• Title/Summary/Keyword: 임상결과

Search Result 9,947, Processing Time 0.051 seconds

Isotope Ratio of Mineral N in Pinus Densiflora Forest Soils in Rural and Industrial Areas: Potential Indicator of Atmospheric N Deposition and Soil N Loss (질소공급, 고추의 생육 및 수량에 대한 녹비작물 환원 효과)

  • Kwak, Jin-Hyeob;Lim, Sang-Sun;Park, Hyun-Jung;Lee, Sun-Il;Lee, Dong-Suk;Lee, Kye-Han;Han, Gwang-Hyun;Ro, Hee-Myong;Lee, Sang-Mo;Choi, Woo-Jung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.1
    • /
    • pp.46-52
    • /
    • 2009
  • Deposition of atmospheric N that is depleted in $^{15}N$ has shown to decrease N isotope ratio ($^{15}N/^{14}N$,expressed as ${\delta}^{15}N$) of forest samples such as tree rings, foliage, and total soil-N. However, its effect on ${\delta}^{15}N$ of mineral soil-N which is biologically active N pool has never been tested. In this study, ${\delta}^{15}N$ of mineral N($NH{_4}^+$ and $NO_3{^-}$) in forest soils from organic and two depths of mineral soil layers (0 to 20 cm and 20 to 40cm depth) of Pinus densiflora stands located at two distinct areas (rural and industrial areas) in southern Korea was analyzed to investigate if there is any difference in ${\delta}^{15}N$ of mineral N between these areas. We also evaluated potential N loss of the study sites using ${\delta}^{15}N$ of mineral N. Across the soil layers, the ${\delta}^{15}N$ of $NH{_4}^+$ ranged from +8.9 to +24.8‰ in the rural area and from +4.4 to +13.8‰ in the industrial area. Soils from organic layer (+4.4‰) and mineral layer between 0 and 20 cm (+13.8‰) of industrial area showed significantly lower ${\delta}^{15}N$ of $NH{_4}^+$ than those of rural area (+8.9 and +24.3‰, respectively), probably indicating the greater contribution of $^{15}N$-depleted $NH{_4}^+$ from atmospheric deposition to forest in the industrial area than in the rural area. Meanwhile, ${\delta}^{15}N$ of $NO_3{^-}$ was not different between the rural and industrial areas, probably because ${\delta}^{15}N$ of $NO_3{^-}$ is more likely to be altered by the N loss that causes $^{15}N$ enrichment of the remaining soil N pool. Compared with the ${\delta}^{15}N$ of soil mineral N reported by other studies (from -10.9 to +15.6‰ for $NH{_4}^+$ and -14.8 to +5.6‰ for $NO_3{^-}$), the ${\delta}^{15}N$ observed in our study was substantially high, suggesting that the study sites are more subject to the N loss. It was concluded that $NH{_4}^+$ rather than $NO_3{^-}$ can conserve the ${\delta}^{15}N$ signature of atmospheric N deposition in forest ecosystems.

Relationship between Insomnia and Depression in Type 2 Diabetics (2형 당뇨병 환자에서 불면증과 우울 증상의 관련성)

  • Lee, Jin Hwan;Cheon, Jin Sook;Choi, Young Sik;Kim, Ho Chan;Oh, Byoung Hoon
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.27 no.1
    • /
    • pp.50-59
    • /
    • 2019
  • Objectives : Many of the patients with type 2 diabetes are associated with sleep problems, and the rate of insomnia is known to be higher in the general population. The aims of this study were to know the frequency and clnical characteristics of insomnia, and related variables to insomnia in patients diagnosed with type 2 diabetes. Methods : For 99 patients from 18 to 80 years of age (65 males and 34 females) with type 2 diabetes, interviews were performed. Total sleep time and sleep latency was evaluated. Insomnia was evaluated using the Korean Version of the Insomnia Severity Index (ISI-K). Severity of depressive symptoms were evaluted using the Korean version of the Hamilton Depression Scale (K-HDRM). According to the cutoff score of 15.5 on the ISI-K, subjects were divided into the group of type 2 diabetics with insomnia (N=34) and those without insomnia (N=65) at first, and then statistically analyzed. Results : TInsomnia could be found in 34.34% of type 2 diabetics. Type 2 diabetics with insomnia had significantly more single or divorced (respectively 11.8%, p<0.05), higher total scores of the K-HDRS ($11.76{\pm}5.52$, p<0.001), shorter total sleep time ($5.35{\pm}2.00hours$, p<0.001), and longer sleep latency ($50.29{\pm}33.80minutes$, p<0.001). The all item scores of the ISI-K in type 2 diabetics with insomnia were significantly higher than those in type 2 diabetics without insomnia, that is, total ($18.38{\pm}2.69$), A1 (Initial insomnia) ($2.97{\pm}0.76$), A2 (Middle insomnia) ($3.06{\pm}0.69$), A3 (Terminal insomnia) ($2.76{\pm}0.61$), B (Satisfaction) ($3.18{\pm}0.72$), C (Interference) ($2.09{\pm}0.97$), D (Noticeability) ($2.12{\pm}1.09$) and E (Distress) ($2.21{\pm}0.81$) (respectively p<0.001). Variables associated with insomnia in type 2 diabetics were as following. Age had significant negative correlation with A3 items of the ISI-K (${\beta}=-0.241$, p<0.05). Total scores of the K-HDRS had significant positive correlation, while total sleep time had significant negative correlation with all items of the ISI-K (respectively p<0.05). Sleep latency had significant positive correlation with total,, A1, B and E item scores of the ISI-K (respectively p<0.05). Conclusions : Insomnia was found in about 1/3 of type 2 diabetics. According to the presence of insomnia, clinical characteristics including sleep quality as well as quantity seemed to be different. Because depression seemed to be correlated with insomnia, clinicians should pay attention to early detection and intervention of depression among type 2 diabetics.

