• 제목/요약/키워드: 일반촬영 검사

Search Result 163, Processing Time 0.023 seconds

Structural Design of Digital Radiography Detector using Hybrid Method for the Improvement of Response Property by X-ray (X-ray 반응 특성 개선을 위한 Hybrid형 디지털 방사선 검출기의 구조 설계)

  • Kim, Kyo-Tae;Han, Moo-Jae;Kim, Jin-Seon;Heo, Ye-Ji;Oh, Kyung-Min;Park, Ji-Koon;Nam, Sang-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.6
    • /
    • pp.363-367
    • /
    • 2015
  • Digital radiography is divided into the direct method using photoconductor and indirect method using phosphor based on the principles in acquiring the image information, but both have different advantages and disadvantages. Therefore, this study conducted a preliminary research on the structure of the hybrid detector that combined phosphor and photoconductor to improve the sensitivity of X-ray. As a result, when the tube voltage was adjusted at 30ms of exposure time, the direct structure displayed an overall excellent sensitivity, but at the exposure time of 50ms or more, the hybrid structure displayed a better outcome. This seems to have enough research value considering that various clinical examinations usually include 50ms or more exposure time.

Gastrotomy Approach Retrieval of Esophageal Foreign Body using Long Forceps Technique in Five Dogs (위 절개술 접근과 긴 겸자를 이용한 식도 내 이물 제거 5례)

  • Yoon, Hun-Young;Kang, Myung-Gon;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.26 no.6
    • /
    • pp.628-631
    • /
    • 2009
  • Five dogs presented to the Veterinary Medical Teaching Hospital of the Konkuk University and Hangang Animal Hospital with a history of foreign body ingestion. On physical examination, five dogs showed lethargy, anorexia, or vomiting. Plain radiographs revealed that radiopaque foreign bodies lodged in the heart base or caudal thoracic esophagus. Positive contrast esophagogram revealed that large foreign bodies severely expanded the esophagus and there was no evidence of leakage of the contrast agent from the esophagus into the thoracic cavity. Gastrotomy for retrieval of esophageal foreign bodies using long forceps technique was performed. Esophageal foreign bodies were successfully retrieved in all dogs. The follow-ups were completed 10 days to 2 years after surgery. The follow-up information was based on physical examination by veterinarians and telephone interview with owners. The owners reported that there was no evidence of complications related to surgery such as vomiting, regurgitation, dysphagia, gagging, hyper-salivation, or anorexia in all dogs.

Incidentally Detected Pericardial Defect in a Patient with Pneumothorax as Confirmed on Video-Assisted Thoracoscopic Surgery (흉강경 수술로 확인한 우연히 발견된 기흉을 동반한 심막결손)

  • Hyunwoo Cho;Eun-Ju Kang;Moon Sung Kim;Sangseok Jeong;Ki-Nam Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.749-755
    • /
    • 2021
  • Congenital defects of the pericardium, which are generally asymptomatic, are rare disorders characterized by complete or partial absence of the pericardium. Here, we report a rare case of a 19-year-old male who was incidentally diagnosed with congenital absence of the left pericardium during examination for symptoms of pneumothorax. Chest radiography and CT revealed a collapsed left lung without any evidence of trauma, no unusual findings of free air spaces along the right side of the ascending aorta, heart shifted toward the left side of the thorax, and a shallow chest. Subsequent thoracoscopy confirmed the absence of the left pericardium and displacement of the heart toward the left thoracic cavity. We further discuss the correlation between radiologic images and surgical findings of a congenital pericardial defect associated with spontaneous pneumothorax.

