• Title/Summary/Keyword: 일체형

Search Result 1,155, Processing Time 0.026 seconds

A Study on a Curriculum Based on the Demands of the Industry (산업체 수요지향적 교과과정에 대한 연구)

  • Song, Eun-Jee
    • The Journal of Korean Institute for Practical Engineering Education
    • /
    • v.3 no.1
    • /
    • pp.136-142
    • /
    • 2011
  • As the competition among college graduates in the job market keeps getting intense, the educators' role of preparing students to get well adapted to the job environments should be more emphasized. However, in reality, many firms admit that many entry-level employees out of college need to be reeducated in a variety of areas. To resolve this problem, the current paper aims to propose some suggestions for a better school curriculum that reflects the needs and demands of the industry. The present proposal is based on my empirical knowledge from the department of computer science of the college where I am teaching and can be applied to other colleges. The suggestions for restructuring of a curriculum are expected to help students actively deal with the trend of developing technology. This restructured curriculum should help colleges produce workers with a good balance of academy and industry who can be assigned to work without being reeducated in the field.

  • PDF

A Study on the design and fabrication of Pluggable Lens for Optical PCB Interconnection (광 PCB 접속용 플러거블 렌즈의 설계 및 제작 연구)

  • Kim, Jung Hoon;Lee, Tae Ho;Kim, Dong Min;Jeong, Myung Yung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.1
    • /
    • pp.25-29
    • /
    • 2014
  • In this study, an optical PCB was proposed which can overcome the limitations of the conventional PCB, and a new structure with pluggable lens was considered for a high-efficient passive alignment. The structure was a lens-added optical waveguide for the improvement of misalignment between the lens and the waveguide in the alignment. Also, as it had a barrier-type structure to prevent the surface damage of the lens by desorption, the high-efficient passive alignment can be realized. The structure was designed by optimizing the simulation and the fabrication process of the pluggable lens structure was conducted using the repetitive photolithography and the thermal reflow. The optical waveguide with the lens-integrated pluggable interconnection was fabricated by the imprint process using the polydimethylsiloxane(PDMS) replica mold. Therefore, we confirmed the possibility of pluggable lens-added optical waveguide structure fabrication for high-efficient passive alignment.

A Study on the Performance Comparisons of Air Type BIPVT Collector Applied on Roofs and Facades (건물 적용 유형별 공기식 BIPVT 유닛의 전기 및 열성능 비교에 관한 연구)

  • Kang, Jun-Gu;Kim, Jin-Hee;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.5
    • /
    • pp.56-62
    • /
    • 2010
  • The integration of PV modules into building facades or roof could raise their temperature that results in the reduction of PV system's electrical power generation. Hot air can be extracted from the space between PV modules and building envelope, and used for heating in buildings. PV/thermal collectors, or more generally known as PVT collectors, are devices that operate simultaneously to convert solar energy from the sun into two other useful energies, namely, electricity and heat. This paper compares the experimental performance of BIPVT((Building-Integrated Photovoltaic Thermal) collectors that applied on building roof and facade. There are four different cases: a roof-integrated PVT type and a facade-integrated PVT type, the base models with an air gap between the PV module and the surface, and the improved models for each types with aluminum fins attached to the PV modules. The accumulated thermal energy of the roof-integrated type was 15.8% higher than the facade-integrated regardless of fin attachment. The accumulated electrical energy of the roof-integrated type was 7.6% higher, compared to that of the facade-integrated. The efficiency differences among the collectors may be due to the fact that the pins absorbed heat from the PV module and emitted it to air layer.

Evaluation of Electricity Generation According to Installation Type of Photovoltaic System in Residential Buildings (주거용 건물 태양광발전시스템의 설치유형에 따른 발전성능 평가)

  • Kim, Deok-Sung;Kim, Beob-Jeon;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.2
    • /
    • pp.35-45
    • /
    • 2017
  • The types of installation of the photovoltaic system applied to domestic residential buildings are classified as follows: Mounted modules with air circulation, semi-integrated modules with air duct behind, integrated modules with fully insulated back. In order to study generation characteristics of PV system, we verified the validity of interpretation program based on long-term measurement data of demonstration house installed in BAPV form and also analyzed the generation characteristics and performance of each installation type. The results are as follows. First, the RMSE of amount of generation and simulation according to annual daily insolation of demonstration system located in Daejeon was 0.98kWh and the range of relative error of monthly power generation was -5.8 to 3.1. Second, the average annual PR of mounted modules was 82%, semi-integrated modules 76.1% and integrated modules 71.9%. This differences were attributed to temperature loss. Third, the range of operating temperature of annual hourly photovoltaic modules was -6.5 to $61.0^{\circ}C$ for mounted modules, $-6.0{\sim}73.9^{\circ}C$ for semi-integrated modules and -5.5 to $88.9^{\circ}C$ for integrated modules. The temperature loss of each installation type was -14.0 to 16.1%, -13.8 to 21.9%, and -13.6 to 28.5%, respectively.

