• Title/Summary/Keyword: 일반화 강우유출

Search Result 17, Processing Time 0.026 seconds

Characteristics of stormwter runoff from highways with unit traffic volume (고속도로 자동차 통행량에 따른 강우유출수 유출 특성 분석)

  • Choi, Jiyeon;Hong, Jungsun;Kang, Heeman;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.18 no.3
    • /
    • pp.275-281
    • /
    • 2016
  • This study was conducted to analyze the runoff characteristics of the highway depending on the number of vehicles and to provide the installation proposal of an NPS pollution reduction facility. There were a total of 5 monitoring sites used for the study namely, Gyeongbu, Seohaean, Honam and Tongyeoung Dageon highway. Monitoring events started from 2006 until 2015 having a total of 44 storm events. According to monitoring statistics, the average antecedent dry days (ADD) and rainfall was 6.2 days and 19.2 mm, respectively. The Gyeongbu Highway (H-4) was recorded having the highest Average Daily Traffic and Catchment Area (ADT/CA) with $49.4car/day{\cdot}m^2$ while other site were less than $10car/day{\cdot}m^2$. The average concentration of the NPS pollutants generated from monitoring sites were 63.5 mg/L(TSS), 24.9 mg/L(BOD), 3.35 mg/L(TN), 0.63 mg/L(TP) and 298 ug/L(Total Zn). This exhibited lower values in comparison to the remarks of highway related runoff EMC values published in Korea. Moreover, through the results of the correlation analysis between the contaminant concentration and ADT/CA, $R^2$ value of SS showed the highest correlation with 585. Through the correlation equation between ADT/CA and EMC of TSS, when there is 73.7 mg/L of TSS EMC found from a domestic highway, ADT/CA ratio is normally $13car/day{\cdot}m^2$. Therefore, in a case of more than 13 cars passing through a certain area, the area can be considered and present as the point of generation of nonpoint source pollutants. Also, in this study, since it considered a unit area ADT indicated in previous studies, it was determined that it has a high applicability and utilization in generalized units than conventional study which were conventionally done.

Generalization of Modified TOPMODEL for Rainfall-Runoff Analysis of Sulmachun Watershed (수정 TOPMODEL에 의한 유출해석과 일반화 (설마천 유역을 중심으로))

  • Lee, Hak-Su;Kim, Nam-Won;Kim, Sang-Hyeon
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.3
    • /
    • pp.295-306
    • /
    • 2002
  • The modified TOPMODEL of two storage systems has been integrated to the generalized assumptions of decreasing hydraulic conductivity to vertical direction. Three different recharge functions were introduced to explore the impact of the macropore flow to vortical direction, the storage at the surface zone and the relative storage deficit of the soil matrix. Combinations of these approaches provide 30 type of the model structure for the hillslope hydrology. Developed models have been applied to several hydrologic events at the Sulmachun watershed. The performance evaluation with the Monte carlo simulation suggests that the exponential function of transmissivity reduction should be appropriate form for the physically -based hydrologic simulation on the Sulmachun watershed. It has been shown that the recharge function of macropore flow contributes to improve the predictability of the generalized version of modified TOPMODEL.

Regression Modeling of Water-balance in Watershed (유역(流域) 물 수지(收支)의 회귀모형화(回歸模型化))