A Study on the Frequency of Occurrence of the Aortic Dissection using CT (CT 검사에서 대동맥박리(aortic dissection)의 발생빈도에 관한 고찰)

  • Dong, Kyung-Rae;Choi, Sung-Kwan;Jang, Young-Ill;Ro, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.115-121
    • /
    • 2008
  • Purpose: Aortic Dissection is very dangerous, prognostic disease, which the bloodstream flow out of the true lumen of the aorta by the bursting of aortic intima resulting in a rapid dissociation of inner and outer layer from the media. It is difficult to diagnose aortic dissection clinically by normal X-ray. This study was to investigate the occurrence frequency by age and number of patients who are identified to be aortic dissection by CT (Computed Tomography) scan. Materials and methods: We investigated the trend of yearly fluctuation, gender, age, and department of clinical research of the 112 patients who conducted CT scan in C- University Hospital for two years from January 2005 to December 2006. The MIP and SSD which reconstructed CT image and the VRT image were obtained for the accurate observation. The result was investigated by comparing normal X-ray and CT scan. Results and Conclusion: 1. The yearly check of 112 patients conducted CT scan showed 37 people (41.9%) in 2005, and it was increased to 65 (58.1%) in 2006 by 1.4 times. 2. The gender distribution of patients given a CT scan showed 45 males (40.1%), and female 67 (59.9 %). The aortic dissection patients were 9 (20%) out of 45 males, 21 (31.3%) out of 67 females and women were 1.6 times more than men. Women are also 1.5 times more than men in the number of examinee. 3. The age distribution of patient's who conducted CT scan revealed that there was no patient under 30 years old while 88.3% of all patients were through 41 to 80 years old. The higher the age was, the higher the occurrence of aortic dissection was. The difference in the occurrence frequency of age was statistically significant (p<0.01). 4. The departments that requested CT scan were the emergency department 46 (41.1%), circulatory internal medicine 37 (33.0%), chest surgery 13 (11.6%), and others 6 (14.3%). The combined ratio of emergency medicine and circulatory internal medicine was 74.1% of all. The results show that the aortic dissection is a very dangerous disease whose patients visit mainly via the emergency room. 5. The aortic dissection patients had normal X-ray readings in 22 (73.3%) out of 30, and only 8 (26.7 percent) are abnormal in the X-ray diagnosis. Therefore, the CT scan needs to be enforced in order to assess accurately the disease of aortic dissection.

  • PDF

Experiment on Camera Platform Calibration of a Multi-Looking Camera System using single Non-Metric Camera (비측정용 카메라를 이용한 Multi-Looking 카메라의 플랫폼 캘리브레이션 실험 연구)

  • Lee, Chang-No;Lee, Byoung-Kil;Eo, Yang-Dam
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.26 no.4
    • /
    • pp.351-357
    • /
    • 2008
  • An aerial multi-looking camera system equips itself with five separate cameras which enables acquiring one vertical image and four oblique images at the same time. This provides diverse information about the site compared to aerial photographs vertically. The geometric relationship of oblique cameras and a vertical camera can be modelled by 6 exterior orientation parameters. Once the relationship between the vertical camera and each oblique camera is determined, the exterior orientation parameters of the oblique images can be calculated by the exterior orientation parameters of the vertical image. In order to examine the exterior orientation of both a vertical camera and each oblique cameras in the multi-looking camera relatively, calibration targets were installed in a lab and 14 images were taken from three image stations by tilting and rotating a non-metric digital camera. The interior orientation parameters of the camera and the exterior orientation parameters of the images were estimated. The exterior orientation parameters of the oblique image with respect to the vertical image were calculated relatively by the exterior orientation parameters of the images and error propagation of the orientation angles and the position of the projection center was examined.

The Evaluation of SUV Variations According to the Errors of Entering Parameters in the PET-CT Examinations (PET/CT 검사에서 매개변수 입력오류에 따른 표준섭취계수 평가)