Analysis of Quench Generation in Fault Types According to Inductance Variation in Integrated Three-Phase Flux-Lock Type Superconducting Fault Current Limiting (삼상일체화된 자속구속형 고온초전도 전류제한기의 인덕턴스 변화에 따른 사고유형별 퀜치발생 분석)

  • Park, Chung-Ryul;Lim, Sung-Hun;Park, Hyoung-Min;Cho, Yong-Sun;Choi, Hyo-Sang;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.165-166
    • /
    • 2005
  • In this paper, we investigated the quench generation of HTSC elements in fault types according to inductance variation in the integrated three-phase flux-lock type SFCL. The integrated three-phase flux-lock type SFCL was the upgrade version of the single-phase flux-lock type SFCL. The structure of the integrated three-phase flux-lock type SFCL consisted of three-phase flux-lock reactor wound on an iron core with the ratio of the same turn between coil 1 and coil 2 in each phase. When the SFCL is operated under the normal condition, the flux generated in the iron core is zero because the flux generated between two coils of each single phase is canceled out. Therefore, the SFCL's impedance is zero, and the SFCL has negligible influence on the power system. However, if a fault occurs in any single-phase among three phases, the flux generated in the iron core is not zero any more. The flux makes HTSC elements of all phases quench irrespective of the fault type, which reduces the current of fault phase as well as the current of sound phase. It was observed that the fault current limiting characteristics of the suggested SFCL were dependent on the quench characteristics of HTSC elements in all three phases.

  • PDF

A Study on the Composite Behavior of Steel-Concrete with Slip Anchor (슬립앵커를 이용한 강-콘크리트 합성 거동 연구)

  • Won, Deok-Hee;Han, Taek-Hee;Kim, Seung-Jun;Han, Seung-Ryong;Kang, Young-Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.2 no.2
    • /
    • pp.7-12
    • /
    • 2011
  • Presently, composite method for steel and concrete is often used the stud. Steel properties of composite column could be changed by increasing of welding. The changed properties is possibly to cause local-buckling. Composite column had a large effect by slip instead of pull-out force in comparison composite girder. Improvement of adhesive force had effect by contact area rather than height of stud in composite column. This paper proposed new type of stud and analyzed performance through experimental study. This method would be effect steel structure with curvature.

Development and Performance Evaluation of the Shear Connector of Composite Beam with Vertical Bars (직봉의 기능을 포함한 합성보의 전단연결재 개발과 성능평가)

  • Kim, Sang-Seup;Park, Dong-Soo;Boo, Yoon-Seob
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.6
    • /
    • pp.725-736
    • /
    • 2011
  • In a composite beam, a shear connector is installed to resist the horizontal shear on an interface between steel beams and reinforced concrete slabs. The steel-wire-integrated deck plate slab is commonly used at the wide section beam. Then vertical bars are installed at the upper wire of the ends of the steel truss girder to ensure safety during the construction. The new type of shear connector is made of deformed bar and steel plates, and must function as vertical bars but must have higher shear capacity. This paper examines the ways to develop and utilize this new shear connector. From the push-out experiments, a shear connector made of a continuous deformed bar and steel plate showed a higher shear capacity and ductility than a ${\phi}16$ stud connector, and functioned as a vertical bar.

