• Title/Summary/Keyword: 임계 균열 깊이

Search Result 5, Processing Time 0.024 seconds

Effect of Micro-Cracks on Chloride Ions Penetration of Concrete II: Examination of Critical Crack Width (미세균열이 콘크리트의 염소이온 침투에 미치는영향 II: 임계 균열폭의 고찰)

  • Yoon, In-Seok
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.6
    • /
    • pp.707-715
    • /
    • 2007
  • The vulnerability of concrete to its environment is significantly dependent on the fact that concrete is a porous material. For well-consolidated and well-cured concrete, its service life is a very long and an entrance of aggressive substance might be only pores. However, for cracked concrete, cracks should be preferential channel for the penetration of aggressive substance such as chloride ions. The effect of crack on chloride penetration depends on its size for example, crack width and crack depth. The purpose of this study is examining the effect of crack width and crack depth on chloride penetration. In order to visualize chloride penetration via cracks, RCM (rapid chloride migration) testing is accomplished. Crack width is examined using an optical microscope and CMOD value is used to estimate average crack width. From the examination on the trend of chloride diffusion coefficients of concrete specimens with various crack widths, a critical crack width and a critical crack depth are found out.

Effect of Micro-Cracks on Chloride Ions Penetration of Concrete: Phonomenological Model (미세균열이 콘크리트의 염소이온 침투에 미치는 영향: 현상학적 모델)

  • Yoon, In-Seok
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.1
    • /
    • pp.57-65
    • /
    • 2007
  • Over the past few decades, considerable numbers of studies on the durability of concrete have been carried out extensively. A lot of improvements have been achieved especially in both measuring techniques as well as modeling of ionic flows. However, the majority of these researches have been performed on sound uncracked concrete, although most of in-situ concrete structures have more or less micro-cracks. It is only recent approach that the attention has shifted towards the influence of cracks and crack width on the penetration of chloride into concrete. The penetration of chlorides into concrete through the cracks can make a significant harmful effect on reinforcement corrosion. On the other hand, a general acceptable crack width of 0.3 mm has been recognized for keeping the serviceability of concrete structures in accordance with a lot of codes. However, there seems to be rare established description to explain the critical crack width in terms of the durability of concrete. To make a bad situation worse, there is little agreement on critical crack width among a few of literatures for this issue. Critical crack width is still controversial problem. Nevertheless, since the critical crack width is important key for healthy assessment of concrete structures exposed to marine environment, it should be established. The objective of this study is to define a critical crack width. The critical crack width in this study is designed for a threshold crack width, which contributes to the first variation of chloride diffusion coefficient in responsive to the existence of cracks. A simple solution is formulated to realize the quantifiable parameter, chloride diffusion coefficient for only cracked zone excluding sound concrete. From the examination on the trend of chloride diffusion coefficient of only cracked zone for various crack widths, a critical crack width is founded out.

Critical Angle Analysis of Elliptical Corner Cracks in Mechanical Joints by Weight Function Method and Finite Element Analysis (가중함수법과 유한요소해석에 의한 기계적 체결부에 존재하는 타원형 모서리균열의 임계 경사각 해석)

  • Heo, Sung-Pil;Yang, Won-Ho;Ko, Myung-Hoon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.4
    • /
    • pp.1-9
    • /
    • 2002
  • There is the high possibility of crack initiation from mechanical joints, which are widely used in aircraft fuselages, due to the development of stress concentration and contact pressure. In this paper, the mixed-mode stress intensity factors at the surface and deepest points of an inclined quarter elliptical corner crack in mechanical joints are analyzed by the weight function method. The coefficients included in the weight function are obtained by finite element analyses for reference loadings. Critical angle at which mode I stress intensity factor becomes maximum is determined by analyzing the variation of stress intensity factors along incline angle of crack and the effects of the amount of clearance and crack depth on the critical angle are investigated.

A Study on Fracture Bahavior of Composite Material Subjected to Simultaneous Deformation Mode (연립변형모드 구성된 복합재료의 파괴역학적 거동에 관한 연구)

  • 김상철
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.3
    • /
    • pp.179-187
    • /
    • 1997
  • 콘크리트는 여러 구성 성분들이 불규칙적인 배열을 이루어 형성된 복합재료이지만, 과거에는 이 재료를 하나의 단종재료로 간주하여 해석하였기 때문에, LEFM에서 사용되는 파괴인성계수만으로는 콘크리트의 파괴역학적 접근이 어렵다는 것 이외에는 파괴인성계수들의 크기의존성에 대한 이유라든가, 실험을 통해서 관측된 구조물 두께 방향으로의 서로 다른 깊이의 균열 진행 현상에 대해서는 설명하기가 어려웠다. 따라서 본 연구는 콘크리트를 하나의 복합재료로써 각각의 구성요소들이 차지하고 있는 체적비 및 배열상의 효과를 고려하여 복합재료의 파괴거동을 해석하고, 구성재료의 수와 파괴인성계수와의 상관관계를 분석하였다. 각각의 구성요소들을 연립변형모드( SD mode)로 배열시킨 조건에서 복합재료역학개념에 입각하여 해석한 결과, 일반적으로 실험이나 비선형파괴역학 해석과 같이 하중-변위곡선 상단부에서 비선형 거동이 관측되었다. 또한 임계응력확대계수( $K_IC$)나 파괴에너지($G_r$)는 구성원의 수나 보의 크기에 대해서 거의 무관한 값을 나타내지만, 임계군열선단개구변위 ($CTOD_c$)는 크기에 영향을 받음을 보여 주었다. 균열의 진행속도는 균열이 진행될수록 감소하며, 파괴인성이 작은 구성원에서부터 균열이 발생되어 결과적으로 보의 두께 방향으로 서로 다른 크기의 균열길이가 생성됨이 관측되었다.

Evaluation of Canister Weld Flaw Depth for Concrete Storage Cask (콘크리트 저장용기의 캐니스터 용접부 결함깊이 평가)

  • Moon, Tae-Chul;Cho, Chun-Hyung;Jung, Sung-Hun;Lee, Young-Oh;Jung, In-su
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.1
    • /
    • pp.91-99
    • /
    • 2017
  • Domestically developed concrete storage casks include an internal canister to maintain the confinement integrity of radio-active materials. In this study, we analyzed the depth of flaws caused by loads that propagate canister weld cracks under normal, off-normal and accident conditions, and evaluated the maximum allowable weld flaw depth needed to secure the structural integrity of the canister weld and to reduce the welding time of the internal canister lid of the concrete storage cask. Structural analyses for normal, off-normal and accident conditions were performed using the general-purpose finite element analysis program ABAQUS; the allowable flaw depth was assessed according to ASME B&PV Code Section XI. Evaluation results revealed an allowable canister weld flaw depth of 18.75 mm for the concrete storage cask, which satisfies the critical flaw depth recommended in NUREG-1536.