• 제목/요약/키워드: 일정열유속덕트

검색결과 5건 처리시간 0.017초

주기적인 압력구배를 받는 덕트에서의 유동 및 열전달특성에 관한 연구 (A study on Flow and Heat Transfer Characteristics in a Duct with Periodic Pressure Gradient)

  • 이재헌
    • 대한기계학회논문집
    • /
    • 제16권2호
    • /
    • pp.369-381
    • /
    • 1992
  • Characteristics of flow and heat transfer have been studied numerically in a square duct with a periodic pressure gradient. The flow in a duct was assumed to be fully developed and constant heat flux was imposed at the surfaces of a square duct. The distributions of axial velocity and time-space averaged temperature are investigated with angular velocity and amplitude ratio at a given Reynolds number 1000. When the periodic pressure gradient was imposed axially in a duct, the reverse flow may be occurred near the duct wall. The magnitude of this reverse flow increases as the amplitude ratio increases or as the angular frequency decreases. In the ranges of the amplitude ratio and the angular velocity in present investigation, the ratio of the periodic time space averaged temperature to the nonperiodic space averaged temperature has been found to be greater than one. This means that the cooling effect at the duct walls deteriorates with a periodic situation compared with nonperiodic one.

$45^{\circ}$ 경사진 거칠기가 설치된 채널에서 유체유동과 열전달에 대한 수치모사 (Numerical Simulation for Heat Transfer and Fluid Flow in the Channel with $45^{\circ}$ Incinlined Rib)

  • 오세경;강호근;김명호;배성택;안수환
    • 동력기계공학회지
    • /
    • 제10권1호
    • /
    • pp.25-33
    • /
    • 2006
  • 거칠기가 한 벽면과 두 벽면에 설치된 사각채널에서 비압축성 유체유동과 열전달을 조사하기위해 3차원 수치모사를 행하였다. CFX (version 5) software package 를 사용하여 계산하였다. 거친 벽은 $45^{\circ}$경사진 거칠기가 설치되어 있다. 채널의 4 벽면은 일정한 열 유속으로 가열하였다. 수치계산 결과는 실험값과 잘 일치 하였다. 연구의 조건은 거칠기 피치와 높이의 비가 8이고, 거칠기 높이와 채널 수력직경의 비가 0.067이며, 레이놀즈수의 범위는 7,600에서 24,900이었다. 연구의 결과는 열전달계수와 마찰계수는 사각채널에서 거친 벽면의 수가 클수록 증가 함을 보였다.

  • PDF

열전달 향상 장치에 따른 평판형 태양열 집열기의 압력강하 및 열전달 특성 (Pressure drop and heat transfer characteristics of a flat-plate solar collector with heat transfer enhancement device)

  • 안성후;신지영;손영석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권5호
    • /
    • pp.453-460
    • /
    • 2013
  • 평판형 태양열 집열기의 효율을 높이기 위한 방법으로 열전달 향상 장치의 삽입, 표면 거칠기의 변화 등 다양한 방법들이 알려져 있다. 본 연구는 실험을 통해 다양한 열전달 향상 장치를 제작하고 이를 덕트에 삽입해 실험을 수행하였다. 실험은 기본적으로 덕트 윗 평판에 일정한 열유속을 가하였고, 삽입된 모델은 매끈한 덕트 형상(Base case)과 Chamfered rib $10^{\circ}$, Chamfered rib $20^{\circ}$, Rib & Groove, Rib & Dimple 모델이다. 실험은 Reynolds 수가 2,300~22,000의 범위에서 이루어졌으며 이는 난류영역에 해당한다. 열전달 향상 장치를 삽입하면 면적의 증가와 2차 유동으로 인하여 열전달이 향상되고, Reynolds 수가 증가할수록 열전달이 향상되었으며 압력강하도 증가하였다. 열전달 측면에서는 Rib & Dimple 모델이 열전달 향상 효과가 가장 좋았으며, 압력강하는 Chamfered rib $10^{\circ}$ 모델이 가장 낮았으며, 성능계수 측면에서도 Chamfered rib $10^{\circ}$ 모델이 가장 높은 것으로 나타났다.

일정 열유속을 가진 사각채널에서 거친 벽면의 수가 열전달에 미치는 효과 (Effect of Number of Rough Walls on Heat Transfer in the Square Channel with a Uniform Heat Flux)

  • 배성택;김명호;이대희;안수환
    • 동력기계공학회지
    • /
    • 제9권1호
    • /
    • pp.30-35
    • /
    • 2005
  • Repeated ribs are used on heat exchanger surfaces to promote turbulence and to enhance convective heat transfer. Applications include fuel rods of gas-cooled nuclear reactors, inside cavities of turbine blades, and internal surfaces pipes used in heat exchangers. Despite the great number of literature papers, only few experimental data concerns detailed distributions of friction factors and heat transfer coefficients in square channels varying the number of rough walls. This issue was tackled by investigating effects of different number of ribbed walls on heat transfer and friction characteristics in square channel. The rough wall had a $45^{\circ}$ inclined square rib. Uniform heat flux was maintained on the whole inner heat transfer channel area. The heat transfer coefficient and friction factor values increased with increasing the number of rough walls.

  • PDF

테이퍼가 설치된 리브(rib)이 있는 채널의 열전달에 대한 수치해석 (Numerical Analysis of Heat Transfer in the Ribbed Channel Inserted with Tape)

  • 강호근;안수환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권5호
    • /
    • pp.638-644
    • /
    • 2010
  • 사각 덕트내 열전달과 유동 양상을 조사하기 위해 꼬임식 테이프 만 설치한 경우와 꼬임식 테이프와 리브(rib)를 설치한 경우에 대해 충분히 발달된 난류유동에 관한 수치 해석을 행하였다. 수치 해석에서는 레이놀즈 수가 8,900에서 29,000 범위의 난류 스월유동, 채널수력직경에 대한 리브의 높이(e/$D_h$)가 0.067, 그리고 채널 수력 직경에 대한 시험부 길이(L/$D_h$)가 30인 경우에 대해 고려하였다. 리브는 채널 바닥면에 만 길이 방향으로 설치하였다. 꼬임식 테이프는 0.1 mm 두께의 탄소강 판 재질이며, 폭은 28 mm, 길이는 900 mm이고 2.5 번 회전시켰다. 각 벽면은 서로 단열된 알루미늄 판으로 구성되었다. 2가지의 가열 조건에 대해 조사 하였다: (1) 사각 전체 벽 면적에 일정한 열유속으로 가열, 그리고 (2) 사각 채널에서 마주보는 상하 양면 만 가열. 연구 결과 상하 양면 만 가열하는 경우가 4면 모두 가열하는 경우보다 열전달 계수가 우수하였고 꼬임식 테이프와 리브를 설치한 경우 열전달 계수가 현저히 향상되었다.