated the smallest marginal & occlusal. discrepancies. The mean value of marginal & occlusal discrepancies in $50^{\circ}C$ water were $73.1{\mu}m$ and $77.5{\mu}m$. These values were smaller than that of $25^{\circ}C$ air. There were significant differences in the occlusal discrepancies between $25^{\circ}C$ air and water conditions of $50^{\circ}C$ water (${\alpha}=0.05$) but. no significant difference in marginal discrepancies. There was no significant difference in the interaction between time and temperature. 4 minutes waiting time & $50^{\circ}C$ water polymerizing condition produces the best fit at the margin of the provisional crown.

  • PDF