  • Kim, Tai Cheol
    • Korean Journal of Agricultural Science
    • /
    • v.10 no.2
    • /
    • pp.324-333
    • /
    • 1983
  • Modeling of longterm runoff is theoritically based on waterbalance analysis. Simplified equation of water balance with rainfall, evapotranspiration and soil moisture storage could be formulated into regression model with variables of rainfall, pan evaporation and previous-month streamflow. The hydrologic response of water shed could be represented lumpedly, qualitatively and deductively by regression coefficients of water-balance regression model. Characteristics of regression modeling of water-balance were summarized as follows; 1. Regression coefficient $b_1$ represents the rate of direct runoff component of precipitation. The bigger the drainage area, the less $b_1$ value. This means that there are more losses of interception, surface detension and transmission in the downstream watershed. 2. Regression coefficient $b_2$ represents the rate of baseflow due to changes of soil moisture storage. The bigger the drainage area and the milder the watershed slope, the bigger b, value. This means that there are more storage capacity of watershed in mild downstream watershed. 3. Regression coefficient $b_3$ represents the rate of watershed evaporation. This depends on the s oil type, soil coverage and soil moisture status. The bigger the drainage area, the bigger $b_3$ value. This means that there are more watershed evaporation loss since more storage of surface and subsurface water would be in down stream watershed. 4. It was possible to explain the seasonal variation of streamflow reasonably through regress ion coefficients. 5. Percentages of beta coefficients what is a relative measure of the importance of rainfall, evaporation and soil moisture storage to month streamflow are approximately 89%, 9% and 11% respectively.

  • PDF

Applicability Evaluation for Discharge Model Using Curve Number and Convolution Neural Network (Curve Number 및 Convolution Neural Network를 이용한 유출모형의 적용성 평가)

  • Song, Chul Min;Lee, Kwang Hyun
    • Ecology and Resilient Infrastructure
    • /
    • v.7 no.2
    • /
    • pp.114-125
    • /
    • 2020
  • Despite the various artificial neural networks that have been developed, most of the discharge models in previous studies have been developed using deep neural networks. This study aimed to develop a discharge model using a convolution neural network (CNN), which was used to solve classification problems. Furthermore, the applicability of CNN was evaluated. The photographs (pictures or images) for input data to CNN could not clearly show the characteristics of the study area as well as precipitation. Hence, the model employed in this study had to use numerical images. To solve the problem, the CN of NRCS was used to generate images as input data for the model. The generated images showed a good possibility of applicability as input data. Moreover, a new application of CN, which had been used only for discharge prediction, was proposed in this study. As a result of CNN training, the model was trained and generalized stably. Comparison between the actual and predicted values had an R2 of 0.79, which was relatively high. The model showed good performance in terms of the Pearson correlation coefficient (0.84), the Nash-Sutcliffe efficiency (NSE) (0.63), and the root mean square error (24.54 ㎥/s).

A Stiudy on the Deveplopment of Algorithm for the Representative Unit Hydrograph of a Watershed as a Closed Linear System. (폐선형계로 본 유역대표 단위유량도의 유도를 위한 알고리즘의 개발에 관한 연구)

  • 김재한;이원환
    • Water for future
    • /
    • v.13 no.2
    • /
    • pp.35-47
    • /
    • 1980
  • An algorithm is developed to derive a representative I hr-unit hydrograph through an analysis of rainfall-runoff relations of a watershed as a closed system. For the base flow seperation of a flood hydrograph the multi-deflection method is proposed herein, which gace better results compared with those by the existing empirical methods. A modified $\Phi$index method is also proposed in this stidy to determine the time distribution rainfall excess of a rainstorm, which is essetially a modification of the commonly used $\Phi$index method of rainfall seperation. With the so-obtained rainfall excess hyetograph and the direct runoff hydrograph a trial and error computation of the ordinates of 1 hr-unit hydrograph was executed in such a manner that the synthesized flood hydrograph closely approximates the observed one, thus resulting a unit hydrograph of a piecewise exponential function type. To verify the validity of this study the 1 hr-unit hydrographs for the Imha and Dongchon in Nagdong River basin, and Yongdam in Geum River basin were derived by this algorithm, and the results were compared with those by the conventional synthetic unit hydrograph method and the Nakayasu method. Besides, the validity of this stiudy was also tested by comparing the observed hydrograph with the one computed by applying the unit hydrograph to a specific rainfall event. To generalize the result of this study a computer program, consisited of a main and three subprograns (for rainfall excess estimation, convolution summation, and sorting), is developed as a package, which is believed to be applicable to other watersheds for the similar purpose as those in this study.