Flexible CIGS 태양전지

  • Jeong, Yong-Deok;Jo, Dae-Hyeong;Han, Won-Seok;Park, Rae-Man;Lee, Gyu-Seok;Kim, Je-Ha;O, Su-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.29-29
    • /
    • 2010
  • 건물일체형 태양전지 (BIPV; building integrated photovoltaics)나 야외 태양광 발전 차양 등의 태양광 발전에는 기존의 유리 기판 태양전지보다 가볍고 유연한 flexible 박막 태양전지가 설치하고 운영하는데 적합하다. 이러한 flexible 박막 태양전지는 자동차나 휴대기기의 전원이나 배터리의 충전기기로도 쓰이며 그 수요가 증가 추세에 있다. 특히, flexible Cu(In, Ga)$Se_2$(CIGS) 박막 태양전지는 기존의 flexible 실리콘 박막 태양전지보다 효율이 높아서 앞으로 성장 잠재력이 매우 높다. 세계적으로도 많은 기업이 상용화를 추진하고 있으며, 2007년부터 시장에 진입하고 있다. 그러나 현재의 flexible CIGS 박막 태양전지는 유리 기판 CIGS 박막 태양전지보다 효율이 낮고 패키지를 유리에서 플라스틱으로 대체하기 때문에 수명이 짧다. 또한, 아직도 완전한 양산 체제로 전환이 이루어지지 않았기 때문에 해결해야 할 문제점이 많이 있다. Flexible 기판으로는 스테인리스 스틸이나 폴리머 기판이 사용되는데, 유리 기판에 비해 저가 태양전지를 제조할 수 있을 뿐만 아니라 roll-to-roll 공정을 적용할 수 있어 가격 경쟁력을 확보할 수 있다. 특히, 금속 유연기판을 사용할 경우, 유리 기판에 비해 상대적으로 고온 공정이 가능한 장점이 있다. 그러나, 금속 기판을 사용할 경우 해결해야 할 두 가지 이슈가 있다. 첫째, CIGS 흡수층 형성에 도움을 주는 Na의 공급 문제이다. 유리 기판의 경우 기판에 포함되어 있는 Na이 확산을 통해 공급되지만, 금속 기판의 경우 별도의 Na 공급 방법을 고려해야 한다. 둘째, 불순물 확산 방지막 및 전기 절연층으로 사용되는 유전체 박막의 문제이다. 현재 다양한 금속 산화물 유전체 박막을 사용한 연구가 진행되고 있다. 본 논문에서는 flexible CIGS 박막 태양전지의 기술적 이슈 및 현재 연구 현황을 살펴보고, 스테인리스 스틸 기판을 이용한 CIGS 박막 태양전지에서 유전체 확산 방지막에 따른 특성을 비교하고자 한다. 스테인리스 스틸 기판의 불순물로부터의 확산을 방지하기 위하여 두 종류(intrinsic ZnO와 SiOx)의 유전체 박막을 각각 Na가 도핑된 Mo층과 스테인리스 스틸 기판 사이에 삽입하여 소자를 제작하였다. 확산 방지막이 없는 경우, SiOx층을 사용한 경우, 그리고 intrinsic ZnO 층을 사용한 경우에, 효율은 각각 7.47, 11.64, and 13.95%로 나타났다. 셀의 크기는 $0.47\;cm^2$이고, 반사방지막은 사용하지 않았다.

  • PDF

A Study on the Reduction of Building Energy Consumption and Generation of BIPV System According to the Increase of the Number of Floors in Office Building (사무소건물 층수 증가에 따른 BIPV 발전량과 건물에너지소비량 저감에 관한 연구)

  • Oh, Myung-Hwan;Yoon, Jong-Ho;Shin, Woo-Cheol
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.36-41
    • /
    • 2011
  • BIPV system that can alternate building envelope by making materials of PV module should be considered in initial design step for applying PV system efficiently in office building. Mean while, area of the building skin also increases as the number of floors increases, but the valid area that can apply BIPV system in effect decreases relatively. Despite of this weak point, installing BIPV system is still being evaluated as the only measure left that can reduce electronic energy consumption in the building. Therefore, the impact on building energy consumption according to the increase of the number of floors when BIPV system is applied in the building was analyzed. And it will be used as basic information for application of BIPV in office building. Conomic about application of BIPV is interpreted to be secured within the 10 story high. Forover the 11 floors, the methods of increasing the contribution ratio produced by BIPV system through the optimization of install angle and increase in install area of south, high efficiency should be considered. The ways to reduce basic load by integrated design with another renewable energy besides BIPV should be found. Later, the study on the total building energy comsumption with PV generation according to the various type of the basic load and ratio of the width and depth will be performed based on this study.

  • PDF

Characteristic Analysis of BIPV Module according to Rear Materials (후면부재에 따른 BIPV 모듈의 특성 분석)

  • Kim, Hyun-Il;Kang, Gi-Hwan;Park, Kyung-Eun;Yu, Gwon-Jong;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.4
    • /
    • pp.28-33
    • /
    • 2009
  • In 2008, the global photovoltaic(PV) market reached 5.6GW and the cumulative PV power installed totalled almost 15GW compared to 9GW in 2007. Due to a favourable feed-in-tariff, Korea emerged in 2008 as the 4th largest PV market worldwide. PV power installation rose 495.5 percent to 268MW in 2008 compare to 45MW in 2007. Building integrated photovoltaic(BIPV) has the potential to become a major source of renewable energy in the urban environment. BIPV has significant influenced on the reflection by rear materials such as white back sheet and the heat transfer through the building envelope because of the change of the thermal resistance by adding or replacing the building elements. In this study, to use as suitable building materials into environmentally friendly house like green home, characteristic analysis of BIPV module according to rear materials achieved. Electrical output of PV module with white back sheet is high about 10% compared to other pv module because of 83% reflectivity of white back sheet compared to 8.4% reflectivity of other PV modules with different rear materials(black back sheet and glass). In the result of outdoor experiment during a year, electrical output of four different PV module is decreased about 3.72%.