The Application of 3D Bolus with Neck in the Treatment of Hypopharynx Cancer in VMAT (Hypopharynx Cancer의 VMAT 치료 시 Neck 3D Bolus 적용에 대한 유용성 평가)

  • An, Ye Chan;Kim, Jin Man;Kim, Chan Yang;Kim, Jong Sik;Park, Yong Chul
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.41-52
    • /
    • 2020
  • Purpose: To find out the dosimetric usefulness, setup reproducibility and efficiency of applying 3D Bolus by comparing two treatment plans in which Commercial Bolus and 3D Bolus produced by 3D Printing Technology were applied to the neck during VMAT treatment of Hypopahrynx Cancer to evaluate the clinical applicability. Materials and Methods: Based on the CT image of the RANDO phantom to which CB was applied, 3D Bolus were fabricated in the same form. 3D Bolus was printed with a polyurethane acrylate resin with a density of 1.2g/㎤ through the SLA technique using OMG SLA 660 Printer and MaterializeMagics software. Based on two CT images using CB and 3D Bolus, a treatment plan was established assuming VMAT treatment of Hypopharynx Cancer. CBCT images were obtained for each of the two established treatment plans 18 times, and the treatment efficiency was evaluated by measuring the setup time each time. Based on the obtained CBCT image, the adaptive plan was performed through Pinnacle, a computerized treatment planning system, to evaluate target, normal organ dose evaluation, and changes in bolus volume. Results: The setup time for each treatment plan was reduced by an average of 28 sec in the 3D Bolus treatment plan compared to the CB treatment plan. The Bolus Volume change during the pretreatment period was 86.1±2.70㎤ in 83.9㎤ of CB Initial Plan and 99.8±0.46㎤ in 92.2㎤ of 3D Bolus Initial Plan. The change in CTV Min Value was 167.4±19.38cGy in CB Initial Plan 191.6cGy and 149.5±18.27cGy in 3D Bolus Initial Plan 167.3cGy. The change in CTV Mean Value was 228.3±0.38cGy in CB Initial Plan 227.1cGy and 227.7±0.30cGy in 3D Bolus Initial Plan 225.9cGy. The change in PTV Min Value was 74.9±19.47cGy in CB Initial Plan 128.5cGy and 83.2±12.92cGy in 3D Bolus Initial Plan 139.9cGy. The change in PTV Mean Value was 226.2±0.83cGy in CB Initial Plan 225.4cGy and 225.8±0.33cGy in 3D Bolus Initial Plan 224.1cGy. The maximum value for the normal organ spinal cord was the same as 135.6cGy on average each time. Conclusion: From the experimental results of this paper, it was found that the application of 3D Bolus to the irregular body surface is more dosimetrically useful than the application of Commercial Bolus, and the setup reproducibility and efficiency are excellent. If further case studies along with research on the diversity of 3D printing materials are conducted in the future, the application of 3D Bolus in the field of radiation therapy is expected to proceed more actively.