  • PDF

Water Supply and Reliability Increment by Dams Connection (댐간 연결을 통한 공급량 증대 및 신뢰도 향상)

  • Lee, Gwang-Man;Lee, Seung-Yoon;Lee, Eul-Rae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.317-321
    • /
    • 2010
  • 대부분의 유역에는 다수의 댐이 건설되어 운영되고 있는 것이 일반적이며, 이들 댐 군의 효과를 극대화하기 위하여 연계최적운영 기법의 적용이 일반화 되고 있다. 2000년 수립된 국가장기수 자원계획에서도 이미 4대강 수계의 댐 군의 연계운영 효과로 2011년까지 6억 $m^3$를 반영하고 있다. 또한 프론티어 연구개발사업을 통해 순수한 시스템적인 개선으로 30억 $m^3$의 용수를 추가적으로 확보하는 방안이 오래전부터 진행되어 오고 있다. 이와 같은 방법론의 핵심은 수문기상의 예측정도를 높이고 장단기 강우-유출을 사전 혹은 실시간으로 예측하여 수자원시설물의 기능을 최대화시키는 전략으로 현재와 같이 댐과 같은 수리구조물을 신규로 건설하는데 어려움이 많은 경우 유용한 대안이 될 수 있다. 그러나 수리구조물의 운영에 필요한 많은 변수 중에서 가장 예측이 어려우며 또한 효과를 평가할 수 있는 가장 핵심적인 요소인 수문사상에 대한 정보의 신뢰도에는 한계가 있다. 다시 말하면 현재와 같은 상황에서 수자원시설물의 시스템적인 개선을 통한 편익의 신뢰도가 구조물적인 효과의 신뢰도를 보장하기 어렵다는 것이다. 결국 주어진 여건에서 수자원이용의 효과를 극대화시키기 위해서는 구조적 대안과 시스템적인 기법을 같이 적용할 수밖에 없으며 상호 보완적으로 활용하는 것이 가장 합리적일 것이다. 이와 같은 측면에서 구조적인 댐간 연결은 일정범위까지는 확실한 효과를 담보할 수 있으며 이 또한 시스템적으로도 유용할 것이다. 본 연구에서는 이와 같은 개념을 안동댐과 임하댐이 도수터널로 연결될 경우로 가정하여 예상되는 효과에 대하여 평가하였다. 평가방법은 일간연계모의모형과 일간도수연결모의모형을 개발하여 적용하였으며 무효방류량의 감소정도와 용수공급 증가량과 공급의 신뢰도, 부족량의 크기 등을 비교 평가하였다.

  • PDF

A Study on the Relation Characteristics between Bubble Size Distribution and Floating Time (버블의 크기별 입도분포와 부상시간과의 상관특성에 관한 연구)

  • Jeon, Gun;Park, Chul-Hwi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.5
    • /
    • pp.277-281
    • /
    • 2017
  • Lately rainfall characteristics that it rains a lot in a short space of time often occurs. Because of this meteorological phenomena, the flow rate and concentration of initial rainfall for runoff and combined sewer overflows are changed. In the case of this inlet fluctuation, the flotation method at high surface loading rate is suitable for water quality management. the flotation method is able to meet the removal rate requirements of water public zone in 5 to 10 min which is irelatively short period. For assessment and diagonision of flotation method, A/S ratio is applied until now. But unfortunately, this has some limits for evaluation standard for certification and assessment of technical diagnosis and operation. This is why there is different efficiency in the bubble distribution at the same A/S ratio. The velocity and time of floating is changed by the different bubble distributions. The floating time affects the plant volume because the time factor make size dicision. Therefore the charateristics of bubble distribution and floating time at the same A/S ratio is necessary to apply to evaluation standard for certification and assessment of technical diagnosis and operation. For generalization of the method in certification and assessment, the characteristics of bubble distribution was studied. Until recently, using the optical device and shooting live video, there are some analysis technology of the floating factors. But this kind of technology is influenced by the equipment. with this level of confidence about the results, it is difficult to apply to generalize. According this reasons, this study should be applied on experiment generalization of method about measurement of relation between bubble distribution and floating time.