  • Kim, Jia;Hong, Gun Chul;Lee, Hyeok;Choi, Seong Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.43-48
    • /
    • 2014
  • Purpose: In the PET/CT images, The SUV (standardized uptake value) enables the quantitative assessment according to the biological changes of organs as the index of distinction whether lesion is malignant or not. Therefore, It is too important to enter parameters correctly that affect to the SUV. The purpose of this study is to evaluate an allowable error range of SUV as measuring the difference of results according to input errors of Activity, Weight, uptake Time among the parameters. Materials and Methods: Three inserts, Hot, Teflon and Air, were situated in the 1994 NEMA Phantom. Phantom was filled with 27.3 MBq/mL of 18F-FDG. The ratio of hotspot area activity to background area activity was regulated as 4:1. After scanning, Image was re-reconstructed after incurring input errors in Activity, Weight, uptake Time parameters as ${\pm}5%$, 10%, 15%, 30%, 50% from original data. ROIs (region of interests) were set one in the each insert areas and four in the background areas. $SUV_{mean}$ and percentage differences were calculated and compared in each areas. Results: $SUV_{mean}$ of Hot. Teflon, Air and BKG (Background) areas of original images were 4.5, 0.02. 0.1 and 1.0. The min and max value of $SUV_{mean}$ according to change of Activity error were 3.0 and 9.0 in Hot, 0.01 and 0.04 in Teflon, 0.1 and 0.3 in Air, 0.6 and 2.0 in BKG areas. And percentage differences were equally from -33% to 100%. In case of Weight error showed $SUV_{mean}$ as 2.2 and 6.7 in Hot, 0.01 and 0.03 in Tefron, 0.09 and 0.28 in Air, 0.5 and 1.5 in BKG areas. And percentage differences were equally from -50% to 50% except Teflon area's percentage deference that was from -50% to 52%. In case of uptake Time error showed $SUV_{mean}$ as 3.8 and 5.3 in Hot, 0.01 and 0.02 in Teflon, 0.1 and 0.2 in Air, 0.8 and 1.2 in BKG areas. And percentage differences were equally from 17% to -14% in Hot and BKG areas. Teflon area's percentage difference was from -50% to 52% and Air area's one was from -12% to 20%. Conclusion: As shown in the results, It was applied within ${\pm}5%$ of Activity and Weight errors if the allowable error range was configured within 5%. So, The calibration of dose calibrator and weighing machine has to conduct within ${\pm}5%$ error range because they can affect to Activity and Weight rates. In case of Time error, it showed separate error ranges according to the type of inserts. It showed within 5% error when Hot and BKG areas error were within ${\pm}15%$. So we have to consider each time errors if we use more than two clocks included scanner's one during the examinations.

  • PDF

The Satisfaction Survey of Users and Patients on the Developed Disposable Tourniquet (개발한 일회용 지혈대의 사용자 및 환자 만족도 조사)

  • Kim, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.615-622
    • /
    • 2016
  • The 18~20G needle is used to computer tomography (CT) contrast examination. Therefore, a patient has to apply a self-administering hemostasis (conventional method: CM) and often experience bleeding in the course. Thus, we developed the new disposable transparent tourniquet (TT) for reducing. This study was to compare the usefulness between the proposed transparent tourniquet and the existing hemostatic methods. A Satisfaction survey was conducted by 50 patients and 25nurses. The survey contained the satisfaction of the convenience, safety, sanitation, and wearing sensation of transparent tourniquet. We employed face-to-face interview on 5 points likert scales. And Chi-square, paired T-test were used for the statistics verification. As for the patients, the satisfaction levels were measured for each category with the gender, age. Patients evaluation, overall satisfaction high average sore used TT and there were statistical significance by paired T-test(p<0.05). The following is the average satisfaction level for each category: $4.4{\pm}0.53$ in; $4.28{\pm}0.57$ in safety; $4.52{\pm}0.54$ in sanitation; $4.16{\pm}0.54$ in wearing sensation. So the overall satisfaction level is measured at $4.34{\pm}0.51$. As for the nurses, CT work experience and the current satisfaction with tourniquet were counted as variables. The satisfaction level for each category is: $3.8{\pm}0.7$ in; $3.6{\pm}0.68$ in safety; $3.4{\pm}0.5$ in sanitation; $3.9{\pm}0.49$ in hemostasis. The overall satisfaction level is $3.8{\pm}0.3$. Patients' satisfaction levels were very high with little difference among variables. Nurses' satisfaction levels were different with the TT depending on their work experience but their overall satisfaction was high. This TT will be a starting point to minimizing patient's inconvenience and more studies are necessary to enhance their satisfaction.