Comparative analysis of Glomerular Filtration Rate measurement and estimated glomerular filtration rate using 99mTc-DTPA in kidney transplant donors. (신장이식 공여자에서 99mTc-DTPA를 이용한 Glomerular Filtration Rate 측정과 추정사구체여과율의 비교분석)

  • Cheon, Jun Hong;Yoo, Nam Ho;Lee, Sun Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.35-40
    • /
    • 2021
  • Purpose Glomerular filtration rate(GFR) is an important indicator for the diagnosis, treatment, and follow-up of kidney disease and is also used by healthy individuals for drug use and evaluating kidney function in donors. The gold standard method of the GFR test is to measure by continuously injecting the inulin which is extrinsic marker, but it takes a long time and the test method is complicated. so, the method of measuring the serum concentration of creatinine is used. Estimated glomerular filtration rate (eGFR) is used instead. However, creatinine is known to be affected by age, gender, muscle mass, etc. eGFR formulas that are currently used include the Cockroft-Gault formula, the modification of diet in renal disease (MDRD) formula, and the chronic kidney disease epidemilogy collaboration (CKD-EPI) formula for adults. For children, the Schwartz formula is used. Measurement of GFR using 51Cr-EDTA (diethylenetriamine tetraacetic acid), 99mTc-DTPA (diethylenetriamine pentaacetic acid) can replace inulin and is currently in use. Therefore, We compared the GFR measured using 99mTc-DTPA with the eGFR using CKD-EPI formula. Materials and Methods For 200 kidney transplant donors who visited Asan medical center.(96 males, 104 females, 47.3 years ± 12.7 years old) GFR was measured using plasma(Two-plasma-sample-method, TPSM) obtained by intravenous administration of 99mTc-DTPA(0.5mCi, 18.5 MBq). eGFR was derived using CKD-EPI formula based on serum creatinine concentration. Results GFR average measured using 99mTc-DTPA for 200 kidney transplant donors is 97.27±19.46(ml/min/1.73m2), and the eGFR average value using the CKD-EPI formula is 96.84±17.74(ml/min/1.73m2), The concentration of serum creatinine is 0.84±0.39(mg/dL). Regression formula of 99mTc-DTPA GFR for serum creatinine-based eGFR was Y = 0.5073X + 48.186, and the correlation coefficient was 0.698 (P<0.01). Difference (%) was 1.52±18.28. Conclusion The correlation coefficient between the 99mTc-DTPA and the eGFR derived on serum creatinine concentration was confirmed to be moderate. This is estimated that eGFR is affected by external factors such as age, gender, and muscle mass and use of formulas made for kidney disease patients. By using 99mTc-DTPA, we can provide reliable GFR results, which is used for diagnosis, treatment and observation of kidney disease, and kidney evaluation of kidney transplant patients.

A study of the plan dosimetic evaluation on the rectal cancer treatment (직장암 치료 시 치료계획에 따른 선량평가 연구)

  • Jeong, Hyun Hak;An, Beom Seok;Kim, Dae Il;Lee, Yang Hoon;Lee, Je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.171-178
    • /
    • 2016
  • Purpose : In order to minimize the dose of femoral head as an appropriate treatment plan for rectal cancer radiation therapy, we compare and evaluate the usefulness of 3-field 3D conformal radiation therapy(below 3fCRT), which is a universal treatment method, and 5-field 3D conformal radiation therapy(below 5fCRT), and Volumetric Modulated Arc Therapy (VMAT). Materials and Methods : The 10 cases of rectal cancer that treated with 21EX were enrolled. Those cases were planned by Eclipse(Ver. 10.0.42, Varian, USA), PRO3(Progressive Resolution Optimizer 10.0.28) and AAA(Anisotropic Analytic Algorithm Ver. 10.0.28). 3fCRT and 5fCRT plan has $0^{\circ}$, $270^{\circ}$, $90^{\circ}$ and $0^{\circ}$, $95^{\circ}$, $45^{\circ}$, $315^{\circ}$, $265^{\circ}$ gantry angle, respectively. VMAT plan parameters consisted of 15MV coplanar $360^{\circ}$ 1 arac. Treatment prescription was employed delivering 54Gy to recum in 30 fractions. To minimize the dose difference that shows up randomly on optimizing, VMAT plans were optimized and calculated twice, and normalized to the target V100%=95%. The indexes of evaluation are D of Both femoral head and aceta fossa, total MU, H.I.(Homogeneity index) and C.I.(Conformity index) of the PTV. All VMAT plans were verified by gamma test with portal dosimetry using EPID. Results : D of Rt. femoral head was 53.08 Gy, 50.27 Gy, and 30.92 Gy, respectively, in the order of 3fCRT, 5fCRT, and VMAT treatment plan. Likewise, Lt. Femoral head showed average 53.68 Gy, 51.01 Gy and 29.23 Gy in the same order. D of Rt. aceta fossa was 54.86 Gy, 52.40 Gy, 30.37 Gy, respectively, in the order of 3fCRT, 5fCRT, and VMAT treatment plan. Likewise, Lt. Femoral head showed average 53.68 Gy, 51.01 Gy and 29.23 Gy in the same order. The maximum dose of both femoral head and aceta fossa was higher in the order of 3fCRT, 5fCRT, and VMAT treatment plan. C.I. showed the lowest VMAT treatment plan with an average of 1.64, 1.48, and 0.99 in the order of 3fCRT, 5fCRT, and VMAT treatment plan. There was no significant difference on H.I. of the PTV among three plans. Total MU showed that the VMAT treatment plan used 124.4MU and 299MU more than the 3fCRT and 5fCRT treatment plan, respectively. IMRT verification gamma test results for the VMAT plan passed over 90.0% at 2mm/2%. Conclusion : In rectal cancer treatment, the VMAT plan was shown to be advantageous in most of the evaluation indexes compared to the 3D plan, and the dose of the femoral head was greatly reduced. However, because of practical limitations there may be a case where it is difficult to select a VMAT treatment plan. 5fCRT has the advantage of reducing the dose of the femoral head as compared to the existing 3fCRT, without regard to additional problems. Therefore, not only would it extend survival time but the quality of life in general, if hospitals improved radiation therapy efficiency by selecting the treatment plan in accordance with the hospital's situation.