Aorta-esophageal Fistula That Developed after Endovascular Stent-grafting of a Mycotic Aneurysm - A case report- (감염성 대동맥류에 혈관 내 스텐트 삽입 시행 후 발생한 대동맥-식도루 - 1예 보고 -)

  • Nam, Jin-Hae;Park, Kay-Hyun;Yoo, Jae-Suk;Lee, Jae-Hang;Lim, Cheong;Jheon, Sang-Hoon
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.781-784
    • /
    • 2010
  • A 74-year-old woman presented at our hospital with hemoptysis. Three months ago, she had endovascular stent-grafting done by a general surgeon for a saccular thoracic aneurysm that was found accidentally following an episode of fever and chills. Despite a lasting fever after the procedure, she was discharged without further treatment and follow-up. She was subsequently admitted to the hospital for evaluation and several exams were performed. Chest CT scans and an esophagoscopy identified an aorto-esophageal fistula at the level of the aorta that was covered by a previous stent-graft. After extensive administration of antibiotics, surgery was done - esophagectomy, cervical esophago-gastrostomy and replacement of the thoracic aorta. She was later discharged uneventfully.

A study on measurement of the pollution levels and disinfection of medical radiation shielding for lead apron (의료방사선 차폐용 납 가운의 오염도 측정 및 소독에 관한 연구)

  • Kim, Hyeon-Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.490-497
    • /
    • 2016
  • This study compared and analyzed the pollution levels of radiation shielding aprons and ways to sterilize them using 30 lead aprons. After collecting samples from the center of the lead apron, where contact is most frequent, experiments were conducted employing Coagula and Latex methods. Using the culture medium where bacteria grew, measurements of the pathogen count and identification were performed. The greatest number of pathogens were $7.16{\pm}10$, which were detected on the lead apron from general X-ray room #2, but there was no significant difference according to the facilities (p > 0.05). Compared to how many pathogens remained between using the disinfectant ethanol and tissue, the pathogens decreased by $0.01{\pm}0.4$ (p < 0.05) after using disinfectant ethanol and by $0.87{\pm}1.7$(p < 0.05) after using disinfectant tissue. The Pearson correlation test revealed a significant correlation (-0.296, p < 0.05) between them. According to this research, there were pathogens on the lead aprons and the number of pathogens was determined by statistical analysis. It is expected that the rate of radiology technologists, patients, and medical equipment infected by pathogens will be reduced by the proper use of sterilization with a disinfectant ethanol.

A Study on MR Imaging Method for The Patient with Inserting Shoulder Joint Suture Anchor (견관절 삽입술을 시행한 환자의 자기 공명 영상법에 관한 연구)

  • Park, Eui-Cheol;Bae, Seok-Hwan;Ryu, Yeun-Chul;Park, Young-Joon;Kim, Yong-Gwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.513-519
    • /
    • 2021
  • Metallic suture anchors are very useful and common fixation devices that are inserted into the target bone to sustain the tendon of a patient with musculus supraspinatus tendon ruptures. On the other hand, the presence of a metallic material prosthesis, such as a metal suture anchor, causes severe MR imaging artifacts, including field distortion, signal loss, and failure of fat suppression. The difference in magnetic susceptibility between metal and other organic materials causes magnetic field distortion surrounding the prosthesis. The resulting magnetic field inhomogeneity makes the images with a lower signal-to-noise ratio and distortion. For a patient with a suture anchor implanted, MR imaging is the golden standard for determining the postoperative prognosis, and a fat-saturation sequence is one of the imaging methods most affected by metal-induced artifacts. In this study, three fat-saturation sequences were compared. Artifact quantification and contrast comparison between the supraspinatus tendon and the surrounding muscle were presented. The images obtained using the STIR pulse sequence showed fewer susceptibility artifacts and better visibility in the supraspinatus tendon and the tissue area. Therefore, the STIR sequence is the most appropriate fat-saturation imaging method for patients with a metallic prosthesis.