  • PDF

The Patterns of Change in Arterial Oxygen Saturation and Heart Rate and Their Related Factors during Voluntary Breath holding and Rebreathing (자발적 호흡정지 및 재개시 동맥혈 산소포화도와 심박수의 변동양상과 이에 영향을 미치는 인자)

  • Lim, Chae-Man;Kim, Woo-Sung;Choi, Kang-Hyun;Koh, Youn-Suck;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.4
    • /
    • pp.379-388
    • /
    • 1994
  • Background : In sleep apnea syndrome, arterial oxygen saturation($SaO_2$) decreases at a variable rate and to a variable degree for a given apneic period from patient to patient, and various kinds of cardiac arrythmia are known to occur. Factors supposed to affect arterial oxygen desaturation during apnea are duration of apnea, lung voulume at which apnea occurs, and oxygen consumption rate of the subject. The lung serves as preferential oxygen source during apnea, and there have been many reports related with the influence of lung volume on $SaO_2$ during apnea, but there are few, if any, studies about the influence of oxygen consumption rate of an individual on $SaO_2$ during breath holding or about the profile of arterial oxygen resaturation after breathing resumed. Methods : To investigate the changes of $SaO_2$ and heart rate(HR) during breath holding(BH) and rebreathing(RB) and to evaluate the physiologic factors responsible for the changes, lung volume measurements, and arterial blood gas analyses were performed in 17 healthy subjects. Nasal airflow by thermistor, $SaO_2$ by pulse oxymeter and ECG tracing were recorded on Polygraph(TA 4000, Gould, U.S.A.) during voluntary BH & RB at total lung capacity(TLC), at functional residual capacity(FRC) and at residual volume(RV), respectively, for the study subjects. Each subject's basal metabolic rate(BMR) was assumed on Harris-Benedict equation. Results: The time needed for $SaO_2$ to drop 2% from the basal level during breath holding(T2%) were $70.1{\pm}14.2$ sec(mean${\pm}$standard deviation) at TLC, $44.0{\pm}11.6$ sec at FRC, and $33.2{\pm}11.1$ sec at RV(TLC vs. FRC, p<0.05; FRC vs. RV, p<0.05). On rebreathing after $SaO_2$ decreased 2%, further decrement in $SaO_2$ was observed and it was significantly greater at RV($4.3{\pm}2.1%$) than at TLC($1.4{\pm}1.0%$)(p<0.05) or at FRC($1.9{\pm}1.4%$)(p<0.05). The time required for $SaO_2$ to return to the basal level after RB(Tr) at TLC was not significantly different from those at FRC or at RV. T2% had no significant correlation either with lung volumes or with BMR respectively. On the other hand, T2% had significant correlation with TLC/BMR(r=0.693, p<0.01) and FRC/BMR (r=0.615, p<0.025) but not with RV/BMR(r=0.227, p>0.05). The differences between maximal and minimal HR(${\Delta}HR$) during the BH-RB manuever were $27.5{\pm}9.2/min$ at TLC, $26.4{\pm}14.0/min$ at RV, and $19.1{\pm}6.0/min$ at FRC which was significantly smaller than those at TLC(p<0.05) or at RV(p<0.05). The mean difference of 5 p-p intervals before and after RB were $0.8{\pm}0.10$ sec and $0.72{\pm}0.09$ sec at TLC(p<0.001), $0.82{\pm}0.11$ sec and $0.73{\pm}0.09$ sec at FRC(p<0.025), and $0.77{\pm}0.09$ sec and $0.72{\pm}0.09$ sec at RV(p<0.05). Conclusion Healthy subjects showed arterial desaturation of various rates and extent during breath holding at different lung volumes. When breath held at lung volume greater than FRC, the rate of arterial desaturation significantly correlated with lung volume/basal metabolic rate, but when breath held at RV, the rate of arterial desaturation did not correlate linearly with RV/BMR. Sinus arrythmias occurred during breath holding and rebreathing manuever irrespective of the size of the lung volume at which breath holding started, and the amount of change was smallest when breath held at FRC and the change in vagal tone induced by alteration in respiratory movement might be the major responsible factor for the sinus arrythmia.

  • PDF

Results of Preoperative Concurrent Chemoradiotherapy for the Treatment of Rectal Cancer (직장암의 수술 전 동시적 항암화학방사선치료 결과)

  • Yoon, Mee-Sun;Nam, Taek-Keun;Kim, Hyeong-Rok;Nah, Byung-Sik;Chung, Woong-Ki;Kim, Young-Jin;Ahn, Sung-Ja;Song, Ju-Young;Jeong, Jae-Uk
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.247-256
    • /
    • 2008
  • Purpose: The purpose of this study is to evaluate anal sphincter preservation rates, survival rates, and prognostic factors in patients with rectal cancer treated with preoperative chemoradiotherapy. Materials and Methods: One hundred fifty patients with pathologic confirmed rectal cancer and treated by preoperative chemoradiotherapy between January 1999 and June 2007. Of the 150 patients, the 82 who completed the scheduled chemoradiotherapy, received definitive surgery at our hospital, and did not have distant metastasis upon initial diagnosis were enrolled in this study. The radiation dose delivered to the whole pelvis ranged from 41.4 to 46.0 Gy (median 44.0 Gy) using daily fractions of $1.8{\sim}2.0\;Gy$ at 5 days per week and a boost dose to the primary tumor and high risk area up to a total of $43.2{\sim}54\;Gy$ (median 50.4 Gy). Sixty patients (80.5%) received 5-fluorouracil, leucovorin, and cisplatin, while 16 patients (19.5%) were administered 5-fluorouracil and leucovorin every 4 weeks concurrently during radiotherapy. Surgery was performed for 3 to 45 weeks (median 7 weeks) after completion of chemoradiotherapy. Results: The sphincter preservation rates for all patients were 73.2% (60/82). Of the 48 patients whose tumor was located at less than 5 cm away from the anal verge, 31 (64.6%) underwent sphincter-saving surgery. Moreover, of the 34 patients whose tumor was located at greater than or equal to 5 cm away from the anal verge, 29 (85.3%) were able to preserve their anal sphincter. A pathologic complete response was achieved in 14.6% (12/82) of all patients. The downstaging rates were 42.7% (35/82) for the T stage, 75.5% (37/49) for the N stage, and 67.1% (55/82) for the overall stages. The median follow-up period was 38 months (range $11{\sim}107$ months). The overall 5-year survival, disease-free survival, and locoregional control rates were 67.4%, 58.9% and 84.4%, respectively. The 5-year overall survival rates based on the pathologic stage were 100% for stage 0 (n=12), 59.1% for stage I (n=16), 78.6% for stage II (n=30), 36.9% for stage III (n=23), and one patient with pathologic stage IV was alive for 43 months (p=0.02). The 5-year disease-free survival rates were 77.8% for stage 0, 63.6% for stage I, 58.9% for stage II, 51.1% for stage III, and 0% for stage IV (p<0.001). The 5-year locoregional control rates were 88.9% for stage 0, 93.8% for stage I, 91.1% for stage II, 68.2% for stage III, and one patient with pathologic stage IV was alive without local recurrence (p=0.01). The results of a multivariate analysis with age (${\leq}55$ vs. >55), clinical stage (I+II vs. III), radiotherapy to surgery interval (${\leq}6$ weeks vs. >6 weeks), operation type (sphincter preservation vs. no preservation), pathologic T stage, pathologic N stage, pathologic overall stage (0 vs. I+II vs. III+IV), and pathologic response (complete vs. non-CR), only age and pathologic N stage were significant predictors of overall survival, pathologic overall stage for disease-free survival, and pathologic N stage for locoregional control rates, respectively. Recurrence was observed in 25 patients (local recurrence in 10 patients, distant metastasis in 13 patients, and both in 2 patients). Acute hematologic toxicity ($\geq$grade 3) during chemoradiotherapy was observed in 2 patients, while skin toxicity was observed in 1 patient. Complications developing within 60 days after surgery and required admission or surgical intervention, were observed in 11 patients: anastomotic leakage in 5 patients, pelvic abscess in 2 patients, and others in 4 patients. Conclusion: Preoperative chemoradiotherapy was an effective modality to achieve downstaging and sphincter preservation in rectal cancer cases with a relatively low toxicity. Pathologic N stage was a statistically significant prognostic factor for survival and locoregional control and so, more intensified postoperative adjuvant chemotherapy should be considered in these patients.

The Results of Definitive Radiation Therapy and The Analysis of Prognostic Factors for Non-Small Cell Lung Cancer (비소세포성 폐암에서 근치적 방사선치료 성적과 예후인자 분석)

  • Chang, Seung-Hee;Lee, Kyung-Ja;Lee, Soon-Nam
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.409-423
    • /
    • 1998
  • Purpose : This retrospective study was tried to evaluate the clinical characteristics of patients, patterns of failure, survival rates, prognostic factors affecting survival, and treatment related toxicities when non-small cell lung cancer patients was treated by definitive radiotherapy alone or combined with chemotherapy. Materials and Methods : We evaluated the treatment results of 70 patients who were treated by definitive radiation therapy for non-small cell lung cancer at the Department of Radiation Oncology, Ewha Womans University Hospital, between March 1982 and April 1996. The number of patients of each stage was 2 in stage I, 6 in stage II, 30 in stage III-A, 29 in stage III-B, 3 in stage IV. Radiation therapy was administered by 6 MV linear accelerator and daily dose was 1.8-2.0 Gy and total radiation dose was ranged from 50.4 Gy to 72.0 Gy with median dose 59.4 Gy. Thirty four patients was treated with combined therapy with neoadjuvant or concurrent chemotherapy and radiotherapy, and most of them were administered with the multi-drug combined chemotherapy including etoposide and cisplatin. The survival rate was calculated with the Kaplan-Meier methods. Results : The overall 1-year, 2-year, and 3-year survival rates were 63$\%$, 29$\%$, and 26$\%$, respectively. The median survival time of all patients was 17 months. The disease-free survival rate for 1-year and 2-year were 23$\%$ and 16$\%$, respectively. The overall 1-year survival rates according to the stage was 100$\%$ for stage I, 80$\%$ for stage II, 61$\%$ for stage III, and 50$\%$ for stage IV. The overall 1-year 2-year, and 3-year survival rates for stage III patients only were 61$\%$, 23$\%$, and 20$\%$, respectively. The median survival time of stage III patients only was 15 months. The complete response rates by radiation therapy was 10$\%$ and partial response rate was 50$\%$. Thirty patients (43$\%$) among 70 patients assessed local control at initial 3 months follow-up duration. Twenty four (80$\%$) of these 30 Patients was possible to evaluate the pattern of failure after achievement of local control. And then, treatment failure occured in 14 patients (58$\%$): local relapse in 6 patients (43$\%$), distant metastasis in 6 patients (43$\%$) and local relapse with distant metastasis in 2 patients (14$\%$). Therefore, 10 patients (23$\%$) were controlled of disease of primary site with or without distant metastases. Twenty three patients (46$\%$) among 50 patients who were possible to follow-up had distant metastasis. The overall 1-year survival rate according to the treatment modalities was 59$\%$ in radiotherapy alone and 66$\%$ in chemoirradiation group. The overall 1-year survival rates for stage III patients only was 51$\%$ in radiotherapy alone and 68$\%$ in chemoirradiation group which was significant different. The significant prognostic factors affecting survival rate were the stage and the achievement of local control for all patients at univariate- analysis. Use of neoadjuvant or concurrent chemotherapy, use of chemotherapy and the achievement of local control for stage III patients only were also prognostic factors. The stage, pretreatment performance status, use of neoadjuvant or concurrent chemotherapy, total radiation dose and the achievement of local control were significant at multivariate analysis. The treatment-related toxicities were esophagitis, radiation pneunonitis, hematologic toxicity and dermatitis, which were spontaneously improved, but 2 patients were died with radiation pneumonitis. Conclusion : The conventional radiation therapy was not sufficient therapy for achievement of long-term survival in locally advanced non-small cell lung cancer. Therefore, aggressive treatment including the addition of appropriate chemotherapeutic drug to decrease distant metastasis and preoperative radiotherapy combined with surgery, hyperfractionation radiotherapy or 3-D conformal radiation therapy for increase local control are needed.

  • PDF

Evaluation of the Usefulness of MapPHAN for the Verification of Volumetric Modulated Arc Therapy Planning (용적세기조절회전치료 치료계획 확인에 사용되는 MapPHAN의 유용성 평가)

  • Woo, Heon;Park, Jang Pil;Min, Jae Soon;Lee, Jae Hee;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.115-121
    • /
    • 2013
  • Purpose: Latest linear accelerator and the introduction of new measurement equipment to the agency that the introduction of this equipment in the future, by analyzing the process of confirming the usefulness of the preparation process for applying it in the clinical causes some problems, should be helpful. Materials and Methods: All measurements TrueBEAM STX (Varian, USA) was used, and a file specific to each energy, irradiation conditions, the dose distribution was calculated using a computerized treatment planning equipment (Eclipse ver 10.0.39, Varian, USA). Measuring performance and cause errors in MapCHECK 2 were analyzed and measured against. In order to verify the performance of the MapCHECK 2, 6X, 6X-FFF, 10X, 10X-FFF, 15X field size $10{\times}10$ cm, gantry $0^{\circ}$, $180^{\circ}$ direction was measured by the energy. IGRT couch of the CT values affect the measurements in order to confirm, CT number values : -800 (Carbon) & -950 (COUCH in the air), -100 & 6X-950 in the state for FFF, 15X of the energy field sizes $10{\times}10$, gantry $180^{\circ}$, $135^{\circ}$, $275^{\circ}$ directionwas measured at, MapPHAN allocated to confirm the value of HU were compared, using the treatment planning computer for, Measurement error problem by the sharp edges MapPHAN Learn gantry direction MapPHAN of dependence was measured in three ways. GANTRY $90^{\circ}$, $270^{\circ}$ in the direction of the vertically erected settings 6X-FFF, 15X respectively, and Setting the state established as a horizontal field sizes $10{\times}10$, $90^{\circ}$, $45^{\circ}$, $315^{\circ}$, $270^{\circ}$ of in the direction of the energy-6X-FFF, 15X, respectively, were measured. Without intensity modulated beam of the third open arc were investigated. Results: Of basic performance MapCHECK confirm the attenuation measured by Couch, measured from the measured HU values that are assigned to the MAP-PHAN, check for calculation accuracy for the angled edge of the MapPHAN all come in a range of valid measurement errors do not affect the could see. three ways for the Gantry direction dependence, the first of the meter built into the value of the Gantry $270^{\circ}$ (relative $0^{\circ}$), $90^{\circ}$ (relative $180^{\circ}$), 6X-FFF, 15X from each -1.51, 0.83% and -0.63, -0.22% was not affected by the AP/PA direction represented. Setting the meter horizontally Gantry $90^{\circ}$, $270^{\circ}$ from the couch, Energy 6X-FFF 4.37, 2.84%, 15X, -9.63, -13.32% the difference. By-side direction measurements MapPHAN in value is not within the valid range can not, because that could be confirmed as gamma pass rate 3% of the value is greater than the value shown. You can check the Open Arc 6X-FFF, 15X energy, field size $10{\times}10$ cm $360^{\circ}$ rotation of the dose distribution in the state to look at nearly 90% pass rate to emerge. Conclusion: Based on the above results, the MapPHAN gantry direction dependence by side in the direction of the beam relative dose distribution suitable for measuring the gamma value, but accurate measurement of the absolute dose can not be considered is. this paper, a more accurate treatment plan in order to confirm, Reduce the tolerance for VMAT, such as lateral rotation investigation in order to measure accurate absolute isodose using a combination of IMF (Isocentric Mounting Fixture) MapCHEK 2, will be able to minimize the impact due to the angular dependence.

  • PDF

The Effect of Pressure Support on Respiratory Mechanics in CPAP and SIMV (CPAP 및 SIMV Mode하에서 Pressure Support 사용이 호흡역학에 미치는 효과)

  • Lim, Chae-Man;Jang, Jae-Won;Choi, Kang-Hyun;Lee, Sang-Do;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Park, Pyung-Whan;Choi, Jong-Moo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.3
    • /
    • pp.351-360
    • /
    • 1995
  • Background: Pressure support(PS) is becomimg a widely accepted method of mechanical ventilation either for total unloading or for partial unloading of respiratory muscle. The aim of the study was to find out if PS exert different effects on respiratory mechanics in synchronized intermittent mandatory ventilation(SIMV) and continuous positive airway pressure (CPAP) modes. Methods: 5, 10 and 15 cm $H_2O$ of PS were sequentially applied in 14 patients($69{\pm}12$ yrs, M:F=9:5) and respiratory rate (RR), tidal volume($V_T$), work of breathing(WOB), pressure time product(PTP), $P_{0.1}$, and $T_1/T_{TOT}$ were measured using the CP-100 pulmonary monitor(Bicore, USA) in SIMV and CPAP modes respectively. Results: 1) Common effects of PS on respiratory mechanics in both CPAP and SIMV modes As the level of PS was increased(0, 5, 10, 15 cm $H_2O$), $V_T$ was increased in CPAP mode($0.28{\pm}0.09$, $0.29{\pm}0.09$, $0.31{\pm}0.11$, $0.34{\pm}0.12\;L$, respectively, p=0.001), and also in SIMV mode($0.31{\pm}0.15$, $0.32{\pm}0.09$, $0.34{\pm}0.16$, $0.36{\pm}0.15\;L$, respectively, p=0.0215). WOB was decreased in CPAP mode($1.40{\pm}1.02$, $1.01{\pm}0.80$, $0.80{\pm}0.85$, $0.68{\pm}0.76$ joule/L, respectively, p=0.0001), and in SIMV mode($0.97{\pm}0.77$, $0.76{\pm}0.64$, $0.57{\pm}0.55$, $0.49{\pm}0.49$ joule/L, respectively, p=0.0001). PTP was also decreased in CPAP mode($300{\pm}216$, $217{\pm}165$, $179{\pm}187$, $122{\pm}114cm$ $H_2O{\cdot}sec/min$, respectively, p=0.0001), and in SIMV mode($218{\pm}181$, $178{\pm}157$, $130{\pm}147$, $108{\pm}129cm$ $H_2O{\cdot}sec/min$, respectively, p=0.0017). 2) Different effects of PS on respiratory mechanics in CP AP and SIMV modes By application of PS (0, 5, 10, 15 cm $H_2O$), RR was not changed in CPAP mode($27.9{\pm}6.7$, $30.0{\pm}6.6$, $26.1{\pm}9.1$, $27.5{\pm}5.7/min$, respectively, p=0.505), but it was decreased in SIMV mode ($27.4{\pm}5.1$, $27.8{\pm}6.5$, $27.6{\pm}6.2$, $25.1{\pm}5.4/min$, respectively, p=0.0001). $P_{0.1}$ was reduced in CPAP mode($6.2{\pm}3.5$, $4.8{\pm}2.8$, $4.8{\pm}3.8$, $3.9{\pm}2.5\;cm$ $H_2O$, respectively, p=0.0061), but not in SIMV mode($4.3{\pm}2.1$, $4.0{\pm}1.8$, $3.5{\pm}1.6$, $3.5{\pm}1.9\;cm$ $H_2O$, respectively, p=0.054). $T_1/T_{TOT}$ was decreased in CPAP mode($0.40{\pm}0.05$, $0.39{\pm}0.04$, $0.37{\pm}0.04$, $0.35{\pm}0.04$, respectively, p=0.0004), but not in SIMV mode($0.40{\pm}0.08$, $0.35{\pm}0.07$, $0.38{\pm}0.10$, $0.37{\pm}0.10$, respectively, p=0.287). 3) Comparison of respiratory mechanics between CPAP+PS and SIMV alone at same tidal volume. The tidal volume in CPAP+PS 10 cm $H_2O$ was comparable to that of SIMV alone. Under this condition, the RR($26.1{\pm}9.1$, $27.4{\pm}5.1/min$, respectively, p=0.516), WOB($0.80{\pm}0.85$, 0.97+0.77 joule/L, respectively, p=0.485), $P_{0.1}$($3.9{\pm}2.5$, $4.3{\pm}2.1\;cm$ $H_2O$, respectively, p=0.481) were not different between the two methods, but PTP($179{\pm}187$, $218{\pm}181 cmH_2O{\cdot}sec/min$, respectively, p=0.042) and $T_1/T_{TOT}$($0.37{\pm}0.04$, $0.40{\pm}0.08$, respectively, p=0.026) were significantly lower in CPAP+PS than in SIMV alone. Conclusion: PS up to 15 cm $H_2O$ increased tidal volume, decreased work of breathing and pressure time product in both SIMV and CPAP modes. PS decreased respiration rate in SIMV mode but not in CPAP mode, while it reduced central respiratory drive($P_{0.1}$) and shortened duty cycle ($T_1/T_{TOT}$) in CPAP mode but not in SIMV mode. By 10 em $H_2O$ of PS in CPAP mode, same tidal volume was obtained as in SIMV mode, and both methods were comparable in respect to RR, WOB, $P_{0.1}$, but CPAP+PS was superior in respect to the efficiency of the respiratory muscle work (PTP) and duty cycle($T_1/T_{TOT}$).

  • PDF